• Title/Summary/Keyword: orifice method

Search Result 215, Processing Time 0.025 seconds

A Study on Flow Rate Estimation Using Pressure Fluctuation Signals in Pipe (배관내 압력변동 신호를 이용한 유량 추정 방법 연구)

  • Jeong Han Lee;Dae Sic Jang;Jin Ho Park
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.2
    • /
    • pp.155-162
    • /
    • 2023
  • In nuclear power plants, the flow rate information is a major indicator of the performance of rotating equipment such as pumps, and is a very important one required for facility operation and maintenance. To measure a flow rate, various types of methods have been developed and used. Among them, the differential pressure type using orifice and the direct doppler type using ultrasonic waves are the most commonly used. However, these flow rate measurement methods have limitations in installation, conditions and status of the measuring part, etc. To solve this problem, we have studied a new technique for measuring flow rate from scratch. In this paper, we have devised a technique to estimate the flow rate using an average moving velocity of large-scale eddy in turbulence that occurs in the piping flow field. The velocity of the large-scale eddy can be measured using the pressure fluctuation signals on the inner surface of the pipe. To estimate the flow rate, at first a cross-correlation function is applied to the two pressure fluctuation signals located at different positions in the down stream for calculating the time delay between the moving eddies. In order to validate the proposed flow rate estimation method, CFD analyses for the internal turbulence flow in pipe are conducted with a fixed flow condition, where the pressure fluctuation signals on the pipe inner surface are simulated. And then the average flow velocity of the large scale eddy is to be estimated. The estimated flow velocity is turned out to be similar to the fixed (known) flow rate.

Repair of Complete Atrioventricular Septal Defect with Surgical Modification (변형술식에 의한 완전방실중격결손의 교정)

  • 김웅한;김수철;이택연;한미영;정철현;박영관;김종환
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.628-636
    • /
    • 1999
  • Background: Recent advances in understanding the anatomy of the complete atrioventricular septal defect(including right-dominant unbalanced atrioventricular septal defect) have led to alternative methods of repairing these defects. Material and Method: From May 1997 to July 1998, 8 consecutive infants(age range, 2 to 28 months, mean body weight 6.0$\pm$2.2 kg) received a single-stage intracardiac repair of the complete atrioventricular septal defect with modified surgical methods. Depending on the specific anatomic structure, the procedure was simplified in 3 patients by a direct closure of the ventricular element of the defect(Group I). Two patients judged unsuitable for direct closure due to a potential left ventricular outflow tract obstruction had received a standard two-patch repair(Group II). The remaining 3 patients with right-dominant unbalanced complete atrioventricular septal defect underwent biventricular repair; to enlarge the orifice of the left atrioventricular valve, the ventricular septal patch was placed slightly more to the right of the ventricular crest, a left sided bridging leaflet was augmented with an autologous pericardial patch, and the leaflet was repaired with a double- orifice(Group III . Result: In all 8 patients, the postoperative echocardiography demonstrated good hemodynamics. Seven patients were weaned from the ventilators after a mean 3$\pm$1 days, and 1 patient was weaned after 24 days due to a reoperation and emphysematous lung problem. A reoperation was performed in 1 patient for progressive left atrioventricular valve regurgitation due to leaflet tearing. There were no early and late mortalities. At the time of the latest review, judging from the echocardiographic criteria, left atrioventricular valve stenosis was mild in 1 patient(mean pressure gradient 6.5 mmHg, 13.5%), left atrioventricular valve regurgitation was absent or grade I in 7 patients(87.5%). The right atrioventricular valve regurgitation was absent or grade I in all 8 patients(100%). Conclusion: Infants with complete atrioventricular septal defect were treated with either a simplified approach with direct closure of the ventricular element of the defect or a modified surgical technique for a right-dominant unbalanced atrioventricular septal defect, depending on the anatomic structure. The results were no operative mortalities and low morbidity.

