• Title/Summary/Keyword: operation strategy

Search Result 1,791, Processing Time 0.033 seconds

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

Parallel Control of Shunt Active Power Filters in Capacity Proportion Frequency Allocation Mode

  • Zhang, Shuquan;Dai, Ke;Xie, Bin;Kang, Yong
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.419-427
    • /
    • 2010
  • A parallel control strategy in capacity proportion frequency allocation mode for shunt active power filters (APFs) is proposed to overcome some of the difficulties in high power applications. To improve the compensation accuracy and overall system stability, an improved selective harmonic current control based on multiple synchronous rotating reference coordinates is presented in a single APF unit, which approximately implements zero steady-state error compensation. The combined decoupling strategy is proposed and theoretically analyzed to simplify selective harmonic current control. Improved selective harmonic current control forms the basis for multi-APF parallel operation. Therefore, a parallel control strategy is proposed to realize a proper optimization so that the APFs with a larger capacity compensate more harmonic current and the ones with a smaller capacity compensate less harmonic current, which is very practical for accurate harmonic current compensation and stable grid operation in high power applications. This is verified by experimental results. The total harmonic distortion (THD) is reduced from 29% to 2.7% for a typical uncontrolled rectifier load with a resistor and an inductor in a laboratory platform.

The Assessment Items of Exhibitor Satisfaction In Trade Show (무역전시회 참가업체 만족도에 관한 연구)

  • Shin, Jai-Gi
    • International Commerce and Information Review
    • /
    • v.10 no.4
    • /
    • pp.203-219
    • /
    • 2008
  • This study shows the following results. First, the assessment items of the whole exhibition operation, workforce, counselor's ability, facility and environment were important analysis factors for exhibition recognition, quality of human operation and quality of exhibition facility and environment. Second, exhibition recognition was found to be the most significant factor that influenced exhibitor's cognitive achievement, exhibition employee operation and exhibition facility. Third, exhibitors' satisfaction simultaneously increased as exhibition recognition and employee operation quality were raised. However, exhibition facility didn't strongly influence exhibitors' satisfaction. Fourth, high exhibition recognition, employee operation and exhibition facility resulted in high cognitive achievement and exhibitor's loyalty. Fifth, exhibition recognition is a highly influential factor to mediate exhibitor's cognitive achievement and exhibitors' loyalty. It implied that exhibitors' cognitive achievement and satisfaction were significantly related to the exhibition quality factor. Moreover, it indicated the effective and efficient operational method to strengthen promotional strategy, enhance the quality of employee operation, exhibition facility and environment. Thus, the results suggest a new method to evaluate exhibitor's satisfaction in the exhibition industry.

  • PDF

Unit Commitment of a Microgrid Considering Islanded Operation Scenarios (독립운전 시나리오를 고려한 마이크로그리드의 최적 발전기 기동정지 계획)

  • Lee, Si Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.708-714
    • /
    • 2018
  • Islanded operation of a microgrid can ensure the reliable operation of the system when a large accident occurs in the main grid. However, because the generation capability of a microgrid is typically limited, a microgrid operator should take islanded operation risk into account in scheduling its generation resources. To address this problem, in this paper we have proposed two unit commitment formulations based on the islanding scenario that reflect the expected and worst-case values of the islanded operation risk. An optimal resource scheduling strategy is obtained for the microgrid operator by solving these optimization problem, and the effectiveness of the proposed method is investigated by numerical simulations.

NASA EOS DB Receiving System Development by KARI

  • Ahn, Sang-Il;Koo, In-Hoi;Yang, Hyung-Mo;Hyun, Dae-Hwan;Choi, Hae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.1
    • /
    • pp.37-42
    • /
    • 2003
  • Recently, KARI implemented the receiving and processing system for MODIS sensor data from NASA EOS satellites (TERRA and AQUA). This paper shows the development strategy considered, system requirement derived, system design, characteristic and test results of processing system. System operation concept and sample image are also provided. Implemented system was proven to be fully operational through lots of pass operations activities from RF signal reception to level-1 processing.

