• Title/Summary/Keyword: oral temperature

Search Result 308, Processing Time 0.028 seconds

Antioxidant effect of Lonicera Caerulea on heat stress-treated male mice

  • Kang, Donghun;Kim, Daeyoung
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.36 no.4
    • /
    • pp.220-229
    • /
    • 2021
  • Lonicera caerulea (Honey berry, HB) has been used in medical treatment in Russia, Japan, China and Korea. It has high level of vitamin C and polyphenolics. Polyphenolics can improve anti-inflammatory effect and prevent cancer, diabetes mellitus type 2. Also, Vitamin C is a representative anti-oxidant. however, it is still unknown what effect it will have on the oxidation stress of the reproductive system. In previous studies, ROS can be produced when it is exposed to heat stress and has negative effect on sperm's maturation, capacitation, hyperactivation, acrosome reaction and fusion of egg and sperm. Therefore, the purpose of this study is to investigate the antioxidant effects of L. Caerulea on the sperm and mice. At first, it conducted using ICR mouse (n = 20) for 4 weeks. There are four groups of mice (n = 5 per group). Also, L. Caerulea was taken by oral gavage. Group I (control) kept at 23℃-27℃ and administer D.W (0.5 mL/day), Likewise, Group II (HB) kept at room temperature but gave HB (250 mg/kg, 0.5 mL/day), Group III (HB + HS) received heat stress (40℃) using hyperthermia induction chamber and gave HB at same dose. and Group IV (HS) exposed heat stress only. Mainly, we showed degree of gene expression using Western blot in SOD, HSP 70, 17β-HSD and Real-time PCR. It can find correlation between intracellular activity like steroid hormone, apoptosis under ROS and antioxidant activity of L. Caerulea.

DEVELOPMENT OF POLYETHOXYLATED RETINAMIDE AS AN ANTl-AGINC AGENT

  • Song, Young-Sook;Chung, Bong-Yul;Chang, Min-Youl;Park, Mun-Eok;Lee, Sung-Jun;Cho, Wan-Goo;Kang, Seh-Hoon
    • Proceedings of the SCSK Conference
    • /
    • 1999.10a
    • /
    • pp.145-154
    • /
    • 1999
  • A novel retinol derivative, polyethoxylated retinamide (Medimin A) was synthesized, as an anti-aging agent. Collagen synthesis, skin permeation, stability, and toxicity of Medimin A were evaluated and compared with those of retinol and retinyl palmitate. In vitro collagen synthesis was evaluated by quantitative assay of [$^3H$]-proline incorporation into collagenase sensitive protein in fibroblast cultures. For in vitro skin permeation experiments, Franz diffusion cells (effective diffusion area: $1, 766{\;}\textrm{cm}^2$) and the excised skin of female hairless mouse aged 8 weeks were used The stabilities of retlnoids were evaluated at two different temperature ($25{\;}^{\circ}C$ and $40{\;}^{\circ}C$) and under UV in solubilized state and in OW emulsion. To estimate the safety, acute oral toxicity, acute dermal toxicity, primary skin irritation, acute eye irritation and human patch test were performed The effect of Medimin A on collagen synthesis was similar to that of retinol. The skin permeability of Medimin A was higher than those of retinol and retinyl palmitate. The Medimin A was more stable than retinol and retinyl palmitate. Medimin A was nontoxic in various toxicological tests. These results suggest that Medimin A would be a good anti-aging agent for enhancing bioavailability and stability.

  • PDF

Temporal Changes in the Physiological and Psychological Relaxation Effects of a Forest Environment during the Summer (시간 변화에 따른 여름철 산림환경의 생리ᐧ심리적 안정 효과)

  • Injoon Song;Juhyeon Kim;Choyun Kim;Dawou Joung;Yunjeong Yi;Bum-Jin Park;Chorong Song
    • Journal of Korean Society of Forest Science
    • /
    • v.113 no.1
    • /
    • pp.107-117
    • /
    • 2024
  • This study investigated temporal changes in forest physical variables and their effects on thermal comfort and physiological and psychological responses. Environmental factors (air temperature, mean radiant temperature, wind speed, and relative humidity), the predicted mean vote (PMV), and the predicted percentage of dissatisfied (PPD) visitors were continuously measured between 9:00 AM and 6:00 PM. We assessed the physiological and psychological responses (heart rate variability, heart rate, oral temperature, blood pressure, pulse rate, thermal sensation vote, comfort sensation vote, and subjective feelings) of 30 male university students (average age: 21.7±1.9 years), who closed their eyes and relaxed for 5 minutes every hour. Examination of correlations between environmental factors and physiological responses showed that ① the mean radiant temperature, wind speed, and relative humidity significantly changed with time; ② PMV and PPD also showed significant changes over time, and the thermal sensation vote corresponded with PMV; however, the comfort sensation vote did not correspond with PPD; ③ Among the physiological responses, parasympathetic nerve activity, sympathetic nerve activity, heart rate, and diastolic blood pressure significantly varied with time, with parasympathetic nerve activity having the lowest value and sympathetic nerve activity the highest at the highest air temperature (2:00-4:00 PM); and ④ Air temperature, mean radiant temperature, and wind speed showed a negative correlation with parasympathetic nerve activity and a positive correlation with sympathetic nerve activity. These findings indicate that the relaxation effects of the forest environment depend on what time of day people are exposed to it, and the changes occurring in forest environmental factors over time modulate these effects.

