• Title/Summary/Keyword: orifice method

Search Result 215, Processing Time 0.03 seconds

A study on the Effect of Heat Treatment of Co-bused Amorphous Ribbons (Co-계비정질 리본의 열처리 효과에 관한 연구)

  • 진성빈;임재근;문현욱;신용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.149-151
    • /
    • 1994
  • This thesis describes the effect of heat treatment on the magnetic properties of Co-bsaed Amorphous. A sample was chosen as basic composition with Co$\_$82//Si$\_$2//B$\_$16/ of zero magnetostriction. It was made by single roll method with quartz orifice 0.5[mmø], Ar gas pressure 0.6 [kg/cm$^2$] and roll speed 28 (m/sec) and atmosphere is ,Ar gas. We obtained the sample of width 2.4(mm), thickness 45[$\mu\textrm{m}$]. Made sample annealed for the improvement of magnetic propertics at at annealing temperature 325,350,375 and 400$^{\circ}C$ and annealing time 15, 30, 45, 60 and 120min respectiveily. Amorphous ribbon of co-based showed high permeab- ility ${\mu}$=8000∼14000, and became improvement of magnetic properties according to anneal ins temperature and time. Especially. Amorphous sample at 325$^{\circ}C$ ,45min appearanced high permeability ${\mu}$=13, 589 at frequency f= 100Hz. and loss factor was reduced at low frequency with rising anneal ins ti me and temperature more annealed sample than basic sample.

  • PDF

An Investigation on the Macroscopic Spray Behavior of Nonimpinging-type Injector through Optical Measurement Technique (광학계측기법에 의한 비충돌형 인젝터의 거시적 분무거동 고찰)

  • Kim, Jong-Hyun;Jung, Hun;Kim, Jeong-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.143-148
    • /
    • 2012
  • This study is an investigation on macroscopic spray behavior of nonimpinging-type injector equipped on the hydrazine thruster under development. An electron microscope is employed for the acceptance examination of injector orifice. Initial performance characteristics and spray behavior of injector are observed through the instantaneous spray images which are captured by high speed camera and Schlieren method with varying injection pressures. The injector performance is scrutinized by the velocity along with penetration length of spray and categorized by dimensionless parameters. It is confirmed that there exist varying characteristics related to the spray breakup caused by fabrication errors of injector-orifices. Unexpected spray behavior, which needs to be reexamined, is grasped at specific pressure level, as well.

  • PDF

Precise correction of the copper emission spectra from the pulsed plasma jet (펄스 플라즈마 제트내에 있는 구리원자의 발광 스펙트럼 정밀 보정)

  • 김종욱;고동섭;오승묵
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.2
    • /
    • pp.115-120
    • /
    • 2001
  • In the present study, we described in detail a precise correction method of the copper emission spectra obtained from a highpressure and high-temperature pulsed plasma-jet. The pulsed plasma-jet is initiated from an electro-thermal capillary discharge through a small orifice, and expanded rapidly into an atmosphere. In order to characterize the plasma, fundamental measurements such as the plasma excitation temperature or electron number density are essential. However those spectral lines which are directly related to the excitation temperature or electron number density may be distorted by the spectral response of the optical instruments used. Therefore, in this paper, we discuss some efforts to derive precise correction methods of the copper emission spectra obtained from the pulsed plasma-jet. a-jet.

  • PDF

Flow characteristics validation around drain hole of fan module in refrigerator (냉장고 팬 모듈의 물빠짐 구멍 주변 유동 특성 검증)

  • Jinxing, Fan;Suhwan, Lee;Heerim, Seo;Dongwoo, Kim;Eunseop, Yeom
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.102-108
    • /
    • 2022
  • In the fan module of the intercooling refrigerator, a drain hole structure was designed for stable drainage of defrost water. However, the airflow passing through the drain hole can disturb flow features around the evaporator. Since this backflow leads to an increase in flow loss, the accurate experimental and numerical analyses are important to understand the flow characteristics around the fan module. Considering the complex geometry around the fan module, three different turbulence models (Standard k-ε model, SST k-ω model, Reynolds stress model) were used in computational fluid dynamics (CFD) analysis. According to the quantitative and qualitative comparison results, the Standard k-ε model was most suitable for the research object. High-accuracy results well match with the experiment result and overcome the limitation of the experiment setup. The method used in this study can be applied to a similar research object with an orifice outflow driven by a rotating blade.

