• Title/Summary/Keyword: overheating

Search Result 259, Processing Time 0.023 seconds

Evaluation of peri-implant bone density changes in $Br{\aa}nemark$ implants by computer assisted densitometric image analysis (CADIA) (디지털 공제술을 이용한 $Br{\aa}nemark$ 임플란트 주위 골조직 분석)

  • So, Sung-Soo;Noh, Hyuen-Soo;Kim, Chang-Sung;Choi, Seong-Ho;Chae, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.1
    • /
    • pp.137-150
    • /
    • 2007
  • CADIA(Computer-assisted densitometric image analysis) method is used to analyze bone density changes around the implants. The usefullness and reproducibility of the method was assessed. We tried to find out if there is any possibility to quantitiate and qualitify peri-implant bone density change as time passes. And we concluded that this newly developed linear analysis is efficient for analyzing peri-implant bone density change non-Invasively. In this study, 2152 machined $Br{\aa}nemark$ fixtures installed from 1994 to 2002 in the department of Periodontics, Dental hospital of College of Dentistry, Yonsei University were included. Of these fixtures 22 radiographically analyzable failed fixtures were used as experimental group, and 22 successful implants placed in the same patient were used as control group. 1. 57 out of 1635 machined $Br{\aa}nemark$ standard and Mk II implants system failed, the survival rate was 96.5%. And 11 out of 517 machined $Br{\aa}nemark$ Mk III and Mk IV implants system failed, the survival rate was 97.9%. Total survival rate was 96.8%. 2. 22 failed implants were used for the analysis, 10 of which failed before prosthetic treatment due to infection and overheating. 12 failed due to overload after prosthetic treatment, 63.6% of which failed during the early phase of functional loading, i, e. before 1 year of loading. 3. Bone density change values around coronal region of the failed implants were $-6.54{\pm}6.35$, middle region were $-3.53{\pm}5.78$, apical region were $-0.75{\pm}10.33$, resulting in average of $-3.71{\pm}8.03$. 4. Bone density change values around coronal region of the successful implants were $4.25{\pm}4.66$, middle region were $6.33{\pm}5.02$, apical region were $9.89{\pm}4.67$, resulting in average of $6.27{\pm}5.29$. 5. There was a statistically significant difference between two groups (p<0.01). In conclusion, the linear analysis method using computer-assisted densitometric image analysis could be a useful method for the analysis of implants, and could be used for future implant researchs.

Analysis of inner parts in the disc cutters applied to the field tests (현장적용 디스크커터의 내부부품 분석)

  • Bae, Gyu-Jin;Choi, Soon-Wook;Chang, Soo-Ho;Lee, Gyu-Phil;Song, Bong-Chan;Kim, Kab-Boo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.4
    • /
    • pp.473-485
    • /
    • 2015
  • The problems for non-rotating of a disc cutter proceed from the faults in inner parts of the disc cutter such as the leak of hydraulic fluid, the intrusion of tunnel mucks and water, overloading, overheating, poor assembly and substandard material. The rotating of a disc cutter is an indicator to show that the inner parts of disc cutter is operable, although the rotational torque depends on the extent of the damage. Therefore, the key in the problems for non-rotating of disc cutter is to maintain that the tapered roller bearings are working properly. This study aims to investigate the inner parts disassembled from disc cutters applied to the field tests in order to help decision for reuse of the disc cutters. As results, surface finishing to remove the scratch on the load zone of the hubs is needed, with the intent to reuse a hub. And the investigation of lapping surface by optical microscope of floating seals and the contamination test of oil need to be performed for reuse of a disc cutter. Especially, the analysis results show that the floating seals play a key role in the normal operation of bearings. There is nothing significant to report in the rest parts such as bearing, shaft, seal retainers.

Numerical Study on the Cooling Characteristics of a Passive-Type PEMFC Stack (수동공기공급형 고분자 전해질 연료전지 스택에서의 냉각특성에 대한 전산해석 연구)

  • Lee, Jae-Hyuk;Kim, Bo-Sung;Lee, Yong-Taek;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.767-774
    • /
    • 2010
  • In a passive-type PEMFC stack, axial fans operate to supply both oxidant and coolant to cathode side of the stack. It is possible to make a simple system because the passive-type PEMFC stack does not require additional cooling equipment. However, the performance of a cooling system in which water is used as a coolant is better than that of the air-cooling system. To ensure system reliability, it is essential to make cooling system effective by adopting an optimal stack design. In this study, a numerical investigation has been carried out to identify an optimum cooling strategy. Various channel configurations were applied to the test section. The passive-type PEMFC was tested by varying airflow rate distribution at the cathode side and external heat transfer coefficient of the stack. The best cooling performance was achieved when a channel with thick ribs was used, and the overheating at the center of the stack was reduced when a case in which airflow was concentrated at the middle of the stack was used.

