• Title/Summary/Keyword: optimum measurement

Search Result 703, Processing Time 0.032 seconds

Thrust Performance and Plasma Acceleration Process of Hall Thrusters

  • Tahara, Hirokazu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.262-270
    • /
    • 2004
  • Basic experiments were carried out using the THT-IV low-power Hall thruster to examine the influences of magnetic field shape and strength, and acceleration channel length on thruster performance and to establish guidelines for design of high-performance Hall thrusters. Thrusts were measured with varying magnetic field and channel structure. Exhaust plasma diagnostic measurement was also made to evaluate plume divergent angles and voltage utilization efficiencies. Ion current spatial profiles were measured with a Faraday cup, and ion energy distribution functions were estimated from data with a retarding potential analyzer. The thruster was stably operated with a highest performance under an optimum acceleration channel length of 20 mm and an optimum magnetic field with a maximum strength of about 150 Gauss near the channel exit and with some shape considering ion acceleration directions. Accordingly, an optimum magnetic field and channel structure is considered to exist under an operational condition, related to inner physical phenomena of plasma production, ion acceleration and exhaust plasma feature. A new Hall thruster was designed with basic research data of the THT-IV thruster. With the thruster with many considerations, long stable operations were achieved. In all experiments at 200-400 V with 1.5-3 mg/s, the thrust and the specific impulse ranged from 15 to 70 mN and from 1100 to 2300 see, respectively, in a low electric power range of 300~1300 W. The thrust efficiency reached 55 %. Hence, a large map of the thruster performance was successfully made. The thermal characteristics were also examined with data of both measured and calculated temperatures in the thruster body. Thermally safe conditions were achieved with all input powers.

  • PDF

Thermal Characteristics of the Optimal Design on 15W COB LED Down Light Heat Sink (주거용 15W COB LED 다운라이트 방열판 최적설계에 따른 열적 특성 분석 및 평가)

  • Kwon, Jae-Hyun;Park, Keon-Jun;Kim, Tae-Hyung;Kim, Yong-Kab
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.401-407
    • /
    • 2014
  • There are increasing interests in COB (Chip On Board) that densely arranged many LED chips on one board in order to solve the heat issue. There are many problems being on the rise: the lifespan decreases as the temperature of LED devices increases; Red Shift phenomenon, in which wave length of spectral line moves from original wave length to long wave length, occurs; and optical power decreases as $T_j$ increases. In order to resolve such problems, this study selected the optimum thickness and length of Fin, planned the second Heat sink that is optimum for COB LED with 15W, and analyzed thermal mode by Solid Works Flow Simulation through 15W COB packaging with the planned Heat sink. 15W COB down-light Heat sink that is produced based on this analysis was utilized to analyze thermal mode through contact thermometer and electrical properties through Kelthley 2430.

A Rapid Method for the Measurement of $^{222}Rn$ in Groundwater and Hot Spring Water using Ultra Low-Level Liquid Scintillation Counter and Pulse Shape Analysis (극저준위 액체섬광계수기와 파형분석법을 이용한 지하수 및 온천수중 $^{222}Rn$의 신속측정법)

  • Kim, Chang-Kyu;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.103-115
    • /
    • 1995
  • For the determination of $^{222}Rn$ in water by a very simple and time saving liquid scintillation counting method that does not require any chemical separation, an optimum analytical condition has been investigated. The optimum pulse shape analysis(PSA) level for the measurement of $^{222}Rn$ using LKB 1220 Quantulus liquid scintillation counter was 110 for Optiphase HiSafe3 cocktail and 90 for toluene-based cocktail. The counting efficiencies of $^{222}Rn$ in the window covering u spectra using Optiphase HiSafe3 cocktail were 282.2% for glass vial and 271.6% for Teflon vial, whereas the counting efficiencies in toluene-based cocktail were 262.3% and 247.5% for glass and Teflon vials, respectively. The minimum detectable activity(MDA) in the u window for a 60-min measurement with a Teflon vial using Optiphase HiSafe3 cocktail was $0.30Bq/{\iota}$. The analytical method studied from this work was also applied to the determination of $^{222}Rn$ in some groundwater and hot spring water samples.

