• 제목/요약/키워드: orifice diameter

검색결과 281건 처리시간 0.036초

오리피스와 충돌하는 액적 거동에 관한 연구 (A Study on the Droplet Behavior Impacting on an Orifice)

  • 서동현;이덕진;이현빈;강보선
    • 한국분무공학회지
    • /
    • 제27권4호
    • /
    • pp.188-194
    • /
    • 2022
  • In this study, the behavior of water droplet impacting on a thin horizontal orifice was investigated. The impact behavior modes, transition velocities and diameters of daughter droplets were analyzed by changing the droplet velocity, orifice diameter and orifice thickness. Four typical modes of impacting droplet on an orifice were observed. The single-droplet and double-droplet transition velocities increased with increasing the orifice thickness and decreased with increasing the orifice diameter. On the other hand, the multi-droplet transition velocity decreased and then increased as the orifice diameter increased. At thin orifice thickness, the single droplet diameter approximated the orifice diameter, and increasing the orifice thickness produced a droplet larger than the orifice diameter. In the case of double droplet mode, the diameter of the first droplet showed a similar tendency like the single droplet mode, but the diameter of the second droplet was smaller than that of the first droplet, and the difference between them was affected more by the orifice thickness.

공기공급 시스템에 적용되는 Vortex Tube의 에너지 분리특성에 관한 연구(I) -저온출구 orifice의 직경변화에 의한 영향- (A Study for Energy Separation of Vortex Tube using Air Supply System (I) - the effect of diameter of cold end orifice -)

  • 이병화;추홍록;상희선
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.9-18
    • /
    • 1998
  • The vortex tube is a simple device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. Recently, vortex tube is widely used to local cooler of industrial equipments and air supply system. The phenomena of energy separation through the vortex tube was investigated experimentally. This study is focused on the effect of the diameter of cold end orifice diameter on the energy separation. The experiment was carried out with various cold end orifice diameter ratio from 0.22 to 0.78 for different input pressure and cold air flow ratio. The experimental results were indicated that there are an optimum diameter of cold end orifice for the best cooling performance. The maximum cold air temperature difference was appeared when the diameter ratio of the cold end orifice was 0.5. The maximum cooling capacity was obtained when the diameter ratio of the cold end orifice was 0.6 and cold air flow ratio was 0.7.

  • PDF

수리해석을 이용한 정수장내 혼화장치 설계 개선에 관한 연구 (Numerical Study on Improvement of Mixing Equipment' Plan in a Water Treatment Plant)

  • 오석영;현동수;오정진;이상흔;이남영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.777-782
    • /
    • 2001
  • In this study, we used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Numerical study was performed using FLUENT, a commercial code, to standard design and production of effective In-line orifice mixer. As variable for exactly standardizing, a proper ratio between an outer diameter of cone and a diameter of pipe, a distance between cone and orifice, a determination of orifice diameter for an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교 (A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field)

  • 안승희;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

정수장내 수류에너지를 이용한 액체약품의 효율적인 혼화를 위한 수리해석 (Numerical Study on effective Mixing Chemical Liquid using Hydraulic Energy in a Water Treatment Plant)

  • 송길섭;오석영
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2001년도 추계 학술대회논문집
    • /
    • pp.132-137
    • /
    • 2001
  • We used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Code of computational fluid dynamics for numerical analysis was performed using FLUENT, a commercial code. As variable for exactly standardizing, a proper ratio between an outer diameter of deflector and a diameter of pipe, the distance between deflector and orifice, a determination of orifice diameter fur an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

Orifice Type의 유압실린더 유동해석에 관한 연구 (Study on the hydraulic cylinder flow analysis of Orifice Type)

  • 배강열;전진성
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.54-59
    • /
    • 2015
  • This paper is a numerical study on the correlation of leakage by the variation of operating temperature and orifice diameter applying to hydrostatic bearing in hydraulic actuator. Compared with Brackbill and Kandlikar experimental paper to verify the validity of the numerical analysis technique of the present study, we derive the result that the results of experiments and numerical analysis to match very well. CFD analysis program were analyzed using a commercial code FLUENT V14.5. Inlet and outlet, were applied pressure conditions, the main variables of the analysis is temperature and the orifice inner diameter. The analysis results, pressure value has decreased as the oil temperature and the orifice diameter increases.

