• 제목/요약/키워드: optical fiber measurements

검색결과 117건 처리시간 0.022초

Mach-Zehnder 광섬유 간섭계를 이용한 압전형 진동발생기의 동특성 조사 (The Measurements of Vibration Displacement of the Piezoelectric Exciter Using Mach-Zehnder Optical Fiber Interferometer)

  • 조승일;김성부;이종규;이용봉;이두희
    • 한국소음진동공학회논문집
    • /
    • 제16권10호
    • /
    • pp.1044-1049
    • /
    • 2006
  • The vibration exciter with the accurate calibration requires a low distortion along a single axis over a wide range of frequency. The fabricated piezoelectric exciter was composed of a base, piezoelectric element(Venitron PZT 5A), electrode and seismic mass. Its performance characteristics is evaluated the Mach-Zehnder optical fiber interferometer. The phase of the optical wave passing through the optical fiber around the piezoelectric element was related the vibrational amplitude with a change of the applied sinusoidal voltage on the piezoelectric element. The dynamic characteristics of vibration exciter can be obtained by measuring the vibrational amplitude with a sinusoidal applied voltage on the piezoelectric element. The sensitivity of the fabricated piezoelectric exciter had a 0.4 nm/V which was uniform up to 20 kHz.

Chalcogenide 광섬유를 이용한 호흡측정 센서 개발을 위한 기초 연구 (Feasibility study on the development of respiration sensor using a chalcogenide optical fiber)

  • 유욱재;조동현;장경원;오정은;이봉수;탁계래
    • 센서학회지
    • /
    • 제16권5호
    • /
    • pp.331-336
    • /
    • 2007
  • In this study, we have fabricated an infrared optical fiber based sensor which can monitor the respiration of a patient. The design of a chalcogenide optical fiber based sensor is suitable for insertion into a high electro-magnetic field environment because the sensor consists of low cost and compact mid-infrared components such as an infrared light source, a chalcogenide optical fiber and a thermopile sensor. A fiber-optic respiration sensor is capable of detecting carbon dioxide ($CO_{2}$) in exhalation of a patient using the infrared absorption characteristics of carbon gases. The modulated infrared radiation due to the presence of carbon dioxide is guided to the thermopile sensor via a chalcogenide receiving fiber. It is expected that a mid-infrared fiber-optic respiration sensor which can be developed based on the results of this study would be highly suitable for respiration measurements of a patient during the procedure of an MRI.

풍력터빈 블레이드 상태 감시용 광섬유격자 센서시스템 (FBG sensor system for condition monitoring of wind turbine blades)

  • 김대길;김현진;송민호
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.75-82
    • /
    • 2013
  • We propose a fiber grating sensor system for condition monitoring of large scale wind turbine blades. For the feasibility test of the proposed sensor system, a down-scaled wind turbine has been constructed and experimented. Fiber grating sensors were attached on a blade surface for distributed strain and temperature measurements. An optical rotary joint was used to transmit optical signals between the FBG sensor array and the signal processing unit. Instead of broadband light source, we used a wavelength-swept fiber laser to obtain high output power density. A spectrometer demodulation is used to alleviate the nonlinear wavelength tuning problem of the laser source. With the proposed sensor system we could measure dynamic strain and temperature profiles at multi-positions of rotating wind turbine blades.

A Fiber Optic Sensor for Measurements of Solute Concentration in Fluids

  • Kim, Chang-Bong;Su, C.B.
    • Journal of the Optical Society of Korea
    • /
    • 제7권2호
    • /
    • pp.102-105
    • /
    • 2003
  • A new and simple calibration technique that greatly enhances the measurement sensitivity of conventional fiber-optic reflectometry based on Fresnel reflection from the tip of a fiber is used for demonstrating the feasibility of measuring solute concentrations and index changes in fluids to very high precision. The amplitude of pulses originating from reflection from the fiber-fluid interface is compared in real-time with the amplitude of reference pulses from a fiber-air interface such that errors caused by pulse amplitude fluctuations and slightly varying detector responses are corrected. Using solutions of salt and water, it is demonstrated that the technique is capable of measuring index changes of about $1 {\times} 10^{-5}$ corresponding to a salt concentrations of 0.01 %.

In situ cavity loss measurements of a mode-locked erbium-doped fiber ring laser by thed relaxation oscillation frequency method

  • Jhon, Young-Min;Kim, Bong-Kyu;Kim, Dong-Hwan;Kim, Myong-Wook;Kim, Sang-Kuk;Choi, Sang-Sam
    • Journal of the Optical Society of Korea
    • /
    • 제4권1호
    • /
    • pp.11-13
    • /
    • 2000
  • We experimentally measured the cold cavity loss of a mode-locked erbium-doped fiber ring laser in situ by using the relaxation oscillation frequency method. The relaxation oscillation frequency is measured for various pumping powers and the data is fitted by the least squares method with a theoretical curve of parameters including the cavity loss. We obtained a cavity loss of 15.3$\pm$0.5 dB which was found to agree with the results of direct transmission loss measurements.

SHM by DOFS in civil engineering: a review

  • Rodriguez, Gerardo;Casas, Joan R.;Villalba, Sergi
    • Structural Monitoring and Maintenance
    • /
    • 제2권4호
    • /
    • pp.357-382
    • /
    • 2015
  • This paper provides an overview of the use of different Distributed Optical Fiber Sensor systems (DOFSs) to perform Structural Health Monitoring (SHM) in the specific case of civil engineering structures. Nowadays, there are several methods available for extracting distributed measurements from optical fiber, and their use have to be according with the aims of the SHM performance. The continuous-in-space data is the common advantage of the different DOFSs over other conventional health monitoring systems and, depending on the particular characteristics of each DOFS, a global and/or local health structural evaluation is possible with different accuracy. Firstly, the fundamentals of different DOFSs and their principal advantages and disadvantages are presented. Then, laboratory and field tests using different DOFSs systems to measure strain in structural elements and civil structures are presented and discussed. Finally, based on the current applications, conclusions and future trends of DOFSs in SHM in civil structures are proposed.

비접촉 ID카드 계수를 위한 자동화 시스템 개발 (Study on Development of Automation System for Non-Contact Counting of ID Card)

  • 강대화;홍준희;곽양양;이혁원
    • 한국생산제조학회지
    • /
    • 제22권4호
    • /
    • pp.652-657
    • /
    • 2013
  • In this study, we developed a counting method for non-contact ID cards using an optical fiber displacement sensor instead of the traditionally used friction counting method. The proposed method has the advantage of high speed and automated measurement. For counting non-contact ID cards, an H-type optical fiber sensor, jig part, and counting program are developed separately to build the system and adjust it. Through the experimental test results, it was confirmed that counting is possible with one type of international ID card and one type of financial security card based on ISO7810. Furthermore, by applying the proposed method to 100 ID cards 100 times repeatedly, it was confirmed that it has high accuracy and an error ratio of 0%. We experimentally demonstrated that the proposed counting method for non-contact ID cards using an optical fiber displacement sensor can perform measurements with high accuracy and high speed.

자유 공간 광통신 시스템에서 신호 변동 억제를 위한 전광 자동 이득 조절 어븀 첨가 광섬유 증폭기의 성능 평가 (Performance Evaluation of an All-optical Automatic Gain-controlled Erbium-doped Fiber Amplifier for Suppression of Signal Fluctuation in Terrestrial Free-space Optical Communication Systems)

  • 정유석;김철한
    • 한국광학회지
    • /
    • 제33권3호
    • /
    • pp.99-105
    • /
    • 2022
  • 자유 공간 광통신 시스템에서 발생하는 대기 외란에 의한 광신호 변동을 억제하기 위하여 전광(all-optical) 자동 이득 조절(automatic gain controlled, AGC) 어븀 첨가 광섬유 증폭기(erbium-doped fiber amplifier, EDFA)를 활용할 때의 성능을 실험적으로 평가하였다. EDFA에 입력되는 광신호 입력을 -30 dBm과 -10 dBm으로 각각 설정하여 증폭기가 소 신호 영역과 포화 영역에서 동작할 때의 성능을 실험적으로 비교하였다. 이 때 광신호의 요동은 음향 광학 변조기(acousto-optic modulator, AOM)를 활용하여 구현하였다. 실험 결과로부터 EDFA가 소 신호 영역에서 동작하며, 피드백되는 증폭된 자발 방출(amplified spontaneous emission, ASE) 광 전력이 0 dBm으로 증폭기를 포화시킬 수 있는 경우에 가장 작은 광신호 요동 특성을 얻을 수 있음을 확인하였다.

Current-induced Phase Demodulation Using a PWM Sampling for a Fiber-optic CT

  • Park, Hyoung-Jun;Lee, June-Ho;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.240-244
    • /
    • 2010
  • In this work, we used PWM sampling for demodulation of a fiber-optic interferometric current transformer. The interference signal from a fiber-optic CT is sampled with PWM triggers that produce a 90-degree phase difference between two consecutively sampled signals. The current-induced phase is extracted by applying an arctangent demodulation and a phase unwrapping algorithm to the sampled signals. From experiments using the proposed demodulation, we obtained phase measurement accuracy and a linearity error, in AC current measurements, of ~2.35 mrad and 0.18%, respectively. The accuracy of the proposed method was compared with that of a lock-in amplifier demodulation, which showed only 0.36% difference. To compare the birefringence effects of different fiber-optic sensor coils, a flint glass fiber and a standard single-mode fiber were used under the same conditions. The flint glass fiber coil with a Faraday rotator mirror showed the best performance. Because of the simple hardware structure and signal processing, the proposed demodulation would be suitable for low-cost over-current monitoring in high voltage power systems.

나노 사이즈 광프로브에 의한 에버네슨트파의 측정 (Measurements of Evanescent Wave using a Mano-size Optical Probe)

  • 최영규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권1호
    • /
    • pp.30-35
    • /
    • 2004
  • We have carried out a basic experiment in order to develope a super high-resolution optical microscope which transcend the limitation of diffraction and the wavelength of lightwave. The image of this scope is composed by measuring the evanescent wave which is localized on the surface of the testing materials. A detecting probe was fabricated with a single mode optical fiber to be sharpened by the chemical etching, and drived by PZT. The standing wave of $0.33\mu\textrm{m}$ wavelength evanescent wave which was generated from the $0.78\mu\textrm{m}$-wavelength semiconductor laser was detected by the $0.5\mu\textrm{m}$-thickness optical fiber probe.