• 제목/요약/키워드: orbital fractures

검색결과 124건 처리시간 0.025초

A novel technique for placing titanium mesh with porous polyethylene via the endoscopic transnasal approach into the orbit for medial orbital wall fractures

  • Bae, Seong Hwan;Jeong, Dae Kyun;Go, Ju Young;Park, Heeseung;Kim, Joo Hyoung;Lee, Jae Woo;Kang, Taewoo
    • Archives of Plastic Surgery
    • /
    • 제46권5호
    • /
    • pp.421-425
    • /
    • 2019
  • Background The endoscopic transnasal approach is widely used for reconstructing the medial orbital wall by filling it with a silicone sheet or Merocel, but this technique has the disadvantage of retaining the packing for a long time. To overcome this drawback, a method of positioning an absorbable plate in the orbit has been introduced, but there is a risk of defect recurrence after the plate is absorbed. Here, the authors report the results of a novel surgical technique of placing a nonabsorbable titanium mesh with porous polyethylene into the orbit through the endoscopic transnasal approach. Methods Fourteen patients underwent surgery using the endoscopic transnasal approach. Preoperative computed tomography (CT) was used to calculate the size of the bone defect due to the fracture, and the titanium mesh was designed to be shorter than the anteroposterior length of the defect and longer than its height. The titanium mesh was inserted into the orbit under an endoscopic view. The authors then confirmed that the titanium mesh supported the orbital contents by pressing the eyeball and finished the operation. Immediately after surgery, CT results were evaluated. Results Postoperative CT scans confirmed that the titanium mesh was well-inserted and in the correct position. All patients were discharged without any complications. Conclusions We obtained satisfactory results by inserting a titanium mesh with porous polyethylene into the orbit via the transnasal approach endoscopically.

Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report

  • Shin, Jin Yong;Lee, Nae-Ho;Kim, Min-Seok;Roh, Si-Gyun;Chung, Yoon Kyu
    • 대한두개안면성형외과학회지
    • /
    • 제23권5호
    • /
    • pp.228-231
    • /
    • 2022
  • Fibrin glue is a topical agent widely used for hemostasis, wound healing, and surgical adhesion. Complications of fibrin glue itself are extremely rare because it is absorbed over time, but can occur as a result of inappropriate application. We report a case of a postoperative complication caused by inappropriate application of fibrin glue in blow-out fracture surgery. A 65-year-old male patient presented with periorbital swelling and an open wound on the right infraorbital area. Computed tomography showed a right orbital floor fracture. After reduction of the herniated tissue into the orbit, an implant was inserted and fibrin glue was applied to stabilize the implant. This procedure was performed without difficulty, but the patient complained of persistent diplopia and limited eyeball movement after surgery. An imaging study showed a mass-like lesion, which was not a hematoma, in the orbital cavity. In a second operation, the mass was identified as clotted fibrin glue that had not been applied properly. After removal, the patient's symptoms were relieved without further complications. Appropriate and careful application of fibrin glue is necessary to avoid unnecessary complications.

안와골절에서 결막절개를 통한 Medpor 내고정술의 합병증 분석과 치료 (Analysis and Management of Complications of Open Reduction and Medpor Insertion through Transconjunctival Incision in Blowout Fractures)

  • 이지원;최재일;하원;양완석
    • 대한두개안면성형외과학회지
    • /
    • 제13권1호
    • /
    • pp.22-28
    • /
    • 2012
  • Purpose: In accordance to an increased interest in facial appearance and the popularization of computed tomography scanning, the number of diagnosis and treatment of blowout fractures has been increased. The purpose of this article is to review pure blowout fracture surgery through transconjunctival incision focusing on complications and their management. Methods: In this retrospective study, 583 patients, who had been treated for pure blowout fracture through transconjunctival incision from 2000 to 2009, were evaluated. Their hospital records were reviewed according to their sex, age, fracture site, preoperative presentations, time interval between trauma and surgery, and postoperative complications. Results: According to postoperative follow-up results, there were early complications that included wound dehiscence and infection (0.2%), hematoma (insomuch as extraocular movement is limited) (0.7%), lacriminal duct injury (0.5%), and periorbital nerve injury (0.7%). In addition, there were late complications that lasted more than 6 months, that included persistent diplopia (1.7%), extraocular movement limitation (0.9%), enophthalmos (1.0%), periorbital sensation abnormalities (1.0%), and entropion (0.5%). Conclusion: We propose the following guidelines for prevention of postoperative complications: layer by layer closure; bleeding control with the epinephrine gauzes, Tachocomb, and Tisseel; conjunctival incision 2 to 3 mm away from punctum; avoidance of excessive traction; performing surgical decompression and high dose corticosteroid therapy upon confirmation of nerve injury; atraumatic dissection and insertion of Medpor Barrier implant after securing a clear view of posterior ledge; using Medpor block stacking technique and BioSorb FX screw fixation; performing a complete resection of the anterior ethmoidal nerve during medial wall dissection; and making an incision 2 to 3 mm below the tarsal plate.

