• Title/Summary/Keyword: outside experiment

Search Result 350, Processing Time 0.023 seconds

A Study on the Channel Noise on VDT Workstation (VDT 작업환경에서 경로노이즈에 관한 연구)

  • Kwon, Kyu-Sik;Choi, Chul
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.25 no.1
    • /
    • pp.71-77
    • /
    • 2002
  • This study deals with noise occurring in the process of human information transmission. Human process many kinds of information by receiving them from the outside or using their own thought and express the processed information to the outside by acting. In this process, Channel Noise ($C_N$) is defined as the characteristics of noise generating the incomplete result for the external stimulus. To evaluate $C_N$, keyboard-typing experiment has been performed to the 87 subjects. In this experiment, the subject consists of college students who have abundant experience in computer usage. In the experiment, there were some cases that typing order was unconsciously reversed. In this study, we deal with only these cases since these cases can be used as important data to study humans information transmission system.

Design of Current Probe Using Faraday Effect of Optical Fiber (광 파이버의 패러데이 효과를 이용한 전류측정용 프로브 설계)

  • Kang, Hang-Sik;Kim, Chul-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1278-1280
    • /
    • 1995
  • A probe type fiber-optic sensing techique for electric current measurement is applied in this paper. The technique is based on the Faraday effect which meaning is that polarization state of light is rotated by magnetic field. In experiment, test wire is located at inside and outside of the probe to be measured. The experimental results prove not only linear property, but also polarization rotation property according to the distance from outside of probe.

  • PDF

Ecological Studies on Togyo Reservoir in Chulwon, Korea. 7. The Colonization of Epilithic Algae on Artificial Substrata (Tiles) at Mesocosm

  • Lee, Kyung;Yoon, Sook-Kyung;Ki, Jang-Seu;Han, Myung-Soo
    • ALGAE
    • /
    • v.19 no.2
    • /
    • pp.107-114
    • /
    • 2004
  • Patterns of epilithic algal colonization on artificial substrata (unglazed ceramic tiles) were investigated from 23rd April to 3rd July 1999 at weekly intervals over a 10 weeks period outside and inside the mesocosm in Togyo reservoir within the Civilian Passage Restriction Line near Demilitarized Zone (DMZ) in Korea. The highest standing crops of epilithic algae was 1,798$\cdot$10³ cells$\cdot$$cm^{-2}$ outside the mesocosm on 26th June and also inside the mesocosm those was 2,391$\cdot$10³ cells$\cdot$$cm^{-2}$ on 26th June, 9 weeks after the experiment began. The dominants outside the mesocosm were Achnanthes minutissima, Navicula bicephala, Oscillatoria angusta, Synedra delicastissima, S. tenuissima, S. ulna v. danica and Tabellaria flocculosa, and those inside the mesocosm were Achnanthes minitissima, Coenochloris polycocca, Fragilaria crotonenesis, Peridinium cinctum, Synedra delicatissima, Tabellaria flocculosa and Ulothrix subtilissima. Diatoms were most abundant and Achnanthes minutissima was the most important species colonizing on the tiles. Chlorophyll-a content was highest value of 5.4 mg$\cdot$$m^{-2}$ on 19th June after 8 weeks growth outside the mesocosm and was 24.4 mg$\cdot$$m^{-2}$ on 26th June, 9 weeks after the experiment began on tiles inside the mesocosm. It was also shown that unglazed ceramic tiles were a more suitable substratum for colonization than the glass slides. Consequently the substratum selection plays an important role in the colonization by the epilithic algal community.

