• Title/Summary/Keyword: optimal thresholds

Search Result 90, Processing Time 0.022 seconds

Improving Weak Classifiers by Using Discriminant Function in Selecting Threshold Values (판별 함수를 이용한 문턱치 선정에 의한 약분류기 개선)

  • Shyam, Adhikari;Yoo, Hyeon-Joong;Kim, Hyong-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.12
    • /
    • pp.84-90
    • /
    • 2010
  • In this paper, we propose a quadratic discriminant analysis based approach for improving the discriminating strength of weak classifiers based on simple Haar-like features that were used in the Viola-Jones object detection framework. Viola and Jones built a strong classifier using a boosted ensemble of weak classifiers. However, their single threshold (or decision boundary) based weak classifier is sub-optimal and too weak for efficient discrimination between object class and background. A quadratic discriminant analysis based approach is presented which leads to hyper-quadric boundary between the object class and background class, thus realizing multiple thresholds based weak classifiers. Experiments carried out for car detection using 1000 positive and 3000 negative images for training, and 500 positive and 500 negative images for testing show that our method yields higher classification performance with fewer classifiers than single threshold based weak classifiers.

Combined Application of Data Imbalance Reduction Techniques Using Genetic Algorithm (유전자 알고리즘을 활용한 데이터 불균형 해소 기법의 조합적 활용)

  • Jang, Young-Sik;Kim, Jong-Woo;Hur, Joon
    • Journal of Intelligence and Information Systems
    • /
    • v.14 no.3
    • /
    • pp.133-154
    • /
    • 2008
  • The data imbalance problem which can be uncounted in data mining classification problems typically means that there are more or less instances in a class than those in other classes. In order to solve the data imbalance problem, there has been proposed a number of techniques based on re-sampling with replacement, adjusting decision thresholds, and adjusting the cost of the different classes. In this paper, we study the feasibility of the combination usage of the techniques previously proposed to deal with the data imbalance problem, and suggest a combination method using genetic algorithm to find the optimal combination ratio of the techniques. To improve the prediction accuracy of a minority class, we determine the combination ratio based on the F-value of the minority class as the fitness function of genetic algorithm. To compare the performance with those of single techniques and the matrix-style combination of random percentage, we performed experiments using four public datasets which has been generally used to compare the performance of methods for the data imbalance problem. From the results of experiments, we can find the usefulness of the proposed method.

  • PDF

Cost Ratios for Cost and ROC Curves (비용곡선과 ROC곡선에서의 비용비율)

  • Hong, Chong-Sun;Yoo, Hyun-Sang
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.6
    • /
    • pp.755-765
    • /
    • 2010
  • For classification problems on mixture distribution, a threshold based on cost functions is optimal from the viewpoint of a minimum expected cost. Assuming that there is no cost information, we propose cost ratios in the expected cost corresponding to thresholds where the total accuracy and the true rate are maximized to explain the relation of these cost ratios minimizing the expected cost. Other cost ratios are also proposed by comparing the normalized expected costs when classification accuracy is maximized. The values of these cost ratios are located between two cost ratios for the expected costs based on classification accuracies, and converge to that of the minimum expected cost. This work suggests two cost ratios: one is minimized by the expected cost and the normalized expected cost, and the other in the expected cost and the normalized expected cost functions that are maximized classification accuracies. We discuss their compatibility based on the relation of these cost ratios.

Development of a New Prediction Alarm Algorithm Applicable to Pumped Storage Power Plant (양수발전 설비에 적용 가능한 새로운 고장 예측경보 알고리즘 개발)

  • Dae-Yeon Lee;Soo-Yong Park;Dong-Hyung Lee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.2
    • /
    • pp.133-142
    • /
    • 2023
  • The large process plant is currently implementing predictive maintenance technology to transition from the traditional Time-Based Maintenance (TBM) approach to the Condition-Based Maintenance (CBM) approach in order to improve equipment maintenance and productivity. The traditional techniques for predictive maintenance involved managing upper/lower thresholds (Set-Point) of equipment signals or identifying anomalies through control charts. Recently, with the development of techniques for big analysis, machine learning-based AAKR (Auto-Associative Kernel Regression) and deep learning-based VAE (Variation Auto-Encoder) techniques are being actively applied for predictive maintenance. However, this predictive maintenance techniques is only effective during steady-state operation of plant equipment, and it is difficult to apply them during start-up and shutdown periods when rises or falls. In addition, unlike processes such as nuclear and thermal power plants, which operate for hundreds of days after a single start-up, because the pumped power plant involves repeated start-ups and shutdowns 4-5 times a day, it is needed the prediction and alarm algorithm suitable for its characteristics. In this study, we aim to propose an approach to apply the optimal predictive alarm algorithm that is suitable for the characteristics of Pumped Storage Power Plant(PSPP) facilities to the system by analyzing the predictive maintenance techniques used in existing nuclear and coal power plants.

