• Title/Summary/Keyword: optical interferometer

Search Result 616, Processing Time 0.029 seconds

Diffraction grating interferometer for null testing of aspheric surface with binary amplitude CGH (이진 컴퓨터 형성 홀로그램을 이용한 비구면 형상 측정용 위상편이 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.4
    • /
    • pp.313-320
    • /
    • 2004
  • We present a null testing method fer aspheric surfaces, utilizing a phase-shifting diffraction grating interferometer along with a binary amplitude computer generated hologram (CGH). The binary amplitude CGH is designed to compensate for the wavefront between a point source and the aspheric surface under test. The fringe visibility of the grating interferometer is controlled easily by selecting suitable grating diffraction orders for the measurement and reference wavefronts or by optimizing the groove shape of the grating used. The binary amplitude CGH is designed by numerical analysis of ray tracing and fabricated using e-beam lithography for autostigmatic testing. Experimental results of a large-scale aspheric mirror surface are discussed to verify the measurement performance of the proposed diffraction grating interferometer.

Optical Encryption System Using Two Linear Polarizer and Phase Mask (두 선형 편광기와 위상 마스크를 사용한 광 암호화 시스템)

  • 배효욱;신창목;서동환;박세준;조웅호;김수중
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.3
    • /
    • pp.10-18
    • /
    • 2003
  • In this paper, we propose an optical encryption system based on the encryption of information using the phase component of a wavefront and orthogonal polarization in a Mach-Zehnder interferometer. Since the incoherence of the two perpendicularly polarized lights removes interference component, the decrypted image is stable. In encryption process, the original image is converted into an image having random polarization state by the relative phase difference of horizontal polarization and vertical polarization, so we cannot obtain the original information from the random polarization distribution. To decrypt an Image, the random polarization distribution of encrypted image is divided into two orthogonal components, then key image must be placed on vertical path of Mach-Zehnder interferometer. The decrypted image is obtained In the form of intensity by use of an analyzer.

Nonlinear fiber optic CDMA coder and decoder (비선형 간섭계를 이용한 광 코드 분할 다중 접속 부호기와 복호기)

  • Jeong, Je-Myung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.1
    • /
    • pp.53-59
    • /
    • 2000
  • We propose a modified nonlinear fiber optic interferometer which can serve to generate binary optical pulse sequences for CDMA networks, and to decode them. In one arm cross-phase modulation between a CW signal and a counter- or copropagating high-power pulse takes place in sequences of segment connected via VDM couplers. Preliminary experimental results on code generation as well as autocorrelation and crosscorrelation are presented, using Sagnac interferometer. As we expected, the experimental results show that the outputs of the interferometer device are not summed simply on the basis of power, but the sin-squared version of it. Arbitrary codes can in principle be implemented.

  • PDF

Preliminary Study of the Measurement of Foreign Material in Galvanic Corrosion Using Laser Ultrasonic

  • Hong, Kyung Min;Kang, Young June;Park, Nak Kyu;Choi, In Young
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.323-327
    • /
    • 2013
  • A laser ultrasonic inspection system has the advantage of nondestructive testing. It is a non-contact mode using a laser interferometer to measure the vertical displacement of the surface of a material caused by the propagation of ultrasonic signals with the remote ultrasonic generated by laser. After raising the ultrasonic signal with a broadband frequency range using a pulsed laser beam, the laser beam is focused to a small point to measure the ultrasonic signal because it provides an excellent measurement resolution. In this paper, foreign materials are measured by a non-destructive and non-contact method using the laser ultrasonic inspection system. Mixed foreign material on the corroded part is assumed and the laser ultrasonic experiment is conducted. An ultrasonic wave is generated by pulse laser from the back of the specimen and an ultrasonic signal is acquired from the same location of the front side using continuous wave laser and Confocal Fabry-Perot Interferometer (CFPI). The characteristic of the ultrasonic signal of existing foreign material is analyzed and the location and size of foreign material is measured.

A Simulation Study on the Transfer Characteristics of the Talbot Pattern Through Scintillation Screens in the Grating Interferometer (격자 간섭계에서 탈봇 패턴의 섬광체 스크린 투과 시 전달 특성에 대한 시뮬레이션 연구)

  • Kim, Daeseung;Kim, Youngju;Lee, Seho;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.67-75
    • /
    • 2019
  • Grating interferometry based imaging technology is a kind of radiation imaging system, which can acquire not only absorption image but also phase difference and dark field image using the Talbot pattern. However, because of the technological difficulties and high cost of fabricating the gratings that make up the system, much efforts are being made to look for ways to replace them. The is a preliminary study to see how the Talbot pattern transfer through various kinds of scintillators and if the optical grating can be a way to replace the conventional absorption gratings. The geometry of the interferometer, the scintillator model, and the scintillator thickness are the main inputs for our simulation. We have used the concept of modulation for quantitative analysis of the contrast ratio of the Talbot pattern. This research is expected to provide very useful information on the design of optical gratings, which is an alternative way to analyze the Talbot pattern, which we have filed a patent on.

Fabrication of Planar Type Optical Waveguide for the Application of Biosensor and Detection Characteristics of Staphylococcus Aureus (바이오센서용 평판형 광도파로 센서 제작 및 황색포도상구균 검출 특성)

  • Kim, Jun-Hyong;Yang, Hoe-Young;Yu, Chong-Hee;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.223-223
    • /
    • 2009
  • In this paper, designed and simulated Power Splitter (PS) integrated Mach-Zehnder interferometer (MZI) based planar type optical waveguide devices (which is called here a PS-MZI). The PS-MZI optical waveguide sensor was preceded by a Y-junction, which splits the input power between the sensor, and a reference branch, to minimize the effect of optical power variations. The PS-MZI optical waveguide sensor induced changing phases of the incident beam, which had fallen upon the waveguide through computer simulation, according to the small changes in the index of refraction, thus beam intensity was changed. The waveguide were optimized at a wavelength of 1550 nm and fabricated according to the design rule of 0.45 delta%, which is the difference of refractive index between the core and clad. The fabrication of PS-MZI optical waveguide sensor was performed by a conventional planar lightwave circuit (PLC) fabrication process. The PS-MZI optical waveguide that was fabricated to be applied as a biosensor revealed a low insertion loss and a low polarization-dependent loss. After having etched the over-clad at the sensor part in the MZI optical waveguide that was fabricated, Ti deposition was made on the adhesion layer, and then Au thin-film deposition was carried out thereon. In addition, its optical properties were measured by having changed the index of refraction oil at the sensing part of the MZI. To apply the planar type PS-MZI optical waveguide as a biosensor, a detection test for Staphylococcus aureus was conducted according to changes in concentration, having adopted Ti-alkoxide as ligand. The detection result of the S. aureus by the PS-MZI optical waveguide sensor was possible to the level of $10^1$ CFU/ml.

  • PDF