Effect of Elementary Students' Understandings about Principle of Land and Sea Breeze Using Incense Smoke on the outside of Convection Current Box as a Scaffold in Convection Current Box Experiment (대류상자 밖의 향 연기 이동을 비계로 활용한 대류상자 실험이 초등학생들의 해륙풍의 원리 이해에 미치는 효과)

  • Kang, Wonmi;Shin, Aekyung;Hyun, Donggeul;Chae, Donghyun
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.8 no.3
    • /
    • pp.387-398
    • /
    • 2015
  • The purposes of this study were to analyze the effect of a scaffold to help in understanding the principle of land and sea breeze through the convection current box experiment and to analyze the students' inference abilities and analogy abilities. For this purpose, the 60 elementary students who had not learned the principle of land and sea breeze were surveyed and analyzed. When using the scaffold to compare the movement of the incense smoke in the convection current box with that of the incense smoke on the outside of the convection current box, the rate of the students who correctly understood the principle of the land and sea breeze between the sea and the land was very low. The result shows that the scaffold used in this study do not help sufficiently in understanding the principle of the land and sea breeze through analogy and it is necessary to introduce a new scaffold for the elementary students to understand it.

An Analysis on Thermal Insulation Effect of Farm Structures Coated with Surface Treatment (표면코팅 구조재의 달열효과 분석)

  • Suh, Won-Myung;Yoon, Yong-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.4
    • /
    • pp.39-46
    • /
    • 2004
  • This experiment was carried out to study on the effect of surface coating on thermal insulation of farm structures to improve thermal resistance and reflective effect of solar radiation. Nine different types of experimental specimen were compared in the temperature variations of inside and outside; A, B, C, D. E and F types are box container and G, H and I types are drum container. The size of these containers is $1,500{\times}2,000{\times}2,500$ mm and ${\varphi}$ $280{\times}330$ mm, respectively. Specimen of 3-type box(A, B, C) is galvanized steel sheet of thickness 0.45 mm. D, E and F types are sandwich panel of the thickness 50 mm inserted with urethane, glass wool and polystyrene form, respectively. G, H and I types are paint pot using in general. The surface of A. D, E, F and I types didn't any treatment, B, C and G types were treated with thermal insulation coating on the outside surface(B, G) or the inside and outside surface(C). And H type was treated with water paint coating on the only outside surface. In general, the experimental results showed the following tendencies; In case of A, B and C types. it was found that the thermal insulation effect of types coated with thermal insulation coating was improved remarkably than that of no treatment. And the thermal insulation effect between steel sheet and sandwich panel type was nearly similar There was not a significant difference of thermal insulation effect between thermal insulation coating and water paint coating. In time of drum container filled with rough rice, The difference of heat transfer tendency and temperature variation among surface treatments was nearly similar that of box types of galvanized steel sheet. And there was time lag about 6 hours between the temperature of middle part of rice and that of inside or outside surface.

Experimental Study on the Cooling Performance of Vertical Closed Loop Water to Water Ground Source Heat Pump System (물 대 물 방식 수직 밀폐루프 지열원 히트펌프 시스템의 냉방성능에 대한 실험적 연구)

  • Hong, Boo-Pyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.58-63
    • /
    • 2014
  • A vertical closed loop ground source heat pump (GSHP) is used to produce heat from the low-grade energy source such as the outside air and ground source. It is known that a heat pump system type has better efficiency comparing to the electric heating system. This study only demonstrates that the vertical closed loop GSHP system is a feasible choice for space cooling of air conditioning. The coefficient of performance (COP) is the ratio of heat output to work supplied to the system in the form of electricity. For the vertical closed loop GSHP system in a cooling mode, the COP is the most commonly used way for judging the efficiency. For the purpose of this experiment, vertical closed loop GSHP system was installed in the laboratory and the experiment was executed. As a result, an average COP of vertical-closed loop GSHP system was 3.62 when the outside average temperature was $33^{\circ}C$.

