• Title/Summary/Keyword: organ distribution

Search Result 256, Processing Time 0.026 seconds

The Treatise Research on Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) (화타협척혈에 대한 문헌적 고찰)

  • Ahn, Soo-Gi;Lee, Sam-Ro;Yang, You-Sun
    • Journal of Acupuncture Research
    • /
    • v.17 no.4
    • /
    • pp.139-148
    • /
    • 2000
  • Objectives : Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) is the Jing-Wai-Qi-Xue(經外奇穴) that is widely used in clinic and effective in Acupuncture and Moxibustion. But the location, number, acupuncture method, clinical application of Hua-Tuo-Jia-Ji-Xue have not been explained clearly and consistently; moreover, studies or clinical reports about this are insufficient. The purpose of this study is to investigate the location, number, acupuncture method, clinical apptication of Hua-Tuo-Jia-Ji-Xue. Methods : We investigated Hua-Tuo-Jia-Ji-Xue through survey of 11 books and 26 relevant journals published in China Results : 1. Hua-Tuo-Jia-Ji-Xue is located in about 0.5 Cun(寸) at both sides of spinous process of each vertebra. 2. There is differ as the number of Hua-Tuo-Jia-Ji-Xue is 34, 48, 56, 58 in each documents. Hua-Tuo-Jia-Ji-Xue located in first, second cervical vertebra and first sacrum is low in application frequency, Hua-Tuo-Jia-Ji-Xue located from third cervical vertebra to fourth lumbar vertebra is high in apptication frequency. Therefore, all of the acupoints located in about 0.5 Cun(寸) both sides of spinous process of cervical, thoracic, lumbar and sacral vertebrae are regarded as Hua-Tuo-Jia-Ji-Xue in wide meaning. 3. There are Kou-Ci-Fa(叩刺法), Qian-Ci-Fa(淺刺法), Yan-Pi-Ci-Fa(沿皮刺法), Shen-Ci-Fa(深刺法) in acupuncture method of Hua-Tuo-Jia-Ji-Xue. Acupuncturing depths, directions is differ in each location(cervical, thoracic, lumbar vertebra, sacrum) and have something to do with therapeutic effect of Hua-Tuo-Jia-Ji-Xue. The feeling that patient receive after acupuncture is the key to the treatment of disease. 4. The clinical application of each Hua-Tuo-Jia-Ji-Xue is mainly selected by distribution of meridians, nerve roots, vertebral segments which are attacked with a disease. The musculoskeletal diseases in treatment of disease by Hua-Tuo-Jia-Ji-Xue are the most common as 12 cases. Second, there are many reports about nervous system diseases. In addition, good therapeutic results by application of Hua-Tuo-Jia-Ji-Xue are reported in some diseases, for instance, diseases of five viscera and six entrails, organ, tissue Conclusions : Hua-Tuo-Jia-Ji-Xue is located in about 0.5 Cun(寸) at both sides of spinous process of each cervical, thoracic lumbar and sacral vertebra. Therapeutic effect of Hua-Tuo-Jia-Ji-Xue has something to do with acupuncturing depths, directions and feelings. Hua-Tuo-Jia-Ji-Xue is mainly selected by distribution of meridians, nerve roots, vertebral segments which are attacked with a disease and is mainly applied musculoskeletal diseases, nervous system diseases.

  • PDF

Studies on the Preparation of $^{99m}TC$ Labelled Antimony Sulfide Colloid and Hydroxyethyl Starch for Lymphoscintigraphy (림포신티그래피용 $^{99m}TC$를 표지황화안티몬 콜로이드 및 전분의 제조에 관한 연구)

  • Park, Kyung-Bae;Awh, Ok-Doo;Kim, Jae-Rok;Lim, Sang-Moo;Hong, Seong-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.71-83
    • /
    • 1989
  • For the development of $^{99m}Tc-labelled$ antimony sulfide colloid and hydroxyethyl starch, various experiments such as preparation of colloid, control of the distribution of particle size, establishment of labelling conditions, determination of labelling yield and radiochemical purity, examination of stability, and organ imagings of rabbits etc. were carried out. 1) Antimony sulfide colloid was readily prepared by the reaction of aqueous solution of antimony potassium tartrate with hydrogen sulfide generated by treating ferrous sulfide with dilute sulfuric acid. The colloid could be stabilized by adding small amount of polyvinylpyrrolidone. 2) Electron microscopy analysis exhibited the distribution of colloid size in the range of $1\sim15nm$ with a major portion of 9 m. The colloid solution was sterilized by membrane filtration $(0.2{\mu}m)$ and then stored at $4^{\circ}C$. This sterilized colloid was so stable that it was usable at least for one year. 3) The antimony sulfide colloid was labelled by adding sodium $pertechnetate-^{99m}Tc$ solution to the reaction vial, followed by adding hydrochloric acid and then boiled for 30 min. The optimal pH of the reaction mixture was found to be in the range of $1.3\sim1.4$. Instant thin layer chromatography (ITLC) analysis showed high labelling yield of above 99.5%. This labelled colloid maintained high radio-chemical purity of above 99% until 10 hours after labelling. 4) Animal studies showed high uptake of $^{99m}Tc-Sb_2S_3$ colloid at lymph vessels and nodes indicating a suitable agent for lymphoscintigraphy. Satisfactory results were also abtained in other clinical studies. 5) Hydroxyethyl starch (HES $0.6\sim1.0%$) was labelled with $Na^{99m}TcO_4$ in the presence of $SnCl_2$ with high labelling yield of above 99.5%. The optimal pH of the reaction mixture was in the range of $1.8\sim2.0$. $^{99m}Tc-HES$ maintained high radiochemical purity of above 99% until 10 hours after labelling. 6) Animal studies showed that $^{99m}Tc-HES$ migrated more rapidly from the injection sites into the lymph vessels than $^{99m}Tc-Sb_2S_3$ colloid while less amount of the former was uptaken at lymph nodes than that of the latter. Similar phenomenon was also observed in other clinical studies. As a result, $^{99m}Tc-Sb_2S_3$ colloid was found to be more effective lymphoscintigraphic agent than $^{99m}Tc-HES$.

  • PDF

Treatment planning of Lung Cancer with Density corrected Computed Tomography (밀도를 입력한 CT planning을 이용한 Lung Cancer의 치료계획)

  • 김성규;김명세;신세원;홍정숙
    • Progress in Medical Physics
    • /
    • v.4 no.2
    • /
    • pp.19-25
    • /
    • 1993
  • Treatment planning of lung cancer with density corrected Computed tomography. Eighty-seven patients with lung cnacer who had radiation therapy in Yeungnam University Medical Center between, April 1 1990 and Aug. 30 1993 were retrospectively evaluated total tumor dose, dose distribution, field correction, and loading change, compared with contour or CT image planning and density corrected CT planning. In dose distribution, higher dose was calculated in compare with density corrected CT planning less than 5% difference were found in 45 patient(52%), 5-10% in 25 patients (29%), 10-15% in 15 patients (17%) and over 15% in 2 patients (2%). Correction of treatment field was performed in 18 patients (21%) and changing of dose loading was given in 15 patients (17%). In conclusion, we emphasize that density corrected CT planning is the very important factor which contribute to increase therapeutic gain by exact selection of target volume, target dose, normal tissue dose and dose of critical organ.

  • PDF

Worker Health Hazard and Risk Assessment of Formamide using in Workplaces in South Korea (작업장에서 사용하는 포름아미드(Formamide)의 근로자 건강 유해성과 위험성 평가)

  • Kim, Hyeon-Yeong
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.35-42
    • /
    • 2016
  • Formamide is a colorless fluid with ammonia odor, and irritable when inhaled. It has $LD_{50}$ value of > 5,577 mg/kg in rats for acute oral toxicity and NOAEL of 113 mg/kg/day for target organ (liver) of whole body toxicity. It is also known as reproductive toxicant (1B) and TWA(Time Weighted Average) for it is 10 ppm. Workplace measurements of work places dealing with formamide showed the ppm of all 25 samples was very lower than WEL. However, the exposure concentration can change, depending on workplace condition such as the intensity of work, operating local ventilation system, and wearing protection equipment (Respirators). Therefore, considering it with the risk of whole body toxicity and reproductive toxicity, exposure quantity of each imaginary scenario was calculated at 5.16, 1.72, and $0.43mg/m^3$. The average value was calculated at 0.02-0.58, 0.02-0.66 at 90 percent of cumulative distribution, 0.02-0.69 at 95 percent of cumulative distribution. Therefore, it was generally evaluated to be safe because all values were below 1. However, caution is required to prevent health hazard because it has hepatotoxicity and reproductive toxicity and risk of a high level momentary exposure, depending on the condition of workplace.

Ureide Distribution in Nitrogen Fixing Soybean Plant under External Phosphorus Limitation (인산결핍 조건하에서 질소고정식물체내의 Ureide 분배)

  • Sa, Tong-Min
    • Applied Biological Chemistry
    • /
    • v.40 no.3
    • /
    • pp.232-237
    • /
    • 1997
  • Soybean plants inoculated Bradrhizobium japonicum MN 110 were grown in outdoor perlite pots with nitrogen free nutrient solution containing 1.0 mM-P(control) and 0.05 mM-P(stress) and harvested at 28, 35, 42 and 49 days after transplanting (DAT) to examine the effect of phosphorus deficiency on ureide concentration of and distribution to diffrent plant organ in nitrogen fixing soybean plant during the vegetative growth. Total dry mass of control plants increased 8.9 fold and that of phosphorus deficient plant increased 2.7 fold during the experimental period. Phosphorus deficiency reduced total phosphorus and nitrogen accumulation by 80%,40% respectively, at 28 DAT and 93%, 84%, respectively, at 49 DAT. Nitrogen concentration was reduced by phosphorus deficiency in all tissues with leaf and stem tissues affected to a greater degree than nodule and root tissues at every sampling date. Phosphorus deficiency significantly reduced soluble reduced-N and ureide-N concentration in leaf and stem but did not affect those in root. The proportion of soluble reduced-N in leaf was reduced from 60% to 50% but increased from 10% to 20% in the roots. The proportion of ureide-N in leaf of control plants was higher than that in phosphorus deficient plants, whereas, roots of phosphorus deficient plants contained a higher propotion of ureide-N than those of control plants. These indicated that phosphorus deficiency not only inhibit nitrogen fixation of nodules but also restrict the translocation of fixed nitrogen out of the root system into the xylem.(Received April 4, 1997; accepted May 2, 1997)

  • PDF

Studies on the rabbit viral hepatitis : Immunohistochemical observations (토끼의 바이러스성 간염에 관한 연구 : 면역조직화학적 관찰)

  • Lee, Cha-soo;Shin, Tae-kyun;Choi, Youn-ju;Jeong, Kyu-sik;Jyeong, Jong-sik
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.2
    • /
    • pp.269-275
    • /
    • 1993
  • Tissue distribution of RHDV in rabbits were examined by immunofluorescence and ABC methods. Tissues including liver, spleen, kidneys, lungs and brain were frozen, cut in a crycut, and fixed in 10% buffered formalin, embedded in paraplast, and cut $5{\sim}7{\mu}m$ thickness. Sections were immunostained Tissue distribution of RHDV in rabbits were examined by immunofluorescence and ABC methods. Tissues including liver, spleen, kidneys, lungs and brain were frozen, cut in a crycut, and fixed in 10% buffered formalin, embedded in paraplast, and cut $5{\sim}7{\mu}m$ thickness. Sections were immunostained with primary antiserum and conjugated second antibodies as recommended by manufacturer. None of the cultures tested showed virus-induced phenomena. Immunoreactive products were commonly found in the liver, in some cases there were also positive staining in the spleen and kidneys. Other organs showed weak or insignificant immunoreactions. By ABC method on the formalin-fixed, paraffin-embedded liver tissues, strong immunoreactivity was found in the periportal triad lesions and peripheral lesions of the hepatic lobules. Immunoreactive products showed diffuse fine granular in the cytoplasm of hepatocytes and sinusoidal cells. In some cells, immunoproducts marginate at the periphery of the cells. The intensive staining of the cytoplasm of infected cells allowed their exact differentiation from surrounding uninfected cells. The positive area involved coincided with histopathological lesion on serial liver sections. In conclusion, liver was proved to be a consistent target organ in RHD, and the immunoperoxidase method in the section of formalin-fixed, paraffin-embedded hepatic tissue could be broadly used for the routine diagnosis of the disease.

  • PDF

Effect of Low Magnetic Field on Dose Distribution in the Partial-Breast Irradiation (부분유방 방사선조사 시 저자기장이 선량분포에 미치는 영향)

  • Kim, Jung-in;Park, So-Yeon;Lee, Yang Hoon;Shin, Kyung Hwan;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.208-214
    • /
    • 2015
  • The aim of this study is to investigate the effect of low magnetic field on dose distribution in the partial-breast irradiation (PBI). Eleven patients with an invasive early-stage breast carcinoma were treated prospectively with PBI using 38.5 Gy delivered in 10 fractions using the $ViewRay^{(R)}$ system. For each of the treatment plans, dose distribution was calculated with magnetic field and without magnetic field, and the difference between dose and volume for each organ were evaluated. For planning target volume (PTV), the analysis included the point minimum ($D_{min}$), maximum, mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$) and 107% ($V_{107%}$) of the prescribed dose, respectively. For organs at risk (OARs), the ipsilateral lung was analyzed with $D_{mean}$ and the volume receiving 20 Gy ($V_{20\;Gy}$), and the contralateral lung was analyzed with only $D_{mean}$. The heart was analyzed with $D_{mean}$, $D_{max}$, and $V_{20\;Gy}$, and both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$ and $D_{mean}$, respectively. For PTV, the effect of low magnetic field on dose distribution showed a difference of up to 2% for volume change and 4 Gy for dose. In OARs analysis, the significant effect of the magnetic field was not observed. Despite small deviation values, the average difference of mean dose values showed significant difference (p<0.001), but there was no difference of point minimum dose values in both sehll structures. The largest deviation for the average difference of $D_{max}$ in the outer shell structure was $5.0{\pm}10.5Gy$ (p=0.148). The effect of low magnetic field of 0.35 T on dose deposition by a Co-60 beam was not significantly observed within the body for PBI IMRT plans. The dose deposition was only appreciable outside the body, where a dose build-up due to contaminated electrons generated in the treatment head and scattered electrons formed near the body surface.

Radiation Absorbed Dose Calculation Using Planar Images after Ho-166-CHICO Therapy (Ho-166-CHICO 치료 후 평면 영상을 이용한 방사선 흡수선량의 계산)

  • 조철우;박찬희;원재환;왕희정;김영미;박경배;이병기
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.155-162
    • /
    • 1998
  • Ho-l66 was produced by neutron reaction in a reactor at the Korea Atomic Energy Institute (Taejon, Korea). Ho-l66 emits a high energy beta particles with a maximum energy of 1.85 MeV and small proportion of gamma rays (80 keV). Therefore, the radiation absorbed dose estimation could be based on the in-vivo quantification of the activity in tumors from the gamma camera images. Approximately 1 mCi of Ho-l66 in solution was mixed into the flood phantom and planar scintigraphic images were acquired with and without patient interposed between the phantom and scintillation camera. Transmission factor over an area of interest was calculated from the ratio of counts in selected regions of the two images described above. A dual-head gamma camera(Multispect2, Siemens, Hoffman Estates, IL, USA) equipped with medium energy collimators was utilized for imaging(80 keV${\pm}$10%). Fifty-nine year old female patient with hepatoma was enrolled into the therapeutic protocol after the informed consent obtained. Thirty millicuries(110MBq) of Ho-166-CHICO was injected into the right hepatic arterial branch supplying hepatoma. When the injection was completed, anterior and posterior scintigraphic views of the chest and pelvic regions were obtained for 3 successive days. Regions of interest (ROIs) were drawn over the organs in both the anterior and posterior views. The activity in those ROIs was estimated from geometric mean, calibration factor and transmission factors. Absorbed dose was calculated using the Marinelli formula and Medical Internal Radiation Dose (MIRD) schema. Tumor dose of the patient treated with 1110 MBq(30 mCi) Ho-l66 was calculated to be 179.7 Gy. Dose distribution to normal liver, spleen, lung and bone was 9.1, 10.3, 3.9, 5.0 % of the tumor dose respectively. In conclusion, tumor dose and absorbed dose to surrounding structures were calculated by daily external imaging after the Ho-l66 therapy for hepatoma. In order to limit the thresholding dose to each surrounding organ, absorbed dose calculation provides useful information.

