Analysis of Axial Mis-alignment After Wearing of Toric Soft Contact Lenses (토릭소프트콘택트렌즈의 착용 후 축 정렬 상태의 변화 분석)

  • Kim, Sang-Yoeb;Lee, Dong Yeol;Lee, Sun-Haeng;Kim, Kun-Kyu;Song, Sop;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Purpose: To emphasize the necessity of post-fitting by follow-up test, the mis-alignment was analyzed after initial wearing of toric soft contact lenses (TSCL). Methods: After trial contact lenses were worn to 87 eyes with myopic astigmatism for 1 week, we observed the alignment of axis mark on trial contact lenses using slit lamp and corrected the rotated axis by method of LARS. After final fitting, rotation ratio, rotation degree and rotation position were analyzed compared to initial prescription divided to amount of cylinderical and spherical powers. Results: Rotation ratio of TSCL's axis was increased as increment of both cylinderical powers and (-)spherical powers. An average of rotation degree was $10^{\circ}{\sim}13^{\circ}$ which was not related to amount of their powers. Rotation position of TSCL's axis was more to temporal than to nasal. Conclusions: Because mis-alignment of axis after TSCL wearing induce the poor sight, adjustment of axial alignment as a result of follow-up must be performed.

Composition and Surface Analyses of RGP Contact Lenses (RGP 콘택트렌즈의 성분과 표면 분석)

  • Jang, Jun-Kyu;Shin, Hyung-Sup
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.329-337
    • /
    • 2010
  • Purpose: The surfaces and compositions of rigid gas permeable (RGP) contact lenses were analyzed with the consistent methods, and the basic informations for the composition design of lens materials were suggested. Methods: The bulk structures were analyzed by using Fourier infrared spectroscopy (FTIR), the compositions of surface components were observed by using x-ray photoelectron spectroscopy (XPS), the surface morphology and roughness were observed using atomic force microscopy (AFM), and the wettabilities were estimated by the surface wetting angles. The relations and trends of those results were analyzed. Results: The high oxygen permeability RGP lenses showed the trend that the fluorine decreases and the silicon increases. As the silicon and fluorine contents increased, the carbon and oxygen contents of RGP lens materials decreased at a constant ratio. The decreasing ratio of the carbon contents was three times larger than the decreasing ratio of oxygen contents. The composition of the surface treated lens was far from these tendency line. When the silicon contents increased, the rough surface was formed with the cohered particles. When the fluorine contents increased, the rough surface was formed with the deep flaws. The surface roughness increased and then wettabilities decreased as the silicon and fluorine contents increased. For the surface roughness changes, the increasing ratio of the silicon contents was two times larger than the increasing ratio of fluorine contents. The surface of RGP lens materials appeared the hydrophobic character of which the wettabilities decreased when the roughnesses increased. Conclusions: The surfaces and compositions of RGP contact lenses were measured by the same methods. Those results and relationships were compared and analysed. It is considered that these research results will be applied with the basic data for the composition design of lens materials.

A Study on the Spectacles Wearing State of High School Students (고등학생들의 안경착용에 관한 연구)

  • Doo, Ha-Young;Sim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.107-116
    • /
    • 2000
  • This study is of investigation of refraction error, spectacles and contact lenses wearing state, visual acuity test, ophthalmologic common sense and vision care, using questionnaire study for 850 male and female high school students in Kunsan and Chongup City, Cheolla North Province. The results are as follows: 1. Among the 823 answerers, emmetropia is 18%, myopia is 55.1%, and hyperopia is 7%, respectively. 2. Among the 837 answerers, 381 students(45.5%) wear spectacles or contact lenses. Among the 381 students who wear spectacles or contact lenses, 78% wear only spectacles, 4% wear only contact lenses and 18% wears spectacles sometimes or contact lenses sometimes. 3. The places where the answerers had visual acuity test to wear spectacles or contact lenses are optical shop(64.7%), hospital(28.3%), unchecked(4.2%) and the others(2.7%). The places where the answerers had visual acuity test to change their spectacles or contact lenses are optical shop(82%), hospital(28.3%), unchecked(6.6%) and the others(1.9%). 4. As for the period of visual acuity test, from 6 months to one year is 54.1%, within 6 months is 9.2%, from one year to two years is 29.5%, and more than two years is 7.2%. 5. The contact lens wearers purchased their contact lenses at optical shops(94%) and at hospital(6%). 6. The reasons why they like wearing contact lenses are their appearance(51.2%), convenience in physical excercise(23.l%), lighter weight than spectacles(9.8%) and the others(15.7%). 7. As for the spectacles frame they like, plastic frame is 24.4%, gold or silver plated frame is 43.4%, coloured frame is 32.1%. 8. As for the considerations in choosing spectacles frame, their design is 37%, their quality is 36%, their price is 14.7% and their brand is 12.5%. 9. As for the period for changing spectacles, 10.5% is within 6 months, 57.3% is 6months to 1 year, 22.4% is 1 year to 2 months and 9.6% is more than 2 years. 10. There is a false fact, in Korea, that even though one has his poor eyesight, not wearing custom is helpful for the eyesight recovery. As for their conviction of the false fact, 10.5% of the answerers have 100% conviction, 22.5% of them have 22.5% conviction, 49.5% of them have 50% conviction and 17.5% of them don't have any conviction. 11. 48.5% of the answerers are interested in their vision care while 51.5% of them are not interested at all. As for the way of vision care, the vision-care way to keep enough distant when they are watching TV, when they are using computers and when they are reading, is 49% while the vision-care way such as hypogastric breathing or eye massage is 11%. And alimentotherapy is 4% and the rest who are not interested in vision care is 36%. 12. When they come to an age, the students who want vision correction operation are 45.9% while the students who do not want it are 27%. The students who do not have any idea about the operation are 27.1%

