• Title/Summary/Keyword: over-pressure

Search Result 3,651, Processing Time 0.029 seconds

Wake Flow Characteristics around the Side Mirror of a Passenger Car (승용차 외장측면거울 주위의 유동 특성)

  • Han, Yong-Oun;Kim, Jung-Hyun;Hwang, In-Ho;Seo, Jung-Bok;Lim, Byung-Hoon;Jung, Ui-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2573-2578
    • /
    • 2007
  • In order to investigate the vortex body frame interaction around the side mirror of a passenger car, velocity vector fields in the wake, pressure distributions and boundary layer flows over both the mirror surface and the mirror housing, have been measured by several experimental tools. It was resulted that only within an half downstream distance of the mirror span there appears the recirculation zone, and also found that vortex trail towards to the driver side window between A and B pillars, making the acoustic noise and vibration. Wake vortex rolls up after this recirculating zone and makes the trail of the vortex center towards the driver side window, which was also confirmed by measurements of wake velocity vectors in the vertical sections of the trail and visualization over the side mirror surfaces as well. It was also observed that total pressure distribution over the mirror surface has the minimum peak near the lower tip region which can be considered as the origin of the vortex center. It can be concluded that the geometrical modification of the lower tip and the upper root area of the mirror housing is the key to control the wake vortex.

  • PDF

An Experimental Study on the Characteristics of Rectangular Supersonic Jet on a Flat Plate

  • Kwak, Ji-Young;Lee, Yeol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.324-331
    • /
    • 2016
  • The present study focuses on the characteristics of a supersonic jet flowing from a rectangular nozzle exit on a flat plate. Flow visualization techniques using schlieren and kerosene-lampblack tracing are utilized to investigate shock reflection structures and boundary-layer separations over a flat plate. Wall pressure measurements are also carried out to quantitatively analyze the flow structures. All observations are repeated for multiple jet flow boundary conditions by varying the flap length and nozzle pressure ratio. The experimental results show that the jet flow structures over the flat plate are highly three-dimensional with strong bleeding flows from the plate sides, and that they are sensitive to plate length and nozzle pressure ratio. A multi-component force measurement device is also utilized to observe the characteristics of the jet flow thrust vectoring over the plate. The maximum thrust deflection angle of the jet is about $8^{\circ}$, demonstrating the applicability of thrust vector control via a flat plate installed at the nozzle exit.

Injury and inflammation detection by the application of microcurrent through the skin

  • Hui, Timothy;Petrofsky, Jerrold
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Objective: To determine the efficacy and reliability of measuring direct current microcurrent applied through the skin to determine injury in the underlying tissues. Design: Case control study. Methods: First, microcurrent was measured as decreased blood flow induced hypoxia in healthy subjects. Next, reliability was assessed by measuring over ten days with set variations in pressure and distance between the electrodes. Finally, measurements over sprained ankle were compared to measurements over comparable uninjured areas on the same injured subject. Results: For the blood flow test phase, microcurrent significantly decreased an average of 17% after 5 minutes (p<0.05), remained decreased for 30 seconds, and returned to non-occlusive levels after 2 minutes of normal circulation. The results indicate that the microcurrent decrease was not due to blood flow, and most likely from hypoxic cellular damage. For the reliability phase, the coefficients of variation averaged 10.3% for the shoulder, 14.8% for the low back, and 29.1% for the knee. Changing distance 2.5 cm between the electrodes resulted in insignificant changes. Changes in pressure had some significant effect after an increase in force of 2.6 N, affirming the need for consistent pressure for measurement. For the injury test phase, a significant 69% decrease occurred comparing injured areas to the same area on the uninjured side, and a significant 74% occurred comparing injured and non-injured areas on the same limb. Conclusions: Microcurrent through the skin shows promise as an objective method of assessing a soft tissue injury by detecting damage likely due to hypoxia.