비안와 사골골절의 치료;증례보고 (TREATMENT OF NASO-ORBITO ETHMOIDAL FRACTURE;A CASE REPORT)

  • 김영균;여환호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제16권1호
    • /
    • pp.72-78
    • /
    • 1994
  • A naso-orbito-ethmoid(NOE) fracture is very complex diagnostically and therapeutically. The diagnosis of this fractures is usually made by physical findings aided by a CT scan. The primary treatment of NOE fracture must be directed toward the reconstruction of medial canthal ligament and bony skeleton. We prefer to correct lacrimal system abnormalities secondarily A 32-year old male patient visited emergency room of our hospital with NOE fracture. After emergency treatment and consultation with neurosurgery and ophthalmology, we treated this patient by performing reconstruction of medial canthal ligament, bone graft of media orbital rim blowout fracture, and dorsal nasal cantilever bone graft with calvarial bone. The authors present a case report with literature review.

  • PDF

Retrobulbar Hematoma in Blow-Out Fracture after Open Reduction

  • Cheon, Ji Seon;Seo, Bin Na;Yang, Jeong Yeol;Son, Kyung Min
    • Archives of Plastic Surgery
    • /
    • 제40권4호
    • /
    • pp.445-449
    • /
    • 2013
  • Retrobulbar hemorrhage, especially when associated with visual loss, is a rare but significant complication after facial bone reconstruction. In this article, two cases of retrobulbar hematoma after surgical repair of blow-out fracture are reported. In one patient, permanent loss of vision was involved, but with the other patient, we were able to prevent this by performing immediate decompression after definite diagnosis. We present our clinical experience with regard to the treatment process and method for prevention of retrobulbar hematoma using a scalp vein set tube and a negative pressure drainage system.

Isolated Oculomotor Nerve Palsy Following Minor Head Trauma : Case Illustration and Literature Review

  • Kim, Ealmaan;Chang, Hyukwon
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권5호
    • /
    • pp.434-436
    • /
    • 2013
  • Isolated oculomotor nerve palsy (ONP) attributable to mild closed head trauma is a distinct rarity. Its diagnosis places high demands on the radiologist and the clinician. The authors describe this condition in a 36-year-old woman who slipped while walking and struck her face. Initial computed tomography did not reveal any causative cerebral and vascular lesions or orbital and cranial fractures. Enhancement and swelling of the cisternal segment of the oculomotor nerve was seen during the subacute phase on thin-sectioned contrast-enhanced magnetic resonance images. The current case received corticosteroid therapy, and then recovered fully in 13 months after injury. Possible mechanism of ONP from minor head injury is proposed and previous reports in the literature are reviewed.

외상 후 안면변형에 대한 지연재건술 (Delayed reconstruction of posttraumatic facial deformities)

  • 김용하
    • 대한의사협회지
    • /
    • 제61권12호
    • /
    • pp.740-748
    • /
    • 2018
  • Posttraumatic facial deformities (PTFDs) are very difficult to correct, and if they do occur, their impact can be devastating. It may sometimes be impossible for patients to return to normal life. The aim of surgical treatment is to restore the deformed bone structure and soft tissue to create symmetry between the affected side and the opposite side. In the process of managing PTFD, correcting enophthalmos is one of the most challenging aspects for surgeons because of difficulties in overcoming the scar tissue and danger of injuring to the optic nerve. In this article, surgical options for reconstruction of the medial wall, floor, lateral wall, and roof of the orbit are described. To optimize aesthetic improvement, additional cosmetic procedures such as facial contouring surgery, blepharoplasty and rhinoplasty can be used. Plastic surgeons should join emergency trauma teams to implement an overall treatment plan containing rational strategies to avoid or minimize PTFD.

