• 제목/요약/키워드: optimal stiffness

검색결과 497건 처리시간 0.031초

퇴행성 요추부 척추관 협착증 치료를 위한 극돌기간 고정기구의 설계 및 생체역학적 분석 (Design of the Interspinous Process Fixator Using Biomechanical Analysis for the Treament of Degenerative Lumbar Spinal Stenosis)

  • 허순;손권;이성재;문병영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1963-1966
    • /
    • 2005
  • Degenerative lumbar spinal stenosis(DLSS) is a disease inducing low back pain, leg pain, convulsion, numbness, and neurogenic claudication from compression of nerve root. Intervertebra fixation was reported to increase the degenerative of neighbor region after treatment. Recently, a new surgical technique of inserting a fixator between interspinous processes has been introduced. The purpose of this study is to design of the interspinous process fixator with flexibility to complement the trouble of using fixator in DLSS. This study evaluated the existing fixator through the mechanical test and modified fixators using the finite element analysis(FEA). Displacement, stiffness and Von-Mises stress were found to have similar values to those obtained from the mechanical test and the FEA in the biomechanical loading condition. Effects of variation in length and thickness were investigated to design an optimal fixator.

  • PDF

요추부 극돌기간 고정기구의 생체역학적 해석 (Biomechanical Analysis of Lumbar Interspinous Process Fixators)

  • 허순;박정홍;이성재;손권
    • 한국정밀공학회지
    • /
    • 제23권3호
    • /
    • pp.195-202
    • /
    • 2006
  • The degenerative lumbar spinal stenosis (DLSS) is a disease inducing low back pain, leg pain, convulsion. numbness, and neurogenic claudication from compression of nerve root. Intervertebra fixation was reported to increase the degeneration of neighbor lesion after treatment. Recently, a new surgical technique of inserting a fixator between interspinous processes has been introduced. The purpose of this study is to design the interspinous process fixator with flexibility to complement the trouble of using fixator in DLSS. This study evaluated the existing fixator through the mechanical test and modified it using the finite element analysis (FEA). The evaluation was based on the displacement, stiffness and von-Mises stress obtained from the mechanical test and calculated from the FEA in the biomechanical loading condition. Effects of variation in length and thickness were investigated to design an optimal fixator. Three prototypes were manufactured using FEA results. Mechanical tests under the biomechanical loading condition were performed to select the best one from these three. The selected fixator increased flexiblity by 32.9%.

자주포 발전기 스플라인 축 내구성 향상을 위한 최적 설계 기법 (The Optimal Design Technique for Improving Durability of Spline Shaft of the Self Propelled Artillery' Generator)

  • 김병호;강현제;박영일;서재현
    • 한국군사과학기술학회지
    • /
    • 제18권5호
    • /
    • pp.485-491
    • /
    • 2015
  • In this study, the experimental and analytical investigation on structural integrity evaluation of spline shaft of self propelled artillery' generator were carried out. For this work, macro and microstructure fractography of spline shaft were observed. According to the results of the structure analysis and simulation, the shaft was redesigned and optimized. To improve the stiffness and shear stress, the material was changed from the SNCM220 to SNCM439 and surface roughness and protective coating treatment are changed to increase the stress relaxation, respectively. From the result of the torsion test of shaft and accelerated life test of generator, the shaft of a SNCM439 with heat-treatment(Q/T) and electroless nickel plating was superior quality reliability and durability than the others. Therefore, modeling and simulation corresponded well with the experimental result and structural safety was confirmed by generator performing.

