• 제목/요약/키워드: operational calibration

검색결과 54건 처리시간 0.023초

Current Status of KASI Solar Radio Observing System

  • Bong, Su-Chan;HwangBo, Jung-Eun;Park, Sung-Hong;Jang, Be-Ho;Lee, Chang-Hoon;Baek, Ji-Hye;Cho, Kyung-Suk;Park, Young-Deuk;Gary, Dale E.;Lee, Dae-Young
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.82.1-82.1
    • /
    • 2011
  • Korea Astronomy and Space Science Institute (KASI) operates 2 solar radio observing facilities, e-CALLISTO (Earthwide network of Compound Astronomical Low-cost Low-frequency Instrument for Transportable Observatory) station and Korean Solar Radio Burst Locator (KSRBL). Although e-CALLISTO tracking system improvement.is underway, at least 6 new events were observed in this year. Software development for KSRBL is in progress. The antenna calibration software was updated and flux calibration software was developed. Also the automatic daily overview spectrum monitoring system is now operational. We found solutions to several problems including spurious data and FPGA board communication. However, a few minor unsolved hardware problems still persist. Meanwhile, at least 6 new events were observed by KSRBL in this year, and a comparative study with HXR is currently underway.

  • PDF

Basic Principles of the Validation for Good Laboratory Practice Institutes

  • Cho, Kyu-Hyuk;Kim, Jin-Sung;Jeon, Man-Soo;Lee, Kyu-Hong;Chung, Moon-Koo;Song, Chang-Woo
    • Toxicological Research
    • /
    • 제25권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Validation specifies and coordinates all relevant activities to ensure compliance with good laboratory practices (GLP) according to suitable international standards. This includes validation activities of past, present and future for the best possible actions to ensure the integrity of non-clinical laboratory data. Recently, validation has become increasingly important, not only in good manufacturing practice (GMP) institutions but also in GLP facilities. In accordance with the guideline for GLP regulations, all equipments used to generate, measure, or assess data should undergo validation to ensure that this equipment is of appropriate design and capacity and that it will consistently function as intended. Therefore, the implantation of validation processes is considered to be an essential step in a global institution. This review describes the procedures and documentations required for validation of GLP. It introduces basic elements such as the validation master plan, risk assessment, gap analysis, design qualification, installation qualification, operational qualification, performance qualification, calibration, traceability, and revalidation.

HSPF 유역모델을 이용한 낙동강유역 실시간 수문 유출 예측 (Operational Hydrological Forecast for the Nakdong River Basin Using HSPF Watershed Model)

  • 신창민;나은혜;이은정;김덕길;민중혁
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.212-222
    • /
    • 2013
  • A watershed model was constructed using Hydrological Simulation Program Fortran to quantitatively predict the stream flows at major tributaries of Nakdong River basin, Korea. The entire basin was divided into 32 segments to effectively account for spatial variations in meteorological data and land segment parameter values of each tributary. The model was calibrated at ten tributaries including main stream of the river for a three-year period (2008 to 2010). The deviation values (Dv) of runoff volumes for operational stream flow forecasting for a six month period (2012.1.2 to 2012.6.29) at the ten tributaries ranged from -38.1 to 23.6%, which is on average 7.8% higher than those of runoff volumes for model calibration (-12.5 to 8.2%). The increased prediction errors were mainly from the uncertainties of numerical weather prediction modeling; nevertheless the stream flow forecasting results presented in this study were in a good agreement with the measured data.

