• 제목/요약/키워드: optic

검색결과 2,448건 처리시간 0.034초

광섬유 표면 플라즈몬 공명 센서를 이용한 스트레인 및 온도 측정 (Measurement of temperature and strain using fiber-optic surface plasmon resonance sensor)

  • 정재훈;김민욱
    • 전기전자학회논문지
    • /
    • 제11권2호
    • /
    • pp.77-82
    • /
    • 2007
  • 본 논문에서는 광섬유 표면 플라즈몬 공명 센서를 이용하여 스트레인 및 온도 변화에 따른 센서를 제시하였다. 광섬유 센서의 구조는 광섬유의 클래딩 일부를 제거하여 크롬, 은, 금을 증착한 다층 박막 구조를 모델로 하였고, dip 파장의 변화가 선형성을 보임으로써 효율적인 센서로의 활용 가능성을 보이고자 한다.

  • PDF

센서유형별 측정 변형률을 이용한 철근콘크리트 보의 처짐추정에 관한 실험적 연구 (An experimental study on estimating deflection of RC beam using resistive strain gauge and fiber optic sensor)

  • 이규완;박기태;박흥석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.517-522
    • /
    • 2000
  • In the past few years, the nondestructive inspection technology has greatly developed due to the increased necessity to gain a complete understanding of the bridge behavior. Especially, the deformations of bridges contain a lot of informations about its health state. By measuring these deformations it is possible to analyze the loading and aging behavior of the structure. However, the current methods (such as LVDT, dial gage, optical displacement tranceducer, etc) are often of changeable application on site and have the limitations of installation. In this paper, the classical beam theory was reviewed and the deflections of structure are estimated using measured strain which is easy to acquire. The applicability of this algorithm is verified by a preliminary steel beam test and two types of concrete beam tests. Also fiber optic sensors as well as resistive strain gages were installed in the concrete beams to establish the applicability of fiber optic sensors in the field of civil engineering.

  • PDF

경사 전기장 구동에 의한 수평배열 액정 디스플레이의 전기 광학특성 연구 (Electro-optic Characteristic of Homogeneously Aligned Liquid Crystal Display Driven by an Oblique field)

  • 박상현;이지연;이승희
    • 한국전기전자재료학회논문지
    • /
    • 제19권1호
    • /
    • pp.81-86
    • /
    • 2006
  • We have studied electrode-optic characteristics of in-plane switching (IPS) of liquid crystal director driven by an oblique electric field. Because the conventional IPS mode does not have an electrode on top substrate, it shows not only slow response time due to weak electric field but also slow discharging problem when electrostatic field is generated after fabricating the cell. To solve these problems, we have formed additional electrode including dielectric layer in the inner part of the cell on top substrate and studied electrode-optic characteristics of the new device.

광섬유 센서를 이용한 초음파 검출 (A Fiber-Optic Sensor for Ultrasonic Measurement)

  • 심승환;이광식;이동인;이상훈;김달우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1715-1717
    • /
    • 2001
  • The partial-discharge(PD) is accompanied by physical and chemical phenomena, such as heat, light, noise gas, chemical transformation, electric current, and electromagnetic radiation. The PD can be detected by measuring one of these changes. Although some techniques are employed in this purpose, several obstacles interfere with an on-line measurement. Now, a fiber-optic sensor for detecting ultrasonics is suggested for the on line measurement system with high accuracy. This paper describes the basic principles fiber-optic sensor for ultrasonic measurement.

  • PDF

양의 액정을 이용한 Fringe Field Switching mode의 전기-광학 특성 연구 (Study on electro-optic characteristics of FFS mode using a positive LC)

  • 우창우;하경수;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.171-171
    • /
    • 2010
  • Electro-optic characteristics of liquid crystal display using fringe field switching(FFS) device depend on many parameters such as cell retardation, electrode structure, rubbing angle, cell gap and dielectric anisotropy. In this paper, the light efficiency of FFS mode will be analyzed to confirm the electro-optic characteristics according to positive dielectric anisotropy such as transmittance, operating voltage and response time.

