• 제목/요약/키워드: organic vapors

검색결과 53건 처리시간 0.022초

공기중 유기용제 농도 측정에 있어서 수동식 시료채취기의 성능평가 및 한국산 수동식 시료채취기의 개발에 관한 연구 제 1 부 : 외국산 수동식 시료채취기의 성능 평가 (Evaluation of Commercially Available Passive Samplers and Development of New Passive Samplers Part 1: Evaluation of Commercially Available Passive Samplers)

  • 백남원;박미진;윤충식
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.109-124
    • /
    • 1996
  • This study was performed to evaluate the performance of three passive samplers made in U.S.A. Three passive samplers selected for this study included products made by 3M, Gilian, and SKC in U.S.A. Three organic solvents, such as toluene, trichloroethylene, and n-hexane which are used frequently in Korean industry were selected for the study. Conclusions obtained from this study are summarized as follows. 1. For toluene and trichloroethylene, the overall accuracy of the results from all of three products was within 25 %, which is the criteria recommended by the U.S. National Institute for Occupational Safety and Health (NIOSH). For n-hexane, the overall accuracy of the results from two products except 3M was exceeding 25 %. Thus 3M product showed the best accuracy among three products. 2. When passive samplers collected organic vapors were exposed to clean air for two hours, there were 12 - 16 % loss of organic vapors due to reverse diffusion in Gilian products. There was no significant loss in results from other two products. 3. Air velocity affected greatly on the performance of passive samplers which did not have permeation membrane. At high velocity, 100 cm/sec, accuracies of results from Gilian and SKC were 57 - 108 and 128 - 164 %, respectively. However, the results from 3M samplers, which contain permeation membrane, indicated accuracy below 25 %. 4. When passive samplers collected organic vapors for eight hours, the accuracy was reduced. Thus, it is recommended that passive samplers be used for less than four hours.

  • PDF

서울 동부지역내 작업장 공기질에 관한 조사 연구 (A Study of Workplace Air Quality in the Eastern Seoul)

  • 임창훈;황인조;김동술;김윤신
    • 한국대기환경학회지
    • /
    • 제15권3호
    • /
    • pp.235-247
    • /
    • 1999
  • This study was performed to investigate what was the most serious occupational factors in small scale industries. Twenty-three occupatonally hazardous substances were measured at the five workplaces in the Eastern Seoul during 1995∼1996. Total of 2,020 samples were analyzed by either GC/FID for organic vapors or AAS for heavy metals. From the results of this study noise was the most serious factor at the selected workplaces. Noise level in the metal processing, the printing, and the auto repairing industries exceeded the 8 hr PEL by 19.7%, 13.6%, and 11.6%, respectively. Mean concentrations of toluene in the shoe making and the printing industries exceeded the assessment crieterion by 6.0% and 3.8%, respectively. Further study of risk assessment of occupational exposure may be required to protect workers from hazardous working conditons.

  • PDF

Yoon과 Nelson의 흡착모델을 이용한 방독마스크 정화통의 수명예측(I) (Prediction of Service Life of a Respirator Cartridge for Organic Solvent by Using Yoon and Nelson's Adsorption Model)

  • 김기환;원정일
    • 한국산업보건학회지
    • /
    • 제18권1호
    • /
    • pp.20-31
    • /
    • 2008
  • A respirator is useful to protect a worker from the harmful gases and vapors in the workplace, and the evaluation of respirator cartridge service life is important for the worker's health and safety. The performance of cartridge is effected by several factors such as concentration of gas and vapor, humidity, temperature, adsorbents and cartridge packing density. Adsorption model was applied to both sampling tube and respirator cartridge to predict the service life for organic vapors. The variables of the adsorption model were measured from the experiment with the sampling tube, and it was used to predict the service life of respirator cartridge. In the experiment, we used carbon tetrachloride as a organic vapor and activated carbon take out respirator cartridge as activated carbon. As a result, it was possible to predict the service life of respirator cartridge and predicted service life was quite correct. Breakthrough time decreased with increase of CCl4 concentration. In case of sampling tube, adsorbed amount of CCl4 was larger than respirator cartridge due to linear velocity. Also, rate constant of sampling tube was larger than respirator cartridge, because of, effect of flow rate, packing density. In the prediction of service life of respirator cartridge by using sampling tube, the time required for 50% contaminant breakthrough(${\tau}$) is more effective than the rate constant(k').

혼합 유기용제 포집시 습도가 활성탄관의 파과에 미치는 영향 (Effect of Relative Humidity on the Breakthrough of Charcoal Tubes during Mixed Organic Vapor Sampling)

  • 양혁승;김현욱
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.125-137
    • /
    • 1996
  • This study was designed to investigate effects of relative humidity on the breakthrough of charcoal tubes at a fixed vapor concentration and sampling time during mixed organic vapor sampling. A vapor generator was used to generate three different concentrations of mixed organic vapor and a stainless steel chamber was fabricated and utilized to maintain three different percentages of relative humidity while maintaining a constant temperature. The results were as follows; 1. At high relative humidity, breakthrough of mixed organic vapor occurred quickly at low vapor concentration than at high vapor concentration because of the reduced adsorption volume of charcoal tube due to humidity. 2. Breakthrough by competitive adsorption of vapors onto charcoal tube was observed at first from n-hexane having the lowest boiling point and highest vapor pressure among the three organic vapors investigated, followed by TCE. No breakthrough was observed from toluene under all experimental conditions. 3. For n-hexane, breakthrough was observed after 2 hours of sampling and breakthrough rates were increased as relative humidity increased. For TCE, breakthrough was found after 3 hours of sampling and breakthrough rates by sampling time were increased as vapor concentration increased. 4. The adsorbed amount of mixed organic vapor at breakthrough was shown to have statistically significant correlations with sampling time, relative humidity, and vapor concentration in descending order of correlation. Relative humidity and sampling time for n-hexane and sampling time and concentration for TCE were both statistically significantly correlated. 5. Relative humidity was found to affect the amount of breakthrough of mixed organic vapor and n-hexane. Among three percentages of relative humidity investigated, the amount of breakthrough at 85 % relative humidity was significantly larger than those of at lower percentages of relative humidity. No statistically significant difference was found between 25 % and 55 % relative humidity. 6. The results of multiple regression analysis between breakthrough and relative humidity, vapor concentrations showed that the coefficient of determination of mixed organic vapor was 0.263 and those of n-hexane and TCE were 0.275 and 0.189, respectively. 7. Flow rates of sampling pumps used were found to be affected by relative humidity present. At 25 %, 55 %, and 85 % relative humidity, the relative errors of sampling pump were 1.4 %, 13.4 %, and 18.6 %, respectively. In conclusion, the results of this study showed that high relative humidity could reduce the adsorption volume of charcoal tubes and subsequently increase breakthrough rates. Therefore, to prevent breakthrough when sampling mixed organic vapors, it is suggested that either sampling volume be reduced on the flow rate be lowered so as to minimize breakthrough of the most volatile organic vapor in the mixture. In addition, since the flow rates of a sampling pump can be adversely affected by high relative humidity, it is recommended to use a constant flow mode pump when sampling in the highly humid environment.

  • PDF

표면 기능성을 가진 다공성 실리콘의 Fabry-Perot fringe pattern의 변화를 이용한 유기 화합물의 감지 (Detection of Organic Vapors Using Change of Fabry-Perot Fringe Pattern of Surface Functionalized Porous Silicon)

  • 황민우;조성동
    • 통합자연과학논문집
    • /
    • 제3권3호
    • /
    • pp.168-173
    • /
    • 2010
  • Novel porous silicon chip exhibiting dual optical properties, both Frbry-Perot fringe (optical reflectivity) and photoluminescence had been developed and used as chemical sensors. Porous silicon samples were prepared by an electrochemical etch of p-type sillicon wafer (boron-doped, <100> orientation, resistivity 1 - 10 ${\Omega}$). The ething solution was prepared by adding an equal volume of pure ethanol to an aqueous solution of HF (48% by weight). The porous silicon was illuminated with a 300 W tungsten lamp for the duration of etch. Ething was carried out as a two-electrode Kithley 2420 preocedure at an anodic current. The surface of porous silicon was characterized by FT-IR instrument. The porosity of samples was about 80%. Three different types of porous silicon, fresh porous silicon (Si-H termianated), oxidized porous silicon (Si-OH terminated), and surface-derivatized porous silicon (Si-R terminated), were prepared by the thermal oxidation and hydrosilylation. Then the samples were exposed to the wapor of various organics vapors. such as chloroform, hexane, methanol, benzene, isopropanol, and toluene. Both reflectivity and photoluminescence were simultaneously measured under the exposure of organic wapors.

휘발성유기화합물가스에 대한 폴리아닐린 센서의 감도 향상 (Sensitivity Enhancement of Polyaniline Sensor to Volatile Organic Compounds)

  • 유준부;유비;임정옥;변형기;허증수
    • 한국재료학회지
    • /
    • 제17권8호
    • /
    • pp.433-436
    • /
    • 2007
  • Nano-structured polyaniline have been synthesized by interfacial polymerization method at room temperature. An aqueous solution of aniline in chloroform and another solution of ammonium peroxydisulfate in doping acid were prepared at different times terminated with methanol at room temperature. SEM, UV-vis were used to characterize the polyaniline with regard to their morphology and structure. The diameter and length of polyaniline can be controlled by the reaction time. Nano-structured polyaniline were found to have superior sensitivity for volatile organic compounds(VOCs). As the reaction time to increase from 30minute to 2hours the sensitivity were decreased to VOCs vapors. The sensitivity of Nano-structured polyaniline sensor appeared to VOCs better than the sensitivity of chemical synthesis sensors. The sensitivity of Nano-structured polyaniline sensor improved benzene vapors.