  • PDF

Small Aortic Annulus in Aortic Valve Replacement; Comparison between Aortic Annular Enlargement Group and Patient-prosthesis Mismatch Group (협소한 대동맥판륜 환자에서의 대동맥판막 치환술; 대동맥판륜 확장술군과 환자-인공판막 부조화군의 비교)

  • Kim, Jae-Hyun;Oh, Sam-Sae;Yie, Kil-Soo;Shin, Sung-Ho;Baek, Man-Jong;Na, Chan-Young
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.200-208
    • /
    • 2007
  • Background: The effect of patient-prosthesis mismatch (PPM) on the clinical outcome following aortic valve replacement (AVR) remains controversial. This study compared the surgical outcomes of AVR between patients with a patient-prosthesis mismatch and those having undergone an aortic annular enlargement. Material and Method: Six hundred and twenty seven adult patients, who underwent AVR with stented bioprosthetic or mechanical valves, between January 1996 and February 2006, were evaluated. PPM was defined as an indexed effective orifice area (iEOA) ${\leq}0.85cm^2/m^2$, and Severe if the iEOA${\leq}0.65cm^2/m^2$ PPM was present in 103 (16.4%, PPM group) patients, and severe in 11 (1.8%, SPPM group). During the period of the study, 21 patients underwent an AVR with annular enlargement (AE group). Result: The mean iEOA of the AE group was larger than that of the PPM group ($0.95\;vs.\;0.76cm^2/m^2,\;p=0.00$). The AE group had longer CPB, ACC and operation times than the PPM group, and showed a tendency toward higher operative mortality (14.3% vs. 2.9%, p=0.06). The SPPM group had higher AV pressure gradients (peak/mean) than the AE group (72/45 mmHg vs. 38/25 mmHg, p=0.02/0.06) and suffered more AV related events (AV reoperation or severe aortic stenosis)(45.5% vs. 9.5%, p=0.03). LV masses were not regressed in the patients who experienced an AV related event. Conclusion: During AVR in patients with a small aortic annulus, annular enlargement should be carefully applied taking into account the high risk of operative mortality due to annular enlargement and co-morbidities of patients. Aortic annular enlargement; however, should be considered as an alternative method in patients expected to have a severe PPM after an AVR.

Study on the Changes of Dentinal Hypersensitivity and Surface Characteristics Following the Various Root Treatment (수종의 치근면 처치 방법에 따른 상아질 지각 과민 변화 및 표면 특성에 관한 연구)

  • Kwon, Soon-Young;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.51-63
    • /
    • 1999
  • Exposure of the root surface due to gingival recession after periodontal surgery, elicit pain response when exposed to mechanical, heat, chemical or osmotic irritation. Especially patients treated with periodontal surgery, show high frequency. There have been reports that the 1 out of 7 patients complains of dentinal hypersensitivity. There have been many studies on the clinical effects of various materials on the treatment of dentinal hypersensitivity. The purposes of this study were to evaluate the effect of sodium chloride and potassium oxalate and to observe the relationship between the dentinal hypersensitivity and surface characteristics such as dentinal tubule size and number. This study included 20 teeth which were scheduled for extraction and had no pulpal disease. These teeth were divided into Root planing group, EDTA group, NaCl group and Oxalate group. Dentinal hypersensitivity is measured by tactile, pressured air and cold water using NRS (Numerical Rating Scales). Teeth were extracted under local anesthesia and each specimen was sectioned to a size about 3 X 5 mm and was examined under the scanning electron microscope (X2,000) The results were as follows, 1. The EDTA group exhibited significantly increased dentinal hypersensitivity comparing with the other groups. 2. The NaCl and Oxalate groups showed significantly reduced dentinal hypersensitivity comparing with the EDTA group. 3. As a method for dentinal hypersensitivity measurement, it was presumed thet tactile sensitivity test was not sensitive method but air blast test and cold water test were adequate method. 4. In a SEM study, the root planing group exhibited amorphous smear layer and showed no dentinal tubule orifice, but the EDTA group showed the large number of dentinal tubules. On the other hand, the NaCl and Oxalate groups did not show exposed dentinal tubules. The NaCl group showed more rough root surface than the EDTA group, and the Oxalate group showed many participates to be presumed as calcium oxalate particle. As the results from this study, root planing couldn't expose the dentinal tubule and NaCl and potassium oxalate occluded exposed dentinal tubule effectively. Dentinal hypersensitivity has close relationship with the exposure of dentinal tubules, especially with it's size and number.

