• 제목/요약/키워드: oral delivery

검색결과 326건 처리시간 0.025초

Novel dental anesthetic and associated devices: a scoping review

  • Kyung Hyuk Min;Zac Morse
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제24권3호
    • /
    • pp.161-171
    • /
    • 2024
  • The efficient management of pain and discomfort is essential for successful dental treatment and patient compliance. Dental professionals are commonly evaluated for their ability to perform treatment with minimal patient discomfort. Despite advancements in traditional local dental anesthesia techniques, the pain and discomfort associated with injections remain a concern. This scoping review aims to provide a comprehensive overview of the literature on novel dental anesthetics and associated devices designed to alleviate pain and discomfort during dental procedures. The Joanna Briggs Institute and the Preferred Reporting Items for Systematic reviews and Meta-Analyses Extension for Scoping Reviews guidelines were used to prepare the review. Six databases and two sources of gray literature were searched. This review analyzed 107 sources from 1994 to 2023. Local anesthesia devices were grouped into computer-controlled local anesthetic delivery (CCLAD) systems, intraosseous anesthesia (IOA), vibratory stimulation devices, and electronic dental anesthesia (EDA). CCLAD systems, particularly the Wand and Single-Tooth Anesthesia, have been the most researched, with mixed results regarding their effectiveness in reducing pain during needle insertion compared to traditional syringes. However, CCLAD systems often demonstrated efficacy in reducing pain during anesthetic deposition, especially during palatal injections. Limited studies on IOA devices have reported effective pain alleviation. Vibrating devices have shown inconsistent results in terms of pain reduction, with some studies suggesting their primary benefit is during needle insertion rather than during the administration phase. EDA devices are effective in reducing discomfort but have found limited applicability. These findings suggest that the CCLAD systems reduce injection pain and discomfort. However, the evidence for other devices is limited and inconsistent. The development and research of innovative technologies for reducing dental pain and anxiety provides opportunities for interdisciplinary collaboration and improved patient care in dental practice.

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

Rosiglitazone약물을 함유한 PLGA 나노입자 제조 및 분석 (Preparation and Characterization of Rosiglitazone-loaded PLGA Nanoparticles)

  • 신고은;허강무;이용규
    • KSBB Journal
    • /
    • 제23권5호
    • /
    • pp.408-412
    • /
    • 2008
  • 본 연구에서는 당뇨병치료제인 로시글리타존약물를 생분해성 PLGA 나노입자에 봉입시킴으로서 위장흡수율과 물에 대한 용해도를 증가시키기 위한 나노제제 개발에 기반을 두고 있다. 특히 제조조건에 따라 형태 및 크기가 조절가능한 나노입자를 제조하고자 하였고, 실험결과 Emulsion-evaporation방법을 사용하여 100-150 nm 크기의 고른 입자분포를 가진 나노입자를 제조하였다. 다양한 농도의 약물 존재하에서 나노입자를 제조함으로서 1%까지의 약물이 80% 이상의 봉입율로 제조될 수 있음을 확인하였다. 또한 나노입자의 크기는 PVA양을 조절하면서 크기분포를 제어하였다. 36시간 동안의 용출실험 결과 초기 약간의 Burst effect가 있었으나 36시간동안 일정하게 약물이 용출되어 나옴을 확인하였다. 앞으로의 연구를 통해, 고효율의 경구제제용 당뇨병치료제 운반체 개발에 중점을 둘 예정이다.

Relative Bioavailability and Pharmacokinetics of Newly Designed Cyclosporin A Self-microemulsifying Formulation after Single and Multiple Doses to Dogs

  • Yang, Su-Geun;Shin, Hee-Jong
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권2호
    • /
    • pp.111-115
    • /
    • 2009
  • The pharmacokinetics of cyclosporin A (CsA) after single and multiple oral dosing of new CsA self-micro-emulsifying drug delivery system (SMEDDS) in dogs were estimated. A single dose study was performed following a two-way crossover design against six dogs with reference SMEDDS. For a multiple dose study, three dogs were allocated for each drug, and 100 mg of drug was administered daily for 6 days. Whole blood concentration of CsA was analyzed by radio-immunoassay. Both drug showed identical blood concentration profiles in both studies, and no statistical difference was detected in pharmacokinetic parameters. The relative bioavailabilities of test SMEDDS were 91.4% and 89.1%, respectively, in the single dose study and the last day of multiple dose study. Especially, multiple dose study proved the good relationship between C-0/C-2 and AUC for reference SMEDDS, which is an indispensable part of therapeutic drug monitoring. These results suggest newly formulated CsA SMEDDS possibly shows identical pharmacokinetics and pharmacodynamic behaviors in clinical trials.

