• Title/Summary/Keyword: overheating

Search Result 259, Processing Time 0.025 seconds

A Study on the Safety of Small LPG Storage Tanks at External Fires (외부화재시 LPG 소형저장탱크의 안전성에 관한 연구)

  • Yim, Ji-Pyo;Ma, Byung-Chol;Chung, Chang-Bock
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.64-72
    • /
    • 2015
  • The purpose of this study is to study the safety of a small LPG storage tank with a capacity less than 3 ton when it is exposed to an external fire. First, simulation studies were carried out using ASPEN Plus and PHAST to demonstrate that overpressurization in the tank can be relieved by discharging the LPG through an adequately sized safety valve, but the release may lead to the secondary risk of fire and explosion around the tank. Next, the temporal variations of the temperatures of the lading and tank wall were obtained using AFFTAC, which showed that the tank wall adjacent to the vapor space could be overheated in about 11 min to such a point that the weakened strength might cause a rupture of the tank and subsequent BLEVE. The consequences of the BLEVE were estimated using PHAST. Finally, several practical measures for preventing the hazards of overheating were suggested, including an anti-explosion device, sprinkling system, insulation, heat-proof coating, and enhanced safety factor for tank fabrication. The effectiveness of these measures were examined by simulations using AFFTAC and ASPEN Plus.

Electro-thermal analysis of contacts and connections in VCB under high electric current by finite element methods (유한요소법에 의한 VCB 접속부의 대전류에 대한 전열해석)

  • Kang, Woo-Jong;Huh, Hoon;Kang, Kyeong-Rok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.715-722
    • /
    • 1998
  • A large electric system of a vacuum circuit breaker(VCB) has been studied for the electro-thermal analysis by finite element methods. Since the heat generation in VCB causes not only energy loss but deterioration of the VCB system with oxidization of parts, the overheating of the system must be prevented. For the analysis, a finite element formulation is derived for both electric analysis and thermal analysis that are coupled together. Two sets of formulations are uncoupled after finite dimensional approximation. First, the electric potential is obtained for the entire field and scaled to the given electric current. The electric field obtained is then used to calculate the heat generation in the VCB system including contacts and connections for the calculation of the temperature distribution in the entire domain. The finite element analysis is carried out to study the effect of shapes and locations of contacts and connections. From the results, the existing VCB has been modified to enhance its capacity with reduction of heat generation and temperature elevation.

A study of flow oscillations in a upright heated pipe (직립전열관에서의 유체진동에 관한 연구)

  • 박진길;진강규;오세준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.85-99
    • /
    • 1984
  • The stability of the two-phase flow in a heated channel is of great importance in the design and operation of the boilers and light water nuclear reactors, because it can cause flow oscillations and lead to a violation of thermal limits with resultant overheating of the channels and cladding. This paper presents a systematic evaluation to the variation effects of the basic four (4) dimensionless parameters in a homogeneous equilibrium model. The flow stability is examined on the ground of static characteristic curves. The complicated transfer function of flow dynamics which gives consideration to the transport lag of density wave is derived, and the transient flow stability is analysed by applying the Nyquist stability criterion in control engineering. The analysis results summed up as follows 1. The coolant flow becomes stable in large friction number and specific flow, while it is unstabale in small friction number and flow. 2. Large phase-change number and Froude number destabilize the two-phase flow, but small numbers stabilize it. The effect to variation of phase-change number is more dominant compared with Froude number. 3. The dynamic analysis is required to hold the sufficient safety of heated channels since only static results does not keep it. The special attention could be payed in the design and operation of heat engines, because the unstaable region exists within the stable boundary at small and middle phase-change number and Froude number.

  • PDF

Numerical Analysis of Melting Process in a Water Tank for Fuel-cell Vehicles (연료전지 자동차의 물탱크 해빙과정에 대한 수치해석적 연구)

  • Kim, Hark-Koo;Jeong, Si-Young;Hur, Nahm-Keon;Lim, Tae-Won;Park, Yong-Sun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.585-592
    • /
    • 2007
  • Good cold start characteristics are essential for satisfactory operation of fuel cell vehicles. In this study, the melting process has been numerically investigated for a water tank used in fuel cell vehicles. The 2-D model of the tank containing ice and plate heaters was assumed and the unsteady melting process of the ice was calculated. The enthalpy method was used for the description of the melting process, and a FVM code was used to solve the problem. The feasibility study compared with other experiment showed that the developed program was able to describe the melting process well. From the numerical analysis carried out for different wall temperatures of the pate heaters, some important design factors could be found such as local overheating and pressurization in the tank.

Effect of pre-annealing conditions on critical current density of Bi-2223 tapes

  • Ha, Dong-Woo;Yang, Joo-Saeng;Ha, Hong-Soo;Oh, Sang-Soo;Lee, Dong-Hoon;Hwang, Sun-Yuk;Park, Jung-Gyu;Kwon, Young-Kil
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.31-34
    • /
    • 2003
  • Bi-2223 superconducting wires with 55 filaments were fabricated by stacking, drawing process with different heat-treatment histories. Two kinds of powders were prepared. One was pre-annealed at 760-820 $^{\circ}C$ and low oxygen partial pressure, and the other was only calcined state. Before rolling process, round wires were pre-annealed at 760 -820 $^{\circ}C$ and in a low oxygen partial pressure. We confirmed that pre-annealing step was to transform Bi-2212 orthorhombic structure from Bi-2212 tetragonal structure and to reduce the formation of second phases at superconducting wire. However Bi-2223 phases were formed at higher pre-annealing temperature. Bi-2223 conductor was needed frequently annealing at low temperature because pre-annealing at precursor powder brought about decrease in workability. We could achieve highest Je of 6500 A/$\textrm{cm}^2$ at the tape using Bi-2212 orthorhombic phase by introduced slightly overheating at the 1st sintering process.

