• 제목/요약/키워드: optimum operation

검색결과 1,185건 처리시간 0.028초

연속압입시험의 최적조건 선정을 통한 철강재료의 용접부 잔류응력 평가 (The Evaluation of Residual Stresses in the Welded Joint of Steel Materials by the Optimum Selection of the Advanced Indentation Technique)

  • 유승종;김주현
    • 한국정밀공학회지
    • /
    • 제24권2호
    • /
    • pp.118-126
    • /
    • 2007
  • Most of materials receive forces in use so that the characteristics of materials must be considered in system design to prevent deformation or destruction. Mechanical properties of materials can be expressed as responsible level of material itself under the exterior operation. Main mechanical properties are strength, hardness, ductility and stiffness. Currently, among major measure facilities to measure the mechanical properties, advanced indentation technique has important use in industrial areas due to nondestructive and easy applications for mechanical tensile properties and evaluation of residual stress of materials. This study is to find the optimum experimental condition about residual stress advanced indentation technique for accurate analysis of the welded joint of steel materials through indentation load-depth curve obtained from cruciform specimen experiment. Optimum selection was applied to the welded joint of real steel materials to find out non-equi-biaxial stress state and the results were compared with general residual stress analyzing method fur verification.

차량 노면 진동을 이용한 공진형 선형 발전기 시스템의 강건최적설계 (Robust Optimum Design of Resonance Linear Electric Generator for Vehicle Suspension)

  • 최지현;김진호;박상신;서태원
    • 한국생산제조학회지
    • /
    • 제23권4호
    • /
    • pp.403-407
    • /
    • 2014
  • To use vibration energy to generate electricity, a resonance vertical linear electric generator was applied to the suspension of a vehicle in a previous paper. However, the working conditions, including mass change in the vehicle body related to the cargo on board, number of passengers and the temperature difference caused by the operating environment, can influence the permanent magnet, which is the main component of the electric generator. Therefore, a robust optimum design is required to minimize the influences from the diverse operation conditions and maximize the electromotive force of the electric generator. In this paper, a resonance linear electric generator is introduced. Vibration response analysis to find the input velocity of the electric generator and an electromagnetic transient analysis to apply changes in the performance of the permanent magnet are performed. Finally, the optimum value of each design variable is derived using a Taguchi method.

Neutral Loop Discharge 플라즈마의 전자거동과 최적조건에 관한 기초적 연구 (A Fundamental Study on the Electron Behavior and Optimum Condition for the Formation of a Neutral Loop Discharge Plasma)

  • 성열문;김종경;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권6호
    • /
    • pp.281-287
    • /
    • 2001
  • In order to obtain guidelines for design and operation of a new plasma source by a magnetic neutral loop discharge(NLD), the electron behavior was studied experimentally and numerically. Experimentally, the magnetic field gradient was changed over a wide range, and it was found that there existed an optimum value for efficient plasma production. Analyses of the electron behavior were performed using a model that included effects of a three dimensional electromagnetic field configuration considering the spatial decay of the electric field, and the limitation to the motion of electron caused by the existence of walls and thus electron loss at wall surfaces. These three dimensional factors were found to explain the existence of the optimum magnetic field gradient. It was shown that the L dependence of the plasma production efficiency was firstly decided by the finite decay length of the electric field strength, which was further modified by electron elastic collisions with neutral atoms which drove the electron to walls. The latter effect tends to reduce the optimum value of L.

  • PDF

가변 통기성 의복을 위한 스마트 개폐장치 개발: 양방향 작동 액추에이터 제작을 위한 일방향 형상기억합금 와이어의 최적 직경 및 전압인가 단위시간의 도출 (Development of Smart Switchgear for Versatile Ventilation Garments: Optimum Diameter and Voltage Application Unit Time of One-way Shape Memory Alloy Wire for a Bi-directional Actuator)