  • PDF

The Evaluation of White Water Sedimentation Efficiency in Settling Tank by the Addition of Flocculents (응집제 첨가에 의한 침전조의 백수침전 효율 평가)

  • Kim Hyoung Jin;An Jung Song;Yoo Sung Ho
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.4 s.107
    • /
    • pp.67-76
    • /
    • 2004
  • Because paper industry spends lots amount of water, the recycling of water is very important in economical as well as environmental aspects. In order to optimize the process water recycling system, the efficiency of unit operation for water circulation, such as save-all system, CDS and settling tank, plays an important role in. In this study, the sedimentation efficiency of process water was evaluated by SS measurement with the different amounts of flocculent addition. 3 different kinds of process water were collected from fine paper mill, and applied in laboratory sedimentation equipment for the measurement of settling efficiency of SS materials. The addition amounts of alum and PAC were resulted in optimum efficiency of sediments in the condition of 100 ppm of alum and 500 ppm of PAC respectively. In the comparison of sedimentation efficiency between alum and PAC, alum showed more economical and efficient results. The SS of spill water and the particle size of suspended materials treated by alum flocculents were below 50 ppm and about 1 $\mu$m. It would be considered that the spill water can be substituted to superclear water grade.

Radiation Measurement of a Operational CANDU Reactor Fuel Handling Machine using Semiconductor Sensors (ICCAS 2003)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1220-1224
    • /
    • 2003
  • In this paper, we measured the radiation dose of a fuel handling machine of the CANDU type Wolsong nuclear reactor directly during operation, in spite of the high radiation level. In this paper we will describe the sensor development, measurement techniques, and results of our study. For this study, we used specially developed semiconductor sensors and matching dosimetry techniques for the mixed radiation field. MOSFET dosimeters with a thin oxide, that are tuned to a high dose, were used to measure the ionizing radiation dose. Silicon diode dosimeters with an optimum area to thickness ratio were used for the radiation damage measurements. The sensors are able to distinguish neutrons from gamma/X-rays. To measure the radiation dose, electronic sensor modules were installed on two locations of the fuel handling machine. The measurements were performed throughout one reactor maintenance cycle. The resultant annual cumulative dose of gamma/X-rays on the two spots of the fuel handling machine were 18.47 Mrad and 76.50 Mrad, and those of the neutrons were 17.51 krad and 60.67 krad. The measured radiation level is high enough to degrade certain cable insulation materials that may result in electrical insulation failure.

  • PDF

Study on the Optimizing Ultrasonic Cell for Depth Measurement of Crude Oil (원유 깊이 측정을 위한 초전도셀 최적화에 관한 연구)

  • Oh, Kyutae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.1
    • /
    • pp.152-156
    • /
    • 2017
  • Until now, most of the studies related to the ultrasonic sensor was in the water or the air. This study is for ultrasonic sensor in crude oil. because the ultrasonic cell use high voltage, it can cause an explosion. So, in crude oil, it did not use an ultrasonic sensor. This is the study of the ultrasonic sensor that generates ultrasonic waves while preventing explosion. Through this study, when trasmit ultrasonic in the crude oil, it found the most adaptive diameter, thickness, transmit frequency of ultrasonic cell to measure the depth of the crude oil and sludge. In conclusion, when a 200kHz frequency is generated by applying a voltage of 24V to the ultrasonic cell, the optimum diameter of ultrasonic cell is 26~28mm, the thickness of ultrasonic cell is 9mm.

The NO$_2$ gas detection characteristics of the DDilithium phthalocyanine(Li$_2$Pc) LB Film depending on the Temperatures (Dilithium phthalocyanine(Li$_2$Pc) LB막의 온도에 따른 NO$_2$ 가스 탐지 특성에 관한 연구)

  • 조형근;김태완;김정수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.31-34
    • /
    • 1995
  • The NO$_2$ gas-deteotion characteristics were investigated using the functional organic Langmuir-Blodgett(LB) files of Dilithium phthalocyanines(Li$_2$Pc). The optimum conditions for a film deposition were obtained through a study of $\pi$-A isotherms, and the deposited film status was confirmed by the ellipsometry measurements. A propel number of layers for the gas-detection was proved to be 9 layers from a measurement of a measurement of change in the electrical conductivities when the films were exposed to the 200 ppm of the NO$_2$ gases. A response time, recovery time, and reproducibility were also studied. A proper temperature which was able to activate gas interaction between NO$_2$ gases and Li$_2$Pc LB films was around 150$^{\circ}C$ judging from the electrical conductivities in a temperature range of 20 to 200$^{\circ}C$. It was found that at 150\ulcorner there are increments of electrical conductivities by 65 tines, 30 seconds of response time and 60 seconds of recovery tine when the filmswere exposed to the gasses.

  • PDF

A study on the measurement and characterization of tubulent flow inside an engine cylinder (엔진 실린더내 난류유동 측정과 정량화방법에 관한 연구)

  • 강건용;엄종호;김용선
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.39-47
    • /
    • 1992
  • The engine combustion is one of the most important process affecting performance and emissions. One effective way to improve the engine combustion is to control motion of the charge inside a cylinder by means of optimum induction system design, because the flame speed is mainly determined by the turbulence in a gasoline engine. This paper describes the measurement and characterization of mean velocity and turbulence intensity inside the cylinder of a 4-valve gasoline engine using laser Doppler velocimeter(LDV) under motoring(non-firing) conditions. Since the measured LDV data in each cycle show small cycle variation during compression stroke in the tested engine, the mean velocity and turbulence intensity are calculated by ensemble averaging method neglecting cycle variation effects. In the ensemble averaging method, the effects of the calculation window, in which velocities are assumed as the same crank angle, on mean velocity and turbulence intensity are fully investigated. In addition, the effects of measuring point on the flow characteristics are studied. With large calculation window, the mean velocity is shown to be less sensitive with respect to crank angle and turbulence intensity decrease in its absolute amplitude. When the piston approch to the top dead center of compression, the turbulence intensity is found to be homogeneous in the cylinder.

  • PDF

Optimal design of dual magnetic float type level gauge to detect a specific level (특정 레벨을 검출하기 위한 2단 Magnetic Float 타입 레벨 게이지의 최적 설계에 관한 연구)

  • Kim, Dong-Sok;Han, Jae-Man;Park, Gwan-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.308-316
    • /
    • 2008
  • For the measurement of liquid level in ship's cargo tank, ballast tank, fuel oil tank and fresh water tank, several types of gauge meter are used such as tubular type, magnetic float type, reflex type transparent type and welding pad type. Among them, magnetic float type gauge meter is environmental friendly device because it is free of power source and maintenance. The main obstacle of the device is relatively large error bound. In this paper, finite element method is used to design and analysis of the magnetic float type gauge meter. The operation of reed switch according to the magnetic field has been successfully described and agreed well with experimental measurement. The optimum geometry with combination of permanent magnet and reed switches are designed to achieve 98 % accuracy of fluid level.

The Characterization of Interfaces between ZnO Thin Films and Metal Electrodes (ZnO 박막과 금속전극과의 계면특성조사)

  • 박성순;임원택;이창효
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.3
    • /
    • pp.201-207
    • /
    • 1998
  • We have investigated about interface characteristics between ZnO thin films and metal electrodes when ZnO and metal electrodes were fabricated as piezoelectric vibrators. At this, ZnO thin films were deposited by rf reactive magnetron sputtering method. After fabricating piezoelectric vibrator of Cr/ZnO/Cr structure with optimum condition, we analyse interface characteristics between ZnO thin films and metal electrodes by I-V measurement. AES depth profile, SEM and C-V measurement. From these measurements we found that ZnO piezoelectric vibrators showed good property when they fabricated as Cr/$SiO_2$/ZnO/Cr structure. And we could confirm these things by driving, and measuring vibration displacement of piezoelectric vibrator with $SiO_2$diffusion barrier.

  • PDF