Effect of Oxytetracycline Injection an the Body of Paralichthys Olivaceus (Oxytetracycline의 투여방법에 따른 넙치(Paralichthys olivaceus) 체내의 잔류 특성)

  • Ko, Chang-Sik;Kim, Dong-Hwi;Park, So-Hyun;Moon, Kyung-Mi;Heo, Moon-Soo
    • Journal of Life Science
    • /
    • v.26 no.3
    • /
    • pp.309-317
    • /
    • 2016
  • Industrial advancements have resulted in food culture development, followed by increased seafood consumption and large-scale seafood farming, which has been accompanied by an increased prevalence of fish disease. The antibiotic oxytetracycline (OTC) is commonly used to prevent and treat bacterial diseases in fish. However, overuse of OTC had led to negative aspects. In view of this, we conducted a research with regard to aspects of remnants on olive flounder skin, liver, and muscle through dipping treatment and oral feeding of OTC and analyzed the results with bioassay and HPLC quantitative analyses. The dipping treatment was carried out once with 25 g/ton/hr of OTC, and the oral treatment with 62.5 mg/kg body weight/7 days. The results underwent a bioassay analysis. The dipping group reacted only on the skin right after dipping, while the oral feeding group responded on the skin for 77 days after feeding and on the muscle for 14 days. In the dipping group, the HPLC quantitative analysis revealed remnants in the skin on the 37th day and on the 13th day in the liver group. No remnants were found in the muscle, even immediately after dipping. In the oral feeding group, there was a high concentration (1.07 mg/kg) of remnant in the skin, even on the 77th day. 0.56 mg/kg in the liver, even a small amount, and no remnant in the muscle on the 42nd day. To sum up, the results suggest that it will not be harmful to our body to observe the OTC withdrawal period of 40 days with the muscle because OTC will hardly remain on it. When using olive flounder for sashimi, the skin and liver should not be used for broth, as the quantity of OTC residue is several times higher than that found in muscle. As previous studies reported that the concentration of remnants gradually decreased with heating, so it was likely to lessen, depending on the cooking temperature.

MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA (상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정)

  • Her, Mi-Ja;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

The Effect of Shift Directions of Clinical Nurses on the Circadian Rhythm (임상 간호사의 교대근무 방향아 circadian rhythm 변화에 미치는 영향)

  • Hwang Ae-Ran;Chung Hyun-Sook;Kang Kyu-Sook;Lee Kyu-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.1
    • /
    • pp.77-97
    • /
    • 1994
  • The circadian system represents a temporal order which is mediated by the mutual coupling of oscillators and by the synchronizing effects of zeitgebers. It is known that well-being of man depends partly on the maintenance of this order, and that repeated or long lasting disturbances to it such as shift work will Cause harmful effects. This study was a quasi-experimental study to test the effect of shift directions for the clinical nurses on the circadian rhythm. Fourteen nurses working at the general units of Y hospital were selected according to the established criteria. Fourteen subjects were assigned to a weekly shift but the directions of shift work were phase delay first and then phase advance or vice versa. Oral temperature, total sleeping time, frequency of sleep-wake cycle, fatigue, mental performance, and physical symptom were measured during these days except holidays. The data collection period was from April 26, 1993 to July 3, 1993. MANOVA and Wilcoxon signed rank test were used for statistical analysis. The results are summarized as follows. 1. Having worked on evening and night shifts in either phase delay or phase advance schedules, temperature rhythms of shift workers were gradually adapted to the new sleep-wake cycles. A complete adaptation to work on the night shift was achieved the sixth day of the night shift in the phase delay schedule compared to the partial adaptation to the work on the night shift in the phase advance schedule. Accordingly, by putting evening shift between day and night shifts, it will be possible for circadian rhythm to adapt easily to the night shift. 2. There were differences in the total sleeping time, frequency of steep-wake cycle, fatigue, and physical symptom except for mental performance between night shift and day, evening shift. This indicates further that shift workers working on the night shift have a hard time adapting to the shift work compared to the other shifts. 3. Evaluating all the acrophases of temperature rhythm either in phase delay or phase ad-vance schedules, it was shown that night to evening shift in the phase ad-vance schedule revealed the smallest phase move. Also phase advance schedule showed poorer adaptation to shift work than phase delay schedule in connection with total sleeping time, frequency of sleep-wake cycle, fatigue, mental performance, and physical symptom. It is suggested, taken together, these findings reflect that phase delay schedule facilitated the degree of adjustment to the shift work compared to the phase advance schedule.