Serum Eosinophilic Cationic Protein as a Useful Noninvasive Marker of Eosinophilic Gastrointestinal Disease in Children

  • Hae Ryung Kim;Youie Kim;Jin Soo Moon;Jae Sung Ko;Hye Ran Yang
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.2
    • /
    • pp.79-87
    • /
    • 2024
  • Purpose: Recently, the prevalence of eosinophilic gastrointestinal disease (EGID) has shown an increasing trend worldwide. As the diagnosis of EGID requires invasive endoscopy with biopsy, noninvasive markers for detecting EGID in suspected patients, particularly children, are urgently needed. Therefore, this study aimed to evaluate the diagnostic accuracy of serum eosinophil cationic protein (ECP) beyond peripheral eosinophil counts in pediatric patients with EGID. Methods: Overall, 156 children diagnosed with EGID were enrolled and 150 children with functional abdominal pain disorder (FAPD) were recruited as controls. All participants underwent endoscopic biopsy in each segment of the gastrointestinal (GI) tract and serum ECP measurement, as well as peripheral eosinophil percent and absolute eosinophil count. Results: Comparing EGID (n=156) with FAPD (n=150) patients, serum ECP levels were significantly higher in pediatric patients with EGID than in those with FAPD (25.8±28.6 ㎍/L vs. 19.5±21.0 ㎍/L, p=0.007), while there was no significant difference in peripheral eosinophil percent and absolute eosinophil counts between the two groups. Serum ECP levels were correlated with peripheral eosinophil percent (r=0.593, p<0.001) and the absolute eosinophil count (r=0.660, p<0.001). The optimal cutoff value of serum ECP for pediatric EGID was 10.5 ㎍/mL, with a sensitivity of 69.9% and a specificity of 43.4% with an area under the receiver operating characteristic curve of 0.562. Conclusion: The combination of serum ECP levels and peripheral eosinophil counts, when employed with appropriated thresholds, could serve as a valuable noninvasive biomarker to distinguish between EGID and FAPD in pediatric patients manifesting GI symptoms.

Semi-Quantitative Analysis for Determining the Optimal Threshold Value on CT to Measure the Solid Portion of Pulmonary Subsolid Nodules (폐의 아고형결절에서 침습적 병소를 검출하기 위한 반-정량 분석을 통한 최적의 CT 임계 값 결정)

  • Sunyong Lee;Da Hyun Lee;Jae Ho Lee;Sungsoo Lee;Kyunghwa Han;Chul Hwan Park;Tae Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.670-681
    • /
    • 2021
  • Purpose This study aimed to investigate the optimal threshold value in Hounsfield units (HU) on CT to detect the solid components of pulmonary subsolid nodules using pathologic invasive foci as reference. Materials and Methods Thin-section non-enhanced chest CT scans of 25 patients with pathologically confirmed minimally invasive adenocarcinoma were retrospectively reviewed. On CT images, the solid portion was defined as the area with higher attenuation than various HU thresholds ranging from -600 to -100 HU in 50-HU intervals. The solid portion was measured as the largest diameter on axial images and as the maximum diameter on multiplanar reconstruction images. A linear mixed model was used to evaluate bias in each threshold by using the pathological size of invasive foci as reference. Results At a threshold of -400 HU, the biases were lowest between the largest/maximum diameter of the solid portion of subsolid nodule and the size of invasive foci of the pathological specimen, with 0.388 and -0.0176, respectively. They showed insignificant difference (p = 0.2682, p = 0.963, respectively) at a threshold of -400 HU. Conclusion For quantitative analysis, -400 HU may be the optimal threshold to define the solid portion of subsolid nodules as a surrogate marker of invasive foci.