Determination of State-Space Model for Parameter Estimation of Tank Model (탱크모형의 매개변수추정을 위한 상태공간모형의 결정)

  • 이관수;이영석;정일광
    • Water for future
    • /
    • v.28 no.2
    • /
    • pp.125-136
    • /
    • 1995
  • The propose of this study is improve the uncertainty of parameter choice of tank model by the trials and errors method. The real time prediction of parameter by using the Kalman filter is practiced to get the effective prediction algorithm of low flow runoff. Even though the total discharge of runoff through the orifice of each tank should be similar to the observed discharge, the tank model which can show the various basin characteristic is influenced by the runoff circumstances. As a result of the real-time estimation of the tank model parameter by the state-space type of Kalman filter, the variation of runoff circumstances is static when the convergence of observed value and estimated value keeps the ficed high point. The parameter of tank model which is estimated by Kalman filter shows good result for low flow and reasonable adaptability where flow change abruptly. The Kalman filter method is proved to give better result than Automatic structure estimation method.

  • PDF

A Study on the Non-evaporating Diesel Spray Characteristics as a Function of Ambient Pressure in Constant Volume Combustion Chamber (정적챔버에서 분위기 압력에 따른 비증발 디젤분무특성 연구)

  • Jeon, Chung-Hwan;Jeong, Jeong-Hoon;Kim, Hyun-Kyu;Song, Ju-Hun;Chang, Young-June
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.645-652
    • /
    • 2010
  • The aim of this investigation was study on the non-evaporation diesel spray characteristics injected through a common-rail diesel injector under various ambient pressure. The diesel spray was investigated with observation of macroscopic characteristics such as spray tip penetration and spray cone angle by the shadowgraph and the image processing method. The numerical study was conducted using a computational fluid dynamics code, AVL-FIRE. The breakup models used were WAVE model and standard $k-{\varepsilon}$ turbulence model was applied. The numerical study used input data which spray cone angle and fuel injection rate was achieved by Zeuch's method. Comparison with experimental result such as spray tip penetration was good agreement. Distribution of droplet diameter were conducted on four planes where the axial distances were 5, 15, 39 and 49mm respectively downstream from the orifice exit.

NUMERICAL STUDY ON THE FLOW CHARACTERISTICS OF A HYDRAULIC PISTON PUMP BASED ON THE ANGLE OF THE SWASH-PLATE AND THE DISCHARGE PRESSURE (유압 피스톤펌프의 토출압력 및 사판각도 변화에 따른 유동특성 해석)

  • Yoon, J.H.;Lee, K.;Kang, M.C.
    • Journal of computational fluids engineering
    • /
    • v.21 no.1
    • /
    • pp.50-57
    • /
    • 2016
  • In various industries related with construction and military machinery, a large amount of power is normally required because such machinery operations, such as digging or breaking, take place under difficult working conditions in a rough environment. Thus, a hydraulic system needs to be applied as the major power transfer system. To produce and supply hydraulic power depending on the various load conditions, a hydraulic piston pump is utilized as a typical power source for a hydraulic system. In the present study, numerical simulations were conducted using the commercial program, Ansys CFX 14.5. To lubricate the moving parts as the pump starts to operate, a small amount of oil leaks out through the clearance between the orifice in the piston-shoe and the recess at the swash-plate. Taking this into consideration, a cylindrically shaped computational domain was modeled to maintain the same equivalent leakage area. To validate the numerical method applied herein, the numerical results of the flow rate at the discharge port were compared with the experimental data, and a good agreement between them was shown. Using the verified method, the effects of the discharge pressure and the angle of the swash-plate were also evaluated under several load conditions. The results of the present study can be useful information for a hydraulic piston pump used in many different manufacturing industries.