  • 김상구;김민성;유신정
    • 감성과학
    • /
    • 제21권2호
    • /
    • pp.137-144
    • /
    • 2018
  • 본 연구에서는 가변 통기성 스마트 의류의 제작을 위해 필요한 형상기억합금 액추에이터의 작동 조건을 파악하였다. 의복의 개방, 폐쇄와 같은 양방향 작동 시 형태 변형 시에만 전력을 소모하는 저전력 소모 액추에이터 개발을 위해 복수 채널의 일방향 형상기억합금을 이용하여 스위치로 작동되는 액추에이터를 설계하였으며 가장 효율적으로 작동할 수 있는 와이어의 직경과 전압인가 단위시간을 도출하였다. 선행연구 결과 도출된 양방향 작동이 가능한 일방향 형상기억합금의 직경 범위 내에서 Arduino 스위치를 제작하여 3.7V 전압인가 시 변화량을 분석한 결과 $0.4{\Phi}$의 액추에이터가 가장 적합한 것으로 나타났다. $0.4{\Phi}$ 형상기억합금와이어를 사용한 양방향작동 액추에이터의 개방, 폐쇄에 필요한 최적전압인가 시간을 도출하기 위해 액추에이터의 최대개방, 최소폐쇄 도달 전압인가 시간으로부터 50ms씩 감소, 증가 시키며 냉각 후 액추에이터의 내경을 비교하는 방식으로 측정한 결과 개방 동작에 필요한 최적 전압인가 단위시간은 4,100ms로 나타났다. 각 채널간의 발열에 의한 간섭을 최소화하기 위한 양방향간 작동 시 필요 딜레이 분석을 위해 상온에서 형상기억합금에 최적 전압입가 시간인 4.1초 동안 전원을 공급하고 가열 후 냉각까지의 과정을 열화상카메라로 촬영하여 형상기억합금 와이의 온도가 냉각시의 상변태온 이하로 하강하는 시점을 파악한 결과, 액추에이터의 양방향간 작동 딜레이는 1.8초 이상이 확보되어야 함을 파악할 수 있었다.

Y 정수장 세라믹막 여과공정 최적 운영인자 평가 (The Study on Optimum Operation Conditions of Ceramic MF Membrane Process in Y Water Treatment Plant)

  • 유상준;안효원;박성한;임재림;홍성철;이병인
    • 멤브레인
    • /
    • 제24권3호
    • /
    • pp.201-212
    • /
    • 2014
  • 본 연구는 국내 최초로 도입된 Y 정수장의 세라믹막 고도정수처리를 위한 최적 운영 인자를 도출하기 위하여 수행되었다. 경제성과 수질조건을 만족하면서도 세라믹막 여과성능을 지속 유지할 수 있는 최적 운영조건을 도출한 결과, Y 정수장의 평상시 수질 조건에서 막역세척으로 인한 배출수 발생량을 최소화시키면서도 막여과성능을 유지할 수 있는 최적 여과지속시간(역세척 주기)은 시설용량($16,000m^3$/일) 기준 시 4.0시간으로 조사되었다. 또한 화학세척(CIP)에 따른 막차압 회복력을 조사한 결과, 구연산을 이용한 산세정을 통하여 철, 망간, 알루미늄 등의 막 파울링을 일으키는 무기오염물질은 제거되지만 막회복률은 낮았다. 반면 차아염소산나트륨을 사용한 알칼리 세정을 통해서는 막 운영 초기 막차압으로 회복되는 것으로 나타났다. 막차압을 발생시키는 파울링 주요 원인물질은 친수성 고분자 유기오염물인 polysaccharides로 조사되었으며, 화학세척(CIP)시 막성능 회복률은 세척약품 온도에 의한 영향이 매우 크며, 온도가 높은수록 막성능 회복률이 향상되는 것으로 조사되었다.

직교표에 의한 주물사 배합조건의 개선 (A Study on the Improvement for Mixing Conditions of Foundry Sand by Orthogonal Array)

  • 이상도;권영일
    • 산업경영시스템학회지
    • /
    • 제4권5호
    • /
    • pp.1-10
    • /
    • 1981
  • The purpose of this study is to cut down cost of production and improve the productivity of industry through quality improvement of castings and reduction of defectives by applying the experimental design to the foundry sand mixing operation done at molding department in the foundry. Among the related foundry sand mixing factors which have an effect on casting the experiment of which factors have a dominant effect on quality improvement was performed between two different levels by means of "$2^n$ type orthogonal array." The results cail be summarized as follows ; (1) The optimum conditions per each foundry sand mixing between two different levels proved to be such as $A_2$(used sand) : 24 unit (172.8kg), $B_2$(unused sand ) : 2 unit (15.0kg), $C_2$(binder) : 2.5 unit (4.4kg). $D_2$(addition agent) : 1 unit(1.4kg) and $F_1$(moisture) : 7.4%(14.6kg). (2) As a result of the application of experimental design, the fraction defective during the foundry sand mixing operation turned out to be reduced front 6.6% to 2.04%. (3) For the purpose of cost-down, It was found that the optimum level decision of foundry sand mixing for various castings is required to be made by means of experimental design.al design.