Design of the control Algorithm for Improvement of the Convenience the Active-type Walking Aid (전동 보행보조기의 편의성 향상을 위한 제어기 설계)

  • Lee, D.K.;Kong, J.S.;Goh, M.S.;Kang, S.J.;Lee, S.M.;Lee, E.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.17-25
    • /
    • 2011
  • This paper aims to find the optimal control gain for enhancing the convenience of electric walking frames and design a control algorithm. With the recent advances in medical technology, there has been a rapid increase in the aging population and a variety of mobile walking frames have been developed for improvement of the quality of life. However, the manual walking frames of such mobile aids don't have any electric motor which helps facilitate elderly users' walking and thus are not efficient enough for the old people of weak strength to use especially when moving on uneven surfaces such as slopes or thresholds. The types of electric walking frames have been developed to overcome such inefficiency. Electric walking frames require users' control operations for motor driving unlike manual frames. Therefore, when they are not properly handled, it causes considerable inconvenience to their users. The present study compared the electric walking frames with manual ones in terms of operational convenience and attempted to improve the user convenience of walking frames varying the control value for user convenience based on certain standards. This paper presented a haptic sensor designed to recognize the will to walk and measure the degree of convenience and proposed a control algorithm for improvement of convenience. For user convenience, this paper evaluated the relative convenience of walking frames in view of changing differences between the center of vehicle (COV) and the center of position (COP). With the employment of an electric walking frame and a new measuring method, all the processes were experimentally tested and validated.

Effect of Building Generalization in a Lattice Cell Form on the Spatial Connectivity of Overland Storm Waterways in an Urban Residential Area (격자형 건물 일반화가 도시 주거지 빗물 유출경로의 연속성에 미치는 영향)

  • JEON, Ka-Young;HA, Sung-Ryong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.1
    • /
    • pp.137-151
    • /
    • 2017
  • The space between urban buildings becomes a waterway during rain events and requires a boundary condition in numerical calculations on grids to separate overland storm flows from building areas. Minimization of the building data distortion as a boundary condition is a necessary step for generating accurate calculation results. A building generalization is used to reduce the distortion of building shapes and areas during a raster conversion. The objective of this study was to provide the appropriate threshold value for building generalization and grid size in a numerical calculation. The impact of building generation on the connectivity of urban storm waterways were analyzed for a general residential area. The building generalization threshold value and the grid size for numerical analysis were selected as the independent variables for analysis, and the number and area of sinks were used as the dependent variables. The values for the building generalization threshold and grid size were taken as the optimal values to maximize the building area and minimize the sink area. With a 3 m generalization threshold, sets of $5{\times}5m$ to $10{\times}10m$ caused 5% less building area and 94.4% more sink area compared to the original values. Two sites representing general residential area types 2 and 3 were used to verify building generalization thresholds for improving the connectivity of storm waterways. It is clear that the recommended values are effective for reducing the distortion in both building and sink areas.

A Study on the Image Change Using Twinkle Artifact Images and Phantom according to Calcification-Inducing Environment in Breast Ultrasonography (유방 초음파 검사에서 석회화 유발 환경에 따른 반짝 허상과 팸텀을 활용한 영상 변화에 관한 연구)

  • Cheol-Min Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.751-759
    • /
    • 2023
  • Breast ultrasonography is difficult to image in fatty breasts and to find micro-calcification, but the discovery of micro-calcification is very important for breast cancer screening. Among the color Doppler artifact of ultrasound, twinkle artifact mainly occur on strong reflectors such as stones or calcification in images, and evaluation methods using them are clinically being used. In this study, we are conducting experiments on the color Doppler settings of ultrasound equipment, such as repetition frequency, ensemble, persist, wall filtering, smoothing, linear density, and dissociation value, by producing a breast simulation phantom using the largest amount of calcium phosphate among breast implants. The purpose of this study was to improve the contrast of twinkle artifact in breast ultrasound examinations and to maximize their use in clinical practice. As a result, the pulse repetition frequency occurred in the range of 3.6 kHz to 7.2 kHz, and did not occur above 10.5 kHz. For ensembles, twinkle artifact occurred in all sizes of calcification under low conditions, and in threshold settings, the twinkle artifact increased slightly only under 80 to 100 conditions, and did not occur in 1 mm size calcification. Persist, wall filter, smoothing, and line density settings did not have much meaning in the setting variable because conditions did not increase by condition, and pulse repetition frequency, ensemble, and thresholds had the greatest impact on the twinkling artifact image. This study is expected to help examiners select optimal conditions to effectively increase twinkle artifact by adjusting color Doppler settings.

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF