• 제목/요약/키워드: optimum rib spacing

검색결과 3건 처리시간 0.017초

승원 안전을 고려한 승용차 A-Pillar Trim의 최적 설계 (Optimum Design of A-Pillar Trim for Occupant Protection)

  • 김형곤;강신일
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.99-106
    • /
    • 2001
  • NHTSA has been conducting biomechanical studies to reduce inujuries sustained sustained during automotive collision. Furthermore, NHTSA added the regulation to the FMVSS 201, limiting the equivalent HIC(Head Injury Criterion) value under 1000. In the presont work, a methodology was developed for the optimum design of the A-pillar trim with rib-structures. The design variables for the rib-strucrures were the transverse spacing, the longitudinal spacing, and the thickness. The required sets of the design varibles were decided based on the design of experiments. The head impact simulations were carried out using the LS-DYNA3D, and the HIC(d) values were computed using the resulrs of the head impact simulation. The objective function was constructed using the response surface methed (RSM). When the obtained optimum values were not inside the region of interest, the design proceduers were repeated by changing the region of interest. Finally, an A-pillar trim with rib-structures, which resulred in HIC(d) value under 850 for 15 mph head-trim impact, was developed.

  • PDF

Soil and ribbed concrete slab interface modeling using large shear box and 3D FEM

  • Qian, Jian-Gu;Gao, Qian;Xue, Jian-feng;Chen, Hong-Wei;Huang, Mao-Song
    • Geomechanics and Engineering
    • /
    • 제12권2호
    • /
    • pp.295-312
    • /
    • 2017
  • Cast in situ and grouted concrete helical piles with 150-200 mm diameter half cylindrical ribs have become an economical and effective choice in Shanghai, China for uplift piles in deep soft soils. Though this type of pile has been successful used in practice, the reinforcing mechanism and the contribution of the ribs to the total resistance is not clear, and there is no clear guideline for the design of such piles. To study the inclusion of ribs to the contribution of shear resistance, the shear behaviour between silty sand and concrete slabs with parallel ribs at different spacing and angles were tested in a large direct shear box ($600mm{\times}400mm{\times}200mm$). The front panels of the shear box are detachable to observe the soil deformation after the test. The tests were modelled with three-dimensional finite element method in ABAQUS. It was found that, passive zones can be developed ahead of the ribs to form undulated failure surfaces. The shear resistance and failure mode are affected by the ratio of rib spacing to rib diameter. Based on the shape and continuity of the failure zones at the interface, the failure modes at the interface can be classified as "punching", "local" or "general" shear failure respectively. With the inclusion of the ribs, the pull out resistance can increase up to 17%. The optimum rib spacing to rib diameter ratio was found to be around 7 based on the observed experimental results and the numerical modelling.

전산유체해석을 이용한 다양한 요철 형상에 대한 고압터빈 노즐 냉각유로 최적화 및 냉각 성능 비교 (DESIGN OPTIMIZATION AND PERFORMANCE ANALYSIS OF INTERNAL COOLING PASSAGE WITH VARIOUS TYPE OF RIB TURBULATOR FOR HIGH PRESSURE TURBINE NOZZLE)

  • 이상아;이동호;강영석;이관중;김규홍
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.14-19
    • /
    • 2014
  • This study conducts shape optimization of rib turbulator on the internal cooling passage that has triangular cross-section of high pressure turbine nozzle. During optimization, various types of rib turbulator including angled, V-shaped, A-shaped and angled rib with intersecting rib are considered. Each type of rib turbulator is parameterized with attack angle(s), rib height, spacing ratio and bending/intersecting location. For optimization, Design of Experiment (DOE) and Kriging surrogate model are used to utilize computational resource more efficiently and Genetic Algorithm (GA) is used to search the optimum points. As a result, Pareto front of each type of rib turbulator with friction factor that relates to pressure drop in cooling passage and spatially averaged Nusselt number that relates to heat transfer on the wall is drawn and optimum points on the Pareto front are suggested.