• Title/Summary/Keyword: over-pressure

Search Result 3,652, Processing Time 0.03 seconds

Permeation Behavior of Microfiltration Membrane by Alumina Colloidal Suspension under a Cyclic Variation in TMP (운전압력의 순환변화에 따른 알루미나 현탁액의 정밀여과 투과거동)

  • Nam, Suk-Tae;Han, Myeong-Jin
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.13-21
    • /
    • 2011
  • This study investigated the fouling behavior of $Al_2O_3$ colloids on polyethylene microfiltration membrane. To examine the effect of operation variation on fouling, operating pressure was increased from 0.49 to 1.96 bar along with time elapses and then was reduced to 0.49 bar reversely. A hysteresis behavior was observed in the membrane permeate flux over pressure, revealing different fluxes at the same pressure according to the pressure control type, increasing and decreasing. Permeate resistance and its rate of increase was higher in the decreasing pressure cycle than in the increasing pressure cycle. At the initial period of filtration, fouling mechanism for the both cycles was governed by the cake filtration. The degree of fouling was higher in the decreasing pressure cycle compared with in the increasing pressure cycle.

Effect of annealing time on MOD-YBCO films at reduced total pressure (저압공정을 이용한 MOD-YBCO 박막의 열처리 시간 효과)

  • Chung Kook-Chae;Yoo Jai-Moo;Ko Jae-Woong;Kim Young-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.3
    • /
    • pp.5-8
    • /
    • 2006
  • The effect of annealing time in Metal Organic Deposition(MOD) method was investigated at reduced total pressure. As the total annealing pressure was reduced, the growth rate of YBCO films increased from 0.14nm/sec at atmospheric pressure to 4.2nm/sec at 1 Torr. For the total pres sure of 700, 500, 300, 100, and 1 Torr, the optimal annealing times of 60, 40, 20, 10, 2minutes were found in our experimental conditions. When the an nealing time was short, poor crystallinity or un-reacted phase was obtained. Also, the degradation of YBCO films occurred when exposed longer to the humid ambient at the high annealing temperature. The reduced pressure was found effective to in crease the growth rate and to control the pore size of the YBCO films in MOD method. A fast growth of MOD-YBCO films was realized with high critical current density over $1MA/cm^2$ using reduced pressure annealing. Large pores, usually observed at atmospheric pressure in MOD method, disappeared and also, the number of pores was reduced.

Analysis on Volumetric Efficiency and Torque Characteristics Using Inlet Port Pressure in SI Engines (흡기포트압력을 이용한 SI엔진의 체적효율 및 토크 성능 분석)

  • 이영주;홍성준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1408-1418
    • /
    • 1992
  • The valve timing and intake system in SI engine is chosen in order to get the maximum performance at the target rpm. This is a compromise and the performance reduction is expected in a certain rpm range. Therefore, to accomplish the possible engine capacity all over the operation ranges, it is required to investigate the effects of intake system and valve timing on engines more thoroughly. In this paper, it was attempted to examine closely the combined effects on the torque and the volumetric efficiency due to the change of valve timing and intake system dimensions. For this, the inlet port pressure was chosen as a primary parameter to represent engine performance characteristics together with surge tank pressure and induction pressure as secondaries. The inlet port pressure was analyzed in connection with both the secondaries and the performance data. Especially the relation between the inlet port pressure and the torque and volumetric efficiency was investigated on the operating conditions. In this experiment, it was acquired that the performances at specific rpm range could be improved by the combinations of valve timing and intake system. Then it was verified that pressure at a intake system contained useful data for the engine performance. By the analysis of inlet port pressure with the others, it was obtained that the properties of the torque and the volumetric efficiency due to the change of valve timing and intake conditions were able to be defined by the average and the maximum inlet port pressures, the pressure near before the intake valve closing(IVC) point as well as the pressure at IVC point during the intake valve opening duration. These results could be applied to almost all over the experimental conditions.

A Study on the Relationship between Health Behavior Factors and Blood Pressure of Workers (혈압 건강군과 비건강군 근로자의 건강실천 관련 요인 조사연구)

