• 제목/요약/키워드: outside insulation

검색결과 133건 처리시간 0.024초

고기밀 고단열 주택의 기밀성능에 관한 실험적 연구 (Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction)

  • 신우철;윤종호;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

실리카겔을 활용한 흡착 경화체의 열전도율 특성 (Thermal Conductivity Properties of Adsorption Matrix According to Silica Gel)

  • 권오한;임현웅;이동훈;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2017
  • In recent years, it has been urgently required to develop and study a product that adsorbs and reduces lardon gas due to the risk of lardon gas in Korea. Therefore, this study develops a board for adsorbing lardon gas into the inside and outside of the room. The thermal conductivity was measured in order to carry out an adiabatic test for satisfying the following conditions. Experimental level and factors were substituted with silica gel. In addition, silica gel was used by dry mixing and prewetting, and 10, 20, and 30% of cement was substituted for each. As a result of the test, the thermal conductivity decreased to 0.45 W/mK with increasing the amount of replacement, and reached a similar level when compared with diatomite.

  • PDF

22.9kV 폐쇄 배전반내의 사고모델을 통한 실험적 검증 (Experimental Verification According to an Accident Model in a Metal-Clad Switchgear at 22.9kV)

  • 송길목;한운기;최충석
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.110-114
    • /
    • 2006
  • This paper describes the accident analysis by modelling the current transformer mounting in a metal-clad switchgear at 22.9kV. In analyzing the accident, the reconstruction at the current transformer mounting(VCB connecting guide) has to be taken into account. The accident was modelled as a 3-phase ground fault occurring between the end plate of 22.9kV lines and the safety shutter at the current transformer mounting of the VCB inside the metal clad switchgear. Since the outside maintenance of the metal clad switchgear is restricted by the enclosed compartments, Its circumference has to be kept clean. Through the reconstruction results, it was confirmed that the fault of the enclosed switchboard could be reduced when the shutter made of Fe material was chanted into an insulation.

프랙탈 차원을 이용한 SD절연의 새로운 평가 (The New Estimation of Surface Discharge Insulation Using Fractal Dimension)

  • 임장섭;한재홍;김덕근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.55-58
    • /
    • 2000
  • Fractal mathematics is being highlighted as a research method for classification of image. But the application of Fractal dimension(FD) has been required the complicated calculation method because of its complex repetition progressing. In this paper, it has been developed the new approach method to express the Fractal Dimension(FD) for aging level calculation and estimation system of outside insulator using special image processing algorithm. As a result after FD testing, the recognized aging estimation of FD has a very characteristics compared to the conventional visual inspection.

  • PDF

입자충전형 이중벽 온실에 관한 연구 (A Study on the Double-Wall Greenhouse Filled with Styrene Pellets)

  • 이석건;이종원;이현우
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.59-67
    • /
    • 1995
  • 자동단열온실시스템을 개발할 목적으로 실험용 온실의 천정과 벽체를 이중벽으로 제작하여 이중벽 내부에 단열입자를 자동으로 충전 회수할 수 있도록 시스템을 구성하여, 입자의 송풍성능, 투광성, 입자의 마모실험, 온실의 단열성능 및 차광효과를 분석한 결과를 요약하면 다음과 같다. 1. 약 2㎥의 입자를 충전 회수하는데 약 1시간 15분이 소요되었으나, 온실의 규모에 적합한 송풍기의 용량, 배기구의 면적, 충전관 및 회수관의 조절로 소요시간을 감소시킬 수 있을 것으로 판단되었다. 2. 단열입자의 회수 직후에 이중벽온실의 투광성을 객관성 있게 평가할 수 있는 10시에서 15시까지의 평균 투광율은 67%로 나타났다. 3. 입자의 충전 및 회수를 직송방식으로 하였을 때, 입자마모율이 연속 5개월 사용시 20%로 나타나, 입자의 충전 및 회수를 간접방식으로 수행하는 것이 타당한 것으로 분석되었다. 4. 겨울철 야간에 단열입자를 회수한 이중벽 온실의 내부온도는 외기온보다 평균 3.4$^{\circ}C$ 높았으나, 입자를 충전한 단열온실의 내부온도는 단열면적비가 73%일때 외기온보다 평균 6.6$^{\circ}C$ 높았고, 단열면적비가 100%일때 외기온보다 평균 13.5$^{\circ}C$ 높게 나타나 단열온실의 야간단열성능이 우수함을 알 수 있었다. 5. 일사가 양호하고 외기온이 높은 주간에 입자를 충전한 단열온실(단열면적비 100%)의 차광성능을 분석한 결과, 외기온의 평균이 36.9$^{\circ}C$일 때 온실내부온도의 평균은 3$0^{\circ}C$로 외기온보다 평균 7$^{\circ}C$ 낮게 나타나 차광효과가 크다는 사실을 알 수 있었다.

