• Title/Summary/Keyword: ozone/activated carbon process

Search Result 55, Processing Time 0.022 seconds

Removal characteristics of NOM in advanced water treatment using ceramic MF membrane (세라믹막(MF) 고도정수처리에서 NOM 제거 특성)

  • You, Sang-Jun;Park, Sung-Han;Lim, Jae-Lim;Suh, Jeong-Min;Jang, Seong-Ho;Hong, Sung-Chul;Yi, Pyong-In
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.367-376
    • /
    • 2014
  • This study assessed the removal efficiency of NOM which is known as the precursors of DBPs in advanced water treatment using the ceramic membrane filtration, introduced the first in the nation at the Y water treatment plant (WTP). It is generally well-known that the removal of NOM by MF Membrane is very low in water treatment process. But, the result of investigation on removal efficiency of NOM in advanced water treatment using the ceramic membrane was different as follows. The removal rate of organic contaminant by the ceramic membrane advanced water treatment was determined to be 65.5% for the DOC, 85.8% for UV254, and 77 to 86% for DBPFP. The removal rate of pre-ozonation was found to be 6 to 15% more effective compared with the pre-chlorination. The removal rate of DOC and $UV_{254}$ in biological activated carbon(BAC) process was over 50% and 75%, respectively although the rate was decreased 10 ~ 20% according to analysis items in converting from GAC to BAC.

Fates and Removals of Micropollutants in Drinking Water Treatment (정수처리 과정에서의 미량오염물질의 거동 및 제거 특성)

  • Nam, Seung-Woo;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.5
    • /
    • pp.391-407
    • /
    • 2013
  • Micropollutants emerge in surface water through untreated discharge from sewage and wastewater treatment plants (STPs and WWTPs). Most micropollutants resist the conventional systems in place at water treatment plants (WTPs) and survive the production of tap water. In particular, pharmaceuticals and endocrine disruptors (ECDs) are micropollutants frequently detected in drinking water. In this review, we summarized the distribution of micropollutants at WTPs and also scrutinized the effectiveness and mechanisms for their removal at each stage of drinking water production. Micropollutants demonstrated clear concentrations in the final effluents of WTPs. Although chronic exposure to micropollutants in drinking water has unclear adverse effects on humans, peer reviews have argued that continuous accumulation in water environments and inappropriate removal at WTPs has the potential to eventually affect human health. Among the available removal mechanisms for micropollutants at WTPs, coagulation alone is unlikely to eliminate the pollutants, but ionized compounds can be adsorbed to natural particles (e.g. clay and colloidal particles) and metal salts in coagulants. Hydrophobicities of micropollutants are a critical factor in adsorption removal using activated carbon. Disinfection can reduce contaminants through oxidation by disinfectants (e.g. ozone, chlorine and ultraviolet light), but unidentified toxic byproducts may result from such treatments. Overall, the persistence of micropollutants in a treatment system is based on the physico-chemical properties of chemicals and the operating conditions of the processes involved. Therefore, monitoring of WTPs and effective elimination process studies for pharmaceuticals and ECDs are required to control micropollutant contamination of drinking water.

Status of Membrane Filtration in Japan : Application for Water Supply

  • Minami, Katsuyoshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.55-62
    • /
    • 1997
  • In Japan, the membrane filtration is becoming a common technology for municipal water supply system especially for small plant. 6 years before (1991), the national research project of membrane filtration for small plant has started. The project was named as "MAC 21", MEMBRANE AQUA CENTURY 21. In the project the Ministry of Health and Welfare, 8 universities and 18 water treatment plant companies have been involved. This was the first attempt to research a common theme in joint with government, universities and private companies. After three years, the guide line for membrane filtration application for small plant has been established. This has promoted to install some actual plant. And also, another joint research for "RESEARCH OF MEMBRANE FILTRATION FOR ADVANCED WATER TREATMENT" has started in 1994 and completed in March, 1997. The project was named as MAC21. In the former project the main objectives were removal of turbidity and bacteria from water. However, in new project the objective was establishment of the further advanced membrane filtration technology which would be applicable for trace chemical components removal such as tri-halo-methane pre-courser, agricultural chemicals removal, offensive smell and taste removal and virus removal. For the objectives, application of nanofiltration and hybrid-system, a combination of micro-filtration ultra-filtration with biological, ozone and activated carbon treatment process have been studied. In addition, application of membrane filtration for treatment of back-wash waste water originated from membrane filters and conventional sand filters has.been studied. At the end of March of this year, about 30 membrane filtration plants are actually supplying the water, the total treatment capacity is about 6,000 m$^{3}$/day and another 20 will be installed within one year.led within one year.

  • PDF

Economic Feasibility Study on the Efficient Use of Advanced Water Treatment for Water Supply (상수고도정수처리의 효율적 이용을 위한 경제성 검토)

  • 이상일
    • Water for future
    • /
    • v.29 no.1
    • /
    • pp.191-202
    • /
    • 1996
  • Advanced water treatment for water supply is being introduced for the treatment of various organic materials which cannot be removed by conventional water treatment methods. While the development of advanced water treatment system appropriate to the domestic enviropment of advanced water treatment system appropriate to the domestic environment is essential, the study on the economic costs and the social impact is also of importance. In this paper, it is shown how to estimate the costs (capital and maintenance) for advanced water treatment facilities, especially those using ozone treatment combined with activated carbon process and membrance separation. Estimated costs were compared with the government budget. Also, a general relation between the system capacity and investment was derived. Four alternatives were considered form the aspect of the amount of water to be produced and the delivery system to the user. These alternatives were applied to the city of Pusan. It turned out that bottled water, produced only for drinking, has best economic advantages in having minimum system capacity without detriment to water quality.

  • PDF

Estimate of Nitrous Oxide Emission Factors from Municipal Wastewater Treatment Plants (하수처리 공정별 아산화질소(N$_2$O) 배출계수 산정)

  • Yang, Hyung-Jae;Park, Jung-Min;Kim, Min-Jung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.12
    • /
    • pp.1281-1286
    • /
    • 2008
  • Nitrous oxide(N$_2$O) is well known as a greenhouse gas that contributes to the global warming (310 times more per molecule than carbon dioxide) and to the destruction of the ozone layer. The objective of this study is to estimate N$_2$O emission factor using an emission isolation flux chamber from municipal wastewater treatment plants. N$_2$O gas was analysed by GC/ECD with 6 port gas sampling valve. The results of this study were as follows. N$_2$O emission factor of 5-Stage process from Y wastewater treatment plants was lowest as 0.94 g-N$_2$O/kg-TN. And that of other processes were 2.65 g-N$_2$O/kg-TN for Activated sludge process, 9.30 g-N$_2$O/kg-TN for Denipho process, and 26.73 g-N$_2$O/kg-TN for Sequencing Batch Reactor process. We have known that 5-Stage process is most appropriate process to reduce greenhouse for municipal wastewater treatment plants.