  • Choi Hyun-Ju;Jung Moon-Hee;Kim Yoon-Shin
    • Journal of Korean Public Health Nursing
    • /
    • v.18 no.2
    • /
    • pp.312-329
    • /
    • 2004
  • This study was examined 718 workers who had consistent blood pressure results in 2001 and 2002 general health examinations that were held at a work places managed by a health care agency in Seoul. Significant results are found as follows by analysing SPSS 11.0 on the result of self-recorded questionnaires investigated from Mar 1, 2003 to April 30, 2003. 1. A sampled healthy group and a sampled unhealthy group had significant differences in four variables out of possible nineteens that are sex, age, marriage and occupation. The unhealthy group had more males than females, more aged (over 50 years old) than youngers (under 50 years old), more married than singles, more manufacturing workers than non-manufacturing workers. In the case of systolic blood pressure, as the healthy group had 16.52mmHg while that of the other group had 149. 58mmHg, 33.06mmHg of difference between those groups were detected. In the case of diastolic blood pressure, 74.93mmHg of the healthy group and 96.53mmHg of the unhealthy group yielded 21.60mmHg of difference between them. This result implies that a guidance of health care is required to be aware of 20-30mmHg volatility in blood pressure rate or to understand and treat properly own blood pressure. as it is difficult to detect hypertension in early stage due to no initial symptom. According to the result. an establishment of management system of workers, companies and health care agencies is required for consist health care. 2. In terms of risky habits to health, the unhealthy group had more proportion of past smokers, over-twice-a-week drinkers, people with higher obesity rate. However, in terms of excercise, the proportion of regularly exercising people is higher in the unhealthy group while that of non-exercising people is higher in the healthy group. On the other hand. the average grade of health practicing behaviour in two groups are not significantly different as the health group had 3.00 out of possible 6.00 while the other had 3.10. This result means that as workers are not interested in health practicing behaviour. health promoting programmes must be developed in such a way of various method of motivations and incentives. Particularly this implies that distortional objectives of exercises should be readjusted through health guidance. 3. Systolic blood pressure in the healthy group can be explained by sex and the obesity rate while that in the unhealthy group can be explained by subjective health awareness and the obesity. Diastolic blood pressure in the healthy group can be explained by sex and the obesity rate like the former. The obesity rate was significant variable affecting the blood pressure of both groups, and particularly the effect to the unhealthy group was remarkably higher than that to the healthy group. Therefore, this research identified that the health care on the blood pressure of workers is not only limited to hypertension patients, but also extended to all workers. In order for consistent care, an establishment of management system of workers, companies and health care agencies is required.

  • PDF

Foot/Ankle Roll-Over Characteristics According to Different Heel Heights of Shoe during Walking (보행 시 신발 굴 높이어 따른 발/발목 복합체의 Roll-Over특성)

  • Kim, Young-Ho;Choi, Hue-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.247-253
    • /
    • 2005
  • This study investigated the effects on foot and ankle roll-over characteristics according to different heel heights during walking. Fifteen female volunteers who have neither musculoskeletal nor foot problems were participated in gait analyses, wearing four different pairs of shoes in different heel heights. To obtain roll-over shape of foot/ankle complex, we used trajectories of knee and ankle joints as well as the renter of pressure between initial contact and opposite initial contact. Results revealed that the entire roll-over shape moved distally as the heel height increased but roll-over characteristics showed uniformly with different heel heights. In addition, we found that nondisablea persons automatically adapted to their foot/ankle complex to varying heel heights within 6cm, by moving the origin of roll-over shape distally to maintain roll-over characteristics. However, since the balance of the gait only by the ankle joint could not be achieved beyond the heel height of 6cm, compensations at the knee and the hip joints occurred simultaneously. Roll-over characteristics in human walking would provide simpler and wider understanding of human walking, and furthermore could be applied to the wide understanding of prosthetics and orthotics of the lower extremity as well as orthopaedic shoes.

A Study on the Characteristic of Contact Pressure for CPB (Cold Pad Batch) Padder Roll Controlled by Hydraulic Single Cell (단일 유압 Cell로 제어되는 CPB(Cold Pad Batch)용 패더롤의 접촉압력 특성 연구)

  • Cho, Kyung-Chul;Lee, Eun-Ha;Jo, Soon-Ok;Park, Si-Woo;Hwang, Youn-Sung;Kim, Soo-Youn
    • Textile Coloration and Finishing
    • /
    • v.29 no.2
    • /
    • pp.86-96
    • /
    • 2017
  • To make uniform pressure distributed over the contact surface was necessary to cold pad batch dyeing machine. In this study, to confirm characteristic of flexibility and the contact pressure distribution through experimental analysis of padder roll were controlled by hydraulic cell. When there were no load pressure only inner pressure, the value of displacement in the center of padder were greater than the end of the padder. The results of this study showed that the padder had the optimum value of inner pressure for uniform contact pressure distribution. Measuring the contact pressure in a padder system were driven by using a pre-scale film. Uniform contact pressure distribution of cell padder were a linearly with load pressure and inner pressure. When the load pressure was less than 8 tons, the inner pressure for the uniform contact pressure was 1~4 bar. The padder roll performance curves proposed in this study were available for practical production environments and various roll designs.