  • PDF

단열패널 종류별 이격거리에 따른 화재감식 평가 (Evaluation of Fire Investigation as the Separation Distances for Several Types of Insulation Panels)

  • 김정훈;김다슬
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.403-412
    • /
    • 2021
  • 단열패널(표면재, 심재, 마감재로 구성되어 있으며 경량성, 저가성 및 시공성 등의 장점)의 화재난연성과 적용건축물 강화에도 불구하고, 화재발생 건수와 피해 영향은 지속적으로 증가하고 있다. 본 연구에서는 단열패널 종류별이격거리에 따른 열영향(온도변화, 점화가능성, 내·외부 연소흔, 심재의 형상 변화)을 평가하고자 국내에서 사용빈도가 높은 EPS 패널, 글라스울 패널, 석고보드 패널의 3종을 선택하였다. 패널에는 지면으로부터 수직(30 cm, 90 cm, 150 cm)으로 온도센서를 설치하였고, 적층한 각목을 화원으로 패널로부터 각각 0 cm, 25 cm, 50 cm 이격거리를 변화시키면서 점화시켰다. 실험 결과, 최고온도는 EPS 패널에서 349 ℃를 나타내었고, 패널의 내·외부 형상변화는 이격거리 25 cm를 임계점으로 하부에서 중부까지 높이로 국한되었다. 또한 연소흔은 평균 500 s 이후에서 나타났고, 화재강도가 큰 EPS 패널에서는 광폭의 U자형 패턴, 글라스울과 석고보드 패널에서는 중폭 또는 협폭의 V자형 패널을 형성하였다. 도출된 정보를 통해 단열 패널로 구성된 건축물로부터 화재위험성 평가와 화재감식의 검증에 필요한 유용한 정보를 제공하고자 한다.

유중가스농도를 이용한 유입식 변압기 고장진단 기법의 신뢰성에 관한 연구 (A Study on the Reliability of Failure Diagnosis Methods of Oil Filled Transformer using Actual Dissolved Gas Concentration)

  • 박진엽;진수환;박인규
    • 전기학회논문지P
    • /
    • 제60권3호
    • /
    • pp.114-119
    • /
    • 2011
  • Large Power transformer is a complex and critical component of power plant and consists of cellulosic paper, insulation oil, core, coil etc. Insulation materials of transformer and related equipment break down to liberate dissolved gas due to corona, partial discharge, pyrolysis or thermal decomposition. The dissolved gas kinds can be related to the type of electrical faults, and the rate of gas generation can indicate the severity of the fault. The identities of gases being generated are using very useful to decide the condition of transformation status. Therefore dissolved gas analysis is one of the best condition monitoring methods for power transformer. Also, on-line multi-gas analyzer has been developed and installed to monitor the condition of critical transformers. Rogers method, IEC method, key gas method and Duval Triangle method are used to failure diagnosis typically, and those methods are using the ratio or kinds of dissolved gas to evaluate the condition of transformer. This paper analyzes the reliability of transformer diagnostic methods considering actual dissolved gas concentration. Fault diagnosis is performed based on the dissolved gas of five transformers which experienced various fault respectively in the field, and the diagnosis result is compared with the actual off-line fault analysis. In this comparison result, Diagnostic methods using dissolved gas ratio like Rogers method, IEC method are sometimes fall outside the ratio code and no diagnosis but Duval triangle method and Key gas method is correct comparatively.