  • PDF

A Review on Spray Characteristics of Bioethanol and Its Blended Fuels in CI Engines

  • No, Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.19 no.4
    • /
    • pp.155-166
    • /
    • 2014
  • This review will be concentrated on the spray characteristics of bioethanol and its derived fuels such as ethanol-diesel, ethanol-biodiesel in compression ignition (CI) engines. The difficulty in meeting the severe limitations on NOx and PM emissions in CI engines has brought about many methods for the application of ethanol because ethanol diffusion flames in engine produce virtually no soot. The most popular method for the application of ethanol as a fuel in CI engines is the blending of ethanol with diesel. The physical properties of ethanol and its derivatives related to spray characteristics such as viscosity, density and surface tension are discussed. Viscosity and density of e-diesel and e-biodiesel generally are decreased with increase in ethanol content and temperature. More than 22% and 30% of ethanol addition would not satisfied the requirement of viscosity and density in EN 590, respectively. Investigation of neat ethanol sprays in CI engines was conducted by very few researchers. The effect of ambient temperature on liquid phase penetration is a controversial topic due to the opposite result between two studies. More researches are required for the spray characteristics of neat ethanol in CI engines. The ethanol blended fuels in CI engines can be classified into ethanol-diesel blend (e-diesel) and ethanol-biodiesel (e-biodiesel) blend. Even though dodecanol and n-butanol are rarely used, the addition of biodiesel as blend stabilizer is the prevailing method because it has the advantage of increasing the biofuel concentration in diesel fuel. Spray penetration and SMD of e-diesel and e-biodiesel decrease with increase in ethanol concentration, and in ambient pressure. However, spray angle is increased with increase in the ethanol percentage in e-diesel. As the ambient pressure increases, liquid phase penetration was decreased, but spray angle was increased in e-diesel. The increase in ambient temperature showed the slight effect on liquid phase penetration, but spray angle was decreased. A numerical study of micro-explosion concluded that the optimum composition of e-diesel binary mixture for micro-explosion was approximately E50D50, while that of e-biodiesel binary mixture was E30B70 due to the lower volatility of biodiesel. Adding less volatile biodiesel into the ternary mixture of ethanol-biodiesel-diesel can remarkably enhance micro-explosion. Addition of ethanol up to 20% in e-biodiesel showed no effect on spray penetration. However, increase of nozzle orifice diameter results in increase of spray penetration. The more study on liquid phase penetration and SMD in e-diesel and e-biodiesel is required.

Separation of Dark and Ordinary Muscle with Specific Gravity Controlled Sugar Solutions (당용액비중조절에 의한 보통육과 혈합육의 분리에 관한 연구)

  • KIM Woo-Jun;LEE Kang-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.15 no.3
    • /
    • pp.185-190
    • /
    • 1982
  • In utilization of small size red muscled fishes like mackerel, sardine, and filefish, mechanical dressing is usually required. The removal of dark muscle is also necessary to improve qualify of the product, which could hardly be done by mechanical process. As a method of separating dark muscle, specific gravity method using sugar solution was investigated in this study. And the effects of the level of specific gravity, the size and density of meat particles, and stability of meat particle float on the separation of dark muscle were discussed. From the results, effective specific gravity, in case of sucrose solution, ranged 1.067 to 1.072 for mackerel, 1.062 to 1.070 for sardine, and 1.072 to 1.077 for filefish, respectively. The maximum separation of more than $90\%$ was obtained at specific gravity of 1.075, 1.070, and 1.075 in cases of mackerel, sardine and filefish, respectively. The size of meat particles which were ground with 0.2cm orifice plate was adequate to yield $90\%$ separation or above. The meat particle float in the glucose solution began to precipitate within 5 minutes after separation while 25 minutes in case of sucrose solution. Lipids were also fairly removed by the dark muscle separation process.

