• 제목/요약/키워드: over current characteristics

검색결과 1,158건 처리시간 0.026초

질화와 재산화를 이용한 얇은 게이트 산화막의 질적 향상 (Improvement of Thin-Gate Oxide using Nitridation and Reoxidation)

  • 이정석;장창덕;이용재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.1-4
    • /
    • 1998
  • In this paper, we have studied a variation of I-V characteristics, and time-dependent dielectric breakdown(TDDB) of thin layer NO and ONO film depending on nitridation and reoxidation time, respectively, and measured a variation of leakage current and charge-to-breakdown(Q$\_$bd/) of optimized NO and ONO film depending on ambient temperature, and then compared with the properties of conventional SiO$_2$. From the results, we find that these NO and ONO thin films are strongly influenced by process time and the optimized ONO film shows superior dielectric characteristics, and Q$\_$bd/ performance over the NO film and SiO$_2$, while maintaining a similar electric field dependence compared with NO layer.

  • PDF

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

Mobile IPv6망에서 DiffServ 와 매체접근 우선권을 이용한 QoS에 관한 연구 (The Study of QoS Using DiffServ and MAC Priority in Mobile IPv6 Network)

  • 손성찬;오정균
    • 정보통신설비학회논문지
    • /
    • 제7권1호
    • /
    • pp.33-39
    • /
    • 2007
  • Recently there are increasing needs for Internet and various kinds of contents. These traffics for various contents need more amount of data to provide high-quality information and require various QoS depending on the characteristics of contents. However, current Internet service supports BE (Best Effort) service only, therefore IntServ (Integrated Service) scheme and DiffServ (Differentiated Service) scheme are represented to support QoS in IP layer. This paper describes new scheme that provides QoS taking into account the traffic characteristics over Mobile IPv6 network based on IEEE 802.11e by decreasing signal process time using traffic class of DiffServ and MAC and evaluates the performance through computer simulation.

  • PDF

고온초전도변압기의 특성시험 (Test of an High Temperature Superconducting Power Transformer)

  • 이희준;차귀수;이지광;김우석;한송엽;류경우;최경달
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권9호
    • /
    • pp.572-577
    • /
    • 2000
  • This paper describes the test results of a single phase 3kVA high temperature superconducting power transformer. The tapes are made with Bi-2223 and have silver alloy as the matrix. Four double pancake windings are used. Among them two double pancake windings are connected in series for high voltage winding and the others are connected in parallel for low voltage winding. The rated voltage and current of primary winding and secondary winding are 220/110V. 13.7/27.3A. Fundamental characteristics are obtained through short circuit and no load test. The over load capability and characteristics are investigated.

  • PDF

회전기 고정자 권선의 부분방전 측정용 RFCT 특성 (Characteristics of RFCT for Partial Discharge Measurement in the Stator Winding of Rotating Machines)

  • 강동식;윤대희;황돈하;김용주;장기찬;송상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1616-1618
    • /
    • 2001
  • In recent the on-line partial discharge (PD) measurement using sensors, such as EMC, SSC, RTD and RFCT, as an indicator of stator winding insulation condition has been developed. RFCT sensor was placed arounding a grounding lead of surge capacitor to detecting PD. Trend of PD magnitude/phase angle/pulse number over time are useful parameter to diagnosis aging state. We have developed Radio Frequency Current Transformer(RFCT) sensor which is suitable for PD diagnostic measurement in 6.6kV rotating machines. In this paper, we describe the characteristics of RFCT sensor, such as frequency and PD magnitude using 6.6 kV model stator winding in Lab.

  • PDF

전부하 상태에서 소형 엔진의 성능 및 배기특성 (Performance and Emissions Characteristics of Small Engine at WOT Condition)

  • 박상규;김병국;오진우;최영하;김동선;윤석주
    • 한국분무공학회지
    • /
    • 제13권2호
    • /
    • pp.85-90
    • /
    • 2008
  • This paper presents the performance and emissions characteristics of a small spark-ignited gasoline engine. The engine used in this paper is a single cylinder, diaphragm carburetor, two-stroke, air-cooled 26cc SI engine for brush cutter. For the performance of the engine, RPM, torque, and fuel consumption were measured and HC, CO, and NOx measured for the emissions according to the change of the dynamometer load at wide open throttle (WOT) position. The results showed that the excess air ratio decreased and torque increased with increasing loads, the torque and brake specific fuel consumption were the optimum driving condition at the 7000 rpm, HC and CO emissions increased with increasing loads and with an decrease in excess air ratio over 7000 rpm.

