• Title/Summary/Keyword: organic sludge

Search Result 848, Processing Time 0.024 seconds

Application of Anaerobic Membrane-Fermenter for the Recovery of Volatile Fatty Acids from Organic Liquid Sludge (유기성 액상 슬러지로부터 휘발성 지방산의 회수를 위한 혐기성 막-발효기의 적용)

  • 김종오;정종태
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.37-43
    • /
    • 2004
  • As the experimental results of membrane application for the production and recovery of volatile fatty acids, suspended solids concentration, the number of acid producing bacteria and organic acid concentration increased with membrane coupling in the fermenter. The application of membrane for the efficiency increase of solid-liquid separation and fermentation made the number of acid producing bacteria increase in the fermenter, thus acid forming rate showed higher value than that of membrane-free fermenter. Membrane-coupled fermenter was believed to be an effective technology for the improvement of recovery efficiency of volatile fatty acids from organic sludge.

Effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) Process on Removal of the Organic Matters in Ammonia Stripped Swine Wastewater (ASBR(Anaerobic Sequencing Batch Reactor) 공정의 F/R비가 암모니아가 탈기된 축산폐수의 유기물 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.6
    • /
    • pp.687-694
    • /
    • 2005
  • Lab-scale experiments have been carried out to investigate the effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) process on the removal of the organic matters in ammonia stripped swine wastewater. Three ASBR inoculated with sludge mixed with granular sludge of UASB (Upflow Anaerobic Sludge Blanket) and anaerobic digested sludge of municipal wastewater treatment plant were operated. Ammonia stripped swine wastewater was used as influent. Prior to conducting the experiments with varied conditions, the effect of increasing organic loading rate from 2.34 to $5.79gTCOD_{Cr}/L$-day at a fixed F/R ratio of 0.1 on the organic removal efficiency has been studied during start-up period. As the result of the experiment, under the condition of varied organic loadings, less than $4.14gTCOD_{Cr}/L$-day, the removed efficiency $TCOD_{Cr}$ of the ASBR process is 83% resulted from the mean value of effluent $TCOD_{Cr}$, 9,125 mg/L during the start-up period. Then ASBRs were operated with F/R ratio of 0.024, 0.303 and 0.91 respectively. Organic loading rate was increased from 4.56 to $15.43gTCOD_{Cr}/L$-day to investigate the effects of F/R ratio and organic loading rate on the organic removal efficiency. As the result of the experiment, less than $6.23gTCOD_{Cr}/L$/L-day, F/R ratio haven't an effect on the organic removal efficiency and the mean removal efficiency of TSS, $TCOD_{Cr}$ and $SCOD_{Cr}$ was about 80%, 86% and 78% at the all of F/R ratio. But as organic loading rate was increased from 8.54 to $12.04gTCOD_{Cr}/L$-day at the F/R ratio of 0.024, the removal efficiency of $SCOD_{Cr}$ decreased from 71% to 63%. The range of decreased removal efficiency of $SCOD_{Cr}$ at the F/R ratio of 0.024 was much more higher than at the F/R ratio of 0.303, 0.91. Thus, as organic loading rate was increased, ASBRs were operated with high F/R ratio to obtain high removal efficiency.

The Charncteristics of Organic Sludge in Curing Equipment (유기성 슬러지 양생장치의 건조특성)

  • Jung, Ho-Yun;Park, Jae-Sung;Kang, Jin-Soo;Yun, Hee-Chul;Lee, Yeon-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3173-3177
    • /
    • 2007
  • Recently, we have many problems on the process of the sludge. In past, the sewage sludge was treated by reclaimed land or thrown away in the sea. But these methods caused environmental pollution. Today, many researchers are studying various methods for reducing its volume. One of these method, this study is to reduce the moisture of sewage sludge and to solidify it using a dryer and curing equipment. In this research, we investigated about design parameter and operation condition of the equipment. The curing equipment reduces the percentage of water content from 30% of dryer to 10%. So, we have to study the curing characteristics and performance of curing equipment. For example, there are internal flow characteristics and change of the percentage of water content. And we investigated the change of data at outlet along the initial condition, temperature, humidity and air flow. Using this data, we achieve the experimental results of curing efficiency by each geometry and operating condition. And we also investigated numerical analysis of internal flow using CFD code. This research is basic study for optimal design of the curing equipment.