  • PDF

In-Vitro Thrombosis Detection of Mechanical Valve using Artificial Neural Network (인공신경망을 이용한 기계식 판막의 생체외 모의 혈전현상 검출)

  • 이혁수;이상훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.429-438
    • /
    • 1997
  • Mechanical valve is one of the most widely used implantable artificial organs of which the reliability is so important that its failure means the death of patient. Therefore early noninvasive detection is essentially required, though mechanical valve failure with thrombosis is the most common. The objective of this paper is to detect the thrombosis formation by spectral analysis and neural network. Using microphone and amplifier, we measured the sound from the mechanical valve which is attached to the pneumatic ventricular assist device. The sound was sampled by A/D converter(DaqBook 100) and the periodogram is the main algorithm for obtaining spectrum. We made the thrombosis models using pellethane and silicon and they are thrombosis model on the valvular disk, around the sewing ring and fibrous tissue growth across the orifice of valve. The performance of the measurment system was tested firstly using 1 KHz sinusoidal wave. The measurement system detected well 1KHz spectrum as expected. The spectrum of normal and 5 kinds of thrombotic valve were obtained and primary and secondary peak appeared in each spectrum waveform. We find that the secondary peak changes according to the thrombosis model. So to distinguish the secondary peak of normal and thrombotic valve quantatively, 3 layer back propagation neural network, which contains 7, 000 input node, 20 hidden layer and 1 output was employed The trained neural network can distinguish normal and valve with more than 90% probability. As a conclusion, the noninvasive monitoring of implanted mechanical valve is possible by analysing the acoustical spectrum using neural network algorithm and this method will be applied to the performance evaluation of other implantable artificial organs.

  • PDF

THE EFFECT OF SOME CANAL PREPARATION TECHNIQUES ON THE SHAPE OF ROOT CANALS (수종의 근관형성 방법이 근관 형태에 미치는 영향)

  • Lee, Ji-Hyeon;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.337-345
    • /
    • 1999
  • The purpose of this study was to compare the shape of root canal after instrumentation with some engine driven NiTi files. Thirty narrow and curved canals(15-35 degree) of mesial canals of extracted human mandibular first molars were divided into three groups. Group 1: After radicular access with Gates Glidden drill, apical shaping using step back method with Flexo file Group 2: After radicular access with Gates Glidden drill, apical shaping with Profile .04 Group 3: Canal shaping with GT file and Profile .04. Using modified Bramante technique, the root was sectioned at 2 mm from apical foramen, height of curvature, 2 mm from canal orifice. Canal centering ratio, amount of transport, amount of dentin removed, shape of canal were measured and statistical analysis is done using SPSS Program V 7.5. The results were as follows: 1. Canal centering ratio of group 3 was the lowest at coronal part, but there was no statistical difference. Centering ratio of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistic difference. 2. Amount of transport of group 3 was the lowest at coronal part, but there was no statistical difference. Amount of transport of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Amount of transport of group 3 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 3. Amount of dentin removed of group 3 was the lowest at coronal part, bur there was no statistical difference. Amount of dentin removed of group 2 was the lowest at curve part, but there was no statistical difference. Amount of dentin removed or group 2 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 4. The shape of the canals after instrumentation varied among the groups. The majority of canals at coronal and curve part for group 1 were round in shape(7 in 10), those at apical part were oval(8 in 10). The majority of canals at coronal part for group 2 were round in shape(7 in 10) and there was no difference in the number of shape at other part. There was no difference in the number of shape at every part for group 3. As above results, NiTi rotary instrumentation showed a trend to remain more centered in the canal than SS file instrumentation. At using NiTi file, coronal shaping with Gates Glidden drill was not statistically different from shaping with GT file. But shaping with GT file showed tapered canals, so it may be said that shaping with GT file is a safe and valuable instrumentation method.

