• 제목/요약/키워드: output effect

검색결과 2,468건 처리시간 0.031초

Medical Tourism Industry in Kangwon Province and Its Economic Impacts on the Region

  • Zhu, Yan Hua;Kang, Joo Hoon;Jung, Yong-Sik
    • 한국산업정보학회논문지
    • /
    • 제19권3호
    • /
    • pp.115-125
    • /
    • 2014
  • This paper has two purposes. The first is to suggest the new and simple method to derive a regional input-output model from the national input-output table published by the Bank of Korea. The interregional input-output table has not been devised in spite of its potential use while the national table has been made every five years with the revised version during each five years. Second, this paper aims to derive Kangwon interregional input-output model from the national model using the regional supply proportion of industry and to analyze the effect of medical tourism industry on the regional economy of Kangwon Province. The paper measures, in particular, the effect of medical tourism industry on the financial self-sufficiency of Kangwon Province using the estimated output elasticity of tax revenue with the autoregressive distributed lag scheme ADL(1,1) in which the dependent variable and the single explanatory variable are each lagged once.

흰쥐에서 대상회전 제거가 위액분비에 미치는 영향 (Effect of Cingulate Cortical Ablation upon Gastric Secretion in Rats)

  • 박형진;안병태;조양혁
    • The Korean Journal of Physiology
    • /
    • 제11권2호
    • /
    • pp.67-71
    • /
    • 1977
  • This study was undertaken to investigate the effect of cingulate cortical ablation upon gastric secretion and its components in rats. 23 male rats were divided into the cingulate(N=9) and the operated control(N= 14) groups. Cingulate cortex was ablated through a slit-shaped opening(1 mm in width, 5 mm in length) which was made symmetrically on both sides of, and parallel to, the sagittal suture by removing a bone flap from frontal bone on each side. In the operated control group, the surgical procedure was ended by the removal of the bone flap. Under light ether anesthesia, experimental animals were placed in a restraining jacket of fine mesh wire and gastric juice was collected for 5 hours via a canula which had been inserted through the anterior abdominal wall into the antral portion of the lumen of the stomach. Volume of the gastric juice was measured, and total acid output and free acid output were titrated with 0.04 N NaOH solution by using phenolphthalein and Topfer's reagent at indicator, and chloride ion output was estimated by means of chloridometer. Results obtained were that volume, total acid output, free acid output and chloride ion output of the gastric juice were higher significantly in the cingulate group than in the operated control group. It is inferred from the above results that the cingulate cortex exerts a fascilitatory influence upon gastric secretion and acid output in rats.

  • PDF

그림자 영향을 고려한 PV MIC 시스템의 새로운 MPPT 제어 (A Novel MPPT Control of PV MIC System Considering the Shaded Effect)

  • 최정식;정동화
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.21-33
    • /
    • 2012
  • This paper presents the new maximum power point tracking(MPPT) control of the photovoltaic(PV) module integrated converter(MIC) system considering the shadow influence. The output characteristics of the solar cell is a nonlinear and affected by a temperature, the solar radiation and influence of a shadow. Particularly, MIC system is very sensitive to the shadow influence because the capacity is very small. In order to increase an output and efficiency of the solar power generation, the maximum power point(MPP) obeying control are necessary. Conventional perturbation and observation(PO) and Incremental conductance(IC) are the method finding MPP by the continued self-excitation vibration. The MPPT control is unable to be performed by rapid output change affected by the shadow. To solve this problem, the new control algorithm of the multi-level in which the step value changes by output change is presented. In case there are the solar radiation, a temperature and shadow influence, the presented algorithm treats and compares the conventional control algorithm and output error. In addition, the validity of the algorithm is proved. through the output error response characteristics.

The Effect of Predictive Reaeration Estimation Equation on Stream Water Quality Modeling

  • Kim, Hyung-Joong
    • 한국농공학회지
    • /
    • 제39권2호
    • /
    • pp.97-103
    • /
    • 1997
  • DO concentration in the aquatic system is important for the water quality management perspective. Water quality model uses available reaeration coefficient (K2) estimation equations in calculating DO, however, they might include inevitable uncertainty that the model output can be less reliable. In this study, the calibrated QUAL2E model for the Passaic River in New Jersey, U.S., was used to examine the effect of K2 estimation equation on the output DO concentration of the river. The model was run with six commonly used equations separately with all the other conditions remained same. The result showed that the output DO concentration profiles varied widely with different equations, and maximum difference was 4.96 mg/L for the same location which is unacceptably large. It implies that the development of reliable equation is required for proper water quality management. The unreliable model output can lead to a wrong decision in water quality management such as unnecessarily high or too low treatment of wastewater, which will cause serious effect on the community economically and socially in either case. Generating more reliable model output with slight investment to develop a site specific K$_2$ equation can improve the decision making process significantly and is highly recommended.

