• Title/Summary/Keyword: overlapping ratio

Search Result 152, Processing Time 0.033 seconds

A Study on Image Restoration Filter in Mixed Noise Environments (복합잡음 환경에서 영상복원 필터에 관한 연구)

  • Long, Xu;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.2001-2007
    • /
    • 2014
  • Image signal related technology has been developing via various display equipment development and popularization of contents. However, errors occur in these image contents due to addition of excess noise from several cause during the process of general image signal data processing, transmission and storage. In terms of noise added to the image content, there are various types in accordance with cause of occurrence and form, and it is typically impulse noise, gaussian noise and complex noise which is composed of two types of overlapping noise. In this paper, complex algorithm is suggested in order to lessen the effect of mixed noise added to the image content by putting it through noise judgement process and categorizing each into impulse and gaussian noise and processing them separately. And in order to demonstrate the superiority of the suggested algorithm, PSIN(peak signal to noise ratio) was used as the standard of judgement.

One-Channel Phased-Array Quadrature RF Coil for Spine Magnetic Resonance Imaging (척추 MRI를 위한 One-Channel Phased-Array Quadrature RF 코일)

  • 양윤정;김선경
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.129-132
    • /
    • 1998
  • A new one-channel phased-array quadrature RF coil is developed for spine MR imaging. Quadrature RF coils for MRI have been used to improve the signal-to-noise ratio (SNR) by$"\squt{2}"$ using two orthogonal RF coils in combination. More recently, the phased-array RF coil has been proposed for more improvement of SNR by using an array of reduced-size RF coil elements. Two schemes proposed for the new phased-array quadrature RF coil are:(1) Proper overlapping of two quadrature RF coils thus removing the mutual inductance and (2) Attaching preamplifiers right after the coil section and combining the signal with proper phase delays. The coil has been implemented for receive-only mode, and tested by phantom and volunteer imaging. The experimental results show the utility of the proposed RF coil.d RF coil.

  • PDF

Change in nostril ratio after cleft rhinoplasty: correction of nostril stenosis with full-thickness skin graft

  • Suh, Joong Min;Uhm, Ki Il
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.2
    • /
    • pp.85-92
    • /
    • 2021
  • Background: Patients with secondary deformities associated with unilateral cleft lip and nose might also suffer from nostril stenosis due to a lack of tissue volume in the nostril on the cleft side. Here, we used full-thickness skin grafts (FTSGs) to reduce nostril stenosis and various methods for skin volume augmentation. We compared the changes in the symmetry of both nostrils before and after surgery. Methods: From February 2016 to January 2020, 34 patients underwent secondary cheiloplasty and open rhinoplasty for secondary deformities of the unilateral cleft lip and nose with nostril stenosis. FTSG was used on the nostril floor, nasal columella, and alar inner lining. The measured nasal profile included the nostril surface, nostril circumference, width of the nostril floor, and distance from the alar-facial groove to the nasal tip. The "overlap area," which was defined as the largest overlapping area when the image of the cleft nostril was flipped to the left and right and overlaid on the image of the normal side nostril, was also calculated. The degree of symmetry was evaluated by dividing the value of the cleft side by that of the normal side of each measured profile and expressed as "ratios." Results: The results of all profile ratios, except for the nostril floor width, became significantly close to 1, which represents full symmetry. The overlap area ratio improved from 62.7% to 77.3%, meaning that the length and width of the nostril as well as the overall shape became similar (p< 0.05). Conclusion: When performing cleft rhinoplasty with nostril stenosis, FTSG is useful to achieve symmetry in the nostril size and shape. Skin grafting is simpler to perform than the other types of local flap, and the results are generally satisfactory.

Axially-loaded multiplanar tubular KTX-joints: numerical analysis

  • Zhang, Chenhui;Zou, Bo;Yang, Guotao
    • Steel and Composite Structures
    • /
    • v.42 no.2
    • /
    • pp.173-190
    • /
    • 2022
  • With the development of spatial structures, the joints are becoming more and more complex to connect tubular members of spatial structures. In this study, an approach is proposed to establish high-efficiency finite element model of multiplanar KTX-joint with the weld geometries accurately simulated. Ultimate bearing capacity the KTX-joint is determined by the criterion of deformation limit and failure mechanism of chord wall buckling is studied. Size effect of fillet weld on the joint ultimate bearing capacity is preliminarily investigated. Based on the validated finite element model, a parametric study is performed to investigate the effects of geometric and loading parameters of KT-plane brace members on ultimate bearing capacity of the KTX-joint. The effect mechanism is revealed and several design suggestions are proposed. Several simple reinforcement methods are adopted to constrain the chord wall buckling. It is concluded that the finite element model established by proposed approach is capable of simulating static behaviors of multiplanar KTX-joint; chord wall buckling with large indentation is the typical failure mode of multiplanar KTX-joint, which also increases chord wall displacements in the axis directions of brace members in orthogonal plane; ultimate bearing capacity of the KTX-joint increases approximately linearly with the increase of fillet weld size within the allowed range; the effect mechanism of geometric and loading parameters are revealed by the assumption of restraint region and interaction between adjacent KT-plane brace members; relatively large diameter ratio, small overlapping ratio and small included angle are suggested for the KTX-joint to achieve larger ultimate bearing capacity; the adopted simple reinforcement methods can effectively constrain the chord wall buckling with the design of KTX-joint converted into design of uniplanar KT-joint.