Study on Operating Limits of 5.56mm Rifle Overheat - Focusing on Human Engineering (5.56mm 소총 과열에 의한 운용한계 분석 - 인간공학 중심으로)

  • Lee, Ho-Jun;Choi, Si-Young;Shin, Tae-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.49-56
    • /
    • 2020
  • High temperature heat generated during rifle firing not only degrades the performance of the weapon, but also limits the user's operation. In this study, temperature change of handguard according to firing was measured with reference to Human Engineering criteria and the operability according to material was examined. Accordingly, for the firing test, three types of Korean rifle and one overseas model were selected for each material of handguard, and firing test was conducted using a contact type temperature meter. The test result shows that using a plastic handguard with low thermal conductivity and aluminum handguard with high thermal conductivity enabled the rifles to be operated with bare hands even when firing at more than 100 rounds at low atmospheric temperature. However, when firing more than 60 rounds at over 20℃ atmospheric temperature, aluminum handguard use is limited. When firing quickly over 100 rounds, handguard use is restricted regardless of its fabrication material. To eliminate operational limitations by overheating, it is necessary to eliminate direct contact with skin using gloves, vertical grips, etc. This study examined the operability of rifles in terms of thermal risk, and the resulting study results are expected to be used as basic data for Human Engineering of other rifles and munitions.

Using Digital Climate Modeling to Explore Potential Sites for Quality Apple Production (전자기후도를 이용한 고품질 사과생산 후보지역 탐색)

  • Kwon E. Y.;Jung J. E.;Seo H. H.;Yun J. I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.3
    • /
    • pp.170-176
    • /
    • 2004
  • This study was carried out to establish a spatial decision support system for evaluating climatic aspects of a given geographic location in complex terrains with respect to the quality apple production. Monthly climate data from S6 synoptic stations across South Korea were collected for 1971-2000. A digital elevation model (DEM) with a 10-m cell spacing was used to spatially interpolate daily maximum and minimum temperatures based on relevant topoclimatological models applied to Jangsoo county in Korea. For daily minimum temperature, a spatial interpolation scheme accommodating the potential influences of cold air accumulation and the temperature inversion was used. For daily maximum temperature estimation, a spatial interpolation model loaded with the overheating index was used. Freezing risk in January was estimated under the recurrence intervals of 30 years. Frost risk at bud-burst and blossom was also estimated. Fruit quality was evaluated for soluble solids, anthocyanin content, Hunter L and A values, and LID ratio, which were expressed as empirical functions of temperature based on long-term field observations. AU themes were prepared as ArcGlS Grids with a 10-m cell spacing. Analysis showed that 11 percent of the whole land area of Jangsoo county might be suitable for quality 'Fuji' apple production. A computer program (MAPLE) was written to help utilize the results in decision-making for site-selection of new orchards in this region.

A Study on Smart Factory System Design for Screw Machining Management (나사 가공 관리를 위한 스마트팩토리 시스템 설계에 관한 연구)

  • Lee, Eun-Kyu;Kim, Dong-Wan;Lee, Sang-Wan;Kim, Jae-joong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.329-331
    • /
    • 2018
  • In this paper, we propose a monitoring system that starts with the supply of raw materials for threading, is processed into a lathe machine, and checks for defects of the product are automatically performed by the robot with Smart Factory technology through assembly and disassembly. Completion check according to the production instruction quantity and production instruction is made by checking the production status according to whether or not the raw material is worn by the displacement sensor, and checking the pitch and the contour of the processed female and male to determine OK and NG. The robotic system acts as a relay for loading and unloading of raw materials, pallet transfer, and overall process, and it acts as an intermediary for organically driving. The location information of the threaded products is collected by using the non-contact wireless tag and the energy saving system Production efficiency and utilization rate were checked. The environmental sensor collects the air-conditioning environment data (temperature, humidity), measures the temperature and humidity accurately, and checks the quality of product processing. It monitors and monitors the driving hazard level environment (overheating, humidity) of the product. Controls for CNC and robot module PLC as a heterogeneous system.

  • PDF

Thermal Characteristics of Waste Organic Sludges Discharged from an Chemical Product Manufacturing Industry (화학제품제조업에서 배출되는 폐 유기성슬러지의 열적 특성)

  • Kim, Min-Choul;Lee, Gang-Woo;Lee, Man-Sig;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1745-1753
    • /
    • 2008
  • We analyzed the physical and chemical properties such as proximate analysis, ultimate analysis, heating values, thermogravimetric analysis, and combustion test for the organic sludge discharged from chemical and petrochemical product manufacturing industries in the industrial complex. The average combustible and ash content of organic sludges from chemical and petrochemical product manufacturing industries were 17.42%, 7.45%, and 18.25%, 4.22%, respectively. The C, H, O, N, and S compositions for chemical and petrochemical product manufacturing industries were 33.06, 4.34, 24.81, 5.18, and 0.72%. And those compositions for petrochemical product manufacturing industries were 36.58, 4.74, 26.79, 5.09, and 0.49%, respectively. From the TGA test, the minimum temperature for combustion of the sludge discharged from B company was $700^{\circ}C$ for direct use for energy and 2 sludges(F and N companies) were about $600^{\circ}C$. According to the basic combustion test, high concentration of CO was formed because oxidation and pyrolysis reaction take place in the batch type reactor at the same time. From this phenomena we could obtain the significant data for the overheating and breakage of furnace.

