• Title/Summary/Keyword: orthodontic bracket

Search Result 176, Processing Time 0.033 seconds

Corrosion Characteristics of TiN and ZrN Coated Orthodontic Brackets (TiN 및 ZrN 코팅된 교정용 브라켓의 부식특성)

  • Kim, W.G.;Kim, D.Y.;Choe, H.C.
    • Journal of the Korean institute of surface engineering
    • /
    • v.41 no.4
    • /
    • pp.163-168
    • /
    • 2008
  • The dental orthodontic bracket requires good mechanical properties, such as elastic strength and frictional resistance, combined with a high resistance to corrosion. The objective of this study was to investigate the effects of TiN and ZrN coating on corrosion resistance of orthodontic brackets using various electrochemical methods. Brackets manufactured by Ormco Co. were used, respectively, for experiment. Ion plating was carried out for coatings of bracket using Ti and Zr coating materials with nitrogen gas. Ion plated surface of each specimen was observed with field emission scanning electron microscopy(FE-SEM), energy dispersive Xray spectroscopy(EDS) and electrochemical tester. The corrosion potential of the TiN and ZrN coated bracket was comparatively high. The current density of TiN and ZrN coated bracket was smaller than that of non-coated bracket in 0.9% NaCl solution. Pit nucleated at angle of bracket slot.

Comparison of frictional forces between orthodontic brackets and archwires (교정용 브라켓과 호선 간의 마찰 저항력의 비교)

  • Suh, Chung-Whan;Jung, Hye-Seung;Cho, Jin-Hyoung;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.116-126
    • /
    • 2005
  • The object of this study was to evaluate how friction that occurs during the sliding movement of an orthodontic archwire through orthodontic brackets is differently affected by variant designs and ingredients of brackets and archwires and bracket-archwire angles. In order to simulate the situations which could occur during orthodontic treatment with fixed appliances, 4 types of brackets (Gemini, a stainless steel twin bracket, Mini Uni-Twiu. a stainless steel bracket with a single bracket design and narrow mesio-distal width; Clarity, a metal-reinforced ceramic bracket; Transcend, a ceramic bracket) and 3 types of orthodontic archwires $(0.016',\; 0.016{\times}0.022'\;stainless\;steel,\;0.016'\;Nitinol)$ were used and the bracket-archwire angles were controlled as $0^{\circ},\;3^{\circ}\;6^{\circ},\;and\;9^{\circ}$ Gemini significantly show and the lowest static and kinetic frictions (P<0.001) Clarity showed the highest static and kinetic frictions with a bracket-archwire angle of $0^{\circ}$. and Transcend at $6^{\circ}\;and\;9^{\circ}$ (P<0.001). An $0.016{\times}0.022'$ stainless steel rectangular archwire significantly showed the highest static and kinetic frictions (P<0.01). The lowest static and kinetic frictions were observed when the bracket-archwire angles were $0^{\circ}\;and\;3^{\circ}$ with 0.010' stainless steel round archwires (P<0.01), and $6^{\circ}\;and\;9^{\circ}$ with 0.016 Nitinol (P<0.001). The static and kinetic frictions were increased as the bracket-archwire angles were increased (P<0.001)

Cleft lip and palate patient treatment using self-ligating bracket and distraction osteogenesis: A case report (자가결찰 브라켓과 골신장술을 이용한 구순구개열 환자의 치험례)

  • Moon, Cheol-Hyun;Park, Sun-Kyu
    • The Journal of the Korean dental association
    • /
    • v.47 no.10
    • /
    • pp.656-668
    • /
    • 2009
  • It is difficult to perform orthodontic treatment for cleft lip and palate patient. Although there are many orthodontic appliances to expand narrowed maxillary arch, results are rarely successful and the possibility of relapse is increased due to severe scars. Self-ligating bracket, recently used in orthodontic treatment, suggests solution of crowding by expansion of dental arches. Light and continuous force could apply for orthodontic movement due to characteristic low friction of self ligating bracket, which gives expansion force until dentition reaches its new equilibrium position and it can be expressed as spontaneous lateral expansion with heavy labial tension. This kind of expansion force is thought to be a possibility of expanding the constricted maxillary arch of cleft lip and palate patient. Repositioning of the maxilla by Le Fort I osteotomy in case of severe maxillary deficiency, increases the possibility of relapse because of limitation in anterior movement and adaptation of soft tissue. In these cases, distraction osteogenesis(DO) can be applied for stable result. We report a case of cleft lip and palate patient with narrowed maxillary arch and maxillary deficiency using self ligating bracket and DO.

  • PDF

A Study on Improvement of Correction Bracket Performance Using Optimal Structural Design (최적구조설계를 이용한 교정브라켓 성능향상에 관한 연구)

  • Li, Jung Hua;Kweon, Hyun Kyu;Gwon, Dong Jae;Park, Sang Jun;Jeon, Yoo Jin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • There has always been a demand for orthodontic treatment. Orthodontic treatment allows tooth to be arranged by flexible arch wire fixed with tooth-attached brackets. Arch wire generate constant pressure to tooth brackets which moves the teeth to proper place. When the bracket transmits force, the braced wing of the bracket may deform. Deformed tie wing will lead to lost tension of elastic ligature. Then, lacking grip between tie wing and ligature might delay the tooth movement. Furthermore, tooth brackets used for orthodontic treatment make contact with in direct oral surface and this cause feeling of irritation that comes from height of tooth braces. This study suggests an optimal teethe bracket design to make up for inconvenience by shorten the height of bracket and complement the shape of bracket to reduce strain rate using finite element analysis. As a result, new optimal design of teethe bracket indicates lower strain rate of the bracket wing and takes good effects of shorten body height in terms of convenience.

A STUDY ON THE CHANCES OF FRICTIONAL FORCE BETWEEN BRACKET AND ORTHODONTIC WIRE WITH TIME IN ARTIFICIAL SALIVA (시간경과에 따른 교정용 bracket과 교정선 사이의 마찰력 변화에 관한 연구)

  • Kwak, Chun;Kim, Jim-Bom;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.23 no.2 s.41
    • /
    • pp.283-294
    • /
    • 1993
  • The friction of orthodontic appliances is recogonized to be detrimental to tooth movement. The purpose of this study was to determine the magnitude of frictional force changes between bracket$(018'\times025'\;solt)$ and orthodontic wires(stainless steel, cobalt-chromium, and $\beta-titanium$, $017'\times0.25'$ rectangular) with time. The wire was secured in the bracket slot with a elastomeric ligature. Frictional forces were measured by universal testing machine. The following conclusions were obtained. 1. The frictional forces under dry condition were greater than those in saliva. 2. The frictional forces produced by cobalt-chromium wire were less than those generated by stainless steel and $\beta-titanium$ wire. 3. The frictional forces increased progressively with time, and the amount of increase on first two weeks was greater than on last two weeks. 4. The change of frictional force under dry condition was greater than in artificial saliva.

  • PDF

A STUDY OF ENAMEL DEMINERALIZATION RELATED TO BENDED ORTHODONTIC BRACKET AND IMPROVED METHOD OF ENAMEL DEMINERALIZATION: IN VIVO STUDY (BRACKET 부착에 의한 법랑질 표면의 탈회 및 개선 방법에 관한 연구)

  • Son, Han-Sin;Lee, Dong-Joo
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.165-174
    • /
    • 1995
  • The purpose of this study was to evaluated the improve method of demineralization and damage on the enamel stufece related to bonded orthodontic bracket. Enamel surface of the 40 Intact premolars were treated by aicd etching and various fluoride application methods and then maintained in the patient mouth of 3 months. After extraction of all the sampled premolars, enamel surfaces were evaluated by Scanning electron microscope. The obtained results were as follow. 1. Enamel surface relate to bonded orthodontic bracket showed demineralization and damage, slightly. 2. Group 6 treated by $2\%$ NaF iontophoresis presented and almost similarity to nomral enamel surface. 3. Group 2 treated by acid etching had demineralization and damage on the enamel surface much more than other groups treated by various fluoride application methods. 4. Demineralization and damage on the enamel surface caused by bonded orthodontic bracket is improved by various fluoride application methods.

  • PDF

Biomechanical analysis of distalization of mandibular molars by placing a mini-plate: A finite element study

  • Park, Myungsoon;Na, Yonghyun;Park, Minbong;Ahn, Janghoon
    • The korean journal of orthodontics
    • /
    • v.47 no.5
    • /
    • pp.289-297
    • /
    • 2017
  • Objective: The objective of this study was to analyze the patterns of tooth movements when distalization of mandibular molars using a mini-plate took place. A finite element analysis was applied to analyze patterns of tooth movements. Methods: The model of the mandible and teeth were used to build a finite element analysis model, and a mini-plate was inserted in the mandibular ramus. Two different orthodontic forces were established for displacement of mandibular molars. Orthodontic forces were applied at the level of the bracket and at the level of the cemento-enamel junction in the mandibular canine respectively. Results: Applying orthodontic forces at the level of the cemento-enamel junction resulted in a greater biomechanical bodily movement in distalization of the mandibular molars compared to when the orthodontic forces were applied at the level of the bracket. Applying orthodontic forces to the cemento-enamel junction also resulted in unwanted greater extrusive movements in distalization of the mandibular molars compared to the bracket level. Conclusions: With considering the mode of orthodontic teeth movement, applying different vertical orthodontic forces for distalization of mandibular molars can lead to more effective distalization of teeth.

A Study on Frictioal Resistance Force of Orthodontic Resin Bracket (교정용 Resin bracket의 마찰 저항력에 관한 연구)

  • Lee, Won-you;Lim, Kyung-Soo
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.107-112
    • /
    • 1999
  • As increasing number of adult patients, the esthetic orthodontic appliances are needed. They are tooth-colored or translucent ceramic and resin brackets. Although ceramic and resin bracket have good esthetics, there are some disadvantage such as frictions. Recently, metal-reinforced resin bracket(MRBB) were introduced. The purpose of this study is to find frictional force of MRRB, ceramic bracket and resin brackets. There is few study in frictional force about metal reinforced resin bracket(MRRB). This study used 4 orthodontic wire(.016 S-S, .0l6X.022 S-S, .016 $TMA^{\circledR}$, .0l7X.025 $TMA^{\circledR}$ and 5 brackets(one metal bracket, one ceramic bracket, one resin bracket, two MRRB). The following result is obtained using metal bracket(Ormco.Co., U.S.A), ceramic brackets($Crystalline^{\circledR}$), resin bracket( Clear Medium $Siamase^{\circledR}$). Following conclusions are obtained. 1. Ceramic and resin bracket have significantly more frictional forces than metal reinforced resin bracket and metal bracket. 2. There is no significant difference in frictional force according to the slot types of metal - reinforced resin brackets. 3. There is no significant difference in frictional force between metal reinforced resin bracket and metal bracket. 4.. Frictional force is decreased in S-S wire than TMA wire.

  • PDF

Adherence of Salivary Proteins to Various Orthodontic Brackets (다양한 교정용 브라켓 표면에 부착하는 타액단백질에 관한 연구)

  • Ahn, Sug-Joon;Ihm, Jong-An;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.443-453
    • /
    • 2002
  • The principal aims of this study were to identify the composition of salivary pellicles formed on various orthodontic brackets and to obtain a detailed information about the protein adsorption profiles from whole saliva and two major glandular salivas. Four different types of orthodontic brackets were used. All were upper bicuspid brackets with a $022{\times}028$ slot Roth prescription; stainless steel metal, monocrystalline sapphire, polycrystalline alumina, and plastic brackets. Bracket pelicles were formed by the incubation of orthodontic brackets with whole saliva, submandibular-sublingual saliva, and parotid saliva for 2 hours. The bracket pellicles were extracted and confirmed by employing sodium dodecyl sulfatepolyacrylamide gel electrophoresis, Western transfer methods, and immunodetection. The results showed that low-molecular weight salivary mucin, ${\alpha}-amylase$, secretory IgA (sIgA), acidic proline-rich proteins, and cystatins were attached to all of these brackets regardless of the bracket types. High-molecular weight mucin, which promotes the adhesion of Streptococcus mutans, did not adhere to uy orthodontic brackets. Though the same components were detected in all bracket pellicles, however, the gel profiles showed qualitatively and quantitatively different pellicles, according to the origins of saliva and the bracket types. In particular, the binding of sIgA was more prominent in the pellicles from parotid saliva and the binding of cystatins was prominent in the pellicles from the form plastic brackets. This study indicates that numerous salivary proteins adhere to the orthodontic brackets and these salivary proteins adhere selectively according to bracket types and the types of the saliva.

FRICTIONAL FORCES IN THE FIXED ORTHODONTIC APPLIANCE DURING TOOTH MOVEMENT (고정성 교정장치를 이용한 치아이동시 발생되는 마찰력)

  • Cho, Myeong-Sook;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.20 no.2
    • /
    • pp.409-417
    • /
    • 1990
  • Tooth movement would be impeded by frictional force arised between archwire and tube, bracket or elastics in the fixed orthodontic appliances, which could be changed variably by such several factors as the contact area, normal (perpendicular) force and the condition of contact surface. There were many literatures about frictional force in the orthodontic region, but different results were obtained from little controlled research so that was very difficult in clinical application. Therefore we have reviewed comprehensively previous literatures about frictional force and thus several results were obtained as follows: 1. For use species of the orthodontic wire, frictional force was influenced mainly by surface roughness of wire in the absence of binding, while that was influenced mainly by normal force in high binding angulation. 2. For the cross-section and diameter of the wire, the contact area influenced mainly on frictional force in the absence of binding, while wire stiffness influenced mainly on frictional force in high binding angulation. 3. The greater the bracket width, the greater frictional force, and frictional force of the plastic bracket was larger than that of the metal bracket. 4. For ligation type, frictional force of the stainless steel ligation was larger than that of the elastic ligation, and frictional force was directly proportional to ligation force. 5. Variable frictional force were occured from the saliva combined with such another factors as normal force and mode of surface oxide et al.

  • PDF