MILP model for short-term scheduling of multi-purpose batch plants with batch distillation process

  • Ha, Jin-Juk;Lee, Euy-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1826-1829
    • /
    • 2003
  • Fine chemical production must assure high-standard product quality as well as characterized as multi-product production in small volumes. Installing high-precision batch distillation is one of the common elements in the successful manufacturing of fine chemicals, and the importance of the process operation strategy with quality assurance cannot be overemphasized. In this study, we investigate the optimal operation strategy and production planning of a sequential multi-purpose plants consisting of batch processes and batch distillation with unlimited intermediate storage. We formulated this problem as an MILP model. A mixed-integer linear programming model is developed based on the time slot, which is used to determine the production sequence and the production path of each batch. Illustrative examples show the effectiveness of the approach.

  • PDF

국내 자동화 컨테이너터미널 개발 방향에 관한 연구

  • Choi Hyeong Rim;Park Nam Gyu;Park Byeong Ju;Yu Dong Ho;Kwon Hae Gyeong
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 2004.05a
    • /
    • pp.122-137
    • /
    • 2004
  • Automation of a container terminal is a world-wide tendency nowadays. The interest of ACT (Automated Container Terminal) is increasing more and more because of necessity of container terminal with higher competitive power and ultramodern equipment to down the cost and up the efficiency. ECT (Europe Combined Terminals) and CTA (Container Terminal Altenwerder) have studied a detailed technique for the operation of ACT. In Korea, many projects related to the development of ACT are working at present. However, indiscreet introduction of ACT may cause tremendous loss. Thus it is much important thing that we search relevant automation level or type for an environment In this study, we propose the necessary strategy in developing ACT through analyzing the present condition, automated equipments and property of operation at advanced An. If the strategy is applied in development of domestic ACT, we'll be able to build ACT with higher competitive power.

  • PDF

A Development of u-City Construction Model Considering the Reducing of Operating Cost (운영비 절감을 고려한 u-City 구축 모델 개발)

  • Park, Kwang-Ho;Kim, Dae-Young;Kim, Yun-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.33 no.4
    • /
    • pp.10-22
    • /
    • 2010
  • The first full-scale u-City operation has started in Dongtan u-City. As local cities take over and operate the u-City, unexpected issues arise such as securing the budget of operating costs and self-providing the costs with business models utilizing the u-City assets. The paper presents a strategy for solving these issues. The strategy provides a foundation(infrastructure) for long-term operation models which may reduce the long-term operating costs. In order to establish the economic operating framework of u-City, suggested are some cost-reduction models based on the operating costs structure. For each model, a base framework with comparative analysis of operating costs is provided. With these models, each u-City may select a relevant model according to the characteristics of it. We hope that the framework provides the foundation for efficient and sustainable u-City operations.

ROK Military Efforts for Jointness Improvement and Some Views for the Development of Its Joint Operational Capability (합동성 강화를 위한 각 군의 노력과 합동작전의 효율적 수행방안)

  • Park, Chang Kwoun
    • Strategy21
    • /
    • s.30
    • /
    • pp.5-30
    • /
    • 2012
  • Jointness is a core concept of ROK military reform plan. ROK military has pursued to transform its military organization and capability for enhancing jointness and joint operation after the 1990s. It has strengthened the organization of JCS(Joint Chief of Staffs), introduced joint education, and acquired modernized weapons and equipment proper for joint operation. The 1986 Glodwater-Nichols Act of the U.S. military and lessons of the recent war provided a good direction how ROK military should take measures to enhance jointenss. In fact, defense reform efforts for jointness has produced invaluable fruits for transforming industrial age military forces into information age one which possesses more strong combat capabilities and develops joint business for efficient defense management. Nevertheless, there are many issues ROK military should address for stepping up the jointness. This paper well analyzes practical problems and issues ROK military faces to develop jointenss and draws policy recommendations for the policy makers.

  • PDF

Control strategy against undesirable zone 3 protection with respect to voltage collapse (전압붕괴 측면에서의 Zone3 보호동작 억제를 위한 제어방안)

  • Song, Hwa-Chang;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.24-26
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions of relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. The proposed approach comes up with control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information which is valuable for both the timing and amount of control. The methodology is demonstrated through the modified New England 39-bus system.

  • PDF