Improvement of Gas Dissolution Rate using Air Atomizing Nozzle (이류체 노즐을 이용한 가스의 용존율 향상)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.27 no.3
    • /
    • pp.219-225
    • /
    • 2018
  • This study was conducted to investigate the possibility of utilizing various types of nozzles and gas-liquid mixers to increase the dissolution rate of plasma gas containing ozone generated in a dielectric barrier plasma reactor. After selecting the air atomizing nozzle with the highest gas dissolution rate among the 13 types of test equipment, we investigated the influence of the operating factors on the air atomizing nozzle to determine the optimal plasma gas dissolution method. The gas dissolution rate was measured by a simple and indirect method, specifically, the measurement of KLa instead of direct measurement of ozone concentration, which requires a longer analysis time. The results showed that the KLa value of the simple mix of air and water was $0.372min^{-1}$, Which is 1.44 times higher than that ($0.258min^{-1}$) of gas emitted from a normal diffuser. Among the nozzles of the same type, the KLa value was highest for the nozzle having the smallest orifice diameter. Among the 13 types of devices tested, the nozzle with highest KLa value was the M22M nozzle, which is a gas-liquid spray nozzle. The relationship between water circulation flow rate and KLa value in the experimental range was linear. The air supply flow rate and KLa value showed a parabolic-type correlation, while the optimum air supply flow rate for the water circulation flow rate of 1.8 L / min is 1.38 times.

Application of Bayesian Approach to Parameter Estimation of TANK Model: Comparison of MCMC and GLUE Methods (TANK 모형의 매개변수 추정을 위한 베이지안 접근법의 적용: MCMC 및 GLUE 방법의 비교)

  • Kim, Ryoungeun;Won, Jeongeun;Choi, Jeonghyeon;Lee, Okjeong;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.4
    • /
    • pp.300-313
    • /
    • 2020
  • The Bayesian approach can be used to estimate hydrologic model parameters from the prior expert knowledge about the parameter values and the observed data. The purpose of this study was to compare the performance of the two Bayesian methods, the Metropolis-Hastings (MH) algorithm and the Generalized Likelihood Uncertainty Estimation (GLUE) method. These two methods were applied to the TANK model, a hydrological model comprising 13 parameters, to examine the uncertainty of the parameters of the model. The TANK model comprises a combination of multiple reservoir-type virtual vessels with orifice-type outlets and implements a common major hydrological process using the runoff calculations that convert the rainfall to the flow. As a result of the application to the Nam River A watershed, the two Bayesian methods yielded similar flow simulation results even though the parameter estimates obtained by the two methods were of somewhat different values. Both methods ensure the model's prediction accuracy even when the observed flow data available for parameter estimation is limited. However, the prediction accuracy of the model using the MH algorithm yielded slightly better results than that of the GLUE method. The flow duration curve calculated using the limited observed flow data showed that the marginal reliability is secured from the perspective of practical application.

RETENTION OF PIT AND FISSURE SEALANT (치면열구전색의 유지력)

  • Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.336-347
    • /
    • 2006
  • Pit and fissure sealants has been proven as safe and effective method of caries prevention. But improper application of pit and fissure sealant may masking the caries process in occlusal fissure. Dentists have to understand the correct and exact application method of pit and fissure sealant for he good result of caries prevention. A key factor to enhanced the effectiveness of caries prevention is retention of pit and fissure sealant. Deep penetration of material into fissure and least marginal leakage around the fissure orifice are the major concerns for dentists to achieve the successive application of pit and fissure sealants. This paper reviewed the literature on the pit and fissure sealants under the following subtitles for enhanced retention : (1) application timing, (2) Indication, (3) Occlusal prophylaxis, (4) Materials, (5) Penetration, (5) Recall check Dental profession must perform the exact application of pit and fissure sealant because this procedure is one of the most technique-sensitive one in dental field.

  • PDF