  • PDF

Sludge Returned CMAS에 의한 전기부속품제조공장 폐수처리

  • 김남천;이시진
    • Microbiology and Biotechnology Letters
    • /
    • v.25 no.4
    • /
    • pp.427-433
    • /
    • 1997
  • Sludge Returned CMAS process was applied to treat the wastewater from electric accessory manufacturing company while this type of wastewater was usually treated by chemical process. This result show that the removal rate of TCOD was about 70-80% regardless of hydraulic retention time, On the contrary, the removal rate of BOD was abtained in a range of 77-92% depending on hydraulic retention time. In order to remove more than 80% of organic materials with the proposed process, the F/M ratio should be maintained below 0.17. In this case, the calculated value of organic removal rate, Km, was calculated to be 1.26 hr$^{-1}$, and the ratio of cell synthesis/total energy was 0.32 and 0.26 for COD and BOD base, respectively. The yield coefficient was calculated to be 0.242 and the half velocity coefficient was 0.3 hr$^{-1}$. The value of endogenous respiration coefficient was 0.02 hr$^{-1}$. The measured effluent BOD concentration, MLSS concentration in aeration tank, oxygen uptake rate, and sludge production were matched relatively well with the calculated values using above coefficients, In order to optimize the dewatering of sludge, the hydraulic retention time was recommended to be 15. 6 hrs. These results indicate that the wastewater from an eletric accessory manufacturing company can be treated safely with a biological process.

  • PDF

Bioremediation of Phenolic Compounds Having Endocrine-disrupting Activity Using Ozone Oxidation and Activated Sludge Treatment

  • Nakamura, Yoshitoshi;Daidai, Masakazu;Kobayashi, Fumihisa
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.3
    • /
    • pp.151-155
    • /
    • 2004
  • The bioremediation of water system contaminated with phenolic compounds having endocrine-disrupting activity, i.e. 2,4-dichlorophenol, 2,4-dichlorophenoxy acetic acid (2,4-D), and 2,4,5-trichlorophenoxy acetic acid (2,4,5-T), was investigated by using ozone oxidation and activated sludge treatment. Ozone oxidation (ozonation time: 30 min) followed by activated sludge treatment (incubation time: 5 days) was an efficient treatment method for the conversion of phenolic compounds in water into carbon dioxide and decreased the value of total organic carbon (TOC) up to about 10% of initial value. Furthermore, 2,4-D was dissolved in water containing salt, i.e. artificial seawater (ASW), and this water was used as model coastal water contaminated with phenolic compounds. The activated sludge treatment (incubation time: 5 days) could consume significantly organic acids produced from 2,4-D in the model costal water by the ozone oxidation (ozonation time: 30min) and decrease the value of TOC up to about 35% of initial value.

Contemporary organic contamination levels in digested sewage sludge from treatment plants in Korea: (2) Non-alkylated Polycyclic Aromatic Hydrocarbons (우리나라 하수 및 폐수 처리 슬러지의 다환방향족탄화수소의 함량)

  • Lee Kang-Young;Chung Chang-Soo;Kim Young-Il;Lee Hyun-Kyung;Hong Gi-Hoon
    • Journal of Environmental Science International
    • /
    • v.14 no.4
    • /
    • pp.413-425
    • /
    • 2005
  • The 16 priority PAHs (Polycyclic Aromatic Hydrocarbons) designated by US Environmental Protection Agency were analyzed for some digested sludges from wastewater treatment plants in Korea. PAHs are an important group of organic contaminants present in sewage sludge due to their persistence and toxic potential. PAHs were extracted from freeze-dried sludges using a methylene chloride-methanol (2:1) mixture in a soxhlet extractor. The extracts were cleaned-up by silica gel/alumina combination column and subsequently fed into gas chromatograph/mass spectrometer (GC/MS) for determining PAH contents. The sum of the 16 PAHs in the sewage sludge varied from 534.8 to $5754.5 {\cal}ug/{\cal}kg$, dry wt.. In the sewage sludge, phenanthrene appears as the most abundant PAHs, followed by naphthalene, pyrene, fluoranthene. Source of the investigated sewage sludges relatively predominated pyrogenic. PAHs levels of sewage sludges in Korea appeared to be lower than those in other countries.

Performances of Anaerobic Sequencing Batch Reactor for Digestion of Municipal Sludge at the Conditions of Critical Solid-liquid Separation (혐기성 연속 회분식 공정에 의한 도시하수슬러지 소화시 고액분리 특성에 따른 처리효율평가)

  • Hur, Joon-Moo;Park, Jong-An
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.5
    • /
    • pp.77-85
    • /
    • 2002
  • The objective of this study was to evaluate the performances of the ASBR under critical conditions of solid-liquid separation, caused by extremely high solids concentration, for wider application of the ASBR to various wastes. The ASBRs and completely-mixed daily-fed control runs were operated using a municipal mixed sludge at 35$^{\circ}C$ and 55$^{\circ}C$. Conversion of completely-mixed daily-fed reactor to sequencing batch mode and changes in HRT of all ASBRs were easily achieved without adverse effect, regardless of digestion temperature. Solids accumulation was remarkable in the ASBRs, and directly affected by settleable solids concentration of the feed sludge. Noticeable difference in solids-liquid separation was that flotation thickening occurred in the mesophilic ASBRs, while gravity thickening was a predominant solid-liquid separation process in the thermophilic ASBRS. Solids profiles at the end of thickening step dramatically changed at solid-liquid interface, and slight difference in solids concentrations was observed within thickened sludge bed. Organics removals based on subnatant or supernatant after thickening always exceeded 80% in all reactors. Thickened sludge volume and gas production of the ASBRs affected mutually. Gas production increased as thickened sludge accumulated, and continuous gas evolution during thickening could cause thickened sludge to expand or resuspend. Thickened sludge volume exceeding a predetermined withdrawal level resulted in loss of organic solids as well as biomass during withdrawal step, leading to decrease in gas production ind SRT. Such an adverse mutual effect was significant in gravity thickening, while it was not sensitive in flotation thickening. Changes in organic loading had no significant effect on organic removals and gas production after build-up of solids in the ASBRs.