투명단열 축열벽 시스템의 열성능 평가 실험 연구 (Thermal Performance Evaluation Monitoring Study of Transparent Insulation Wall System)

  • 김병수;윤종호;윤용진;백남춘;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제23권1호
    • /
    • pp.1-8
    • /
    • 2003
  • Various efforts to combine new high-tech materials with solar system have been progressed nowadays in order to improve the performance of the existing passive solar system. TIM(Transparent Insulation Material) replacing the conventional outer building envelope glazing as well as the wall is good example for this trend. TI integrated wall is a thermal mass wall with a special shaped TIM instead of using typical envelope materials The tested TIM type is a small(diameter 4mm and thickness 50mm) capillary tube of Okalux model and cement brick(density 1500kg/m3). The purpose of this study was to analyze the thermal performance through the actual measurements performed in a test cell. This study was carried out to justify the following issues. 1) the impact of Tl-wall over the temperature variations 2) the impact of mass wall surface absorptance over the transient thermal behavior and 3) the impact of thermal mass wall thickness over the temperature variations. Finally, as results indicated that the peak time of room temperature was shifted about one hour early when absorptance of thermal mass wall changed from 60% to 95% for the 190mm thickness thermal mass wall test case. the temperature difference of both surfaces of thermal mass wall surface showed about $23^{\circ}C$ during a day of March for the 380mm thickness thermal mass wall case. However, the thermal mass wall was over-heated by outside temperature and solar radiation in a day of May the temperature difference of both surfaces of thermal mass wall surface was indicated $10^{\circ}C$ and inside temperature was observed more than average 22C.

발전소용 이중보온용 강관의 홈부식(Grooving Corrosion)에 의한 파손 분석 (The Failure Analysis of Double Pipe for Insulation Used Power Plant by Grooving Corrosion)

  • 함종오;박기덕;박성진;선일식
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권3호
    • /
    • pp.197-206
    • /
    • 2015
  • Failure analysis of pre-insulated pipe (SPPS 380, 400A) transporting high temperature water ($95{\sim}110^{\circ}C$) for a plant was carried out. The damaged area (${\Phi}5mm$) of pre-insulated pipe was found only on welds. The chemical composition of damaged pipe meets specification of carbon steel pipes for pressure service (KS D 3562). As results of microstructure analysis, crack propagated from outer to inside after pitting corrosion occurred on the outside surface. The non-metallic inclusion existed on the end of crack. And the non-metallic inclusion continuously and linearly formed along with the bond line of welds. Based on SEM-EDS analysis, the nonmetallic inclusions have higher Manganese (Mn) and Oxygen (O) content but sulfur (S) was not detected. As results of water quality analysis, hydrogen ion concentration and minerals like Fe, Mg, Si were in low level. But the content of dissolved oxygen (11.2 ppm) was slightly higher than that of standard. It seems that the cause of damaged pipe is grooving corrosion due to MnO inclusion formed on bond line and corrosion took place nearby welds.

제로카본 그린홈의 여름철 운영조건에 따른 실내 열환경 평가 (An Evaluation of Indoor Thermal Environment for Zero-Carbon Green Home according to the Operation Conditions in Summer)

  • 유정연;조동우;김기한
    • 한국태양에너지학회 논문집
    • /
    • 제40권2호
    • /
    • pp.25-36
    • /
    • 2020
  • The Korean government has a plan to mandate zero-energy buildings in 2020 for public and 2025 for private buildings. In order to design a zero-energy building, insulation and airtightness, which are the most basic elements of passive house technology, are required, and the government has been accomplished this through step-by-step strengthening of related standards. In passive house with high thermal insulation and airtightness performance, the heat introduced into the building through solar radiation can be stored for a long time to keep the inside warm during winter. On the other hand, during summer, heat introduced into the building cannot be easily released to outside, so it is necessary to actively block solar radiation and high temperature outdoor air to prevent an increase of indoor temperature. Therefore, this study aims to derive an appropriate operation condition of passive house to maintain the indoor temperature at an suitable level according to the ventilation methods and solar shading conditions. As a result, under the conditions that the outdoor temperature was 28℃ or less, the ventilation using a heat recovery ventilation system at daytime and natural ventilation at nighttime were selected for the most appropriate operation method. In addition, in the case of solar shading, it was found that blocking solar radiation at daytime using the blind and open the blind at nighttime to ensure natural ventilation were selected for the most appropriate solar shading condition.