  • PDF

Comparing the dosimetric impact of fiducial marker according to density override method : Planning study (양성자 치료계획에서 fiducial marker의 density override 방법에 따른 선량변화 비교 : Planning study)

  • Sung, Doo Young;Park, Seyjoon;Park, Ji Hyun;Park, Yong Chul;Park, Hee Chul;Choi, Byoung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2017
  • Purpose: The application of density override is very important to minimize dose calculation errors by fiducial markers of metal material in proton treatment plan. However, density override with actual material of the fiducial marker could make problem such as inaccurate target contouring and compensator fabrication. Therefore, we perform density override with surrounding material instead of actual material and we intend to evaluate the usefulness of density override with surrounding material of the fiducial marker by analyzing the dose distribution according to the position, material of the fiducial marker and number of beams. Materials and Method: We supposed that the fiducial marker of gold, steel, titanium is located in 1.5, 2.5, 4.0, 6.0 cm from the proton beam's end of range using water phantom. Treatment plans were created by applying density override with the surrounding material and actual material of the fiducial marker. Also, a liver cancer patient who received proton therapy was selected. We located the fiducial marker of gold, steel, titanium in 0, 1.5, 3.5 cm from the proton beam's end of range and the treatment plans were created by same method with water phantom. Homogeneity Index(HI), Conformity Index(CI) and maximum dose of Organ At Risk(OAR) in Planning Target Volume(PTV) as the evaluation index were compared according to the material, position of the fiducial marker and number of beam. Results: The HI value was more decreased when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Especially the HI value was increased when the fiducial marker was located farther from the proton beam's end of the range for a single beam and the fiducial marker's position was closer to isocenter for two or more beams. The CI value was close to 1 and OAR maximum dose was greatly reduced when density override with surrounding material of the fiducial marker was performed comparing with density override with actual material. Conclusion: Density override with surrounding material can be expected to achieve more precise proton therapy than density override with actual material of the fiducial marker and could increase the dose uniformity and target coverage and reduce the dose to surrounding normal tissues for the small fiducial markers used in clinical practice. Most of all, it is desirable to plan the treatment by avoiding the fiducial marker of metal material as much as possible. However, if the fiducial marker have on the beam path, density override of the surrounding material can be expected to achieve more precise proton therapy.

  • PDF

Dosimetric comparison for Prostate VMAT of weight and photon energy change (전립선 암 입체적세기변조방사선치료 시 체형 및 에너지 변화에 따른 선량 평가)

  • Jo, Guang Sub;Kim, Min Woo;Baek, Min Gyu;Chae, Jong Pyo;Ha, Se Min;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.17-25
    • /
    • 2018
  • Purpose : To compare the radiation doses of prostate cancer patients according to changes in abdominal body shape and energy during Volumetric modulated arc therapy(VMAT). Materials and Methods : Seven patients with prostate cancer were enrolled in this study. VMAT treatment plan was established at 6, 10, and 15 MV while changing from -2.0 cm to 2 cm by 0.5 cm. Conformal index(CI), homogeneous index(HI), $D_{max}$, $D_{95%}$, $D_{50%}$ and $D_{2%}$ of PTV were examined in order to evaluate the change of dose in the target organ according to body shape change. Normal organ of the femoral head, rectum and bladder was analyzed to evaluate dose changes. Results : The dose of $D_{max}$ 6 MV in PTV increased to 107.2 % in 1.0 cm body shape reduction, and 10 MV and 15 MV dose increased to 107.1 % and 107.0 % in 1.5 cm body reduction, respectively. The dose of $D_{50%}$ 6 MV in PTV decreased to 99.64 % in 1.0 cm body shape increase, and in 10 MV and 15 MV dose decreased to 99.79 % and 99.97 % in 1.5 cm body increase, respectively. In 2.0 cm body type increase, the dose was decreased to 99.30 % and 99.52 %, respectively. Doses for rectum and bladder gradually increased with decreasing weight, and dose decreased with decreasing weight. 6 MV, and $V_{70Gy}$ at 10 MV increased from 11.50 % to 12.76 % when the external shape decreased by 2.0 cm. The bladder $V_{70Gy}$ also increased from 14.0 % to 15.2 %. It was also shown that the dose increased as the body weight decreased in the femoral head. Conclusion : In the treatment of VMAT, dose distribution can be changed according to the change of abdominal shape. SSD and CBCT were used to decrease the body shape by more than 1cm or more than 1.0 cm at 6 MV and the body shape by more than 1.5 cm or more than 1.5 cm at 10 MV or 15 MV. It is considered that a new treatment plan should be established through re-simulation.

  • PDF