  • PDF

상수관망에서 서지 릴리프밸브의 최적 설계 방법론 (Methodology for optimum design of surge relief valve in water distribution system)

  • 김현준;허지성;김건지;백다원;김상현
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.1-6
    • /
    • 2017
  • Surge pressure is created by rapid change of flow rate due to operation of hydraulic component or accident of pipeline. Proper control of surge pressure in distribution system is important because it can damage pipeline and may have the potential to degrade water quality by pipe leakage due to surge pressure. Surge relief valve(SRV) is one of the most widely used devices and it is important to determine proper parameters for SRV's installation and operation. In this research, determining optimum parameters affecting performance of the SRV were investigated. We proposed the methodology for finding combination of parameters for best performance of the SRV. Therefore, the objective function for evaluate fitness of candidate parameters and surge pressure simulation software was developed to validate proposed parameters for SRV. The developed software was integrated into genetic algorithm(GA) to find best combination of parameters.

SNR Analysis for Practical Electro-Optical Camera System

  • Kim Youngsun;Kong Jong-Pil;Heo Haeng-Pal;Park Jong-Euk;Chang Young-Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.633-636
    • /
    • 2005
  • An electro-optical camera system consists of many subsystems such as the optics, the detector, and the electronics and so on. They may create variations in the processed image that were not present original scene. The performance analysis of the electro-optical camera system is a mathematical construct that provides an optimum design through appropriate trade off analysis. The SNR(Signal to Noise Ratio) is one of the most important performance for the electro-optical camera system. The SNR analysis shown in this paper is performed based on the practical high resolution satellite camera design. For the purpose of the practical camera design, the analysis assumes that the defined radiance, which is calculated for the Korean peninsula, reached directly to the telescope entrance. In addition, the actual operation concept such as integration time and the normal operation altitude is assumed. This paper compares the SNR analysis results according to the various camera characteristics such as the optics, the detector, and the camera electronics. In detail, the optical characteristics can be split into the focal length, F#, transmittance, and so on. And the system responsivity, the quantum efficiency, the TDI stages, the quantization noise and the analogue noise can be used for the detector and the camera electronics characteristics. Finally this paper suggests the optimum design to apply the practical electro-optical system.

  • PDF

Hybrid thermal seasonal storage and solar assisted geothermal heat pump systems for greenhouses

  • Ataei, Abtin;Hemmatabady, Hoofar;Nobakht, Seyed Yahya
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.87-106
    • /
    • 2016
  • In this research, optimum design of the combined solar collector, geothermal heat pump and thermal seasonal storage system for heating and cooling a sample greenhouse is studied. In order to optimize the system from technical point of view some new control strategies and functions resulting from important TRNSYS output diagrams are presented. Temperatures of ground, rock bed storage, outlet ground heat exchanger fluid and entering fluid to the evaporator specify our strategies. Optimal heat storage is done with maximum efficiency and minimum loss. Mean seasonal heating and cooling COPs of 4.92 and 7.14 are achieved in series mode as there is no need to start the heat pump sometimes. Furthermore, optimal parallel operation of the storage and the heat pump is studied by applying the same control strategies. Although the aforementioned system has higher mean seasonal heating and cooling COPs (4.96 and 7.18 respectively) and lower initial cost, it requires higher amounts of auxiliary energy either. Soil temperature around ground heat exchanger will also increase up to $1.5^{\circ}C$ after 2 years of operation as a result of seasonal storage. At the end, the optimum combined system is chosen by trade-off between technical and economic issues.

회수수가 응집공정의 오염물질 제거 및 입자특성에 미치는 영향 (Effects of Recycled Washwater on Pollutant Removal and Particle Characteristics during Coagulation)

  • 문병현;김승현;박미선;이향인;이강춘
    • 한국환경과학회지
    • /
    • 제11권9호
    • /
    • pp.955-960
    • /
    • 2002
  • The recycled washwater, which has different water quality and is produced about 5 to 20% of the total water volume treated, affects the unit operation of water treatment, especially coagulation process. However, the effects of recycled washwater on unit operation of water treatment have not been fully investigated. In this study, effects of recycled washwater on coagulation process were investigated to find the optimum coagulation condition by analyzing turbidity, $UV_{254}$, TOC removal efficiencies. In addition, effects of recycled washwater on residual Al after coagulation were studied by analyzing soluble and particulate Al. The size distribution and fractal dimension of coagulated also analyzed. The recycled washwater was lower pH than the raw water. And the recycled washwater had higher $UV_{254}$, TOC and residual Al concentration than the raw water. Residual Al concentration of recycled washwater was about 50 times higher than that of raw water. Optimum coagulant dosages on the blending recycled washwater and the raw water for turbidity, $UV_{254}$ and Al removal were lower than that on the raw water. However, TOC removal increased by increasing coagulant dosage. The size and fractal dimension of coagulated particle produced in the blending recycled washwater were larger, which imply faster settling velocity, than those produced in the raw water only.