Transducer analysis and signal processing of PMSF with embedded bluff body

  • Yan, Xiao-Xue;Xu, Ke-Jun;Xu, Wei;Yu, Xin-Long;Wu, Jian-Ping
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.296-307
    • /
    • 2020
  • Permanent magnet sodium flowmeter (PMSF) have been used to measure the sodium flow in fast breeder reactors. Due to the effects of irradiation, thermal cycling, time lapse, etc., the magnetic flux density of the PMSF will decrease after being used in the reactor for a period of time. Therefore, it must be calibrated regularly. But some flowmeters that immersed in sodium cannot be removed for an off-line calibration, so the on-line calibration is required. However, the best online calibration accuracy of PMSF using cross-correlation analysis method was 2.0-level without considering the repeatability. In order to further improve this work, the operational principle of the transducer in PMSF is analyzed and the design principle of the transducer is proposed. The transducers were tested on the sodium flow loop to collect the experimental data. The signal characteristics are analyzed from the time and frequency domains, respectively. The cross-correlation analysis method based on biased estimation is adopted to obtain the flow rate. The verification experimental results showed that the measurement accuracy is 1.0-level when the flow velocity is above 0.5 m/s, and the measurement accuracy is 3.0-level when the flow velocity is in the range of 0.2 m/s to 0.5 m/s.

Finite element model calibration of a steel railway bridge via ambient vibration test

  • Arisoy, Bengi;Erol, Osman
    • Steel and Composite Structures
    • /
    • 제27권3호
    • /
    • pp.327-335
    • /
    • 2018
  • This paper presents structural assessment of a steel railway bridge for current condition using modal parameter to upgrade finite element modeling in order to gather accurate result. An adequate monitoring, such as acceleration, displacement, strain monitoring, is important tool to understand behavior and to assess structural performance of the structure under surround vibration by means of the dynamic analysis. Evaluation of conditions of an existing steel railway bridge consist of 4 decks, three of them are 14 m, one of them is 9.7 m, was performed with a numerical analysis and a series of dynamic tests. Numerical analysis was performed implementing finite element model of the bridge using SAP2000 software. Dynamic tests were performed by collecting acceleration data caused by surrounding vibrations and dynamic analysis is performed by Operational Modal Analysis (OMA) using collected acceleration data. The acceleration response of the steel bridge is assumed to be governing response quantity for structural assessment and provide valuable information about the current statute of the structure. Modal identification determined based on response of the structure play significant role for upgrading finite element model of the structure and helping structural evaluation. Numerical and experimental dynamic properties are compared and finite element model of the bridge is updated by changing of material properties to reduce the differences between the results. In this paper, an existing steel railway bridge with four spans is evaluated by finite element model improved using operational modal analysis. Structural analysis performed for the bridge both for original and calibrated models, and results are compared. It is demonstrated that differences in natural frequencies are reduced between 0.2% to 5% by calibrating finite element modeling and stiffness properties.

GOCI를 이용한 GOCI-II 근적외 밴드 교차보정 (Cross-Calibration of GOCI-II in Near-Infrared Band with GOCI)

  • 이은경;배수정;안재현;이경상
    • 대한원격탐사학회지
    • /
    • 제39권6_2호
    • /
    • pp.1553-1563
    • /
    • 2023
  • 천리안 해양관측위성 2호기(Geostationary Ocean Color Imager-II, GOCI-II)는 한반도 주변을 포함한 동북아 해역과 전구 영역을 관측하는 해색 위성으로 지난 10년간 운용된 GOCI의 임무를 이어받아 2020년부터 현재까지 운용되고 있다. 본 연구에서는 해색 데이터 산출에 있어 필수 과정인 대기보정 알고리즘을 개선하기 위해 GOCI 영상을 이용한 GOCI-II 근적외 파장(near-infrared, NIR) 밴드의 대리교정을 수행하였다. 이를 위해 NIR 밴드의 대기상층(top-of-atmosphere, TOA) radiance에 대한 교차보정 연구를 수행하였으며, 그 결과로 대리교정 상수를 도출하였다. 본 연구에서 도출된 대리교정 상수를 이용하여 보정한 결과 두 센서의 offset이 감소하였으며, ratio는 745 nm, 865 nm에 대해 각 1.02, 1.04에서 1.0, 0.99로 개선되었다. 이는 두 센서의 일관성이 높아진 것으로 판단된다. 또한, 대기 분자 산란 보정 반사도(Rayleigh-corrected reflectance, 𝜌rc)는 각각 5.62, 9.52% 증가하였다. 이로 인해 745 nm와 865 nm 𝜌rc의 비율의 차이가 발생했으며, 이는 대기보정 알고리즘 내 에어로졸 광 산란 보정 과정을 통해 모든 밴드의 대기보정 결과에 영향을 줄 수 있다. GOCI, GOCI-II 두 위성의 중복되는 운용 기간이 짧아 2021년 3월의 자료만을 사용하였으나, 향후 타위성과의 지속적인 교차보정 연구를 통해 개선이 가능할 것으로 사료된다. 또한 본 연구에서 도출된 NIR 밴드의 대리교정 상수를 적용하여 가시 채널의 대리교정을 수행하고, 해색 산출물의 정확도에 미치는 영향을 분석할 필요가 있다.