  • PDF

저온 공정의 Si을 이용한 PI 배향 막의 전기광학 특성 향상에 대한 연구 (Si Induced Polymer Based Alignment Layer for Liquid Crystal Orientations with High Electro-Optic Properties at Low Temperature)

  • 김대현
    • 한국전기전자재료학회논문지
    • /
    • 제26권9호
    • /
    • pp.677-681
    • /
    • 2013
  • Apart from the deposition of alignment layer, alignment process needs to be involved for alignment of liquid crystal (LC) molecules. To simplify manufacturing process, several method were used such as rubbing, ion-beam irradiation, UV irradiation, and lithography. But, eventually it needs another treatment for LC alignment. Here, we suggested Si induced polyimide (PI) alignment layer at low temperature. Using this method, we are able to eliminate the alignment process and found that the alignment and electro-optic performance are much better than that of the rubbed PI LC cells. Compared to the rubbed PI cells, the response time was decreased by 70% and C-V characteristics have hysteresis-free.

Optimization of Thermo-Optic Parameters for Temperature-Insensitive LPWG Refractometers

  • Lee, Dong-Seok;Kim, Kyong-Hon;Hwang, Seok-Hyun;Lee, Min-Hee;Lee, El-Hang
    • ETRI Journal
    • /
    • 제28권6호
    • /
    • pp.739-744
    • /
    • 2006
  • In this paper, we report numerically calculated results of testing a temperature-insensitive refractive sensor based on a planar-type long-period waveguide grating (LPWG). The LPWG consists of properly chosen polymer materials with an optimized thermo-optic coefficient for the core layer in a four-layer waveguide structure. The resonant wavelength shift below the spectral resolution of the conventional optical spectrum analyzer is obtained accurately over a temperature change of ${\pm}7.5^{\circ}C$ even without any temperature control. The refractive index sensitivity of the proposed grating scheme is about 0.004 per resonant wavelength shift of 0.1 nm for an optimized thermo-optic coefficient.

  • PDF

광섬유 EFPI 센서를 이용한 실시간 고정밀 변위 측정 (Real-time Measurement of Precision Displacement using Fiber Optic EFPI Sensor)

  • 박상욱;김대현;김천곤;홍창선
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.154-157
    • /
    • 2003
  • Precision displacement of less than a few nm resolution was measured in real-time using fiber optic EFPI sensor. The novel method for real-time processing of analyzing EFPI output signal was developed and verified. Linearity in the mean values of interferometric light intensity among adjacent fringes was shown, and the sinusoidal approximation algorithm that estimates past and coming fringe values was verified through the linearity. Real-time signal processing program was developed, and the intensity signal of the EFPI sensor was transformed to the phase shift with this program. The resolution below 0.4 ~ 10 nm in the displacement range of $0 ~ 300\mu\textrm{m}$ was obtained by reducing the photodetector noise using low-pass filter and signal averaging. The nano-translation stage with a Piezo-electric actuator and the EFPI sensor system was designed and tested. This stage successfully reached to the desired destination in $15\mu\textrm{m}$ range within 1 nm accuracy.

  • PDF

광선추적방식을 적용한 비구면 렌즈 설계 (Design of Aspheric Lens by using Ray Tracing Method)

  • 김수용;한민식;김태호;박정우;김민주;전언찬
    • 한국기계가공학회지
    • /
    • 제6권1호
    • /
    • pp.7-12
    • /
    • 2007
  • The optic industry is a high value-added advanced technology industry combined with the precision machine industry and the digital electronics industry. The aspheric lens, one of optic parts, is a key technology having a significant influence on the performance of optic equipment. So this study relates to designing an aspheric lens to which a ray-tracing method is applied. In the ray-tracing method, a refractive index of material is used, which take an advantage that the location of a light source and incident angle can be fixed, unlike the ray back-tracing scheme.

  • PDF

Intensity Modulated Radiation Therapy of Brain Tumor

  • Kim, Sung-Kyu;Kim, Myung-Se
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.61-64
    • /
    • 2002
  • As intensity modulated radiation therapy compared with conventional radiation therapy, tumor target dose increased and normal tissues and critical organs dose reduced. In brain tumor, treatment planning of intensity modulated radiation therapy was practiced in 4MV, 6MV, 15MV X-ray energy. In these X-ray energy, was considered the dose distribution and dose volume histogram. As 4MV X-ray compared with 6MV and 15MV, maximum dose of right optic-nerve increased 10.1 %, 8.4%. Right eye increased 5.2%, 2.7%. And left optic-nerve, left eye, optic chiasm and brainstem incrased 1.7% - 5.2%. Even though maximum dose of PTV and these critical organs show different from 1.7% - 10.1% according to X-ray energies, these are a piont dose. Therefore in brain tumor, treatment planning of intensity modulated radiation therapy in 9 treatment field showed no relation with energy dependency.

  • PDF