Representative Dissolved Gases indicating Aging of Power Transformers (전력용 변압기 경년열화와 관련된 DGA 대표가스에 관한 연구)

  • Kweon, Dongjin;Kim, Yonghyun;Joo, Byoungsoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • The life management technology becomes important as the failure risk of the aged power transformers increases. Asset management technology, therefore, has been developed to evaluate the remaining life and build replacement strategies of power transformers, which enables an optimal investment decisions based on reliability and economic feasibility. The remaining life assessment technology uses data related to such as installation, operation, maintenance, refurbishment, and disposed history of power transformers. The optimal investment decision additionally uses data related to failure and social costs. To develop the asset management technology in power transformers, it is important to find deterioration parameters directly indicating degradation of power transformers. In this study, 110,000 DGA data during the past 35 years have been analyzed in order to find the deterioration parameters related to the degradation of power transformers. The alarm rates of combustible gases ($H_2$, $C_2H_2$, $C_2H_4$, $CH_4$, $C_2H_6$), TCG CO, and $CO_2$ were analyzed as deterioration parameters. The origin of the gas was discussed in connection with discharge, overheating and insulation aging.

A Study on the Improvement of the Separation Phenomenon of Coolant Hose in the Tracked Combat Vehicle (전투차량 냉각수 호스 분리현상 개선에 관한 연구)

  • Kang, Tae-Woo;Shin, Hun-Yong;Ryu, Jeong-Min;Park, Kyung-Chul;Kim, Jae-Kyu;Lee, Hun-kee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.3
    • /
    • pp.59-64
    • /
    • 2018
  • In general, tracked combat vehicles require excellent output performance of a power unit system to drive on special terrains and in extreme environmental conditions. However, high temperature and pressure are readily applied to the coolant hose in the power unit of the vehicles during high-speed driving under extreme road and weather conditions. These driving conditions can cause the separation phenomenon of the coolant hose in the power unit and consequentially engine overheating during driving. Therefore, a newly designed decompression device for the coolant hose has been proposed and manufactured to solve these problems in the present study. To validate of the newly proposed decompression device, the input and output pressures were measured under the before- and after-improvement conditions using experimental methods for different engine RPMs. In addition, the pre-heater temperature was measured under both conditions. From the experimental results, we expect that the current investigation can help to improve the driving performance of tracked combat vehicles.

A Study of Furniture Design Changes Factors Appearing in the Industrialization Process - Focused on the Korea Furniture Industry, 1960~2010 Year - (산업화 과정에서 나타나는 가구디자인 변화 요인 연구 - 1960년대에서 2010년대까지 한국 가구산업을 중심으로 -)

  • Kim, Kyoung Soo
    • Journal of the Korea Furniture Society
    • /
    • v.27 no.4
    • /
    • pp.399-411
    • /
    • 2016
  • Korea Furniture design development process is repeated a number of changes by the change of residence and type of market demand derived from the process of industrialization. The modernization process of industrialization advances by large-scale population moves to the city to urbanization proceeds rapidly. Housing problems are concentrated in cities and sparked the furniture industry, furniture design by changes in marketing concepts that appear in the industrialization phase, growth must necessarily accommodate the needs of consumers. Including kitchen furniture, living room furniture and master bedroom furniture has been sensitively adapted changes in the structure of these houses, particularly structural changes Apartments. Starting in the 1990s, jumping over furniture industry has adapted quickly to the market demand, changes in marketing concepts. Furniture industry is growing market share in most of the country, but the entire industry had to undergo a competitive marketing overheating due to excessive supply in excess of market demand since the mid-1990s. Changes in furniture design in this process was the change in furniture design more than the change of the residential structure. The study industrial development and marketing concepts are changing to construct a model to track the changes varied styles and time changes affect whether the main furniture design.

Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City (에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로)

  • Kim, Sung-Sam
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

Compatibility Assessment of Copper Alloy and Hydrocarbon Fuel for Regeneratively Cooled Combustion Chamber (재생냉각 연소기용 구리합금과 연료 적합성 검증시험)

  • Lim Byoung-Jik;Kim Jong-Gyu;Kang Dong-Hyuk;Kim Hong-Jip;Kim Hui-Tae;Han Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.100-109
    • /
    • 2006
  • In the regeneratively cooled combustion chambers using hydrocarbon fuels, coking occurs as the wall temperature increases which generates compounds deposition on the wall. This phenomenon reduces cooling capability of the coolant, finally it can cause damage to combustor by overheating of chamber wall. In this paper electrical heating equipment which is used for the coking experiments and the test results are introduced. The compatibilities of copper alloy with let A-1 were assessed at each condition based on the test results.

  • PDF