• Title/Summary/Keyword: outdoor air quality

Search Result 207, Processing Time 0.026 seconds

A Study on the Operational Strategy for Hybrid Ventilation System in Apartment unit focused on Indoor Air Quality (실내공기질을 고려한 공동주택의 하이브리드 환기 시스템의 운영에 관한 연구)

  • Lee, Yong-Jun;Leigh, Seung-Bok;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.203-210
    • /
    • 2004
  • This dissertation identifies and investigates the possible control modes of hybrid ventilation system in applying to general apartments. It evaluates range of hybrid ventilation control modes in terms of indoor air quality, thermal comfort, and energy consumption in a living room and a kitchen of the $1000m^2$ apartment. The TRNSYS simulation program was used for evaluating the following four ventilation types : A ventilation mode relying on only infiltration for supplying air, A natural ventilation mode considering with weather condition, A hybrid ventilation (natural + mechanical ventilation) mode allowing minimum ventilation with no heat exchange, and a hybrid ventilation mode with heat exchange. This study shows the following results. As temperature being controlled by heating cooling equipments, there is without significant difference in thermal performance among ventilation types. Regarding Indoor Air quality, Indoor air contamination level of the hybrid ventilation case consistently keep the lower levels. The hybrid ventilation modes consume more energy by a 49% as compared to the A ventilation mode relying on only infiltration for supplying air. It is caused by the continuous ventilation for keeping good indoor air quality; the increase of energy consumption can be attributable to the increase of the heating energy. Therefore, the heat exchange between indoor and outdoor air is required during heating season in severe weather conditions. During the cooling seasons, Introducing natural ventilation can achieve energy saving by 40 ~ 45%. Thus, it can be an effective strategies for energy saving. Based on these results, a hybrid ventilation system can be suggested as an effective ventilation strategy for archiving high level of indoor air quality, thermal comfort, and energy consumption.

Development of Real-time Monitoring Platform for Indoor Air Quality Using Air Quality Sensors (AQ센서를 활용한 실내 대기 질 실시간 모니터링 플랫폼 개발)

  • Oh, Sang-Heon;Kim, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.206-209
    • /
    • 2018
  • According to data released by the WHO(World Health Organization), the death toll from indoor air pollution in 2016 was about 3.8 million. While many people are aware of outdoor air pollution, indoor air pollution is getting less attention. Recently, however, indoor air pollution has also become a big problem, raising many issues. Frequent indoor activities such as cooking and heating produce various pollutants, which can cause children and elderly with weak immune systems to be exposed to pollutants, which can cause serious health problems such as poor lung function and respiratory diseases. Therefore, in this paper, the IoT(Internet of Things) platform that measures and monitors indoor air quality using AQ(Air Quality) sensors is developed so that data can be monitored in real time through applications and reactive web.

  • PDF

Performance Evaluation of Heat Exchangers due to Air-side Particulate Fouling in the Air Conditioners (공기측 파울링에 의한 에어컨 열교환기의 성능분석 연구)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.447-453
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the cooling performance and pressure drop on the air-side particulate fouling of heat exchangers for air conditioners. Air conditioners being used in the field such as inn, restaurant, and office are collected in chronological used order. Test results show 15% decrease of the cooling capacity and 44% increase of the pressure drop for the 7 years air conditioners used in the seaside inn.

Estimation of Source Strength and Deposition Constant of Nitrogen Dioxide Using Compartment Model (구획모델을 이용한 주택에서 이산화질소의 발생강도 및 감소상수 동시 추정)

  • Yang Won-Ho;Son Bu-Soon;Sohn Jong-Ryeul
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.260-265
    • /
    • 2005
  • Indoor air quality might be affected by source strength of indoor pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate the source strength and deposition constant by application of multiple measurements. For the total duration of 60 days, indoor and outdoor $NO_2$ concentrations every 3 days were measured in 30 houses in Seoul, Asan and Daegu. Using a compartment model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the source strength and deposition constant were estimated. Natural ventilation was $1.80{\pm}0.42\;ACH,\;1.11{\pm}0.50\;ACH,\;0.92{\pm}0.26\;ACH$ in Seoul, Asan and Daegu, respectively. Calculated deposition constant(K) and source strength of $NO_2,$ in this study were $0.98{\pm}0.28\;hr^{1}\;and\;16.28{\pm}7.47\;ppb/h,$ respectively.

Estimation of NO$_2$ Source Generation and Ventilation rate in Residence by Multiple Measurements

  • Won Ho, Yang;Gi Yeong, Lee
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.05a
    • /
    • pp.155-160
    • /
    • 2003
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor $NO_2$ concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential $NO_2$ deposition constant of 1.05 $hr^{-1}$, and 1.36 ACH in Seoul, with the measured residential $NO_2$ deposition constant of 0.94 $hr^{-1}$. Source strengths of $NO_2$ were 15.8 $\pm$ 18.2 ${\mu}g$/$m^3$.hr and 44.7 $\pm$ 38.1${\mu}g$/$m^3$.hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

Estimation of Nitrogen Dioxide Source Generation and Ventilation Rate in Residence Using Multiple Measurements in Korea