Pure esophageal atresia. 2 case

  • 정상석;최필조;박권재;방정희;조광조;우종수;정진아
    • 대한기관식도과학회지
    • /
    • 제14권1호
    • /
    • pp.59-64
    • /
    • 2008
  • Pure esophageal atresia without tracheoesophageal fistula is a uncommon form of congenital malformation of the esophagus, which is able to be suspected by fetal ultrasonograpy before delivery and diagnosed definitely by simple chest X-ray and esophagogram immidiately after delivery. We performed delayed primary repair in 2 cases of pure esophageal atresia by using stomach for conduit in one case and colon in the other case. But there were graft failure in the latter case, so reoperation was performed by using stomach. Postoperatively, two patients showed no stenosis and leakage in anastomotic site and were discharged in good oral intake without dysphagia.

  • PDF

디프테리아 백신의 진화와 물리화학적, 분자생물학적, 면역학적 지식의 진보에 따른 새로운 백신의 개발에 관한 고찰연구 (The Evolution and Value of Diphtheria Vaccine)

  • 배경동
    • KSBB Journal
    • /
    • 제26권6호
    • /
    • pp.491-504
    • /
    • 2011
  • This review article provides an overview of the evolution of diphtheria vaccine, its value and its future. Diphtheria is an infectious illness caused by diphtheria toxin produced by pathogenic strains of Corynebacterium diphtheriae. It is characterized by a sore throat with membrane formation due to local tissue necrosis, which can lead to fatal airway obstruction; neural and cardiac damage are other common complications. Diphtheria vaccine was first brought to market in the 1920s, following the discovery that diphtheria toxin can be detoxified using formalin. However, conventional formalin-inactivated toxoid vaccines have some fundamental limitations. Innovative technologies and approaches with the potential to overcome these limitations are discussed in this paper. These include genetic inactivation of diphtheria toxoid, innovative vaccine delivery systems, new adjuvants (both TLR-independent and TLR-dependent adjuvants), and heat- and freeze-stable agents, as well as novel platforms for producing improved conventional vaccine, DNA vaccine, transcutaneous (microneedle-mediated) vaccine, oral vaccine and edible vaccine expressed in transgenic plants. These innovations target improvements in vaccine quality (efficacy, safety, stability and consistency), ease of use and/or thermal stability. Their successful development and use should help to increase global diphtheria vaccine coverage.

핵정(核鐘)에 코팅된 필름층 중에 함유되어 있는 말레인산클로르페니라민의 방출특성 (Dissolution of Chlorpheniramine Mallate (CMP) from Sustained-Release Tablets Containing CPM in the Coated Film Layer)

  • 유제만;심창구;이민화;김신근
    • Journal of Pharmaceutical Investigation
    • /
    • 제20권2호
    • /
    • pp.89-95
    • /
    • 1990
  • Ethylcellulose-PEG 4000 film coated on core tablets was investigated as a potential drug delivery system for the controlled release of chlorpheniramine maleate (CPM). The kinetic analysis of the release data indicated that CPM release followed a diffusion-controlled model, where the quantity released per unit area is proportional to the square root of time. The effect of the film composition, CPM concentration, plasticizer concentration and CPM solubility on the release characteristics were examined. The release rate constant increased as CPM concentration increased. It also increased as the PEG 4000 content in the film increased above 10%(w/w), however, it decreased as the PEG 4000 content increased in the concentration range below 10%(w/w). The release rate constant was not affected by the coated weight on the core tablet. The film-coated tablets which contain CPM only in the coated film layer seemed to be a potential oral drug delivery system for the controlled release of CPM.

  • PDF

백서 설신경 압박손상모델에서 신경성장인자 유전자 주입이 신경재생에 미치는 영향 (EFFECT OF NERVE GROWTH FACTOR GENE INJECTION ON THE NERVE REGENERATION IN RAT LINGUAL NERVE CRUSH-INJURY MODEL)