  • PDF

Prediction of Off-line Type Pulse Air Jet Bag Filter Reflection Distance (간헐탈진형 충격기류식 여과집진장치의 여과포 반사거리 예측)

  • Jeong-Sam Son;Yong-Hyun Chung;Jeong-Min Suh
    • Journal of Environmental Science International
    • /
    • v.32 no.11
    • /
    • pp.801-809
    • /
    • 2023
  • The purpose of this study is to predict the reflection distance following to the pulsing pressure, total air supplying, filter bag size using numercial analysis techniques and use it as an efficient operation condition and economic data for off-line type pulse air jet bag filter. In this research, filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the main experiments using coke dust. Ansys fluent V19.0 apply to CFD simulation, and analysis pulsing characteristics about pulsing pressure, filtration velocity and nozzle diameter. The maximum reflecting distance of off-line type pulse air jet bag filter is 1,000 mm regardless of total air supplying at over the 42 L/m2 conditions, that indicates off-line type can extend filter bag length 1,000 mm than on-line type. In order to effective primary and secondary pulsing of off-line type pulse air jet bag filter, over the 5 bar of pulsing pressure and over the 42 L/m2 of total air supplying are needed.

The Effect of Plantar Foot Pressure Negotitating Obstacles in the Elderly

  • Seo, Kyo-Chul;Kim, Hyeun-Ae;Kim, Hee-Tak;Kim, Sung-Gyung;Kim, Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.6
    • /
    • pp.15-22
    • /
    • 2011
  • Purpose: This research investigated falls due to obstacles that occur among elderly people by assessing changes in the values of plantar foot force, peak force, and plantar foot pressure in elderly subjects while they were stepping over obstacles of different heights. Methods: The subjects were 20 elderly people aged 70-80 years; Pressure was measured on flat ground(0 cm), and after installing obstacles of 8 cm and 12 cm using the F-scan system, which is a resistance-type pressure sensor. A one-way analysis of variance was performed to compare pressure on each part of the foot according to various heights after collecting data using the Tekscan program. The least significant difference test was used for the post-hoc analysis, A p-value <0.05 was considered significant. Results: The force value for the toe area (parts 1, and 2) and contact pressure increased significantly with the 12 cm obstacle (p<0.05). The peak force value and the peak contact pressure for part 1 increased significantly with the 12 cm obstacle (p<0.05). Conclusion: Larger changes appeared in the functions and structure of the foot while subjects walked over obstacles of different heights compared to flatland walking. This result suggests that people have safety strategies to prevent falls, and that there is a need for a more realistic approach through practice to overcome obstacles of various heights to prevent falls.

A Study of the Effects of SST Deviations on Heavy Snowfall over the Yellow Sea (해수면 온도 변화가 서해상 강설에 미치는 영향 연구)

  • Jeong, Jaein;Park, Rokjin
    • Atmosphere
    • /
    • v.23 no.2
    • /
    • pp.161-169
    • /
    • 2013
  • We examine the effects of the sea surface temperature (SST) distribution on heavy snowfall over the Yellow Sea using high-resolution SST products and WRF (Weather Research and Forecasting) model simulations in 30 December 2010. First, we evaluate the model by comparing the simulated and observed fresh snowfall over the Korean peninsula (Ho-Nam province). The comparison shows that the model reproduces the distributions and magnitudes of the observed snowfall. We then conduct sensitivity model simulations where SST perturbations by ${\pm}1.1^{\circ}C$ relative to baseline SST values (averaged SST for $5{\sim}15^{\circ}C$) are uniformly specified over the region of interest. Results show that ${\pm}1.1^{\circ}C$ SST perturbation simulations result in changes of air temperature by $+0.37/-0.38^{\circ}C$, and by ${\pm}0.31^{\circ}C$ hPa for sea level pressure, respectively, relative to the baseline simulation. Atmospheric responses to SST perturbations are found to be relatively linear. The changes in SST appear to perturb precipitation variability accounting for 10% of snow and graupel, and 18% of snowfall over the Yellow Sea and Ho- Nam province, respectively. We find that anomalies of air temperature, pressure, and hydrometeors due to SST perturbation propagate to the upper part of cloud top up to 500 hPa and show symmetric responses with respect to SST changes.

Application of the Polar Parabolic Equation Method for Sound Propagation over a Smooth Sea Mountain in the Ocean (해저구릉 위로의 음의 전파를 설명하기 위한 Polar PE의 적용)

  • You, Chul-Soo;Yoon, Suk-Wang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2E
    • /
    • pp.37-42
    • /
    • 1995
  • The polar parabolic equation method (Polar PE) which introduces a series of "cascaded" boundary fitting coordinates into the parabolic equation method has been verified as a good numerical method for atmospheric sound propagation over a curved surface and hills. Polar PE is applied here to underwater sound propagation over a sea mountain assuming locally reacting boundary sea bottom and pressure release water surface for the boundary conditions. Calculations are presented for underwater propagation over a 450 m high sea mountain. Feasibility of Polar PE application for underwater sound propagation over a smooth mountain is discussed.