A study on the reliability enhancement of Ultrasonic water treatment system to boiler (보일러 초음파 수처리장치의 신뢰성향상에 관한 연구)

  • Kim, Dae-Ryong;Lee, Keun-Oh
    • Journal of Energy Engineering
    • /
    • v.22 no.3
    • /
    • pp.287-293
    • /
    • 2013
  • This study was carried out to diminish the formation of scale in boilers which is one of the defect elements when they are operating. The defect relating to scale can cause a fatal impact on the explosion of boilers due to the overheating of their tubes, or it can affect the flow of water inside boilers with its bad circulation and result in a disparity of water inside the equipment. Heat transfer in the scale is low comparing to the boiler material, so it can lead to energy losses and has also impact on the global warming. In 2005, the Korean government introduced a system which requires boiler users to install the equipment which can prevent or eliminate the formation of scale to improve the management of water quality in boilers. The study on the techniques for preventing or eliminating the formation of scale started in 1821 and since then subsequently there have been lots of similar studies. The first one was about the scale reduction using potato starch. Since an ultrasonic scale preventer developed by a scientist from a Russian acoustic institute was introduced in1993, a variety of equipment of this kind have been disseminated in Korea. There has been a need to demonstrate the condition for the best performances of such equipment. Boilers are mostly composed of the main body and 288 the tube with a circular curved surface. I carried out a demonstration study on a circular tube which affects the scale defect the most among the boiler components. As a result of it, I found out the fact that the ultrasonic wave needs to reach a certain level of sound pressure and frequency to affect the formation of scale.

Fire Examples Study of Intake and Exhaust System, Alternator Tuning and Inflow of Inflammables on Exhaust Part in a Car (자동차 흡배기장치, 발전기 튜닝 및 배기측 인화성 물질 유입에 관련된 화재사례 연구)

  • Lee, Il Kwon;Kook, Chang Ho;Suh, Moon Won;You, Chang Bae;Youm, Kwang Wook;Lim, Chun Moo;Jung, Dong Hwa
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.5
    • /
    • pp.47-51
    • /
    • 2014
  • This paper is to analyze and study the fire examples in respect of intake and exhaust, alternator tuning and inflow of inflammables on exhaust part in a car. In the first example, the driver diverted the intake and exhaust system for tuning of a car. Stopping a car to rest for moment, the flammable styrofoam scrap go into exhaust pipe that installed with exhaust manifold newly. It certified the fact that catched fire gradually, furthermore enlarged the fire by leaking fuel. In the second example, the driver enlarged the generator performance to divert the audio system in side room., it knew the fact that the electric wiring connected with generator gave the cause of outbreak a fire by overheating. In the third example, the serviceman replaced the engine oil using funnel-shaped, he put the a bottle of plastic pat onto engine cover carelessly. Consequentially, it found the fire occurrence in the engine room. Therefore, the driver never divert the intake and exhaust and generator construction of a car abnormally. Also, repairing and inspecting a car, the serviceman have a care to not occur the fire by inflammables.

A Study on Thermal Effects for Structure of Portable Butane Gas Stoves using Oversized Grill (과대불판 사용 시 이동식부탄연소기 구조에 따른 열영향 연구)

  • Choi, Suel-Ki;Kim, Mi-Sung;Jo, Young-Do;Kim, Young-Gu
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.1
    • /
    • pp.87-93
    • /
    • 2017
  • This study was conducted to analyze thermal effects for the structure of portable butane gas stoves in accordance with the introduction of safety standard to protect gas accidents that were caused by using oversized grills. The temperatures of oversized grill, cartridge and cover of cartridge coupling part were measured with stoves that heat sink was installed the inside of cover of cartridge coupling part and had different height of tripods. The trend of measured temperatures affected by thermal effects of grill and flame was analyzed. The condition of using portable butane gas stove safely is that the distance between grill and cover of cartridge coupling part should be about 28 mm and over. In contrast, when the distance between grill and cover of cartridge coupling part would be shorter, thermal effects of not only grill but also flame could affect the cartridge directly. In this case, the danger that could cause gas accident would be higher. When heat sink was installed the inside of cover of cartridge coupling part, it was effective on reducing of thermal effects. However, it still had the danger of explosive gas accident of cartridge due to overheating.