  • PDF

THE EVALUATION OF PERIODONTAL LIGAMENT CELLS OF RAT TEETH AFTER LOW-TEMPERATURE PRESERVATION UNDER HIGH PRESSURE (고압-저온 보관에 따른 쥐 치아 치주인대세포의 활성도 평가)

  • Chung, Jin-Ho;Kim, Jin;Choi, Seong-Ho;Kim, Eui-Seong;Park, Ji-Yong;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.285-294
    • /
    • 2010
  • The purpose of this study was to evaluate the viability of periodontal ligament cells of rat teeth after low-temperature preservation under high pressure by means of MTT assay, WST-1 assay. 12 teeth of Sprague-Dawley white female rats of 4 week-old were used for each group. Both side of the first and second maxillary molars were extracted as atraumatically as possible under tiletamine anesthesia. The experimental groups were group 1 (Immediate extraction), group 2 (Slow freezing under pressure of 3 MPa), group 3 (Slow freezing under pressure of 2 MPa), group 4 (Slow freezing under no additional pressure), group 5 (Rapid freezing in liquid nitrogen under pressure of 2 MPa), group 6 (Rapid freezing in liquid nitrogen under no additional pressure), group 7 (low-temperature preservation at $0^{\circ}C$ under pressure of 2 MPa), group 8 (low-temperature preservation at $0^{\circ}C$ under no additional pressure), group 9 (low-temperature preservation at $-5^{\circ}C$ under pressure of 90 MPa). F-medium and 10% DMSO were used as preservation medium and cryo-protectant. For cryo-preservation groups, thawing was performed in $37^{\circ}C$ water bath, then MTT assay, WST-1 assay were processed. One way ANOVA and Tukey HSD method were performed at the 95% level of confidence. The values of optical density obtained by MTT assay and WST-1 were divided by the values of eosin staining for tissue volume standardization. In both MTT and WST-1 assay, group 7 ($0^{\circ}C$/2 MPa) showed higher viability of periodontal ligament cells than other group (2-6, 8) and this was statistically significant (p < 0.05), but showed lower viability than group 1, immediate extraction group (no statistical significance). By the results of this study, low-temperature preservation at $0^{\circ}C$ under pressure of 2 MPa suggest the possibility for long term preservation of teeth.

Efficacy and Evaluation of Tooth Stain with Various pH Beverages Following Whitening Dentifrice (미백치약 사용에 따른 효과와 다양한 pH 음료의 재착색 평가)

  • Nam, Seoul-Hee;Choi, Jung-Ok
    • Journal of dental hygiene science
    • /
    • v.13 no.2
    • /
    • pp.191-196
    • /
    • 2013
  • The purpose of this study was to evaluate the tooth brightening of whitening dentifrice and to determine the tooth stain level over 20 days depending on beverages that have various pH values after using whitening dentifrice. Thirty teeth were randomly divided into two groups. Group 1 was provided with a whitening dentifrice for 3 minutes and group 2 was treated with a control dentifrice for 3 minutes thrice a day for four weeks. All teeth were photographed using a digital imaging system under a stereomicroscope (magnification, ${\times}10$). After four weeks, the ten teeth were immersed in the tea solution, another of ten teeth were immersed in the orange juice and the other of the teeth were immersed in the coffee solution. Three solutions were renewed each day for the appropriate groups. Stain development was monitored under a stereomicroscope daily over 20 days period by immersion of teeth in a tea, juice, coffee solution at room temperature ($25^{\circ}C$) in individual container. Whitening dentifrice gave a statistically higher value of overall color change as compared to control dentifrice after 21 days (p<0.05). Stain level of whiten tooth immersed in orange juice was the grestest overall color change, but there was not statistically significant difference (p>0.05). On the other hand, stain level of whiten tooth immersed in coffee and green tea showed a statistically significant difference after 15 days and 5 days, respectively (p<0.05). Tooth immersed in green tea was higher negative value than control dentifrice. The tooth using whitening dentifrice was shown to be effectively whiter color than control dentifrice. However, stain level by orange juice, coffee and green tea has a strong staining effect.