  • PDF

마이크로그리드 적용을 위한 마이크로터빈 기반 마이크로소스의 EMTP 모델링과 동특성 시뮬레이션 (EMTP Modeling and Dynamic Analysis of Microturbine Based Microsource for Application to Microgrid)

  • 정태영;백영식
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.42-48
    • /
    • 2009
  • Microgrid supplies loads with power interconnected grid. And it is defined a independent power system compounded micro sources over two devices which have enough capacity to operate independently, storage devices and loads. The energy sources of micro source have different dynamic characteristics corresponding to classes and application skills. However their transient responses are various from a few seconds to minutes. Therefore it is limitation for understanding operation characteristics of microsource modeling constant voltage source or constant current source. This paper shows that we designed EMTP/RV model of micro source which is microturbine based energy source. And we performed dynamic analysis of micro source corresponding to operation mode of microgrid.

서브미크론 MESFET의 DC 특성 (The DC Characteristics of Submicron MESFEFs)

  • 임행상;손일두;홍순석
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권10호
    • /
    • pp.1000-1004
    • /
    • 1997
  • In this paper the current-voltage characteristics of a submicron GaAs MESFET is simulated by using the self-consistent ensemble Monte Carlo method. The numerical algorithm employed in solving the two-dimensional Poisson equation is the successive over-relaxation(SOR) method. The total number of employed superparticles is about 1000 and the field adjusting time is 10fs. To obtain the steady-state results the simulation is performed for 10ps at each bias condition. The simulation results show the average electron velocity is modified by the gate voltage.

  • PDF

Poly(1-methyl-4-vinylpyridium iodide-co-styrene)막을 통한 유기음이온의 투과특성 (Transport Characteristics of Organic Anions through Poly (1-methyl-4vinylpyridium iodide-co-styrene) Membrane)

  • 이광재;한정우박돈희조영일
    • KSBB Journal
    • /
    • 제6권2호
    • /
    • pp.207-213
    • /
    • 1991
  • In this study poly (1-methyl-4-vinylpyridinium iodide-co-styrene) membrane with pyridinium cation as a fixed carrier was synthesized and the transport characteristics of the membrane was examined over various factors. As the concentration of the fixed carrier in the membrane was increased, the water content was increased. Meanwhile, the counter current of the organic anion and the chloride ion, the following results were obtained. Initial flux of Cl-, organic anion and Na+ decreased with the increasing thickness of membrane, and as the concentration of the fixed carrier increases, the initial flux of Cl- and organic anion increase but the initial flux of Na+ decreased. The flux equation of the organic anion, CCl3COO- was obtained from saturation kinetics as follows;$V_{o}=\frac{(8.67{\times}10^{-5}){\cdot}[NaCl]}{9.63{\times}10^{-2}+[NaCl]} mol/cm^2h$

  • PDF

IEEE 802.11e기반 Mobile IPv6망에서 DiffServ를 이용한 신호처리 성능에 관한 연구 (The Study of Signal Processing Performance using DiffServ in Mobile IPv6 Network Based on IEEE 802.11e)

  • 손성찬;조경철;조병학
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2005년도 하계학술대회
    • /
    • pp.338-341
    • /
    • 2005
  • Recently there are increasing needs for Internet and various kinds of contents. These traffics for various contents need more amount of data to provide high-quality information and require various QoS depending on the characteristics of contents. However, current Internet service supports BE (Best Effort) service only, therefore IntServ (Integrated Service) scheme and DiffSserv (Differentiated Service) scheme are represented to support QoS in IP layer. This paper describes new scheme that provides QoS taking into account the traffic characteristics over Mobile IPv6 network based on IEEE 802.11e by decreasing signal process time using traffic class of DiffServ and evaluates the performance through computer simulation.

  • PDF