• Title/Summary/Keyword: ophthalmic lens

Search Result 520, Processing Time 0.025 seconds

Preparation and Physical Properties of Silicone Hydrogel Ophthalmic Lens Containing Hydrophilic Monomer

  • Lee, Min-Jae;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.4
    • /
    • pp.261-266
    • /
    • 2016
  • The major physical characteristics of macromolecules used in silicone hydrogel ophthalmic lenses include optical transmittance, oxygen permeability, water content, and refractive index. For the preparation of highly functional silicone hydrogel lens materials, two silicone monomers were used in the presence of 2-hydroxyethyl methacrylate (HEMA) and hydroxypropyl methacrylate (HPMA). The samples containing HEMA and HPMA had oxygen transmissibility (Dk) values in the range of 73.38–50.98 × 10-11 (cm2/s) (mLO2/mL×mmHg) and 71.94–42.80 × 10-11 (cm2/s) (mLO2/mL×mmHg), respectively. Furthermore, the water contents of samples containing HEMA and HPMA were in the range of 32.73–34.67% and 31.94–33.74%, respectively, and the refractive indices were in the range of 1.4348–1.4364 and 1.4385–1.4407, respectively. Thus, silicone monomers containing HEMA and HPMA are expected to be useful for fabricating high-oxygen-permeability silicon hydrogel ophthalmic lenses.

Microbial contamination in contact lens care systems (Contact lens care system의 미생물 오염)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.57-63
    • /
    • 1996
  • The microbial contamination in contact lens care systems and conjunctivas of 40 asymptomatic cosmetic soft contact lens wearers was investigated. Patient ages ranged from 19 to 27(mean:22), most of them have used hydrogel contact lenses for less than 1 year, and the ages of lens cases were 1 weeks ~ 3 months (43 %) or 4~6 months (52%). Twenty-seven patients (67%) chemically disinfected their lenses and 8(20 %) used hydrogen peroxide, and 5 used heat to disinfect. Fourteen patients used commercial non-preserved saline, and 26(65%) were using commercial preserved saline. Sixty-two percent of the patients had bacterial contamination of lens case, and 17% had conjunctival contamination. The bacterial contamination rate was highest in lens cases, followed by unpreserved salines, disinfecting chemicals(non-hydrogen peroxide), and conjunctivas. The fungal contamination rate of cases and conjunctivas was 67% and 15%, respectively, and lens case, unpreserved saline, and conjunctiva seemed more susceptible to contamination. The use of hydrogen peroxide for disinfection rather than chemical disinfection was associated remarkabley with decreased contamination of solution itself, and there was no significant difference in contamination rates between hydrogen peroxide care system and other disinfecting systems. Five of lens cases(13%) and 2 conjunctivas(5%) were contaminated with Pseudomonas aeruginosa, and Candida albicans were isolated from 11cases (27%) and 5 conjunctivas (12%). Of the organisms that were contaminated lens cases and conjunctivas, Pseudomonas aeruginosa, Escherichia coli, Candida albicans, and Aspergillus fumigatus were isolated from lens cases, whereas Pseudomonas aeruginosa, Candida albicans, and Aspergillus fumigatus were recorvered from conjunctivas. Fortunately all of the these tested samples showed 0% of Acanthamoeba in this investigation.

  • PDF

The variation of visual acuity for a artificial myopia concerned with the fogging technique (운무법과 같은 인위적인 근시상태에서의 시력 변화)

  • Choi, Woon Sang;Park, Soo Bong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.43-47
    • /
    • 1996
  • For youths of both sexes which can read the letter chap of 1.0 acuity without lens, tests the fogging technique and examines the development of visual acuity. And compare the numerical function with the result of the variation of the blur circle on the retina when the power of the fogging lens varies. The variation of visual ac acuity for the fogging technique keeps constantly the balance for binocular.

  • PDF

Physical Properties of Ophthalmic Hydrogel Polymer Containing Zinc Oxide Nanoparticles

  • Sung, A-Young;Kim, Tae-Hun
    • Journal of Integrative Natural Science
    • /
    • v.6 no.2
    • /
    • pp.76-81
    • /
    • 2013
  • ZnO nanoparticles and vinyl pyridine were added to the mixture of MMA (methyl methacrylate), HEMA (2-hydroxy ethyl methacrylate) and NVP (N-vinylpyrrolidone) in a mould at various concentrations. Cross-linker EGDMA (ethyleneglycoldimethacrylate) and AIBN (azobisisobutyronitrile) initiator were finally added to the mixture and then heated at $80^{\circ}C$ for 60 min to prepare high-performance hydrogel ophthalmic lens. The physical properties of the hydrogel ophthalmic material were investigated by measuring the average value of refractive index, water content and optical transmittance. The refractive index of 1.429~1.450, water content of 34~41%, and visible transmittance of 78~90% were obtained. The material is possibly used to manufacture UV-block hydrogel contact lens.

Uniformity estimation mathod and application of thin film in Coating lenses (Coating 렌즈에서 박막의 균일성 평가 방법 및 적용)

  • Kim, Yong Geun;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.175-180
    • /
    • 2002
  • Use spctrophotometer to estimate thin film uniformity of lens, Compare, and analyze thin film uniformity availability selecting two peaks of Reflectance(R%) measuring on spectrum. Wavelength dependence's Reflectance in position of center, middle and edge of lens etc... obtain thin film's thickness (t) from Wavelength region (${\lambda}_1,{\lambda}_2$) of two peaks of Reflectance. $$t=\frac{1}{2(n^2-\sin^2{\theta})^{1/2}}{\times}\frac{{\lambda}_1{\lambda}_2}{{\lambda}_2-{\lambda}_1}$$ If Reflectance pattern is uniformity value in position of center middle of lens, edge etc... thin film has uniformity. Applied thin film uniformity estimation method to 1st layer $MgF_2$(n=1.38) coating lens. It was about thin film's thickness difference 360nm. Can analyze coating lens' thin film uniformity easily from Reflectance relationship measurement about Wavelength dependence.

  • PDF

The Research of Fitting Status of R.G.P Lenses Inspected by Optometrists in In-Cheon and Kyung-Gi Region (인천·경기지역 안경사들을 대상으로 한 R.G.P 렌즈 착용 실태 조사)

  • Kim, In-Suk;Kim, Young-Pil;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.27-33
    • /
    • 2007
  • This research investigated the effects of spherical and aspherical R.G.P lenses which was performed by optometrists in In-Cheon and Kyung-Gi region. This research survey included various questions such as the fitting status, after-care method, preliminary test. Results of the survey revealed that the optometriests sold the asperical and spherical lenses with a ratio of 7:3, respectively, and most of them did not cheked Topography, Fluorescein test by slit lamp biomicroscope, Tear Break up time test, Schirmer test and so on. And, with fitted R.G.P lenses symptoms like light odd-feeling, congestion, eye-stimulus, dimness and dryness were frequently reported. The purposes of this study are to search for the ideal fitting check of R.G.P lens and remind the most important preliminary test for contact lens fitting.

  • PDF

Development and Design of the Optical System of a Night Scope (Night Scope 광학계의 설계 및 개발)

  • Lee, Dong-Hee;Lim, Yang-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.11-17
    • /
    • 2004
  • We tried to design and manufacture a night scope which is used in the leisure sports field. The whole system consists of an IR light source part, an objective lens part, an intensifier tube part and an eye_piece lens part. We designed an objective lens part to the infinite object imaging optical-system with 80mm focal-length, 40mm effective-aperture and 14mm image-field-size of which the chromatic aberration is reduced by using materials of BK7 and FD4. The resolution of this system is about 25lines/mm at the 40% MTF value criterion. The eye_piece lens is adopted goods to be used commercially to save cost of production. The design technique which gets in this development will be utilized greatly in good developments of the dot, the sight and the day/night riflescope system at the hereafter.

  • PDF

Analysis of Adaptation for The first-time Progressive Lenses Glasses Wearers (누진렌즈 안경 처음 착용자의 적응도 분석)

  • Shim, Jun-Beom;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.117-122
    • /
    • 2011
  • Purpose: This study analyzed the factors related to adaptation of people who wears progressive lenses glasses for the first time. Methods: 463 presbyopia (Aged 41~78) without any ocular diseases with the progressive lens glasses were prescribed from 2010 to 2011 at B clinic in the Gwangju city. Progressive lenses adaptation were analyzed according to gender, age, distance refractive state, presbyopic addition, progressive lens design, the old glasses, astigmatism type, and anisometropia etc. High, mid and low-adapted groups were categorized as the status of wearing progressive lenses glasses, re-wearing, occasionally wearing and failed to weraing, respectively. Results: Men showed significantly higher adaptation (p=0.02) than women. Presbyopic addition (p=0.05) and progressive lens design (p=0.02) were statistically significant. However, it was found that there was so statistical significance for the factors of age, distance refractive state, the old glasses, astigmatism type, and anisometropia. Conclusions: According to the results of this study, when progressive lenses were prescribed, we should consider for adaptation gender, presbyopic addition, and progressive lens design etc.