노즐 오리피스 형상 및 형상비가 디젤과 바이오디젤 연료의 노즐 내부 및 외부 유동특성에 미치는 영향 (Effect of Nozzle Orifice Shape and Nozzle Length-to-Diameter Ratio on Internal and External Flow Characteristics of Diesel and Biodiesel Fuel)

  • 박수한;서현규;이창식
    • 대한기계학회논문집B
    • /
    • 제31권3호
    • /
    • pp.264-272
    • /
    • 2007
  • The aim of this study is to investigate the effects of nozzle orifice shapes and the nozzle length-to-diameter ratio(L/D) on the nozzle cavitation formation inside the orifice and the external flow pattern. The nozzle used in this work was tested the taper orifice nozzle and the rectangular orifice nozzle which was made from the transparent acrylic acid resin. For studying the effect of the nozzle L/D ratio, it was used to three L/D ratios of 3.33, 10, and 20. The cavitation flow of nozzle was visualized by using the ICCD camera and optical system. This work revealed that the flow rate and discharge coefficient($C_d$) of the taper orifice nozzle was larger than those of the rectangular orifice nozzle at the same injection pressure. The cavitation flow was observed in the nozzle orifice at the low injection pressure and the breakup of liquid jet was promoted as the L/D ratio is decreased. The cavitation of biodiesel fuel was formed at the lower injection pressure than that of diesel fuel because of higher viscosity and density.

펌프 가압식 추진제 공급유로에서의 오리피스 개도에 따른 동적 수력특성 변화 (The Dynamic Characteristics of Pump-fed Hydraulics due to Different Diameter Ratios of the Plate Orifice)

  • 김형민;고태호;김상민;윤웅섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.313-317
    • /
    • 2009
  • 액체추진제로켓엔진의 추진제 공급유로 내 압력보정을 목적으로 설치된 오리피스는 엔진의 시동 및 정지시, 압력파를 발생시키는 원인이 되며 압력파로 인한 저주파 불안정을 막기 위해서는 오리피스의 개도에 따른 동특성의 변화를 살펴볼 필요가 있다. 오리피스의 동특성 변화를 확인하기 위해 오리피스 공급 압력을 급격하게 증가하도록 하였고 오리피스의 개도를 바꿔가며 동적인 압력변화를 측정하였다. 오리피스의 개도가 증가함에 따라 오리피스에 의한 수격현상은 감소하였으며 오리피스 하류의 수력학적 영향이 지배적으로 나타나는 것을 확인하였다.

  • PDF

회전연료노즐의 오리피스직경에 따른 분사특성연구 (A Study of Spray Characteristics of the Rotating Fuel Nozzle with Orifice Diameters)

  • 이매훈;장성호;이동훈;최성만
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.258-263
    • /
    • 2010
  • 고속회전 시험장치를 이용하여 V 형태의 회전식 연료 노즐의 오리피스 직경에 따른 분사특성을 파악하기 위한 연구를 수행하였다. 시험장치는 고속 회전장치, 연료공급장치, 아크릴 케이스로 구성하였다. 분무 오리피스의 직경과 회전속도를 변화시켜가며 분무실험을 수행하였다. 분무입자의 크기 및 속도 측정은 PDPA(Phase Doppler Particle Analyzer) 시스템을 사용하였고, Nd-Yag Laser를 이용하여 분무특성을 가시화하였다. 실험결과, 분무오리피스의 직경이 커질수록 분무입자의 크기가 작아졌으며, 분무 오리피스의 직경이 2.6mm인 경우 최적의 분무형태를 보였다. 그러나 오리피스의 직경이 이보다 클 경우 분무입자의 크기는 더 이상 감소하지 않았다. 이것은 분무오리피스가 최적의 직경보다 커질 경우 오리피스내의 액막이 균일하게 분포하지 않기 때문으로 판단된다.

  • PDF

액상 충돌 제트의 혼합에 대한 분사공 직경비의 영향 (Effect of Orifice Diameter Ratio on Unlike Impinging Jet Mixing)

  • 이성웅;조용호;유병일
    • 한국분무공학회지
    • /
    • 제11권4호
    • /
    • pp.220-227
    • /
    • 2006
  • Experimental studies has been conducted to investigate the effect of orifice diameter ratio on the mixing characteristics of the split element of doublet and triplet elements. The spray characteristics of non-reacting immiscible liquids have been investigated using a patternator. The local volume fraction is measured by use of mean value of each component. This volume measurement represents the mixing characteristics of the liquid, which affect the overall combustion efficiency. The ratio of the orifice diameter, ranging from 1 to 1.5, and that of the jet-momentum, ranging from 0.5 to 6.0, we used. The jet impinging behavior with use of various ratios exhibits substantially different mixing characteristics. Mixing efficiency is maximized when the jet-momentum ratio is increased; this behavior is particularly prominent when the orifice diameter ratio is greater than unity. The split of the triplet element yields better mixing characteristics and is more effective than that of the doublet element in regard to achieving high combustion efficiency. The optimum mixing factor for the triplet element is found to be 0.75, according to our measurement.

  • PDF