• Title/Summary/Keyword: oxygenator

Search Result 92, Processing Time 0.03 seconds

Changes of Plasma Immunoglobulins and Complements after Extracorporeal Circulation (체외순환후 혈청내 Immunoglobulin 과 보체의 변화에 관한 연구 - 막형 인공산화기와 기포형 인공산화기의 비교 -)

  • 이철주
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.613-618
    • /
    • 1988
  • The exposure of blood to foreign materials can cause the denaturation of plasma protein components such as immunoglobulins and complements. And those phenomena increase the morbidity and mortality after intracardiac operations through the cardiopulmonary bypass. From April, 1987 to September, 1987, we had observed the serial changes of plasma total protein IgG, IgA, IgM, complements[C3, C4] in bubble oxygenator group[n=5] and membrane oxygenator group[n=5]. Statistically significant difference between two groups were present in total protein and C3. We conclude that using membrane oxygenator in long extracorporeal circulation can reduce the activation of alternative pathway of complement system, and which can reduce post-perfusion complications of the lung though we can`t prove it in mass populations.

  • PDF

Experiences of Tracheal Procedure Assisted by Extracorporeal Membrane Oxygenator

  • Kim, Ji Eon;Jung, Sung-Ho;Ma, Dae Sung
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.80-83
    • /
    • 2013
  • We report on the application of a venovenous type extracorporeal membrane oxygenator (ECMO) in high-risk tracheal procedures in six cases consisting of five patients with tracheal stenosis. An ECMO should be helpful for preventing respiratory emergency during a tracheal procedure.

Liquid Flow and Pressure Drop of an Outside Flow Membrane Oxygenator with Hollow Fibers (외부흐름 중공사 막형 인공폐의 액체흐름과 압력손실)

  • 이삼철;김기범
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.27-32
    • /
    • 2002
  • The purpose of this study was to evacuate the effects of the number of tied hollow fibers in a novel membrane oxygenator that satisfied the limiting factor of minimizing the friction loss in the intravascular blood flow Pattern. The membrane oxygenator is a bundle consisted of several hundred ho1low fibers haying the outside diameter of 380 $\mu m$ and the axial jacket length of 600 mm. The eight different variation of tied hollow fibers in a bundle were designed. and the liquid flow pattern was controlled by a pump. The liquid pressure drop was measured by in vitro experiments using water and g1ycero1. Uniform blood flow pattern was observed for each number of tied hollow fibers. Pressure drop was 13-16 mmHg outside of the membrane oxygenator consisting of up to 700 ho1low fibers. More effective contact of liquid with the tied ho1low fibers was observed as a decrease in the number of the tied hollow fibers. and resulted in the enhancement of the friction tractor

Type I Ventricular Septal Defect in Korean Pateints (한국인의 심실중격결손증 제 1형)

  • Lee, Yung-Kyoon;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.418-421
    • /
    • 1980
  • During the period from August 1959 to end of July 1980, 69 cases of Type I VSD were noted among 235 cases of ventricular septal defect who were operated utilizing cardiopulmonary bypass in the Department of Cardio-thoracic Surgery, College of Medicine, Seoul National University(29.4%). During the same period 1162 open heart surgery cases were experienced among whom 778 cases were congenital anomalies. There were no significent differences between Type I '||'&'||' other tvpo:s of VSD in sex and age distribution. In Type I VSD frequency of aortic regurgitation association was much higher than rest of the types. (8.7% to 2.6%). Necessity of patch closure in Type I was not different from other types. The high incidence of Type I VSD is quite similar to Japanese references which show quite higher ratio compared with from Euroamerican caucasian patients materials. All cases were operated on with bubble type oxygenator mainly Shiley**" oxygenator utilizing hypothermic hemodilution perfusion technique.echnique.

  • PDF

Cardiac Surgery : A report of 1640 cases (심장질환의 외과적 치료 -1640 수술예 보고-)

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.92-99
    • /
    • 1980
  • From 1958 up to the end of April 1980, during the period of 12 years 1640 cardiac surgery cases including 1069 open heart surgery and 304 valve replacement cases, were operated in this Department. There were 1070 congenital anomaly and 570 acquired disease cases. In 1070 congenital anomaly cases 673 acyanotic and 397 cyanotic anomaly patients were noted. In acquired diseases 94 pericardial and 456 valvular cases were found. Among 456 valve cases 189 mitral stenosis, 133 mitral insufficiency, 30 aortic valve lesion, 97 double valve, and 7 triple valve lesion patients were noted. Among 304 valve replacement cases 209 mitral, 34 aortic, 5 tricuspid, 34 aortic with mitral, 20 mitral with tricuspid, and 2 triple valves were replaced. Annual increase `of open heart surgery cases and decrease of operative deaths were remarkable in recent years. In recent years Shiley** oxygenator in pump-oxygenator set up and Ionescu** bovine pericardial xenograft bioprosthesis were used for valve replacement mainly.

  • PDF

Blood Conservation in Coronary Artery Bypass Surgery - in 24 consecutive patients - (관상동맥 우회로술 환자에서 혈액 보존법)

  • 최종범
    • Journal of Chest Surgery
    • /
    • v.25 no.10
    • /
    • pp.1048-1054
    • /
    • 1992
  • With use of a simple, inexpensive and nonpharmacological program for blood conservation, 24 consecutive patients underwent elective or urgent coronary artery bypass grafting without need of homologous red cell transfusions and /or fresh frozen plasma transfusions in 16 patients[66.7%]. Left internal mammary artery graftings were done in 18 patients[75%], with supplemental saphenous vein grafts in all. Intraoperatively, autologous heparinized blood was removed before bypass and retransfused at the conclusion of ext-racorporeal circulation. The volume remaining in the oxygenator and tubing set was returned without cell processing or hemofiltration. Using the hard-shell cardiotomy reservoir from the oxygenator, autotransfusion of the shed mediastinal blood was continued hourly by the next early;norning. The mean postoperative mediastinal blood loss was 364$\pm$234ml, whereas 553$\pm$383ml was autotransfused. 4 patients [16.7%] received homologous blood and an additional 4 patients[16.7%] fresh frozen plasma. Thus, in total, 16 patients[66.7%] were not exposed to any homologous blood products during the hospital stay. At discharge, the mean hemoglobin concentration was 10.3$\pm$1.6g /dl. Postoperative complications were few and there was no hospital death.

  • PDF

Influences of Prolonged Extracorporeal Circulation on Organ Function in Dogs (장시간의 체외순환이 생체에 미치는 영향)

  • 김의윤
    • Journal of Chest Surgery
    • /
    • v.7 no.1
    • /
    • pp.73-78
    • /
    • 1974
  • Influences on organ function were studied in animals during prolonged extracorporeal circulation with a bubble type of oxygenator. More than six hours of total cardiopulmonary bypass was performed under mild hypothermia by means of an extracorporeal circulation system in five dogs. Obtained results were summarized as follows. 1. The renal function was not so impaired seriously until four hours of extracorporeal circulation. However, there was more serious impairment of renal function in this study when extracorporeal circulation was carried out for a period of five hours or more. 2. There was gradual hepatic damage during extracorporeal circulation and the damage was more significant after bypass for a period of five to six hours. 3. There was a significant decrease in serum K during bypass, irrespective of the pump oxygenator prime with a high K solution. The reason for this is complex and due to many factors, however, it was evidently related to serum glucose levels during extracorporal circulation.

  • PDF