  • PDF

Characteristics of East Asia Synoptic Meteorological Conditions in Association with Haze phenomena (연무와 연관된 동아시아의 종관기상 특성)

  • Jo, Hyun-Young;Kim, Cheol-Hee
    • Atmosphere
    • /
    • v.20 no.2
    • /
    • pp.161-172
    • /
    • 2010
  • In an effort to investigate the characteristics of synoptic meteorological conditions in association with long-range transport of haze phenomena occurred over Korea, we statistically classified characteristics of haze events into two types of haze: stagnant case and long-range transport case, based on the synoptic meteorological parameters, and analyze comparatively the characteristics of synoptic meteorological conditions for each case. The results showed that the occurrence frequency of stagnant case accounts for 64.5%, showing superiority of stagnant haze cases over the long-range transport case which occupies only 35.5% among total 67 cases for the period from 2000 to 2007. This result indicates that haze phenomena occurred over Korea has influenced by not only the emission in Korea by itself but long range transport effects originating from China inland. The synoptic condition on 850hPa level showed that, when stagnant case occurred, Korean peninsula was located under the effects of negative vorticity with the significantly weak wind speed and stable atmospheric condition. In contrast, long-range transport case shows positive vorticity and relatively strong wind speed over 850hPa level, especially with the location of high pressure system over the area of southwestern China. This location of high pressure system implies to induce the westerlies or northwesteries consistently due to its pressure gradient by itself. Also other comparative studies haze days (vs.) Asian dust days are carried out, and we found out that the patterns of long-range transport of haze phenomena in Korea shows similar to Asian dust case but the static stability condition indicates more stabilized atmospheric condition than dust phenomena.

Effect on postoperative pulmonary arterial pressure with preoperative hemodynamic data in VSD (심실중격결손증에서 수술전 혈류역학치가 수술후 폐동맥압력에 미치는 영향)

  • 성숙환
    • Journal of Chest Surgery
    • /
    • v.19 no.2
    • /
    • pp.238-242
    • /
    • 1986
  • The prognosis of patients with VSD and pulmonary hypertension is at least partially related to the reversibility of pulmonary hypertension after surgery. To predict postoperative pulmonary arterial pressure, immediate postbypass values were compared with preoperative hemodynamic data in 18 surgically closed VSD patients aged 6 to 80 months. The following results were obtained. 2] There was a good correlation between preoperative PP/PS and postoperative PP/PS in patients aged over 24 months [r=0.685, p<0.05], and in patients whose QP/QS were over 2.0 [r=0.686, p<0.01]. 3] There was also a good correlation between pump time and postoperative PP in total patients [r=0.697, p<0.005]. 4] Direct correlations were found between preoperative PP/PS and immediate postbypass PP/PS in patients aged over 24 months and in patients whose QP/QS>2.0, but the effect of CPB would participate in some degree. So it may be necessary to reevaluate their relationship after the effect of CPB have been disappeared.

  • PDF

Experimental Investigation of R-22 Condensation in Tubes with Small Inner Diameter

  • Kim, Nae-Hyun;Cho, Jin-Pyo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.45-54
    • /
    • 1999
  • In this study, condensation heat transfer experiments were conducted in two small diameter (ø17.5, ø4.0) tubes. Comparison with the existing in-tube condensation heat transfer correlations indicated that these correlations over predict the present data. For example, Akers correlation over predicted the data up to 104 %. The condensation heat transfer coefficient of the ø4.0 I.D. tube was smaller than that of the ø7.5 I.D tube; at the mass velocity of 300 kg/$m^2$s, the difference was 12 %. The pressure drop data of the small diameter tubes were highly (two to six times) over predicted by the Lockhart-Martinelli correlation. Sub-cooled forced convection heat transfer test confirmed that Gnielinski's single phase heat transfer correlation predicted the data reasonably well.

  • PDF