  • Chung, Moon-Ho;Yang, Won-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.12a
    • /
    • pp.45-50
    • /
    • 2004
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Alt hough technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor NO2 concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and NO2 source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential NO2 deposition constant of 1.05 hr-1, and 1.36 ACH in Seoul, with the measured residential NO2 deposition constant of 0.94 hr-1. Source strengths of N02 were 15.8 ${\pm}$ 18.2 ${\mu}$g/m3${\cdot}$hr and 44.7 ${\pm}$ 38.1 ${\mu}$g/m3${\cdot}$hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

Characteristics of the Air-side Particulate Fouling Materials in Finned-Tube Heat Exchangers of Air Conditioners (공기조화기용 열교환기의 공기측 파울링 입자 분석 연구)

  • 안영철;신희수;황유진;이창건;이재근;이현욱;안승표;윤덕현;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.611-617
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the characteristics of the air-side particulate fouling materials in finned-tube heat exchangers of air conditioners. Air conditioners being used in the field such as inns, restaurants, and offices are collected in chronological order in use. Typical fouling materials on the heat exchangers include fibers and dusts ranged from 6.6 to 20.9 ${\mu}{\textrm}{m}$ in mass median diameter.

Comparison of Correlation between Total Airborne Bacteria and Particulate Matter in University Spaces (일부 학교 내 총부유세균 및 미세먼지의 상관성 비교)

  • Hyekyung Seo;Harim An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.2
    • /
    • pp.115-124
    • /
    • 2024
  • Objectives: The aim of this study is to assess indoor air quality within and around buildings and evaluate the health risks associated with exposure to indoor air pollution. The study compares IAQ standards established by the World Health Organization with those set by South Korea's Ministry of Environment and Ministry of Education. Methods: The study utilized an Anderson Sampler and DustTrakTM II to collect samples of total airborne bacteria and PM in indoor and outdoor environments. Collected samples were analyzed using biological and biochemical methods. Statistical analysis was conducted using SPSS to examine the correlation between airborne bacteria and PM. Results: The study revealed that the concentration of total airborne bacteria in indoor air generally remained below the Ministry of Environment's standard of 800 CFU/m3, although it surpassed this threshold in certain instances. PM concentrations did not exceed the standards. Indoor fine dust concentration was higher when there were people (P<0.05). There was no difference in total floating bacterial concentrations between indoor and outdoor environments (P=0.184). Finally, there was a correlation between fine dust and airborne bacteria concentrations. Conclusion: The study evaluated the concentrations of total airborne bacteria and PM in indoor air, emphasizing the importance of managing IAQ. Further research in various environments is essential to ensure a healthy indoor environment. The findings underscore the need for ongoing research and management to enhance IAQ and create safer and healthier living environments.

Changes in Air Quality through the Application of Three Types of Green-Wall Model within Classrooms (교사 내 플랜트 모델 유형별 적용에 따른 공기질 변화)

  • Ho-Hyeong Yang;Hyung-Joo Kim;Sung-Won Bang;Heun-Woo Cho;Hyeong-Seok Lee;Seung-Won Han;Kwang-Jin Kim;Ho-Hyun Kim
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.6
    • /
    • pp.295-304
    • /
    • 2023
  • Background: Adolescents are relatively more sensitive than adults to exposure to indoor pollutants. The indoor air quality in classrooms where students spend time together must therefore be managed at a safe level because it can affect the health of students. Objectives: In this study, three types of green-wall models were applied to classrooms where students spend a long time in a limited space, and the resulting effects on reducing PM were evaluated. Methods: In the middle school classrooms which were selected as the experimental subjects, IoT-based indoor air quality monitoring equipment was installed for real-time monitoring. Three types of plant models (passive, active, and active+light) were installed in each classroom to evaluate the effects on improving indoor air quality. Results: The concentration of PM in the classroom is influenced by outdoor air quality, but repeated increases and decreases in concentration were observed due to the influence of students' activities. There was a PM reduction effect by applying the green-wall model. There was a difference in PM reduction efficiency depending on the type of green-wall model, and the reduction efficiency of the active model was higher than the passive model. Conclusions: The active green-wall model can be used as an efficient method of improving indoor air quality. Additionally, more research is needed to increase the efficiency of improving indoor air quality by setting conditions that can stimulate the growth of each type of plant.

A preliminary study of Standardization Plan on Underground Air filtration Facility (지하역사 공기여과장치 표준화방안 사전연구)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.919-929
    • /
    • 2009
  • 2008, Seoulmetro transports an average of 3,952,000 passengers every day with a 0.8% increase of the daily ridership compared to last year.(Korean Economics '09.01.21) Seoul subway systems ridden by a considerable number of Seoul citizens place their top priority on swiftness, safety and clean underground air quality so as to meet the customer satisfaction. One of the most important problems is to eliminate minute dust(PM10) among the pollutants such as the gas attributable to air pollution and floating particulate matter defined by the ordinance of the Ministry of Environment. Seoulmetro install and operate many kinds of air filtration facilities, however we've launched a research on "Standardization Plan on Underground Air Filtration Facility" for the installation and improvement of optimum standardized air filtration system. As a preliminary study, we're going to consider ventilation system and air filter to supply filtered metropolitan outdoor air aimed at ensuring clean underground environment.

  • PDF