• 제목/요약/키워드: optimal retrofitting

검색결과 25건 처리시간 0.022초

Optimal synthesis for retrofitting heat exchanger network

  • Lee, In-Beum;Jung, Jae-Hak;Chang, Kun-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1259-1264
    • /
    • 1990
  • During the past two decades, a lot of researches have been done on the synthesis of grassroot heat exchanger networks(HEN). However, few have been dedicated to retrofit of existing heat exchanger networks, which usually use more amount of utilities (i.e. steam and/or cooling water) than the minimum requirements. This excess gives motivation of trades-off between energy saving and rearranging investment. In this paper, an algorithmic-evolutionary synthesis procedure for retrofitting heat exchanger networks is proposed. It consists of two stages. First, after the amount of maximum energy recovery(MER) is computed, a grass-root network featuring minimum number of units(MNU) is synthesized. In this stage, a systematic procedure of synthesizing MNU networks is presented. It is based upon the concept of pinch, from which networks are synthesized in a logical way by the heuristics verified by the pinch technology. In the second stage, since an initial feasible network is synthesized based on the pre-analysis result of MER and must-matches, an assignment problem between new and existing units is solved to minimize total required additional areas. After the existing units are assigned, the network can be improved by switching some units. For this purpose, an improvement problem is formulated and solved to utilize the areas of existing units as much as possible. An example is used to demonstrate the effectiveness of the proposed method.

  • PDF

Seismic performance comparison of existing public facilities strengthened with RC jacketing and steel bracing

  • Zu Irfan;Abdullah Abdullah;Azmeri Azmeri;Moch. Afiffuddin;Rifqi Irvansyah
    • Earthquakes and Structures
    • /
    • 제25권1호
    • /
    • pp.43-56
    • /
    • 2023
  • Banda Aceh is one of the areas that sustains the most damage during a natural disaster because it contains so many houses, office buildings, public facilities, and schools. Public structures in coastal areas are highly susceptible to earthquakes, resulting in high casualties and property damage. Several public structures were reconstructed during the reconstruction and rehabilitation period. Because this building is located in an area with a high risk of earthquakes, its capacity must be analyzed initially. Additionally, history indicates that Aceh Province has been struck by numerous earthquakes, including the largest ever recorded in 1983 and the most recent earthquake with a magnitude of 9.3 SR on December 26, 2004. The city of Banda Aceh was devastated by this earthquake, which was followed by a tsunami. The possibility of a large earthquake in Banda Aceh City necessitates that the structures constructed there be resistant to seismic risk. This study's objective was to evaluate the seismic performance of the existing building by applying the method of strengthening the structure in the form of jacketing columns and the addition of steel bracing in order to estimate the performance of the structure using multiple ground motions. Therefore, several public buildings must be analyzed to determine the optimal seismic retrofitting technique.

3D Digital Design 기법을 이용한 BWTS 설치 설계 연구 (A Study on Retrofitting BWTS using 3D Digital Design)

  • 지재훈
    • 수산해양교육연구
    • /
    • 제29권2호
    • /
    • pp.503-512
    • /
    • 2017
  • Over the past few years, as maritime trade and traffic were highly expanding, problem of invasive species via ballast water have been raised. In 1988, Canada and Australia had firstly experience that unexpected and hazardous species were observed on their own sea, they have issued the problem to MEPC under the IMO. At the end of many years of discussion, on the diplomatic conference in 13 Feb. 2004, "International Convention for the Control and Management of Ballast Water and Sediments of the Ship" was adopted. Requirements for entering into force of this Convention is that 30 countries ratify and world merchant marine fleet is more than 35% and BWM Convention will be effected after 12months from date satisfying conditions. With Finland ratifying the BWM Convention on 8 Sep. 2016, the fleet amounted to 35.1441% and ratification country became 52 countries. Therefore, after 12month, BWM Convention will be formally effected on 8 Sep. 2017. Ballast Water Treatment System is to be fitted in new ships as well as existing ships. Thus, there are concerns of ship owners to be suitably installed a variety typed BWTS in many kinds of vessels. As approaching for resolving these problems, engineering analysis was carried out research studies and detailed design to analyze to optimal installation space for retrofitting a BWTS using 3D Scanning method, targeting representative DWT 180K Bulk carrier of dry cargo vessels charged more 40% on worldwide vessel and mainly two type BWTS as electrolysis treatment type and ultra violet treatment type. Optimal design of 3D Scanning technology was applied to analyze four step process and the overall conclusion was described in this paper.