Characteristics of Heat Transmission Variation by Air Space Thickness and Injected Air Temperature in Air-Inflated Double Layers Film (공기막 이중필름의 공기막 두께와 주입공기 온도에 따른 관류전열량 변화 특성)

  • Kim, Hyung-Kweon;Jeon, Jong-Gil;Paek, Yee;Lee, Sang-Ho;Yun, Nam-Kyu;Yoo, Ju-Yeol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.121-125
    • /
    • 2013
  • This study was carried out to provide a valuable reference which could reduce heating loss of air-inflated double PO film. Therefore, this study was aimed to choose the best air space thickness and injected air temperature. The characteristics of heat transmission variation at experimental materials were measured and analysed in the laboratory. The experiment was conducted of two layers of PO film, each 0.15 mm tick, sandwiching 110, 175, 225 mm of inflated air with 1 m sides. Environmental control lab was constantly controlled with $-10^{\circ}C$ and experiment chamber was constantly changed with 0, 5, 10, $15^{\circ}C$. The analysis of heat transfer showed that heat transmission does not have a direct correlation with Air Space thickness and injected air temperature. But when inside and outside temperature difference of chamber was great, supply of outside air to Air Space had an advantage at reduction of heating load. It was required to examine accurate analysis at a real greenhouse.

Experiments on the Condensation Heat Transfer Enhancement of Horizontal Circular Tube with Threaded Outside Surface (외표면 형상이 원관의 응축열전달에 미치는 영향)

  • Lee, Jin Ho;Nam, Leem Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.3
    • /
    • pp.230-237
    • /
    • 1988
  • An experiment was carried out to study the condensation heat transfer enhancement of horizontal circular cylinders with varying outside surface configurations. The refrigerant used is Freon-22 and the test condensing temperature is 34.1C. Pin-finned tube shows about 2.5-3.5 times higher overall heat transfer coefficient compared to that of smooth surface tube, thus has larger encomic benifit for condenser design. The condensation heat transfer coefficient was shown to increase as the fin-pitch of the pin-finned tube decreases for film Reynolds number larger than 100.

  • PDF

Experimental Study on the Characteristics of the Inside and Outside Pressure Variation for KTX (KTX차량 객실내외의 압력변동특성에 관한 실험적 연구)

  • Nam Seong-Won;Hong Hyeon-Ju
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.281-286
    • /
    • 2003
  • Experimental study is conducted to clarify the inside and outside pressure variation of passenger cabin for KTX. These pressure variation may give rise to the ear-discomfort. Generally ear-discomfort has been considered as a problem related to high speed train. In this study, the pressure variation of interior, gangway and exterior of KTX passenger car is measured by using the atmospheric pressure sensors and portable data acquisition system. The tunnel from 4000m to 200m in length are chosen for the investigation of length effects. From the results of experiment, the pressure variation of interior per second is under the ear-discomfort limitation in all of tunnel. And, We found that there is a similar pattern of exterior pressure variation. These results generally agree with RTRI's experimental result for Shinkansen.

  • PDF

Study on the Result Changes with the Size of the Variance in Taguchi Method and Factor Experimental (다구찌 기법과 요인실험의 실험 데이터의 산포 크기에 따라 결과 변화 고찰)

  • Ree, Sangbok
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.1
    • /
    • pp.119-134
    • /
    • 2013
  • Purpose: The purpose of this paper is to show whether the results are changed with respect to the variance of the data, by analysis of data obtained from the Taguchi experimental techniques and general experiment. Because which cannot be prove by mathematical Formula, through experimental examples will show. Methods: Taguchi experiments were carried out with paper Helicopter experiment. Experimental Data are obtained by special designed Drop Test Equipment. While Experimental value arbitrarily changed, we looked at how Significant control Factor of Taguchi Methods and Factor experiments are changed. This process cannot be expressed as a Mathematical formula, but showed as a numerical example. Results: Saw significant changes in the factors when data is outside a certain range of the experimental data. By Test of Equivalence Variance, Experiment data is verified reliability. To find the Control Factor, Taguchi Method is better than the general experiment. Conclusion: We know that a Significant Factor is changed with the range of Variance of Experiment Data. The value of this paper is verified change process with Numerical Data obtained Experiment.