Evaluation of Failure Mode in Concrete Beam Restrengthened with GFRP with Various Initial Conditions (GFRP로 보강된 다양한 초기 조건의 콘크리트보의 파괴 거동 평가)

  • Jin-Won Nam;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.177-183
    • /
    • 2023
  • Various failure modes occur in the concrete beams reinforced with GFRP(Glass Fiber Reinforced Plastic) under initial condition and repairing patterns. In this study, the failure behaviors of concrete beams restrengthened with GFRP sheet with slightly higher elastic modulus than concrete were investigated. For the tests, concrete beams with 24 MPa were manufactured, and the effects of initial notch, overlapping, end-strip reinforcement, and fiber anchors were analyzed on failure load. The cases of GFRP overlap around notch and the initial notch showed increasing failure loads similar to those of normal restrengthened case since the epoxy of the saturated GFRP sufficiently repaired the notch area. Compared to the control case without restrengthening of GFRP, the concrete with initial notch showed 0.78 of loading ratio and normal restrengthening showed 4.43~5.61 times of increasing ratio of failure loading, where interface-debonding from flexural crack were mainly observed. The most ideal failure behavior, break of GFRP, was observed when end-strip over 1/3 height from bottom and fiber anchor were installed, which showed increasing failure load over 150 % to normal restrengthening.

An Experimental Study on the Structural Behavior of Concrete Columns Confined with Welded Reinforcement Grids (용접 띠철근 보강된 콘크리트 기둥의 역학적 거동에 관한 실험적 연구)

  • Choi, Chang-Sik;Saatcioglu, Murat
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.187-196
    • /
    • 1999
  • An experimental investigation was conducted to study the structural behavior of concrete columns confined with welded grids. The full-scale columns with different volumetric ratio, spacing and arrangement of welded reinforcement grids were tested under simulated seismic loading. The columns were subjected to constant axial compression of approximately 20% or 40% of their capacities accompanied by incrementally increasing lateral deformation reversals. The results indicate that the welded reinforcement grid can be used effectively as confinement reinforcement provided that the steel used, have sufficient ductility and the welding process employed does not alter the strength and elongation characteristics of steel. The grids improved the structural performance of columns, which developed lateral drift ratios in excess of 3% with the spacing and volumetric ratio of transverse reinforcement similar to those required by the ACI 318-95 Building Code. Drift capacity further increased when grids with larger number of cells were used. Furthermore, the use of grids reduced congesting of reinforcement while the dimensional accuracy provided perfect support to longitudinal reinforcement.

A Single-Bit 2nd-Order CIFF Delta-Sigma Modulator for Precision Measurement of Battery Current (배터리 전류의 정밀 측정을 위한 단일 비트 2차 CIFF 구조 델타 시그마 모듈레이터)

  • Bae, Gi-Gyeong;Cheon, Ji-Min
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.184-196
    • /
    • 2020
  • In this paper, a single-bit 2nd-order delta-sigma modulator with the architecture of cascaded-of-integrator feedforward (CIFF) is proposed for precision measurement of current flowing through a secondary cell battery in a battery management system (BMS). The proposed modulator implements two switched capacitor integrators and a single-bit comparator with peripheral circuits such as a non-overlapping clock generator and a bias circuit. The proposed structure is designed to be applied to low-side current sensing method with low common mode input voltage. Using the low-side current measurement method has the advantage of reducing the burden on the circuit design. In addition, the ±30mV input voltage is resolved by the ADC with 15-bit resolution, eliminating the need for an additional programmable gain amplifier (PGA). The proposed a single-bit 2nd-order delta-sigma modulator has been implemented in a 350-nm CMOS process. It achieves 95.46-dB signal-to-noise-and-distortion ratio (SNDR), 96.01-dB spurious-free dynamic range (SFDR), and 15.56-bit effective-number-of-bits (ENOB) with an oversampling ratio (OSR) of 400 for 5-kHz bandwidth. The area and power consumption of the delta-sigma modulator are 670×490 ㎛2 and 414 ㎼, respectively.