  • PDF

UV Absorbent-added Polymerization and its Application as Ophthalmological Material (자외선 흡수제를 첨가한 고분자 중합 및 안 의료용 소재로의 적용)

  • Sung, A-Young;Kim, Tae-Hun;Ye, Ki-Hun
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.98-103
    • /
    • 2011
  • This study was done for the preparation of macromolecular material with UV-blocking features by adding the benzophenone group that is commonly used as a UV-absorbent and $TiO_2$ which is known to be a very stable material in chemical and physical aspects. Also, we compared the level of UV absorbency of the polymer produced from polymerization with previous materials and measured basic properties such as water content, refractive index and optical transmittance of produced contact lenses. The results of the measurement showed that the refractive index and water content of the contact lens with added UV-absorbent was 1.430~1.440 and 35.0~45.0% respectively, which was similar to that of previous contact lenses. Also, for optical transmittances of each wave length, contact lenses without the UV-absorbent was 89%, 88% and 89% respectively for UV-A, UV-B and visible light, indicating that the UV transmittance is very high though contrary with cases of contact lenses with added 2-hydroxy-4-methoxy-benzophenone and 2,4-dihydroxy-benzophenone which showed transmittances of 0% and 6% respectively for UV-A and UV-B showing a UV-blocking effect. Meanwhile, contact lenses with added $TiO_2$ showed transmittance of 6% and 51% respectively for UV-A and UV-B also showing a UV-blocking effect. The visible transmittance was 77~89% showing that it satisfies the visible transmittance required for ophthalmological materials.

The Effect of Refractive and Corneal Recovery after Discontinuation of Orthokeratology Contact Lenses in Children (각막굴절교정렌즈 어린이 착용자에서 착용 중지 후 굴절력과 각막형상 복귀에 관한 연구)

  • Mun, Mi-Young;Lee, Koon-Ja;Lee, Ji-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: To investigate the corneal recovery after discontinuing orthokeratology (OK) lenses wear in children for long-term period. Methods: Among the OK lens wearers who wear over 8 months and showed successful refractive correction, 25 subjects were selected who want to discontinue the OK lenses. Uncorrected visual acuity, refractive correction, corneal curvature (Sim K), central corneal thickness and corneal eccentricity were measured during the OK lens wearing period and after discontinuation for 1 month. Results: Uncorrected visual acuity and corneal shape had remodeled significantly during the OK lens wear and recovered significantly during the first week of discontinuation. Uncorrected visual acuity and refractive correction had achieved full recovery 2 weeks after discontinuation of lens wear and were highly correlated with the changes in corneal thickness. But corneal shape recovered slowly, eccentricity had recovered fully after 1 month and corneal curvature and central thickness had not been achieved full recovery until 1 month after discontinuation. Conclusions: Recovery of after longterm use of OK lens is rapid for refractive change, but slow for corneal curvature and central thickness that to refit the contact lenses, practitioners need patience.

  • PDF

The Changes in Contrast Sensitivity and Glare Sensitivity when Wearing Circle Contact Lenses after the Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용 시 대비감도 및 눈부심감도 변화)

  • Kwon, Ki Nam;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Purpose: In the present study, the effect of circle contact lenses wear on contrast sensitivity and glare sensitivity in a refractive surgery group was investigated. Methods: The contrast sensitivity and glare sensitivity were evaluated using by CGT-1000 for a non-refractive surgery group as control group(40 eyes) and a refractive surgery group(30 eyes) applied plano circle contact lenses, and pupil size was also measured. The correlation between contrast/glare sensitivity and the pupil size was analyzed. Results: In the refractive surgery group, contrast sensitivity in the range of high spatial frequency decreased with wearing circle contact lenses, and amount of decrease for the refractive surgery group was larger than for the control group. The correlation between pupil size and the change of contrast sensitivity was decreased by wearing circle contact lenses, and the correlation was lower in the refractive surgery group than the control group. Furthermore, the wear of circle contact lenses affected on glare sensitivity. In analyzing the change of glare sensitivity by pupil size, the glare was larger in the refractive surgery group than control group. Circle contact lenses in refractive surgery group were not fitted on the center of cornea. Conclusions: In the present study, it is suggested that the sufficient understanding and consideration about the decrease of contrast sensitivity and the increase of glare by wearing circle contact lenses after the refractive surgery is necessary.

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

Survey on Contact Lens Wear Status in Gyeonggido (경기도 지역 콘택트렌즈 착용실태 조사)

  • Song, Yun-Young;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.373-378
    • /
    • 2014
  • To investigate the wear status of contact lenses by analyzing care of contact lenses container and actual condition of people wearing contact lenses and in Gyeonggido. The results were based on a questionnaire survey of 200 people who are the students of the middle school, the high school and the college among the clients of opticians to purchase contact lenses for six months from January 2013 to July 2013. According to the poll, the highest number of those polled, 139 (55.16%) people, said they were wearing cosmetic color contact lenses. Female respondents and male respondents were in the proportion of 177 (88.5%) to 23 (11.5%), respectively. 37 people (18.5%) who responded said "yes" to the question of them sharing contact lenses and glasses. 103 people (51.5%) answered "no" to the question of regularly replacing their lens containers. 148 people (74%) answered "yes" to the question of having glasses in order to investigate contact lens wearers user rate of glasses. The highest number of respondents, 127 people (63.5%), said "middle school" was the first time that they wore contacts. Meanwhile, 65 people (43.92%) said they initiated wearing glasses at 4th-6th grades. It is considered that it is necessary using proper contact lenses suitable for the clients' eye health in order of vision correction, rather than for cosmetic purposes. The role of the optician is considered to be very important for the proper management of the appropriate contact lens hygiene and regular optical check-ups of the contact lens wearers.

Change of Corneal Shape with Soft Contact Lens Type (소프트콘택트렌즈의 유형에 따른 각막형태의 변화)

  • Woo, Chul-Min;Lee, Hyun Mee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2014
  • Purpose: This study was to investigate changes in the thickness of cornea, curvature of cornea, and aberration depending on the water contents, materials, and refractive power of contact lens. Methods: The differences in the corneal thickness between pre- and post-wearing the lenses were compared using 5 kinds of lenses. The changes in the corneal thickness, the curvatures of the anterior and posterior cornea, and high order aberration (HOA) before and after wearing the lenses were investigated at the center of the cornea, and the different distance and the direction away from the center of the cornea. For the equipments of measurement, ORB ScanII (Bausch & Lomb Inc, ver 3.14) was used to measure the corneal topography and thickness, and Zywave (Bausch & Lomb Inc, ver 5.20) was used to analyze the high order aberration. Results: Five (S1, S2, S3, T1, T2) of the lens was used for this study, excluding the lens T2 lens has four lenses and the thickness of the corneal shape, but the impact is minimal. In the case of the hydrogel soft contact lenses (T2 lens) with low oxygen permeability, the corneal thickness showed distinct increasing patterns. The high order aberration and coma aberration were most changed in the silicon hydrogel toric lens, while the depth of anterior was most changed in the hydrogel toric lens. Conclusion: Among the 5 kinds of contact lenses with different water contents, materials, and refractive power used for this study, the corneal shape change was small for the lenses with an oxygen permeability (Dk) of more than 28, and the largest for the lenses with a very low oxygen permeability.

The Comparative Analysis for the Progression of Dry Eyes Caused by Wearing Soft Contact Lenses(SCL) and Cosmetic Soft Contact Lenses(C-SCL) (소프트 콘택트렌즈와 미용 콘택트렌즈의 건성안 진행에 대한 비교분석)

  • Kim, Myoung-Jin;Hwang, Hye-Kyung;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.375-381
    • /
    • 2011
  • Purpose: The purpose of this research was to see how wearing either a SCL or a C-SCL effected the dryness of a person's eye depending on how long they wear either type of lens. Methods: This study was carried out on 52 subjects (104 eyes) who were all in their twenties and had previously experienced wearing contact lenses. All of these subjects were required to wear either a SCL or a C-SCL, which were made out of the same material, for three months. Contents such as the McMonnies Questionnaire survey, the blinking rate per min. and the Noninvasive tear break-up time test (NIBUT) were later conducted on the subjects for this study. Results: According to the results of the McMonnies Questionnaire, it was concluded that the longer the subject wore the SCL and C-SCL, the value of the measurements gradually increased. On the other hand, the results from the NIBUT concluded that the longer the subject wore the SCL, the value of the measurements eventually decreased. However, according to the measurements of the blink rate test, it was concluded that neither results had a significant change. Conclusions: It was concluded that long-term wearing of SCL and C-SCL could be the cause of the induction and progression of dry eyes.