• Title/Summary/Keyword: ophthalmic test

Search Result 279, Processing Time 0.016 seconds

A Study on the Optical Properties of Contact Lens Analyzer CA-20 (CONTACT LENS ANALYZER CA-20의 광학계 성능 조사)

  • Ji, Taeksang;Lim, Hyeonseon;Kim, Bonghwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.199-203
    • /
    • 2000
  • Magnification shall large to test a surface of a contact lens also chromatic aberration and distortion to be removed. Be used of this study a contact lens analyzer is "CONTACT LENS ANALYZER CA-20", it is a good analyzer to suitable with surface test 16 times of big magnification and distortion.

  • PDF

Investigation of the horizontal heterophoria measurement at distance by various testing method (사위검사 방법의 차이에 따른 원거리 수평사위 검사값 비교)

  • Sim, Hyun-Seog;Lee, Seang-Wook;Jang, Seong-Joo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • To investigate the subjective refractive error with Von Graefe test. Maddox Rod test and polarizing lens test of Horizontal Heterophoria Measurement at distance on normal 109 subjects aged from 18 to 30 years old. The results were as follows: 1. Using Von Graefe Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 65% for exophoria and 20% for esophoria at distance. 2. Using Maddox Rod Horizontal Heterophoria Measurement, they were measured 14% for orthophoria, 57% for exophoria and 29% for esophoria at distance. 3. Using polarizing lens test of Horizontal Heterophoria Measurement, they were measured 15% for orthophoria, 72% for exophoria and 13% for esophoria at distance. 4. Each test average were $1.32{\Delta}BI$ for Von Graefe test, $0.88{\Delta}BI$ for Maddox Rod test and $1.76{\Delta}BI$ for polarizing lens test. 5. Patient's preference distribution were 44% for Von Graefe test, 28% for Maddox Rod test and 28% for polarizing lens test.

  • PDF

A Study of The Refraction at Video Display Terminal (VDT를 이용한 굴절검사에 대한 연구)

  • Lee, Hak Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.49-53
    • /
    • 2000
  • Comparing to an Image test chart which printed from computer. Hahn's standard test chart and Chart project test chart propose to make the program of an image test chart in computer. Test type of the test chart should be programed by difference size which was examined Hangul program of Hangul & Computer Co. An image test of visual acuity most decreased among 3 kinds of testing. Testing of Fixation disparity was same between Diplopia test and chart project test chart, so that. Design of test chart could be programed diverse by Hangul program of Hangul & Computer Co.

  • PDF

The Effectiveness of the Random-dot E by the Difference of the Illumination and Test Distance (조도와 검사 거리의 차이에 의한 Random-dot E의 영향)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.1-4
    • /
    • 2000
  • The test of stereoacuity provides relatively accurate assessment of binocular functior. in the clinical fields. The purpose of this study was to investigate performance on the Random-dot E(RDE) stereotest under the binocular conditions by the difference of the illumination and test distance. The more light illumination increase. The more pass of RDE stereotest increase. On the other hand. On the near distance of test target. All subjects have a pass toe RDE stereatest. But On the far distance of test target. Some subjects have a pass the RDE stereatest. According to the test distance. The more far distance of test target. the less subjects have a pass the RDE stereotest. As a results, The RDE stereotest have effected the test distance and illumination.

  • PDF

Effect of Distance Phoria on Stereoacuity (원거리 사위도가 입체시에 미치는 영향)

  • Chun, Young-Yun;Joo, Seok-Hee;Park, Seong-Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.101-105
    • /
    • 2008
  • Purpose: In this study we measured the mean value of the distance stereoacutiy for adult subjects and evaluated the variation of the distance stereoacuity according to correction of phoria using the Pola Test E-II of Carl Zeiss. Methods: We investigated the distance stereoacuity for 50 adults (male: 29, female: 21) ranging in age from 19 to 46 years using D6 Circle chart and D8 Line chart in the Pola Test E-II. Results: The mean values of the distance stereoacuity measured on the D6 Circle test and D8 Line test were 159.6 and 149.4 seconds of arc respectively. The mean variations of the distance stereoacuity according to correction of phoria in D6 Circle test were increased 43.2 seconds of arc in exophoria and 51 seconds of arc in esophoria, and those in D8 Line test were increased 42 seconds of arc in exophoria and 70.2 seconds of arc in esophoria. Conclusions: We knew from these results that the distance stereoacuity after prescription of phoria improved more esophoria than exophoria.

  • PDF

Color Vision Abnormality of Elementary School Students in Kwang Ju Area (광주지역 초등학생들의 색각이상에 관한 연구)

  • Ryu, Geun-Chang;Yoon, Young;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.89-91
    • /
    • 2007
  • Color vision test was conducted to elementary school students at age of 9 to 13, with total subject number of 598 which live in Gwang Ju area. 325 (54.3%) boys and 273 (45.7%) girls were subjected using Hahn Color Vision test to find out color recognition problems. 1. Ratios of color vision abnomality were 6.25% in 9 year old students, 9.2% in 10 year old students, 8.4% in 12 year old students, 7.8% in 13 year old students, which means 7.9% of the total 598 subjects had color recognition matters. 2. Red-Green dyschromatopsia was 7.8% of the total 598 subjects which includes most of subjects. None of them had green-yellow recognition problem. Full dyschromatopsia had frequency of 0.2%. 3. 10.7% of boys had color vision abnormality, while 10.7% of girls had color vision abnormality, which means that boys have color recognition problems with higher rate than girls.

  • PDF

Measurement of the Refractive power for an Eye by using the Opposite Colors (보색을 이용한 눈의 굴절력 측정)

  • Joung, Maengsig
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.135-141
    • /
    • 2002
  • A study on measurement of refractive power for eyesight by condition of opposite color, has been conducted. In the results of the test, it was observed that farsightedness has better lightness large range. However, in the case of chroma, we cannot distinguish tell the nearsightedness from the farsightedness. Generally, refractive power increased with the increase of large range was revealed. This method is better as compared with red-green test method.

  • PDF

A Study of Eye Refraction state on old Age (노안의 굴절이상과 안경착용에 대한 연구)

  • Kim, Jin-Koo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.81-84
    • /
    • 2001
  • This study can provide the accurate information on the treatment of visual acuity of a old ages by test of eye refraction state. The test was performed the visual acuity test by the object methods, and subjects was the over 45 old age. The eye types were 12% positive for emmetropia, 19% for myopia. and 69% for hyperopia, respectively. The abnormal refraction eyes were 3% positive for simple myopic astigmatism, 16% for myopic astigmatism, 14% for simple hyperopia, 5% for simple hyperopic astigmatism, 62% for mixed astigmatism, respectively. The axis of astigmatisms were 72% positive for against-the-rule astigmatism, 21% for with-the-rule astigmatism, 7% for ablique astigmatism, respectively.

  • PDF

A Study of Sunglasses being sold in Domestic (국내에서 시판되고 있는 선글라스에 관한 연구)

  • Lee, Won Jin;Sung, Duk Yong;Youk, Do Jin;Kang, Sung Soo;Jang, Yoon Seok;Park, Sang Chul;Park, Hae Jong;Shin, Hoy Sun;Jeon, Young Ki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.125-134
    • /
    • 2004
  • By applying the test methods of "Protection Eyewear Standard (KS P 8147)", "Glasses Frame Standard (KS G 3306)" and "Lens Standard for Sunglasses (KS P 4404)", this study analyzed optical functions of sunglasses now being sold in a road shop (A shop), a fashion goods store (B shop), a shop of highway rest area (C shop) and an optical shop (D shop). When compared with sunglasses (UV transmittance rate 8.8%) of a road shop, UV Block effects of sunglasses (UV transmittance rate 0.7%) of an optical shop showed good results. In addition, the average surface resistance against abrasion for sunglasses which was sold at an optical shop was 1.4% that was much higher than that of sunglasses of a road shop(2.2%).

  • PDF

The optical properties on the human model eye (모형 안의 광학적 성능)

  • Lim, Hyeonseon;Ji, Taeksang;Kim, Bonghwan;Kim, Sejin;Yoon, Sungro
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.203-207
    • /
    • 2002
  • In this study, by using the eye model of NAVARRO, KOOIJMAN, MAHKICHOONG, the properties of optical system are reserched in a finite ray tracing method, when ametropia is corrected by glasses or contact lens, this study is useful as a reference. Also, when Auto-refractometer for refraction test and Keratomeler are designed, these eye models can be used.

  • PDF