Hexamethyldisiioxane의 플라즈마 중합에 의하여 제조된 복합막을 통한 공기중의 휘발성 유기물질의 분리에 관한 연구 (Separation of VOCs from Air through Composite Membranes Prepared by Plasma Polymerization of Hexamethyldisiioxane)

  • 류동현;오세중;손우익;구자경
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 추계 총회 및 학술발표회
    • /
    • pp.63-65
    • /
    • 1998
  • 1. Introduction : Atmospheric discharge of VOC-contaminated streams in chemical plants and air streams from chemical processes poses a serious environmental problem and entails large financial losses. Such emissions may be reduced by i) adsorption process, ii) absorption process and iii) incineration process. These processes only forbids the air pollutions. Throughout the recent decade, another technique-membrane process has emerged. The separation and recovery of organic vapors by membrane process may have great economic potential. Most of the published research works on the separation of organic vapors from air were performed using silicon rubber membranes. However, it is very difficult to fabricate very thin membranes with less than 1 $u m thickness. Plasma polymerization could be a good technique to generate a thin polymer film. The objective of this work is to find out the optimum condition of plasma polymerization for producing VOC separation membrane. For the objective, composite membranes are prepared through plasma polymerization of hexamethyldisiloxane onto porous substrates under different conditions. The membrane is then subjected to the permeation of permanent gases and VOCs to find the correlations between the physical properties of the penetrant and permeability and selectivity.

  • PDF

중소규모 화학공장의 압력방출시스템에 대한 안전성 검토 (Review of Safety for Pressure-Relieving Systems of Small to Middle Scale Chemical Plants)

  • 임지표;진대영;마병철;강성주;정창복
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.48-55
    • /
    • 2015
  • A variety of safety issues were investigated for chemical reactors using a toluene solvent in case of a fire at small to middle scale chemical plants. The issues covered the operation of pressure-relieving valves and the subsequent discharges of the toluene to the atmosphere either directly or through an absorber, which represent the current practice at most small chemical plants. It was shown that the safety valve on the reactor may not operate within about twenty minutes after an external fire breaks out, but, once relieved, the toluene vapor released directly to the atmosphere may form a large explosion range on the ground. It was also shown that if the discharge is routed to an existing absorber used for the scrubbing of volatile organic compounds or dusts, the column may not operate normally due to excessive pressure drops or flooding, resulting in the hazardous release of toluene vapors. This study proposed two ways of alleviating these risks. The first is to ruduce the discharge itself from the safety valve by using adequate insulation and protection covers on the reactor and then introduce it into the circulation water at the bottom of the absorber through a dip linet pipe equipped with a ring-shaped sparger. This will enhance the condensation of toluene vapors with the reduced effluent vapors treated in the packing layers above. The second is to install a separate quench drum to condense the routed toluene vapors more effectively than the existing absorber.

DEVELOPMENT OF MEMBRANE AND COLD-CONDENSATION PROCESS FOR REMOVAL AND RECOVERY OF VOLATILE ORGANIC COMPOUNDS

  • Kim, Sung-Soo;Lee, Jong-Hwa;Kim, Hyunki;Kim, Sang-Yong
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 The 4th Korea-Italy Workshop
    • /
    • pp.69-72
    • /
    • 2003
  • Volatile organic compounds (VOC) cause air pollution problem and deterioration of atmosphere of petrochemical and fine chemical plants. Hybrid process of membrane and cold-condensation were developed and it effectively removed and recycled the VOC. Operation parameters of the process were optimized to attain hish removal and recycle of VOC. Composite membranes for organic vapor separation were developed in this work by PDMS coating and plasma polymerization on polypropylene and polysulfone support membranes. PDMS and various silicone monomers were tested for several organic vapors such as benzene, toluene, TCE, and HCFC, which are produced in petrochemical and fine chemical industry and causes air pollution problems if are released to atmosphere. Composite membranes prepared in this work showed appreciable performance in terms of organic vapor removal and reuse. Performance variation of the membranes was correlated with their surface characteristics.

  • PDF

유기 가스 검지를 위한 다공질 실리콘층의 전기 저항 의존성 (Dependence of Electrical Resistance in Porous Silicon Layer for Detecting Organic Vapors)

  • 박광열;김성진;이상훈;최복길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.792-796
    • /
    • 2002
  • In this work, porous silicon(PS) layer is used as a sensing material to detect organic gases. To do this, PS sensors with membrane structure are fabricated. The sensors were made by applying the technologies of membrane formation by anisotropic etching of silicon, and PS layer formation by anodization in HF solution. From fabricated sensors, current-voltage (I-V) curves were measured against ethanol (called alcohol), methanol and acetone gases evaporated from 0.1 to 0.5% solution concentrations at $36^{\circ}C$. As the result, all curves showed rectifying behavior due to a diode structure between Si and PS, and the conductance of sensor devices increased largely with the organic solution concentration at high voltage of 5V.

  • PDF