The utility of ambulatory blood pressure monitoring in obese children (소아 비만아에서 ambulatory blood pressure monitoring의 유용성)

  • Kim, Myung Jin;Song, Jin Young
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.6
    • /
    • pp.604-609
    • /
    • 2008
  • Purpose : Obesity in children and adolescence is highly correlated with adult obesity, which can provoke hypertension. Therefore, it is important to evaluate the blood pressure of obese children regularly. In this study, the results of ambulatory blood pressure monitoring (ABPM) in obese children and adolescents were evaluated. Methods : ABPM was conducted for selected patients who visited Handong University Sunlin Hospital from Feb. 1, 2006 to Dec. 1, 2007. The patients were classified into 3 groups: group 1 was normal, group 2 had normal casual blood pressure and a body mass index over the 95th percentile, and group 3 had high casual blood pressure over 120/80 mm Hg and a body mass index over the 95th percentile. Systolic and diastolic 24-hour blood pressure was measured, including both day and night. Results : There were 49 patients in the study. The results showed a significant difference for average systolic blood pressure between the three groups ($105.1{\pm}4.7$, $111.0{\pm}7.1$, $117.8{\pm}6.6mmHg$, P<0.001), but for average diastolic blood pressure only between groups 1 and 3 ($69.1{\pm}5.3$, $77.9{\pm}6.3mmHg$, P=0.001). In the daytime, only groups 1 and 3 showed a statistically significant difference for systolic and diastolic blood pressure. During the night the systolic pressure of group 3 was significantly higher than the other groups, but the diastolic pressure of group 3 was only higher than that group 1. No statistical difference was found in night dips among the groups. Conclusion : Ambulatory blood pressure monitoring in children and adolescents showed statistically higher blood pressure in obese patients with high casual blood pressure.

Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection (합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현)

  • Park, No-Jin;Yu, Dong-Kuen;Yu, Hong-Kuen
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

Blood Lead Concentration and Hypertension in Korean Adults Aged 40 and Over According to KNHANES IV (2008) (40세 이상의 한국성인의 혈중 납 농도와 고혈압 - 2008년 국민건강영양조사를 바탕으로 -)

  • Kim, Sun-Young;Lee, Duk-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.6
    • /
    • pp.418-428
    • /
    • 2011
  • Objectives: The purpose of this study was to examine the cross-sectional relationship between low blood lead levels and increasing blood pressure among Korean adults using a nationally representative sample of the Korean population: the Korea National Health and Nutrition Examination Survey (KNHANES) 2008. Methods: A total of 918 subjects aged 40 and older and not currently being treated for hypertension participated in this study. Information about age, gender, smoking status, alcohol consumption, education level, and the use of anti-hypertensive medication was collected. The blood pressure was defined as the mean of the second and the third measurements after three time measurements. Lead levels were determined by an analysis of blood samples. Multiple linear and logistic regression analyses were implemented after adjusting for covariates including age, gender, educational level, smoking status, alcohol consumption, and BMI. Results: This study showed that the average differences in systolic and diastolic blood pressure comparing the lowest to highest quintile of blood lead were 4.33 mmHg (95% CI, 0.66-8.00; p for trend = 0.027) and 2.66 mmHg (95% CI, 0.26-5.06; p for trend = 0.021), respectively. After multivariate adjustment for covariates, the prevalence odds ratio (POR) of subjects in the highest quintile was associated with a 1.70-fold increase in the risks of hypertension (95% CI, 0.83-3.49; p for trend test = 0.112) over those in the lowest quintile of blood lead concentration, However, it was not statistically significant. Conclusions: This study provided evidence for an association between low- levels of blood lead and elevations in blood pressure and risk for hypertension in the general population of Korea.

Analysis on the Dielectric Characteristics of Dry Air According to Pressures for Developing an Eco-friendly High Voltage Switchgear (친환경 고압배전반 개발을 위한 dry air의 압력별 절연내력특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1560-1565
    • /
    • 2011
  • The environmental pollution caused by green-house gases such as $CO_2$ and $SF_6$ has been becoming the main issue of industrial society. Many developed countries are making efforts to minimize the amount of $CO_2$ emission come from the operation of high voltage electrical apparatuses. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions. Nowadays, the study on the development of dry air insulated switchgear (DAIS) which is known as an eco-friendly electrical apparatus is in progress. A DAIS is advantageous for minimizing the effect of impurities and enhancing the dielectric characteristics over an air insulated switchgear (AIS) by applying constant pressure to an enclosed cubicle. Therefore, a study on the electrical insulation performance of dry air as a gaseous insulation medium is conducted in this paper to substitute a gas insulated switchgear (GIS) for DAIS. As results, it is verified that the AC dielectric characteristics of dry air are similar to those of air and the lightning impulse dielectric characteristics of dry air are superior to those of air at 1bar pressure condition. However, dry air is of inferior dielectric characteristics to $SF_6$ at 4bar pressure condition. Finally, it is suggested that the internal pressure of DAIS should be over 4bar pressure to develop a high voltage switchgear which has similar electrical performance to a conventional GIS. Also, the empirical formulae on calculating the maximum electric field intensity at sparkover of dry air are deduced by experiments according to pressures. It is expected that these results are helpful to design and develop a high voltage electrical apparatus.