Truck Scale 용 Load Cell의 Smart Interface Board 개발 (Development of Smart Interface Board for Truck Scale Load Cell)

  • 박찬원;박종연;홍재용;최규석;안광희
    • 산업기술연구
    • /
    • 제15권
    • /
    • pp.83-91
    • /
    • 1995
  • This paper presents the design of a smart A/D conversion interface used for measuring the load of a truck. Since the load-cell sensor to be used is very sensitive for weight variation, the interface board must have the low-drift and the A/D conversion for accuracy. A new integrator and comparator has been developed to reduce the offset voltage and the drift current of operational amplifiers and has been adapted into the interface board. Also, a software algorithm has been developed to obtain the stable and accrurate A/D conversion. This software includes a RS-485 communication program to control the interface, which gives a capability of backing-up the calibration data and transferring control data. The test and evaluation of the designed interface has been shown as having the better performance compared to the other types of existing weighing systems and sensor instruments.

  • PDF

Introduction to the Validation Module Design for CMDPS Baseline Products

  • Kim, Shin-Young;Chung, Chu-Yong;Ou, Mi-Lim
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.146-148
    • /
    • 2007
  • CMDPS (COMS Meteorological Data Processing System) is the operational meteorological products extraction system for data observed from COMS (Communication, Ocean and Meteorological Satellite) meteorological imager. CMDPS baseline products consist of 16 parameters including cloud information, water vapor products, surface information, environmental products and atmospheric motion vector. Additionally, CMDPS includes the function of calibration monitoring, and validation mechanism of the baseline products. The main objective of CMDPS validation module development is near-real time monitoring for the accuracy and reliability of the whole CMDPS products. Also, its long time validation statistics are used for upgrade of CMDPS such as algorithm parameter tuning and retrieval algorithm modification. This paper introduces the preliminary design on CMDPS validation module.

  • PDF

다축 제어용 가진기의 구동소프트웨어 개발 및 보정에 관한 연구 (A Study on Operational Software Development and Calibration of Multi-Axis Vibration Testing Device)

  • 정상화;김재열;류신호
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.143-151
    • /
    • 2001
  • In the recent day, fatigue life prediction techniques play a major role in the design of components in the ground vehicle industry. Full scale durability testing in the laboratory is an essential of any fatigue life evaluation of components or structure of the automotive vehicle. Component testing is particularly important in todey's highly competitive industries where the design to reduce weight and production costs must be balanced with the necessity to avoid expensive service failure. Generally, Multi-axis durability testing device is used to carry out the fatigue test. In this paper, The operation software for simultaneously driving Multi-axis vibration testing device is developed and the input and output data are displayed in windows of PC controller with real time. Moteover the characteristics of the displacement and the load of Multi-axis actuators are calibrated separately.

  • PDF

Determination of Cholesterol by a Diode Laser/Fiber Optic Colorimetric Spectrometer

  • 김성호;남성만;변상길;윤신영;홍성식
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권4호
    • /
    • pp.389-392
    • /
    • 2000
  • A simple and inexpensive colorimetric spectrometer for determining total cholesterol has been developed,comprising a diode laser as the light sourcoptical fibers for the light guide and a photodiode as the detector.The stabilty and performance of the new system was investigated by obtaining the calibration curve for stan-dard cholesterol solutions. The total cholesterol in humanserum was also measured by the analyzer and com-pared with the value obtained by a conventional spectrometer. The results showed that the developed spectrometer was useful for the determination of cholesterol levels. The visible diodelaser used in the study exhibited good spectroscopic and operational properties for colorimetric absorption spectrometry and could be a key component for the development of a simple and economical analyzer.