• 제목/요약/키워드: ozone alarm

검색결과 3건 처리시간 0.017초

통계분석을 이용한 광주지역 대기오염도 (An Assessment of Air Quality Using Statistical Analysis in Gwangju Area)

  • 서광엽;백계진;신대윤
    • 한국환경보건학회지
    • /
    • 제30권5호
    • /
    • pp.417-426
    • /
    • 2004
  • We investigate changing characteristics and concentration distribution of ambient air quality using data from which obtained local ambient air monitoring network and local meterological measuring sites in Gwangju area from January to December in 2003. Sulfur dioxide ($SO_2$) showed that increase from 8 AM and decrease in 6 PM but, it was not drastically changed concentration. it also 0.010 ppm in 1995 from at this time it's decrease step by step and than some constant in year 2001 to 2003. Nitrogen dioxide ($NO_2$) concentration was showed highest peak in 10 AM and increase again at 6 PM. And also it showed peak concentration (0.026 ppm) in 2001 and decreased from after that times. Ozone was showed peak concentration in 1 PM and Nitrogen dioxide was ditto in 10 AM from this data, we can conclude that this two article ws showed chemical reaction by 3 to 5 hours. There was no case of Ozone alarm in Gwangju area since 1995, but it showed highest ozone concentration (over 0.070 ppm) in May and June of the year and 2 to 4 PM of the day and sometimes it showed increase at the dawn. Ozone product optimum condition was that air temperature is over $25^{\circ}C$, no rain and increase solar radiation (over $20MJ/m^2$) and no wind or below 2.0 m/s wind speed.

대구지역 대기 중 VOCs 농도 및 발생원 특성 (Characteristics of Source and Concentration of VOCs in Daegu)

  • 구민정;최성우
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.543-553
    • /
    • 2005
  • In recent days, photochemical smog due to the rapid industry development and vehicle increasement has become a critical pollutant in the metropolitan area and the number of ozone alarm signal has increased every year. This research was performed to evaluate VOCs emission source characteristics and concentration of VOCs in Daegu. The site average concentration was observed in the following order: industrial area > commercial area > residential area. Most of the VOCs species except toluene showed variations with higher concentration during nighttime, and lower concentration during the daytime. The major VOCs of stationary emission source were BTEX(benzene, toluene, ethylbenzene. xylene) and methylene chloride, trichloroethene and styrene. Also, those of automobile exhaust were toluene and benzene. Also, the major VOCs concentration emited by the vehicle fuel was observed in the following order: gasoline > light oil > liquefied petroleum gas (L.P.G). Correlation coefficients values were estimated between major VOCs such as toluene, ethylbenzene, m,p-xylene, o-xylene. Results showed that correlation coefficient values were significant magnitude above 0.76. Also, there showed highly significant correlations among ethyl benzene, m,p-xylene, and o-xylene concentration(Pearson correlation coefficients, r=0.868-0.982). Calculated correlation coefficients among commercial area,industrial area and residential area were 0.934-0.981, they showed high correlation. There showed highly correlation between stationary emission source and industrial area, compared with commercial area and residential area. Also, calculated correlation coefficients among commercial area, industrial area, residential area and automobile exhaust were 0.732, 0.725, 0.777, respectively.

한냉물리치료기의 개발 (The Development of a Cryotherapy System)

  • 김영호;양길태;장윤희;박시복;류진상
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권6호
    • /
    • pp.617-622
    • /
    • 1998
  • 신냉매인 R-404A를 사용하여 저온특성이 우수한 한냉물리치료기를 개발하였다. 임상평가를 통해서 침온도계를 슬관절 강 내 및 둔부근육 내에 삽입하여 직접 근육온도를 측정하였고, 적외선체열촬영기를 이용하여 표피온도를 객관적으로 측정하였다. 슬관절 부위에 대한 5분 동안의 한냉물리치료에 따른 표피 및 관절강 내 온도변화를 측정한 결과, 표피는 23.3${\pm}4.7^{circ}C$, 관절강 내는 4.1${\pm}1.0^{circ}C$의 온도저하를 보였으며 2~3시간이 경과한 후에도 한냉치료효과가 지속됨을 알 수 있었다. 냉기치료 후 둔부근육에서 측정된 최저온도는 2, 4, 6cm 깊이에서 각각 35.1${\pm}$0.7, 36.2${\pm}$0.4, 36.9${\pm}0.3^{circ}C$였고, 이에 도달하기까지의 시간은 각각 20${\pm}$3.0, 25${\pm}$4.5, 45${\pm}$8.5분이었다. 치료 후 2시간이 경과한 뒤의 온도는 근육의 2, 4, 6cm 깊이에서 각각 36.2${\pm}$0.5, 36.6${\pm}$0.3, 36.9${\pm}0.3^{circ}C$였고, 치료 전에 비해 유의한 온도 차이가 있었다. 또한 5분간 한냉을 가하는 동안 피부 및 근육 내에서 온도의 증가, 즉 반응성 혈관확장은 관찰되지 않았다. 본 연구를 통해서 개발된 한냉물리치료기는 근육의 연축 혹은 강직, 물리적 외상, 화상, 동통의 감소, 관절염 등에 효과적으로 사용되리라 생각된다.

  • PDF