2열 외부가압 공기 저어널 베어링에서 급기구 위치에 따른 동적계수에 관한 실험적 연구 (An Experimental Study on the Dynamic Coefficients according to the Source Positions in Externally Pressurised Air-lubricated Journal Bearing with Two Row Sources)

  • 이종렬;이준석;이득우;김태형;박보선
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.243-249
    • /
    • 2001
  • This paper has been presented the hydrodynamic effect by the journal speed, eccentricity and source positions in order to overcome the defects of air bearing such as low stiffness and damping coefficient. Choosing the two row source position of air bearing is different from existed investigations in the side of pressure distribution of air film because of the high speed of journal and the wedge effects by the eccentricity. These optimal chooses of the two row source positions enable us to improve the performance of the film reaction force and loading force as making the high speed spindle. In this paper, the pressure behavior in theory of air film according to the eccentricity of journal and the source positions analyzed. The theoretical analysis have been identified by experiments. The results of investigated characteristics may be applied to precision devices like ultra-precision grinding machine and ultra high speed milling.

  • PDF

Enhancement of wave-energy-conversion efficiency of a single power buoy with inner dynamic system by intentional mismatching strategy

  • Cho, I.H.;Kim, M.H.
    • Ocean Systems Engineering
    • /
    • 제3권3호
    • /
    • pp.203-217
    • /
    • 2013
  • A PTO (power-take-off) mechanism by using relative heave motions between a floating buoy and its inner mass (magnet or amateur) is suggested. The inner power take-off system is characterized by a mass with linear stiffness and damping. A vertical truncated cylinder is selected as a buoy and a special station-keeping system is proposed to minimize pitch motions while not affecting heave motions. By numerical examples, it is seen that the maximum power can actually be obtained at the optimal spring and damper condition, as predicted by the developed WEC(wave energy converter) theory. Then, based on the developed theory, several design strategies are proposed to further enhance the maximum PTO, which includes the intentional mismatching among heave natural frequency of the buoy, natural frequency of the inner dynamic system, and peak frequency of input wave spectrum. By using the intentional mismatching strategy, the generated power is actually increased and the required damping value is significantly reduced, which is a big advantage in designing the proposed WEC with practical inner LEG (linear electric generator) system.

면재 두께가 다른 샌드위치 복합재의 굽힘 거동 연구 (A Study on Flexural Behaviors of Sandwich Composites with Facesheets of Unequal Thickness)

  • 신광복;이재열;류봉조;이상진
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.201-210
    • /
    • 2007
  • Sandwich composites made of glass fabric epoxy facesheets with aluminum honeycomb core or balsa core is considered for the structural design of bodyshell of a Korean Low Floor Bus. Initially, in order to select the optimal facesheet and core materials in design stage, the flexural response of a sandwich composite is a critical importance. In this study, theoretical formula which could easily and quickly evaluate and obtain the flexural responses such as deflection and flexural stiffness of a sandwich composite subjected to external load was established. This theory could calculate the flexural responses of sandwich composites with narrow as well as wide width and with facesheets of unequal thickness, and also distinguish between the bending and shear effects of deflection. Finite element analysis using ANSYS V10.0 was used to offer the best elements for real sandwich composites, and flexural test according to ASTM C393 was conducted to compare with the results of theoretical formula and finite element analysis. The results show that the flexural responses of sandwich composites using proposed theoretical formula is in good agreement with those of experiment and finite element method.

점탄성감쇠기를 설치한 구조물의 비용효율성 평가 (Cost-Effectiveness Evaluation of the Structure with Viscoelastic Dampers)

  • 고현무;함대기;조상열
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.387-393
    • /
    • 2001
  • Installing vibration control devices in the structure rises as a solution instead of increasing structural strength considering construction cost. Especially, viscoelastic dampers show excellent vibration control performance at low cost and are easy to install in existing structures compared with other control devices. Therefore, cost-effectiveness of structure with viscoelastic dampers needs to be evaluated. Previous cost-effectiveness evaluation method for the seismically isolated structure(Koh et al., 1999;2000)is applied on the building structure with viscoelastic dampers, which combines optimal design and cost-effectiveness evaluation for seismically isolated structures based on minimum life-cycle cost concept. Input ground motion is modeled in the form of spectral density function to take into account acceleration and site coefficients. Damping of the viscoelastic damper is considered by modal strain energy method. Stiffness of shear building and shear area of viscoelastic damper are adopted as design variables for optimization. For the estimation of failure probability, transfer function of the structure with viscoelastic damper for spectral analysis is derived from the equation of motion. Results reveal that cost-effectiveness of the structure with viscoelastic dampers is relatively high in how seismic region and stiff soil condition.

  • PDF

Application of Buckling Restrained Braces in a 50-Storey Building

  • Sy, Jose A.;Anwar, Naveed;Aung, Thaung Htut;Rayamajhi, Deepak
    • 국제초고층학회논문집
    • /
    • 제3권1호
    • /
    • pp.81-87
    • /
    • 2014
  • The use of Buckling Restrained Braces (BRB) for enhancing the performance of the buildings is gaining wider acceptance. This paper presents the first application of these devices in a major high-rise building in the Philippines. A 50-storey residential reinforced concrete building tower, with ductile core wall, with BRB system is investigated. The detailed modeling and design procedure of buckling restrained brace system is presented for the optimal design against the two distinct levels of earthquake ground motions; serviceable behavior for frequent earthquakes and very low probability of collapse under extremely rare earthquakes. The stiffness and strength of the buckling restrained brace system are adjusted to optimize the performance of the structural system under different levels of earthquakes. Response spectrum analysis is conducted for Design Basis Earthquake level and Service level, while nonlinear time history analysis is performed for the most credible earthquake. The case study results show the effectiveness of buckling restrained braces.

테이퍼드 다이아그리드 초고층 구조물의 형상 최적설계기법 개발 (A Development of a Shape Optimization Design Techniques for the Diagrid Tapered Tall-Building)

  • 한상을;이한주;유종혜;정소영
    • 한국강구조학회 논문집
    • /
    • 제23권3호
    • /
    • pp.349-356
    • /
    • 2011
  • 본 논문에서는 파라메트릭 기법을 이용한 최적설계 알고리즘을 사용하여 최근 들어 다양한 형태를 지니고 있는 비정형 초고층 구조물의 최적 다이아그리드 각도를 찾는 것에 대해 연구하였다. 다이아그리드는 비정형 초고층 구조물을 구성하는 대각방향의 부재로 수직하중과 수평하중에 대해 효과적으로 대응할 수 있는 구조 시스템으로써 다이아그리드의 각도를 최적화 하여 비정형 초고층 구조물의 최대강성을 찾는 것에 목적을 두었다. 본 연구에서 검증예제로 비정형 형상인 원통형 구조물과 테이퍼드 원형 구조물에 다이아그리드 최적설계 알고리즘을 적용하여 변위를 효과적으로 제어하는 다이아그리드의 최적각도를 검토하였다.

전단벽식 구조의 휨거동을 이용한 마찰감쇠기의 제어성능 (Control Performance of Friction Dampers Using Flexural Behavior of RC Shear Wall System)

  • 정희산;문병욱;박지훈;이성경;민경원;변지석
    • 한국소음진동공학회논문집
    • /
    • 제18권8호
    • /
    • pp.856-863
    • /
    • 2008
  • High-rise apartments of shear wall system are governed by flexural behavior like a cantilever beam. Installation of the damper-brace system in a structure governed by flexural behavior is not suitable. Because of relatively high lateral stiffness of the shear wall, a load is not concentrate on the brace and the brace cannot perform a role as a damping device. In this paper, a friction damper applying flexibility of shear wall is proposed in order to reduce the deformation of a structure. To evaluate performance of the proposed friction damper, nonlinear time history analysis is executed by SeismoStruct analysis program and MVLEM(multi vertical linear element model) be used for simulating flexural behavior of the shear wall. It is found that control performance of the proposed friction damper is superior to one of a coupled wall with rigid beam. In conclusion, this study verified that the optimal control performance of the proposed friction damper is equal to 45 % of the maximum shear force inducing in middle-floor beam with rigid beam.