  • PDF

Mitral Valve Repair for Mitral Regurgitation in Pediatric Patients (승모판폐쇄부전증를 가진 소아 환자에서 승모판성형술의 임상적 고찰)

  • Sim, Hyung-Tae;Yun, Tae-Jin;Park, Jeong-Jun;Jung, Sung-Ho;Uhm, Ju-Yeon;Jhang, Won-Kyoung;Kim, Young-Hwue;Ko, Jae-Kon;Park, In-Sook;Seo, Dong-Man
    • Journal of Chest Surgery
    • /
    • v.40 no.8
    • /
    • pp.536-545
    • /
    • 2007
  • Background: Compared to adult patients, mitral regurgitation in pediatric patients is uncommon and it shows a wide spectrum of morphologic abnormalities. We retrospectively evaluated the midterm results of mitral valve repair in pediatric patients. Material and Method: Between December 1993 and August 2006, mitral valve repair was performed in 35 patients who were aged less than 18 years, The mean age was $5.3{\pm}5.3$ years and the mean body weight was $20,0{\pm}16.3\;kg$. 18 patients had associated cardiac anomalies. The most common pathologic finding was leaflet prolapse (n=17). The most common method of repair was the double orifice technique (n=15). Result: There was no early mortality. Eight patients underwent reoperation (24.2%), and five of them required mitral valve replacement. Among the four ring annuloplasty cases, two have developed mitral stenosis. Four out of the 14 double orifice cases required reoperation. One case of early mortality and one case of late mortality occurred in the reoperation cases. The 5-year survival rate and the freedom from reoperation rate were $93.3{\pm}4.6%$ and $76.1{\pm}8.2%$, respectively. The 5-year freedom from mitral valve replacement rate was $83.6{\pm}6.7%$. There was no significant risk factor for reoperation. Conclusion: The midterm results of mitral valve repair are very acceptable in pediatric patients compared to the adult cases, although the reoperation rate is slightly higher.

Performance Evaluation of 1 N Class HAN/Methanol Propellant Thruster (HAN/메탄올 추진제를 사용하는 1 N급 추력기 성능 평가)

  • Lee, Jeongsub;Huh, Jeongmoo;Cho, Sungjune;Kim, Suhyun;Park, Sungjun;Kim, Sukyum;Kwon, Sejin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.4
    • /
    • pp.299-304
    • /
    • 2013
  • The HAN which is an ionic liquid is a non-toxic monopropellant with high storability, and its specific impulse can be increased by blending methanol, thereby it can substitute the hydrazine. The HAN was synthesized by acid-base reaction of hydroxylamine and nitric acid, and the blending ratio of HAN and methanol is 8.2:1. The iridium catalyst was used to decompose the HAN, and 1 N class thruster with shower head type injector having one orifice was used to evaluate the HAN/Methanol propellant. The thermal stability of distributor was increased by using ceramic material to endure the high temperature of product gas. The preheating temperature of catalyst should be $400^{\circ}C$ at least for the complete decomposition. The feeding pressure should be increased to increase the $C^*$ efficiency, thereby the decomposition performance was decreased upstream catalyst, and the performance of thruster was decreased. The fine metal mesh was inserted after the injector to improve the atomization of propellant, thereby it can settle the performance decrease problem. The phenomenon of performance decrease was remarkably improved owing to the insertion of fine metal mesh.