  • 고은봉;정헌종;안강민;김성민;김윤희;장정원;이종호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제28권5호
    • /
    • pp.375-395
    • /
    • 2006
  • Purpose: Lingual nerve (LN) damage may be caused by either tumor resection or injury such as wisdom tooth extraction, Although autologous nerve graft is sometimes used to repair the damaged nerve, it has the disadvantage of necessity of another operation for nerve harvesting. Moreover, the results of nerve grafting is not satisfactory. The nerve growth factor (NGF) is well-known to play a critical role in peripheral nerve regeneration and its local delivery to the injured nerve has been continuously tried to enhance nerve regeneration. However, its application has limitations like repeated administration due to short half life of 30 minutes and an in vivo delivery model must allow for direct and local delivery. The aim of this study was to construct a well-functioning $rhNGF-{\beta}$ adenovirus for the ultimate development of improved method to promote peripheral nerve regeneration with enhanced and extended secretion of hNGF from the injured nerve by injecting $rhNGF-{\beta}$ gene directly into crush-injured LN in rat model. Materials and Methods: $hNGF-{\beta}$ gene was prepared from fetal brain cDNA library and cloned into E1/E3 deleted adenoviral vector which contains green fluorescence protein (GFP) gene as a reporter. After large scale production and purification of $rhNGF-{\beta}$ adenovirus, transfection efficiency and its expression at various cells (primary cultured Schwann cells, HEK293 cells, Schwann cell lines, NIH3T3 and CRH cells) were evaluated by fluorescent microscopy, RT-PCR, ELISA, immunocytochemistry. Furthermore, the function of rhNGF-beta, which was secreted from various cells infected with $rhNGF-{\beta}$ adenovirus, was evaluated using neuritogenesis of PC-12 cells. For in vivo evaluation of efficacy of $rhNGF-{\beta}$ adenovirus, the LNs of 8-week old rats were exposed and crush-injured with a small hemostat for 10 seconds. After the injury, $rhNGF-{\beta}$ adenovirus($2{\mu}l,\;1.5{\times}10^{11}pfu$) or saline was administered into the crushed site in the experimental (n=24) and the control group (n=24), respectively. Sham operation of another group of rats (n=9) was performed without administration of either saline or adenovirus. The taste recovery and the change of fungiform papilla were studied at 1, 2, 3 and 4 weeks. Each of the 6 animals was tested with different solutions (0.1M NaCl, 0.1M sucrose, 0.01M QHCl, or 0.01M HCl) by two-bottle test paradigm and the number of papilla was counted using SEM picture of tongue dorsum. LN was explored at the same interval as taste study and evaluated electro-physiologically (peak voltage and nerve conduction velocity) and histomorphometrically (axon count, myelin thickness). Results: The recombinant adenovirus vector carrying $rhNGF-{\beta}$ was constructed and confirmed by restriction endonuclease analysis and DNA sequence analysis. GFP expression was observed in 90% of $rhNGF-{\beta}$ adenovirus infected cells compared with uninfected cells. Total mRNA isolated from $rhNGF-{\beta}$ adenovirus infected cells showed strong RT-PCR band, however uninfected or LacZ recombinant adenovirus infected cells did not. NGF quantification by ELISA showed a maximal release of $18865.4{\pm}310.9pg/ml$ NGF at the 4th day and stably continued till 14 days by $rhNGF-{\beta}$ adenovirus infected Schwann cells. PC-12 cells exposed to media with $rhNGF-{\beta}$ adenovirus infected Schwann cell revealed at the same level of neurite-extension as the commercial NGF did. $rhNGF-{\beta}$ adenovirus injected experimental groups in comparison to the control group exhibited different taste preference ratio. Salty, sweet and sour taste preference ratio were significantly different after 2 weeks from the beginning of the experiment, which were similar to the sham group, but not to the control group.

Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading

  • Kim, Seong-Beom;Yun, Pil-Young;Kim, Sang-Yun;Yi, Yang-Jin;Kim, Ji-Yun;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.396-403
    • /
    • 2016
  • PURPOSE. Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS. This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS. All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION. Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading.

방사선조사와 저칼슘식이가 치아형성시 Interleukin-1의 분포에 미치는 영향에 관한 연구 (The Effects of Irradiation and Calcium-deficient Diet on the Expression of Interleukin-1 during Tooth Formation of Rat Molar)

  • 김일중;황의환;이상래
    • Imaging Science in Dentistry
    • /
    • 제30권3호
    • /
    • pp.159-168
    • /
    • 2000
  • Purpose: To elucidate the effects of the irradiation and calcium-deficient diet on expression of interleukin (IL)-1 during tooth formation of rat molar. Materials and Methods: The pregnant three-week-old Spague-Dawley rats were used for the study. The control group was non-irradiation/normal diet group, and the experimental groups were irradiation/normal diet group and irradiation/calcium-deficient diet group. The abdomen of the rats on the 9th day of pregnancy were irradiated with single dose of 350 cGy, The rat pups were sacrificed on the 14th day after delivery and the maxillae tooth germs were taken. The specimen were prepared to make sections for light microscopy, and some of tissue sections were stained immunohistochemically with anti-IL-l antibody. Results: In the irradiation/normal diet group, dental follicle showed fewer blood vessels, mononuclear cells, and fusions of mononuclear cells than in non-irradiation/normal diet group. Alveolar bone showed a few osteoblasts and osteoclasts. Periodontal ligament showed collagen fibers and fibroblasts with irregularity. Weak immunoreactivity for IL-l was shown in dental follicle, alveolar bone, and periodontal ligament. In the irradiation/calcium-deficient diet group, dental follicle showed sparse cellularity. Alveolar bone showed diminished number of osteoblasts. Periodontal ligament showed irregular collagen fibers and atrophy of cementoblasts and fibroblasts. No immunoreactivity for IL-1 was shown in dental follicle, alveolar bone, and periodontal ligament. Conclusion: Irradiation and calcium-deficient diet seems to cause disturbance of the expression of interleukin-l during tooth formation of rat molar.

  • PDF