Effect of the Addition of Granular Activated Carbon and Granular Sludge on the Performance of Upflow Anaerobic Sludge Blanket Reactors for Treating Leachate (상향류 혐기성 슬러지 블랭킷 반응조를 이용한 침출수 처리시 입상 활성탄 및 입상슬러지 첨가의 영향)

  • Lee, Chae-Young
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.4
    • /
    • pp.91-97
    • /
    • 2008
  • The objective of this research is to investigate the effect of the addition of granular activated carbon (GAC) and granular sludge on the performance of upflow anaerobic sludge blanket (UASB) reactors for treating leachate. For the control reactor, sludge obtained from an anaerobic digester was used as a seed material. On the other hand, GAC and granular sludge were incorporated with the seed sludge in the GAC reactor and the Granule reactor, respectively. The shortest acclimation period was observed in the Granule reactor. The GAC reactor also gave comparable performance to the Granule reactor at the beginning of operation. However, as the adsorptive capacity of GAC was exhausted, the effluent COD concentration increased gradually. Once the systems were stabilized, the GAC reactor showed slightly better results than the other two reactors in terms of chemical oxygen demand (COD) removal. COD removal in all reactors was more than 90% at hydraulic retention time of 1.0 day. Furthermore, GAC reactor showed little variation in COD removal rate and remained at 95% with organic loading rate (OLR) of 4.0 to $8.2kg\;COD/m^3.d$. Initial operating period was reduced by the addition of granular sludge, while the treatment efficiency was enhanced by the addition of GAC.

  • PDF

Evaluation of Performance and Economical Efficiency of the Advanced Wastewater Treatment System (고도(高度) 하수처리(下水處理) 시스템의 처리성능 및 경제성 평가에 관한 연구)

  • Kim, Dong Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.61-71
    • /
    • 1999
  • For a high-rate fermentation and recovery of organic acid, we have developed a new organic acid fermentation reactor with membrane filter, which is the most important part in the new advanced wastewater treatment system. The recovered organic acid is to be reused as an organic carbon source at denitrification process. Some experiments were conducted to compare the performance of acid fermentation at different SRTs, such as 5, 10, and 20 days. The total organic acid concentration produced during the runs was in the range of 2,100-2,900 (mgC/L). The conversion efficiency from substrate to organic acid reached to from 43% to 59%. The recovery rate of organic acid from substrate based on TOC was from 26% to 53%. Regardless of operational conditions, it has been able to maintain the membrane flux constantly, in the range of 0.4-0.46 ($m^3/m^2/day$). The transmembrane pressure drop was 0.2-0.3 (kg/cm) for 100 day's operation. The result of simulation is as follows. Organic removal efficiency of the new advanced treatment system is 95%. 73% of Nitrogen is removed. The removal efficiency of Phosphorus is 93%. By coqulation, soluble phosphorus is able to remove from the water treatment lines, which is impossible at conventional activated sludge system. The unit construction cost is 65000 (yen/m3) and it was 1.4 times than that of the standard activated sludge system. The unit operation cast is 7.7 ($yen/m^3/day$) and it was 1.3 times than that of the standard activated sludge system.

  • PDF

Acclimation of magnetic activated sludge with 1,4-dioxane and analysis of bacterial flora in the sludge

  • Toshiyuki Nikata;Hayato Ogihara;Yasuzo Sakai
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.3
    • /
    • pp.7-12
    • /
    • 2023
  • Isolation of pollutant-degrading bacteria is important in bioaugmentation, one of the methods for biological degradation of environmental contaminants. We focused on the magnetic activated sludge (MAS) process as a culture method that efficiently concentrates degrading bacteria, and cultured activated sludge with 1,4-dioxane as a model pollutant. After 860 days of operation, MLVSS, which indicates the amount of sludge, increased from 390 mg/L to 10,000 mg/L, and the removal rate of organic matter including 1,4-dioxane, tetrahydrofuran, and glucose in the artificial wastewater reached up to 97%. Based on these results, the MAS process was successfully used to acclimate activated sludge with 1,4-dioxane. Bacterial flora analysis in the MAS showed that bacteria of the genus Pseudonocardia, already reported as 1,4-dioxane degrading bacteria, play an important role in the degradation of this pollutant. The MAS process is a suitable culture method for acclimation of environmental pollutants, and the findings indicate that it can be used as an enrichment unit for pollutant-degrading bacteria.