• Title/Summary/Keyword: orbital fractures

Search Result 124, Processing Time 0.02 seconds

Orbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter (내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술)

  • Choi, Hwan-Jun;Lee, Joo-Chul;Lee, Hyung-Gyo;Kim, Jun-Hyuk
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.35-42
    • /
    • 2011
  • Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

  • Lee, Kyung Min;Park, Ji Ung;Kwon, Sung Tack;Kim, Suk Wha;Jeong, Eui Cheol
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.480-485
    • /
    • 2014
  • Background The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. Methods Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach with lateral canthotomy was used for the exposure of fractures. An appropriate three-dimensional preformed titanium implant was selected and inserted according to the characteristics of a given defect. Results Follow-up time ranged from 2 to 6 months (median, 4.07 months). All patients had a successful treatment outcome without any complications. Clinically significant enophthalmos was not observed after treatment. Conclusions Three-dimensional pre-bent titanium implants are appropriate for use in the East Asian population, with a high success rate of anatomic restoration of the orbital volume and prevention of enophthalmos in combined orbital floor and medial wall fracture cases.

Orbital wall restoring surgery with resorbable mesh plate

  • Joo, Jae Doo;Kang, Dong Hee;Kim, Hyon Surk
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.4
    • /
    • pp.264-269
    • /
    • 2018
  • Background: Orbital resorbable mesh plates are adequate to use for isolated floor and medial wall fractures with an intact bony buttress, but are not recommended to use for large orbital wall fractures that need load bearing support. The author previously reported an orbital wall restoring surgery that restored the orbital floor to its prior position through the transnasal approach and maintained temporary extraorbital support with a balloon in the maxillary sinus. Extraorbital support could reduce the load applied on the orbital implants in orbital wall restoring surgery and the use of resorbable implants was considered appropriate for the author's orbital wall restoring technique. Methods: A retrospective review was conducted of 31 patients with pure unilateral orbital floor fractures between May 2014 and May 2018. The patients underwent transnasal restoration of the orbital floor through insertion of a resorbable mesh plate and maintenance of temporary balloon support. The surgical results were evaluated by the Hertel scale and a comparison of preoperative and postoperative orbital volume ratio (OVR) values. Results: The OVR decreased significantly, by an average of 6.01% (p<0.05) and the preoperative and postoperative Hertel scale measurements decreased by an average of 0.34 mm with statistical significance (p<0.05). No complications such as buckling or sagging of the implant occurred among the 31 patients. Conclusion: The use of resorbable mesh plate in orbital floor restoration surgery is an effective and safe technique that can reduce implant deformation or complications deriving from the residual permanent implant.

Traumatic Superior orbital fissure syndrome complicating fractures of the facial skeleton;Report of a Case (악안면 골절후 발생된 상안와열증후군;증례보고)

  • Kim, Su-Gwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.356-359
    • /
    • 2000
  • Superior orbital fissure syndrome is characterized by ophthalmoplegia, ptosis of the eye, reflex dilation of the pupil, and anesthesia of the upper eyelid and forehead. This syndrome may be the result of craniofacial fractures as well as neoplasms of the retrobulbar space, hematomas in the orbital muscle cone and retrobulbar space, and hematoma and infection of the cavernous sinus. A case of superior orbital fissure syndrome is described.

  • PDF

Prevalence of Diplopia and Extraocular Movement Limitation according to the Location of Isolated Pure Blowout Fractures

  • Park, Min-Seok;Kim, Young-Joon;Kim, Hoon;Nam, Sang-Hyun;Choi, Young-Woong
    • Archives of Plastic Surgery
    • /
    • v.39 no.3
    • /
    • pp.204-208
    • /
    • 2012
  • Background : Isolated pure blowout fractures are clinically important because they are the main cause of serious complications such as diplopia and limitation of extraocular movement. Many reports have described the incidence of blowout fractures associated with diplopia and limitation of extraocular movement; however, no studies have statistically analyzed this relationship. The purpose of this study was to demonstrate the correlation between the location of isolated pure blowout fractures and orbital symptoms such as diplopia and limitation of extraocular movement. Methods : We enrolled a total of 354 patients who had been diagnosed with isolated pure blowout fractures, based on computed tomography, from June 2008 to November 2011. Medical records were reviewed, and the prevalence of extraocular movement limitations and diplopia were determined. Results : There were 14 patients with extraocular movement limitation and 58 patients complained of diplopia. Extraocular movement limitation was associated with the following findings, in decreasing order of frequency: floor fracture (7.1%), extended fracture (3.6%), and medial wall (1.7%). However, there was no significant difference among the types of fractures (P=0.60). Diplopia was more commonly associated with floor fractures (21.4%) and extended type fractures (23.6%) than medial wall fractures (10.4%). The difference was statistically significant (Bonferroni-corrected chi-squared test P<0.016). Conclusions : Data indicate that extended type fractures and orbital floor fractures tend to cause diplopia more commonly than medial wall fractures. However, extraocular movement limitation was not found to be dependent on the location of the orbital wall fracture.