태양광 어레이 설치 위치 및 각도변경 전후의 태양광 발전 시스템의 출력 변화에 관한 연구 (A Study on PV System Output Changes by PV Array Installation Position and Mount Angle Change)

  • 윤정필;차인수;최정식;김동묵;박종복;하민호;김원배
    • Current Photovoltaic Research
    • /
    • 제2권4호
    • /
    • pp.189-194
    • /
    • 2014
  • In this paper, We have simulated the output variation of the PV arrays installation with position & angle change. The existing 3 solar array system are $43^{\circ}$ southeast and each of the mounting angle is $17^{\circ}$. The PV output power is 240 kW. The composite studied systems in this paper arrays altered 2 PV array among 3 PV array system- the output 144kW. We simulated this system using Solar Pro ver.4.1. The simulation conditions are southwest $43^{\circ}/array$, mount angle $27^{\circ}/array$. Because the southeast have shadow effect-higher mountain The purpose of southwest $43^{\circ}$ is reduce the shadow effect. The simulation results of the suggestion design algorithm compared to 1,590 kWh/year output is increased with the southeast.

인버터의 비선형 특성이 유도전동기의 자속 추정에 미치는 영향에 대한 연구 (A study on the effect of inverter nonlinear characteristic on the flux estimation of an induction motor)

  • 김상훈;김태석
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.167-174
    • /
    • 2008
  • In this paper, the analysis on type effect of inverter output voltage distortion on the control of an induction motor is discussed. The inverter output voltage is distorted differently from the reference voltage owing to the inverter nonlinear characteristic. The inverter nonlinear characteristic results from the voltage drop, the inherent characteristic of the power semiconductor, and the dead time for preventing the short circuit of the inverter leg. This characteristic distorts the inverter output voltage and then, causes the motor flux estimation error. Although this characteristics do not significantly effect in the general-purpose induction motor control, but significantly effect on the low-speed operation of high performance motor control such as the sensorless vector control.

  • PDF

PVDF 필름의 압전정효과에 관한 연구 (Study on the Piezoelectric Direct Effect of PVDF Film)

  • 이용국;한득영
    • 한국전기전자재료학회논문지
    • /
    • 제13권9호
    • /
    • pp.786-790
    • /
    • 2000
  • This paper is concerned on the theoretical and experimental approaches of direct piezoelectric effect in the PVDF film. When a cantilever structure of PVDF film is bended by the external force, electric charges are concentrated on the electrode surface of the film due to the direct piezoelectric effect, and output voltage is induced from the terminals of the film. In this paper, a symbolic equation between the external force and the output voltage was introduced. Moreover, the theoretical output voltages were compared with the experimental results by falling balls, which were agreed well each other. This results can be useful in a warning system of abnormal pulse rate and breathing, and in detecting impact force and/or mechanical energy using bending of PVDF film.

  • PDF

핀테크 산업의 경제적 파급효과 분석 (An Analysis of Economic Effects of The Fintech Industry)

  • 정영근;박호영;박추환
    • 한국IT서비스학회지
    • /
    • 제17권1호
    • /
    • pp.47-58
    • /
    • 2018
  • In this study, we define Fintech services as review previous literatures and identify the traditional Fintech service market for analysing the economic effects of the Fintech Industry by using the 2014 Input-Output Table. We can identify the current market of Fintech industry which consists of VAN, PG, financial SW, mobile banking and Fintech R&D and we conduct Input-Output analysis by using non-competitive import model. The Input-Output analysis results show that production inducement effect and front/rear chain effect of the Fintech Industry are below average of other industries. This is because the Fintech technology and industry were emerging in Korea at that time (2014), and thus the ripple effects are not significant. Especially, due to the existing white risk financial regulation, new business opportunities have not been open to adapt new ICT-financial technologies. Therefore, when the business ecosystem is build through deregulation and platforms of the financial sector, it is expected that the Fintech Industry will have a high ripple effect. In this study, we identify the current market of Fintech industry from ICT indusries and conduct Input-Output analysis. The economic effects of the Fintech industry are not remarkable, but it is significant to identify the emerging market and present the basic analysis of issued research field.

A New Phase-Locked Loop System with the Controllable Output Phase and Lock-up Time

  • Vibunjarone, Vichupong;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1836-1840
    • /
    • 2003
  • This paper, we propose a new phase-locked loop (PLL) system with the controllable output phase, independent from the output frequency, and lock-up time. This PLL system has a dual control loop is described, the inner loop greatly improved VCO characteristic such as faster speed response as well as higher operation bandwidth, to minimize the effect of the VCO noise and the power supply variation and also get better linearity of VCO output. The main loop is the heart of this PLL which greatly improved the output frequency instability due to the external high frequency noise coupling to the input reference frequency also the main loop can control the output phase, independent from the output frequency, and reduce the lock-up time of the step frequency response. The experimental results confirm the validity of the proposed strategy.

  • PDF

태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템 (Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation)

  • 김홍성;최규하;유권종
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF