• Title/Summary/Keyword: optical eyes

Search Result 153, Processing Time 0.023 seconds

Spherical arrangement of biomimetic polymer photonic structures (자연모사를 통한 미세 고분자 포토닉 구조의 구면배열에 관한 연구)

  • Jeong, Ki-Hun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.403-404
    • /
    • 2007
  • Compound eyes in nature present intriguing topics in physiological optics due to their unique optical scheme for imaging. For example, a bee's eye has thousands of integrated photonic units called ommatidia spherically arranged along a curvilinear surface so that each unit points in a different direction. The omni-directionally arranged ommatidium collects incident light with a narrow range of angular acceptance and independently contributes to the capability of wide field-of-view (FOV) detection. Artificial implementation of compound eyes has attracted a great deal of research interest because the wide FOV exhibits a huge potential for medical, industrial, and military applications. So far, imaging with a FOV over $90^{\circ}$ has been achieved only with fisheye lenses which rely on bulky and expensive multiple lenses and require stringent alignment. In this talk, we will discuss about the spherical 3D arrangement of the photonic structures of biologically inspired artificial compound eyes in a small form-factor to have and the functional and anatomical similiarity with natural compound eyes.

  • PDF

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF

A Study for the Refractive Error in Middle and High School Pupils on the Basis of Their Glasses Power (안경도수를 근거로 한 중·고등학생의 굴절이상에 관한 연구)

  • Sung, Duk-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.169-175
    • /
    • 2003
  • This research reviewed that 83 male subjects. 89 female subjects of middle and high school visited D Optical shop at the downtown of Daegu more than twice from January, 1999 to January, 2003 and obtained the following results by using the visual acuity prescription of them for which D Optical shop was keeping. 1. The classification of correction power for 190 myopia eyes was examined (87 male eyes, 103 female eyes) showed 89 eyes(46.82%) between $0.25D{\leq}3.00D$, 86 eyes(45.26%) between $3.25D{\leq}6.00D$, 15 eyes(7.89%) for over 6.25D. 2. The kind of 154 astigmatism subjects(79 male eyes, 75 female eyes) was direct astigmatism 83.77%, reverse astigmatism 11.69%, oblique astigmatism 4.55%. The cylindrical correction power for astigmatic eyes was 61 eyes(39.61%) between $0.25D{\leq}0.50D$, 60 eyes(38.96%) between 0.50D<1.00D, 121 eyes(78.57%) for less than 1.06D, 6 eyes(0.65%) for over 3.00D. 3. The variation of spherical power showed 161 eyes(46.80%) between $0.00D{\leq}0.50D$, 109 eyes(31.69%) between $0.51D{\leq}1.00D$, 17 eyes(4.94%) for over 2.01D variation. 4. The variation of astigmatic power showed 92 eyes(59.74%) between $0.00D{\leq}0.50D$, 39 eyes(25.32%) between $0.26D{\leq}0.50D$, 10eyes (6.49%) between $0.51D{\leq}0.75D$, 13 eyes(8.44 %) for over 0.76D astigmatic variation. 5. The variation of equivalent spherical power showed 137 eyes(39.83%) between $0.00D{\leq}0.50D$, 126 eyes(36.63%) between $0.51D{\leq}1.00D$, 40 eyes(11.63%) between $1.01D{\leq}1.50D$, 21 eyes(6.10%) between $1.51D{\leq}2.00D$, 20 eyes(5.81%) for over 2.01D variation.

  • PDF

Assessment of retinal degeneration with optical coherence tomography in a dog (Ocular coherence tomography를 이용한 개의 망막변성증 평가)

  • Ji, Dongbeom;Yoo, Sukjong;Seo, Kangmoon;Jeong, Manbok
    • Korean Journal of Veterinary Research
    • /
    • v.53 no.2
    • /
    • pp.137-141
    • /
    • 2013
  • To report retinal image of in a 6-year-old male castrated poodle dog with a 2-month history of nyctalopia using optical coherence tomography (OCT). Ocular reflexes were present in both eyes and slit lamp examination showed anterior subscapular cataract in the right eye. There were fundus abnormalities in both eyes similar to retinal degeneration. Scotopic electroretinograms (ERGs) revealed significantly subabnormal amplitudes and prolonged implicit time, whereas photopic ERGs were better maintained, although far from normal. OCT of affected dogs revealed generalized retinal thinning much more than a normal age-matched dog. Therefore, OCT scanning is considered to be a useful method for retinal evaluation in dogs with retinal degeneration.

Optimum thickness of GaAs top layer in AlGaAs-based 850 nm VCSELs for 56 Gb/s PAM-4 applications

  • Yu, Shin-Wook;Kim, Sang-Bae
    • ETRI Journal
    • /
    • v.43 no.5
    • /
    • pp.923-931
    • /
    • 2021
  • We studied the influence of GaAs top-layer thickness on the small-signal modulation response and 56 Gb/s four-level pulse-amplitude modulation eye quality of 850 nm vertical-cavity surface-emitting lasers (VCSELs). We considered the proportionality of the gain-saturation coefficient to the photon lifetime. The simulation results that employed the transfer-matrix method and laser rate equations led to the conclusion that the proportionality should be considered for proper explanation of the experimental results. From the obtained optical eyes, we could determine an optimum thickness of the GaAs top layer that rendered the best eye quality of VCSEL. We also compared two results: one result with a fixed gain-saturation coefficient and the other that considered the proportionality. The former result with the constant gain-saturation coefficient demonstrated a better eye quality and a wider optimum range of the GaAs top-layer thickness because the resultant higher damping reduced the relaxation oscillation.

A Comparative Study on Theories of Optical Disease Based on Si-sheng-xin-yuan and Eui-gam-jung-ma (<사성심원>과 <의감중마>의 안병이론에 관한 비교 고찰)

  • Lee Sang man;Eun Hyun Sup;Chi Gyoo Yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1141-1146
    • /
    • 2003
  • In order to investigate different and original theories on pathology of eyes from the past main etiology of fire and heat, two texts of Si-sheng-xin-yuan written by Huang Yuan Yu and Eui-gam-jung-ma written by Lee Gyu Jun are selected and analysed in terms of pathology and prescription. Huang explained that diseases of the eyes are usually born of functional disorders of spleen and stomach(脾胃升降失調) accompanied with turbidity change of energy and blood(氣血淸濁變化). In the meantime, Lee described that the diseases are made from disorders of activities of essence, spirit, energy and blood stored in 5 viscera. So following them, the main point of treatment for the diseases of eyes is to restore and clarify the stagnated gastrointestinal(GI) function, or to supply the clear essence and blood to eyes respectively. Also they have same opinions that the fire and heat are the secondary symptoms of the optical diseases. Therefore Huang focused on cleaning the phlegm and leaking the moisture of GI tract to treat those symptoms, and Lee emphasized on nourishing essential energy of kidney and liver on the other hand. Although they preferred to use radical therapy than symptomatic one. But it can be deduced that Huang's theory is more positive and direct therapy and Lee's one is more basic but indirect treatment.

Relationship between Progressive Changes in Lamina Cribrosa Depth and Deterioration of Visual Field Loss in Glaucomatous Eyes

  • Kim, You Na;Shin, Joong Won;Sung, Kyung Rim
    • Korean Journal of Ophthalmology
    • /
    • v.32 no.6
    • /
    • pp.470-477
    • /
    • 2018
  • Purpose: To investigate the relationship between the progression of visual field (VF) loss and changes in lamina cribrosa depth (LCD) as determined by spectral-domain optical coherence tomography (SD-OCT) enhanced depth imaging in patients with primary open angle glaucoma (POAG). Methods: Data from 60 POAG patients (mean follow-up, $3.5{\pm}0.7$ years) were included in this retrospective study. The LCD was measured in the optic disc image using SD-OCT enhanced depth imaging scanning at each visit. Change in the LCD was considered to either 'increase' or 'decrease' when the differences between baseline and the latest two consecutive follow-up visits were greater than the corresponding reproducibility coefficient value ($23.08{\mu}m$, as determined in a preliminary reproducibility study). All participants were divided into three groups: increased LCD (ILCD), decreased LCD (DLCD), and no LCD change (NLCD). The Early Manifest Glaucoma Trial criteria were used to define VF deterioration. Kaplan-Meier survival analysis and Cox's proportional hazard models were performed to explore the relationship between VF progression and LCD change. Results: Of the 60 eyes examined, 35.0% (21 eyes), 28.3% (17 eyes), and 36.7% (22 eyes) were classified as the ILCD, DLCD, and NLCD groups, respectively. Kaplan-Meier survival analysis showed a greater cumulative probability of VF progression in the ILCD group than in the NLCD (p < 0.001) or DLCD groups (p = 0.018). Increased LCD was identified as the only risk factor for VF progression in the Cox proportional hazard models (hazard ratio, 1.008; 95% confidence interval, 1.000 to 1.015; p = 0.047). Conclusions: Increased LCD was associated with a greater possibility of VF progression. The quantitative measurement of LCD changes, determined by SD-OCT, is a potential biomarker for the prediction of VF deterioration in patients with POAG.

Simulations of Finite Schematic Eyes for Presbyopia Using the Navarro Eye Model (Navarro 모형안을 이용한 노안 정밀모형안의 전산모사)

  • Kim, Shin-Hwa;Kim, Dal-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.301-309
    • /
    • 2015
  • Purpose: This study was aimed to design new schematic eyes for presbyopia using the Navarro eye model and clinical data. Methods: We collected clinical data of eye-optical parameters of males in their age of 40, 50, and 60 from previous studies, and designed schematic eyes for presbyopia using the ZEMAX program. Results: The presbyopic process and features of the designed schematic eyes well accorded with the clinical data of previous studies. Conclusions: On the basis of the Navarro eye model, a finite schematic eyes for presbyopia were newly designed corresponding with clinical data.

Three-dimensional Binocular Holographic Display Using Liquid Crystal Shutter

  • Kim, Hyun-Eui;Kim, Hee-Seung;Jeong, Kyeong-Min;Park, Jae-Hyeung
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.345-351
    • /
    • 2011
  • We present a novel approach to the holographic three-dimensional display using a liquid crystal shutter for binocular display applications. One of the difficult problems in implementing a binocular holographic three-dimensional display is the extremely narrow viewing angle. This problem is attributed to the spatial light modulator pixel number which restricts the maximum spatial bandwidth of the spatial light modulator. In our proposed method, a beam splitter and liquid crystal shutter are used to present two holograms of a three-dimensional scene to the corresponding eyes. The combination of holographic display and liquid crystal shutter can overcome the problem of the extremely narrow viewing angle, presenting threedimensional images to both eyes with correct accommodation depth cues.

The Evaluation of Visual Quality by Employing Double-pass Principle in Circle Contact Lens Wearers after Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용시 double-pass 원리를 이용한 시력의 질 평가)

  • Kwon, Ki Nam;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.277-284
    • /
    • 2015
  • Purpose: The study aimed to evaluate the effect of circle contact lens wearing on visual quality of the eyes after a refractive surgery. Methods: The objective visual quality was evaluated for 40 eyes who did not get refractive surgery and 30 eyes who got a refractive surgery after applying plano circle contact lenses on their eyes, respectively. Modulation transfer function (MTF), objective scatter index (OSI) and the focusing ratio on retina (Strehl ratio) were measured by using optical quality analysis system (OQAS) and the correlation between pupil size and objective visual quality was analyzed by measuring the pupil size. Results: When wearing circle contact lens on the eyes after refractive surgery, MTF and Strehl ratio were reduced and OSI was increased compared with the eyes without refractive surgery. The eyes after a refractive surgery showed more significant difference changes in MTF, OSI and Strehl ratio according to the pupil size compared with those without refractive surgery. Conclusions: The results showed that wearing of circle contact lens after the refractive surgery has deteriorated the objective visual quality based on the quality of focused image on the retina. Therefore, we suggest that sufficient understanding and consideration about the deterioration of visual quality is necessary in the case of circle contact lens wearing after refractive surgery.