Robust seismic retrofit design framework for asymmetric soft-first story structures considering uncertainties

  • Assefa Jonathan Dereje;Jinkoo Kim
    • Structural Engineering and Mechanics
    • /
    • 제86권2호
    • /
    • pp.249-260
    • /
    • 2023
  • The uncertainties involved in structural performances are of importance when the optimum number and property of seismic retrofit devices are determined. This paper proposes a seismic retrofit design framework for asymmetric soft-first-story buildings, considering uncertainties in the soil condition and seismic retrofit device. The effect of the uncertain parameters on the structural performance is used to find a robust and optimal seismic retrofit solution. The framework finds a robust and optimal seismic retrofit solution by finding the optimal locations and mechanical properties of the seismic retrofit device for different realizations of the uncertain parameters. The structural performance for each realization is computed to evaluate the effect of the uncertainty parameters on the seismic performance. The framework utilizes parallel processing to decrease the computationally intensive nonlinear dynamic analysis time. The framework returns a robust design solution that satisfies the given limit state for every realization of the uncertain parameters. The proposed framework is applied to the seismic retrofit design of a five-story asymmetric soft-first-story case study structure retrofitted with a viscoelastic damper. Robust optimal parameters for retrofitting a structure to satisfy the limit state for the different realizations of the uncertain parameter are found using the proposed framework. According to the performance evaluation results of the retrofitted structure, the developed framework is proved effective in the seismic retrofit of the asymmetric structure with inherent uncertainties.

Optimal sensor placement of retrofitted concrete slabs with nanoparticle strips using novel DECOMAC approach

  • Ali Faghfouri;Hamidreza Vosoughifar;Seyedehzeinab Hosseininejad
    • Smart Structures and Systems
    • /
    • 제31권6호
    • /
    • pp.545-559
    • /
    • 2023
  • Nanoparticle strips (NPS) are widely used as external reinforcers for two-way reinforced concrete slabs. However, the Structural Health Monitoring (SHM) of these slabs is a very important issue and was evaluated in this study. This study has been done analytically and numerically to optimize the placement of sensors. The properties of slabs and carbon nanotubes as composite sheets were considered isotopic and orthotropic, respectively. The nonlinear Finite Element Method (FEM) approach and suitable optimal placement of sensor approach were developed as a new MATLAB toolbox called DECOMAC by the authors of this paper. The Suitable multi-objective function was considered in optimized processes based on distributed ECOMAC method. Some common concrete slabs in construction with different aspect ratios were considered as case studies. The dimension and distance of nano strips in retrofitting process were selected according to building codes. The results of Optimal Sensor Placement (OSP) by DECOMAC algorithm on un-retrofitted and retrofitted slabs were compared. The statistical analysis according to the Mann-Whitney criteria shows that there is a significant difference between them (mean P-value = 0.61).

Optimal location of a single through-bolt for efficient strengthening of CHS K-joints

  • Amr Fayed;Ali Hammad;Amr Shaat
    • Structural Engineering and Mechanics
    • /
    • 제89권1호
    • /
    • pp.61-75
    • /
    • 2024
  • Strengthening of hollow structural sections using through-bolts is a cost-effective and straightforward approach. It's a versatile method that can be applied during both design and service phases, serving as a non-disruptive and budget-friendly retrofitting solution. Existing research on axially loaded hollow sections T-joints has demonstrated that this technique can amplify the joint strength by 50%, where single bolt could enhance the strength of the joint by 35%. However, there's a gap in understanding their use for K-joints. As the behavior of K-joints is more complex, and they are widely existent in structures, this study aims to bridge that gap by conducting comprehensive parametric study using finite element analysis. Numerical investigation was conducted to evaluate the effect of through bolts on K-joints focusing on using single through bolt to achieve most of the strengthening effect. A full-scale parametric model was developed to investigate the effect of various geometric parameters of the joint. This study concluded the existence of optimal bolt location to achieve the highest strength gain for the joint. Moreover, a rigorous statistical analysis was conducted on the data to propose design equations to predict optimal bolt location and the corresponding strength gain implementing the verified by finite element models.

The Application of Resettable Device to Semi-Active Tuned Mass Damper Building Systems for Multi-level Seismic Hazard Mitigation

  • Chey, Min-Ho
    • Architectural research
    • /
    • 제14권3호
    • /
    • pp.99-108
    • /
    • 2012
  • An innovative multi-story Semi-Active Tuned Mass Damper (SATMD) building system is proposed to control seismic response of existing structures. The application of adding new stories as large tuned mass and semi-active (SA) resettable actuators as central features of the control scheme is derived. For the effective control of the structures, the optimal tuning parameters are considered for the large mass ratio, for which a previously proposed equation is used and the practical optimal stiffness is allocated to the actuator stiffness and rubber bearing stiffness. A two-degree-of freedom (2-DOF) model is adopted to verify the principal efficiency of the suggested structural control concept. The simulations for this study utilizes the three ground motions, from SAC project, having probability of exceedance of 50% in 50 years, 10% in 50 years, and 2% in 50 years for the Los Angeles region. 12-story moment resisting frames, which are modified as '12+2' and '12+4' story structures, are investigated to assess the viability and effectiveness of the system that aims to reduce the response of the buildings to earthquakes. The control ability of the SATMD scheme is compared to that of an uncontrolled and an ideal Passive Tuned Mass Damper (PTMD) building system. From the performance results of suggested '12+2' and '12+4' story retrofitting case studies, SATMD systems shows significant promise for application of structural control where extra stories might be added.

수학적 모델 및 퍼지 추론에 의한 고도 활성슬러지 공정의 통합 평가 (Integrated Evaluation of Advanced Activated Sludge Processes Based on Mathematical Model and Fuzzy Inference)

  • 강동완;김효수;김예진;최수정;차재환;김창원
    • 대한환경공학회지
    • /
    • 제32권1호
    • /
    • pp.97-104
    • /
    • 2010
  • 현재 강화된 방류수 수질 기준에 발맞춰 질소 인 제거를 포함한 고도처리 공정을 건설 중이거나 기존 표준활성슬러지 공정에서 고도처리공정으로의 개선이 추진되어지고 있다. 그러나 다양한 고도처리공정의 적용을 검토함에 있어 제거 효율 측면에서의 단순 평가만이 사용되고 있다. 따라서 고도처리공정 적용 시 제거 효율 뿐 아니라 슬러지 생산, 포기 비용 등을 복합적으로 평가할 수 있는 방법이 필요하였다. 따라서 본 연구에서는 표준활성슬러지 공정으로 운영 중인 S 하수처리장을 Biological nutrient removal(BNR) 공정으로 개선할 경우를 가정한 대안 공정 평가 방법을 제안하였다. 시간적, 비용적 장점을 가지며 객관적인 평가 기준으로 대두되고 있는 수학적 모델을 이용한 시뮬레이션을 통해 대안 공정으로 선정된 Anaerobic/anoxic/oxic ($A^2$/O), Virginia initiative plant (VIP), Daewoo nutrient removal (DNR) 공정에 대해 평가하였다. 시뮬레이션 결과를 바탕으로 공정의 처리 성능 뿐 아니라 슬러지 생산량 및 에너지 효율을 포함한 5가지 성능 지수들을 적용함으로써 개별 항목간의 비교 평가가 가능하였으며, 최적 공정을 제시하기 위한 객관적 판단과정을 퍼지 추론을 통하여 구현하였다.

교량의 생애주기비용 효율적인 최적 내진보강과 유지관리전략 - (I) 생애주기 지진신뢰성해석 프로그램 개발 (Life-Cycle Cost Effective Optimal Seismic Retrofit and Maintenance Strategy of Bridge Structures - (I) Development of Lifetime Seismic Reliability Analysis S/W)

  • 이광민;최은수;조효남;안형준
    • 대한토목학회논문집
    • /
    • 제26권6A호
    • /
    • pp.965-976
    • /
    • 2006
  • 지진하중에 대한 구조물의 생애주기비용 최적설계나 성능개선을 위해서는 생애주기 지진신뢰성해석에 기초한 접근이 불가피하다. 최근 몇몇 연구자들이 생애주기비용에 기초한 구조물의 내진설계 및 성능개선을 위한 방법론은 제안하여 왔지만, 대부분의 연구가 생애주기비용 산정을 위한 방법론 개발에 중점을 둔 연구이다. 따라서 대부분의 기존연구에서는 열화하는 구조물의 생애주기 지진신뢰성해석에 있어서 내진보강, 유지관리, 그리고 환경적 열화와 같은 주요한 인자들을 고려하지 못한 것이 사실이다. 이에 본 연구에서는 교량의 체계적인 생애주기 지진신뢰성해석 방법론을 제안하였고, 교량의 지진신뢰성해석을 위한 프로그램인 HPYER-DRAIN2DX-DS를 개발하였다. 개발된 프로그램은 내진보강이나 유지전략의 적용유무에 따른 예제교량의 생애주기 지진신뢰성해석 문제에 적용되었으며, 이를 통해 프로그램의 적용성을 검토해 보았다. 적용 예를 통해 본 연구에서 개발된 HPYER-DRAIN2DX-DS는 지진에 대한 교량의 생애주기비용 최적설계, 내진보강 및 유지관리에 있어 서 매우 유용한 도구로 사용될 수 있을 것으로 판단된다.

마찰형 감쇠기가 설치된 다자유도 비선형 건물의 응답특성 (Response Characteristics of a Nonlinear MDOF Structure with Friction Dampers)

  • 이성경;박지훈;문병욱;민경원;이상현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.561-567
    • /
    • 2007
  • This paper deals with the numerical model of a bracing-friction damper system and its deployment using the optimal slip load distribution for the seismic retrofitting of a damaged building. The Slotted Bolted Connection (SBC) type friction damper system was tested to investigate its energy dissipation characteristic. Test results coincided with the numerical ones using the conventional model of a bracing-friction damper system. The placement of this device was numerically explored to apply it to the assumed damaged-building and to evaluate its efficiency. It was found by distributing the slip load that minimizes the given performance indicies based on structural response. Numerical results for the damaged building retrofitted with this slip load distribution showed that the seismic design of the bracing-friction damper system under consideration is effective for the structural response reduction.

  • PDF