Anatomical Reconstruction of the Medial Orbital Wall Fracture (안와내벽골절의 해부학적 복원술)

  • Choi, Woo Kyung;Kang, Dong Hee;Oh, Sang Ah
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: In surgical treatment of the medial orbital wall fractures, restoring the original position of the orbital wall is difficult in some cases. Under such condition, the orbital wall is often reconstructed with synthetic material, without bony reduction, which is considered to be the conventional reconstruction. The purpose of this study is to compare the outcomes of anatomical reconstruction, which restores the bony wall to the anatomical position, from that of the conventional reduction in the isolated medial orbital wall fractures. Methods: Thirty patients, who underwent reconstruction surgery for the isolated medial orbital wall fractures from March 2007 to August 2011, were reviewed retrospectively. The surgical outcomes of two groups, the conventional reconstruction group (15 patients) and the anatomical reconstruction group (15 patients), were studied in 2 measurements, a one day before and 6 months after the surgery. The changes of orbital volume were calculated by the images from a computed tomography scan and enophthalmos was measured by a Hertel exophthalmometer. Results: The orbital volume ratio was decreased by an average of 1.05% in the conventional reconstruction group, while in the anatomical reconstruction group, the ratio decreased by 5.90% (p<0.05). The changes in the Hertel scale were 0.20 mm in the conventional reconstruction group, and 0.70 mm in the anatomical reconstruction group. However, the difference in the Hertel scale was statistically insignificant (p>0.05). Conclusion: In conclusion, the anatomical reconstruction technique of the isolated medial orbital wall fracture results in a better outcome than that of the conventional reconstruction, in terms of restoring of the original orbital volume and anatomic position. Thus, it can be considered as a useful method for the isolated medial orbital wall fractures.

Orbital Floor Fracture

  • Kim, Hyo Seong;Jeong, Eui Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.111-118
    • /
    • 2016
  • The medial wall and floor of the bony orbit are frequently fractured because of the delicate anatomy. To optimize functional and aesthetic results, reconstructive surgeons should understand the anatomy and pathophysiology of orbital fractures. Appropriate treatment involves optimal timing of intervention, proper indications for operative repair, incision and dissection, release of herniated tissue, implant material and placement, and wound closure. The following review will discuss the management of orbital floor fractures, with the operative method preferred by the author. Special considerations in operation technique and the complication are also present in this article.

Orbital roof and supraorbital ridge fracture: a report of three cases (상안와벽 및 상안와연 골절의 치험례)

  • Lee, Jae-Yeol;Lee, Sung-Tak;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Uk-Kyu;Chung, In-Kyo;Hwang, Dae-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.6
    • /
    • pp.524-529
    • /
    • 2011
  • Orbital roof and supraorbital ridge fractures are frequently associated with high energy concomitant craniofacial trauma. When a displacement of the orbital roof and supraorbital rim occurs, exploration, stabilization and reconstruction are warranted to limit the ocular complications. The management of fractures involving the frontal sinus must consider the possible need for obliteration or cranialization of the sinus. Many incisions have been described and used to approach these fractures, such as a coronal incision, eyebrow incision, and an incision through the laceration. We report 3 cases of orbital roof and supraorbital ridge fracture patients with a review of the relevant literature.

Reconstruction of the orbital wall using superior orbital rim osteotomy in a patient with a superior orbital wall fracture

  • Heo, Jae Jin;Chong, Ji-Hun;Han, Jeong Joon;Jung, Seunggon;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.42.1-42.5
    • /
    • 2018
  • Background: Fractures of the orbital wall are mainly caused by traffic accidents, assaults, and falls and generally occur in men aged between 20 and 40 years. Complications that may occur after an orbital fracture include diplopia and decreased visual acuity due to changes in orbital volume, ocular depression due to changes in orbital floor height, and exophthalmos. If surgery is delayed too long, tissue adhesion will occur, making it difficult to improve ophthalmologic symptoms. Thus, early diagnosis and treatment are important. Fractures of the superior orbital wall are often accompanied by skull fractures. Most of these patients are unable to perform an early ocular evaluation due to neurosurgery and treatment. These patients are more likely to show tissue adhesion, making it difficult to properly dissect the tissue for wall reconstruction during surgery. Case presentation: This report details a case of superior orbital wall reconstruction using superior orbital rim osteotomy in a patient with a superior orbital wall fracture involving severe tissue adhesion. Three months after reconstruction, there were no significant complications. Conclusion: In a patient with a superior orbital wall fracture, our procedure is helpful in securing the visual field and in delamination of the surrounding tissue.

Application of Rapid Prototyping Technique and Intraoperative Navigation System for the Repair and Reconstruction of Orbital Wall Fractures

  • Cha, Jong Hyun;Lee, Yong Hae;Ruy, Wan Chul;Roe, Young;Moon, Myung Ho;Jung, Sung Gyun
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.146-153
    • /
    • 2016
  • Background: Restoring the orbital cavity in large blow out fractures is a challenge for surgeons due to the anatomical complexity. This study evaluated the clinical outcomes and orbital volume after orbital wall fracture repair using a rapid prototyping (RP) technique and intraoperative navigation system. Methods: This prospective study was conducted on the medical records and radiology records of 12 patients who had undergone a unilateral blow out fracture reconstruction using a RP technique and an intraoperative navigation system from November 2014 to March 2015. The surgical results were assessed by an ophthalmic examination and a comparison of the preoperative and postoperative orbital volume ratio (OVR) values. Results: All patients had a successful treatment outcome without complications. Volumetric analysis revealed a significant decrease in the mean OVR from $1.0952{\pm}0.0662$ (ranging from 0.9917 to 1.2509) preoperatively to $0.9942{\pm}0.0427$ (ranging from 0.9394 to 1.0680) postoperatively. Conclusion: The application of a RP technique for the repair of orbital wall fractures is a useful tool that may help improve the clinical outcomes by understanding the individual anatomy, determining the operability, and restoring the orbital cavity volume through optimal implant positioning along with an intraoperative navigation system.