Study on the Effect of Magnetized Water in the Precipitation Reaction of Salts and in the Hydration Hardening Speed of Gympsum Plaster (자화수가 염류의 침전반응 및 석고의 가수 경화속도에 미치는 영향에 관한 연구)

  • Jeon, Sang-Il;Kim, Dong-Ryul;Lee, Sung-Hyun;Kim, Dong-Suk;Lee, Suk-Keun
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.1
    • /
    • pp.7-13
    • /
    • 2002
  • Although it has been known that the magnetized water shows different physicochemical properties, the exact nature of the magnetized water is not clearly elucidated yet. We have explored the effect of magnetized water in the precipitation of salts, i.e., $BaSO_4,\;BaCO_3,\;CaCO_3$, and in the hydration hardening of gypsum plaster. The amount of salt precipitation was measured by salt filter assay in water bath, $25^{\circ}C$ and also the hydration hardening speed of gypsum plaster was measured by the Gillmore needle method at room temperature. When the salt ions were interacted with each other in 0.1 M concentration, the precipitation reactions of $BaSO_4,\;BaCO_3$, and $CaCO_3$ increased more in the magnetized water, about 3.6%, 3.8%, and 4.4%, respectively, than in the control water. And the hydration hardening speed of gypsum plaster increased more in the magnetized water than in the control water. These data suggest that the magnetized water, which is supposed to be organized by forming numerous nano/micro clusters, induces the increase of salt precipitation and also accelerates the hydration hardening speed of gypsum plaster.

Surface characteristics and biocompatibility of bioinert nitrides ion plated titanium implant (생불활성 질화물 이온도금된 티타늄 임프란트의 표면특성 및 생체적합성)

  • Chang, Kap-Sung;Kim, Heung-Joong;Park, Joo-Cheol;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.209-231
    • /
    • 1999
  • Even though titanium(Ti) and its alloys are the most used dental implant materials, there are some problems that Ti wears easily and interferes normal osteogenesis due to the metal ions. Ti coated with bioactive ceramics such as hydroxyapatite has also such problems as the exfoliation or resorption of the coated layer, Recent studies on implant materials have been proceeding to improve physical properties of the implant substrate and biocompatibility of the implant surfaces. The purpose of the present study was to examine the physical property and bone tissue compatibility of bioinert nitrides ion plated Ti, Button type specimens(14mm in diameter, 2.32rrun in height) for the abrasion test and cytotoxicity test and thread type implants(3.75mm in diameter, 6mm in length) for the animal experiments were made from Ti(grade 2) and 316LVM stainless steel. Ti specimens were ion plated with TiN, ZrN by the low temperature arc vapor deposition, and the depth profile of the TiN/Ti, ZrN/Ti ion plated surface was examined by Auger Electron Spectroscopy. Three kind of button type specimens .of TiN/Ti, ZrN/Ti and Ti were used for abrasion test, and HEPAlClC7 cells and CCD cells were cultivated for 4 days with the specimens for cytotoxicity test. Thread type implants of TiN/Ti, ZrN/Ti, Ti, 316LVM were implanted on the femur of 6 adult dogs weighing 10kg-13kg. Two dogs were sacrified for histological examination after 45 days and 90 days, and four dogs were sacrified for the removal torque test of the implant') after 90 days. The removal torque force was measured by Autograph (Shimadzu Co., AGS-1000D series, Japan). Abrasion resistance of TiN/Ti was the highest, and that of ZrN/Ti and Ti were followed. The bioinert nitride ion plated Ti had much better abrasion resistance, compared with Ti, In the cytotoxicity test, the number of both cells were increased in all specimens, and there were no significant difference in cytotoxic reaction among all groups (p>0.1), In histological examination, 316LVM showed the soft tissue engagement in interface between the implant and bone, but the other materials after 45 days noted immature new bone formation in the medullary portion along the implant surface, and those after 90 days showed implant support by new bone formation in both the cortical and the medullary portion, The removal torque force of Tilv/Ti showed significantly higher than that of Ti(p(O,05). The difference in removal torque force between TiN/Ti and ZrN/Ti was not significant(p>0.05), and that of 316LVM was lowest among all groups(p<0.05). These results suggest that bioinert nitrides ion plated Ti can resolve the existing problems of Ti and bioactive ceramics, and it may be clinically applicable to human.

  • PDF