Late reconstruction of post-traumatic enophthalmos and hypoglobus using three-dimensional implants: a case series

  • Choi, Jae Hyeok;Baek, Wooyeol
    • 대한두개안면성형외과학회지
    • /
    • 제23권5호
    • /
    • pp.232-236
    • /
    • 2022
  • Post-traumatic enophthalmos and hypoglobus are common sequelae of facial bone fractures, even after reduction surgery. They are associated with functional and esthetic issues, which may lower the quality of life. These deformities frequently present late, and adequate correction is difficult. We report three cases of late inferior orbital rim reconstructions with three-dimensional printed implants to help resolve these problems. The average duration between the traumatic event and surgery was 3 years and 4 months. One patient was treated with a completely absorbable implant and exhibited satisfactory results until the implant started to biodegrade at 1 year and 9 months after surgery. Two patients were treated with a permanent implant and demonstrated satisfactory results. However, longer follow-up periods were needed. There were no complications such as infection, diplopia, or restriction of ocular motion and the patients were satisfied with the esthetic results.

Delayed treatment of traumatic eyeball dislocation into the maxillary sinus and treatment algorithm: a case report and literature review

  • Hoon Kim;Keun Hyung Kim;In Chang Koh;Ga Hyun Lee;Soo Yeon Lim
    • 대한두개안면성형외과학회지
    • /
    • 제25권1호
    • /
    • pp.31-37
    • /
    • 2024
  • Orbital floor fractures are commonly encountered, but the dislocation of the eyeball into the maxillary sinus is relatively rare. When it does occur, globe dislocation can have serious consequences, including vision loss, enucleation, and orbito-ocular deformity. Immediate surgical intervention is typically attempted when possible. However, severe comorbidities and poor general health can delay necessary surgery. In this report, we present the surgical outcomes of a 70-year-old woman who received delayed treatment for traumatic eyeball dislocation into the maxillary sinus due to a subarachnoid hemorrhage and hemopneumothorax. Additionally, we propose a treatment algorithm based on our clinical experience and a review of the literature.

The Efficacy of Bioabsorbable Mesh in Craniofacial Trauma Surgery

  • Choi, Won Chul;Choi, Hyun Gon;Kim, Jee Nam;Lee, Myung Cheol;Shin, Dong Hyeok;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • 대한두개안면성형외과학회지
    • /
    • 제17권3호
    • /
    • pp.135-139
    • /
    • 2016
  • Background: The ultimate goal of craniofacial reconstructive surgery is to achieve the most complete restoration of facial functions. A bioabsorbable fixation system which does not need secondary operation for implant removal has been developed in the last decade. The purpose of this study is to share the experience of authors and to demonstrate the efficacy of bioabsorbable mesh in a variety of craniofacial trauma operations. Methods: Between October 2008 and February 2015, bioabsorbable meshes were used to reconstruct various types of craniofacial bone fractures in 611 patients. Any displaced bone fragments were detached from the fracture site and fixed to the mesh. The resulting bone-mesh complex was designed and molded into an appropriate shape by the immersion in warm saline. The mesh was molded once again under simultaneous warm saline irrigation and suction. Results: In all patients, contour deformities were restored completely, and bone segments were fixed properly. The authors found that the bioabsorbable mesh provided rigid fixation without any evidence of integrity loss on postoperative computed tomography scans. Conclusion: Because bioabsorbable meshes are more flexible than bioabsorbable plates, they can be molded and could easily reconstruct the facial bone in three dimensions. Additionally, it is easy to attach bone fragments to the mesh. Bioabsorbable mesh and screws is effective and can be easily applied for fixation in various craniofacial trauma reconstructive scenarios.