Effect of Sternal Closure Method on Sternal Dehiscence With or Without Infection (흉골 봉합 방법이 흉골 열개 및 감염에 미치는 영향)

  • 이삼윤;박권재;고광표;최종범
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.485-489
    • /
    • 2001
  • Background: The most important factor in preventing sternal complications is stable sternal approximation. We have tried to find the most effective sternal closure method by examining the incidence of sternal dehiscence with or without infection in patients with cardiac surgery through median sternotomy. Material and Method: This study was performed in 489 patients over 45 years of age with median sternotomy for open cardiac surgery. Simple closure with interrupted 6 wires was performed in 159 patients, figure-of-8 closure technique in 119, overlapping interrupted closure using 10 wires in 150, and combined closure technique of interrupted simple closure and figure-of-8 suture closure in 61. Two hundred thirty-four patients underwent valve and aortic operations and 213 patients coronary artery bypass surgery. Result: Sternal dehiscence with or without infection occurred in 12 (2.5 %) patients. The complication developed in 5 of 159 patients (3.1%) with six interrupted simple closure, in 4 of 119 patients (3.4%) with figure-of-8 closure, and in 3 of 150 patients (2.0%) with overlapping interrupted closure using 10 wires, but there was no complication in 61 patients with combined closure technique (relative risk for other closure techniques, p<0.05). There was no significant difference in the incidence of the sternal complication between valve and aortic operation group and coronary artery bypass group (3.0% vs 2.3%, not significant), but diabetes mellitus was a significant independent risk factor (odds ratio and multivariate analysis, p<0.05). Conclusion: The sternal closure technique that combines simple interrupted suture closure and figure-of-8 suture closure may be a more useful technique to enhance sternal stabilization compared to other closure techniques, such as simple interrupted closure, 8-figure closure, and overlapping interrupted closure.

  • PDF

Analysis of X-Band Link Performance Degradation Caused by Adjacent Satellite

  • Park, Durk-Jong;Ahn, Sang-Il;Chun, Yong-Sik;Kim, Eun-Kyou
    • Journal of Astronomy and Space Sciences
    • /
    • v.28 no.4
    • /
    • pp.299-304
    • /
    • 2011
  • As more satellites are designed to downlink their observed image data through the X-band frequency band, it is inevitable that the occupied bandwidth of a target satellite will overlap with that of other X-band downlink satellites. For sun-synchronized low earth orbit satellites, in particular, it can be expected that two or more satellites be placed within the looking angle of a ground station antenna at the same time. Due to the overlapping in the frequency band, signals transmitted from the adjacent satellites act as interferers, leading to degraded link performance between target satellite and ground station. In this paper, link analysis was initiated by modeling the radiation pattern of ground station antenna through a validated Jet Propulsion Laboratory peak envelope model. From the relative antenna gain depending on the offset angle from center axis of maximum antenna directivity, the ratio of received interference signal level to the target signal level was calculated. As a result, it was found that the degradation increased when the offset angle was within the first point of radiation pattern. For a 7.3 m antenna, serious link degradation began at an offset angle of 0.4 degrees. From this analysis, the link performance of the coming satellite passes can be recognized, which is helpful to establish an operating procedure that will prevent the ground station from receiving corrupted image data in the event of a degraded link.

Proposed Deterioration-induced Axial Stiffness of Existing Piles in Vertical Extension Structures (수직증축 공동주택 하부 기존말뚝의 열화를 고려한 축강성 제안)

  • Jeong, Sang-Seom;Kim, Do-Hyun;Cho, Hyun-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.25-33
    • /
    • 2019
  • In this study, the axial stiffness of existing piles (Kve) of vertical extension remodeled building was quantified through theoretical and experimental approaches. Theoretically induced upper and lower boundary of the pile axial stiffness was estimated by using the formula proposed by Randolph and Wroth (1978), which can estimate the axial stiffness of rigid and flexible pile subjected under soil confinement. In addition, 38 cases of field measurement data on deteriorated piles with various diameters constructed in the period between 1995 - 1997 were taken in to account by overlapping the field data with the theoretical boundary of the axial stiffness. Through this the maximum axial stiffness of existing pile due to deterioration and long service time was presented for various slenderness ratio (L/D), which can be used in estimating the necessary axial stiffness of reinforcing piles(Kvr) for the vertical extension remodeling. The lower 95% value of the estimated axial stiffness of existing pile will be induced through statistical processing.