• Title/Summary/Keyword: operation diagram

Search Result 241, Processing Time 0.024 seconds

Experimental Study on Heating Performance by Operation Combination of Heat Pump with 3 Indoor-Units (3실 열펌프의 운전조합에 대한 난방성능 실험연구)

  • Kim, Ju-Hyung;Kim, Ki-Young;Kwon, Young-Chul;Park, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4197-4203
    • /
    • 2013
  • In order to investigate the heating performance of multi-heat pump applying an inverter compressor, the experiment on heat pump with 3 indoor units was performed under the heating standard and heating low-temperature conditions. The performance data of heat pump with 3 indoor units were measured by the multi-psychrometric calorimeter. The operation characteristics and the behavior of the refrigerant cycle of the heat pump with 3 indoor units were understood from the heating capacity, heating COP, and P-h diagram by indoor-unit combination. The present experimental results show that the operating load and performance of the multi-heat pump depends on the indoor-unit combination. The heating capacity and heating COP of the low temperature condition were smaller than those of the standard one. Also the refrigerant cycles on indoor-unit combination were analyzed by using P-h diagram.

Evaluation of Blades Vibration Reliabilities of KGT-74 Small Gas Turbine (KGT-74소형 가스터빈 블레이드의 진동 신뢰성 평가)

  • 김영철;이동환;이안성
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.5
    • /
    • pp.410-415
    • /
    • 2004
  • To ensure a safe operation of the prototype KGT-74 kW small gas turbine, vibrational reliabilities of the compressor 1st, 2nd, and 3rd stages and turbine blades have been estimated and reviewed. FE analyses have been carried out to obtain the natural vibration characteristics of the blades, and impact modal testings have been performed on every each one of the blades to measure their 1st natural frequencies. Then, the Campbell diagram analyses have been carried out to judge the safety of the blades from resonant failures up to 6k harmonics. Results show that the compressor 1st stage blade is exposed to a potential resonant failure with 3k harmonic around a rated speed of 30,000 rpm but that the other compressor 2nd and 3rd stages and turbine blades are safe from resonant failures. Finally, 27,900 rpm is selected as the safe operation limit for the KGT-74 ㎾ gas turbine relative to the blade vibrations.

Evaluation of Blades Vibration Reliabilities of KGT-74 Small Gas Turbine (KGT-74 소형 가스터빈 블레이드의 진동 신뢰성 평가)

  • 이안성;김영철;이동환;나언주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.297-302
    • /
    • 2003
  • To ensure a safe operation of the prototype KGT-74 ㎾ small gas turbine, vibrational reliabilities of the compressor 1st, 2nd. and 3rd stages and turbine blades have been estimated and reviewed. FE analyses have been tarried out to obtain the natural vibration characteristics of the blades, and impact modal testings have been performed on every each one of the blades to measure their 1st natural frequencies. Then, the Campbell diagram analyses have been carried out to Judge the safety of the blades from resonant failures up to 6k harmonics. Results show that the compressor 1st stage blade is exposed to a potential resonant failure with 3k harmonic around a rated speed of 30,000rpm but that the other compressor 2nd and 3rd stages and turbine blades are safe from resonant failures. Finally. 27,900 rpm Is selected as the safe operation limit for the KGT-74 ㎾ gas turbine relative to the blade vibrations.

  • PDF

A Study on Variation of the Dynamic Characteristic of Supply Voltage According to the Track Environment and Spatial Distribution as Driving of Urban Transits (도시철도차량의 운행 선로환경 및 공간적 분포에 따른 공급전압 동특성 변화)

  • Kim, Yang-Su;Chang, Chin-Young;Lee, Ki-Sik;Koo, Kyung-Wan;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1380-1386
    • /
    • 2012
  • It is important to consider supply voltage stability in case of design and construction of a substation at electric railway because a urban transit is operated by electricity and it is driven simultaneous in the same section. This paper study on variation of the dynamic characteristic of supply voltage according to the track environment and spatial distribution as driving of urban transits. Simulation tool, TOM(Train Operations Model) software is used to ensure stability of feeder system being used around the world. As results of simulation, voltage of the contact wire is in limits on driving operation diagram of urban transits. Also, it has confirmed that there is a correlation the phase current, depending on the speed of urban transit and track environment like vertical gradients and curve radius.

A Development of Punctuality Index for Bus Operation Using Time-space Diagram (시공도를 이용한 버스운행 정시성 지표개발)

  • Yang, Ji-Young;Kim, Young-Chan;Kim, Seung-Il
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.8 s.86
    • /
    • pp.129-138
    • /
    • 2005
  • Since Successive introduction of BMS(Bus Management System) into the local governments has been able to collect each bus data on the road and valuate the bus operation by the quantitative index not qualitative index. we need a study on punctuality index for evaluation of service level for bus operation using bus location information. We propose punctuality index for bus operation using time-space diagram and valuate the index by application to real bus data.

A Study of Label Intimacy Applied by Applicant's Code-Expansion Rule (구직자 코드확장 규칙을 적용한 레이블 친숙성 연구)

  • Yang, Seung-Hae;Jeong, Eun-Hee;Lee, Byung-Kwan
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.1
    • /
    • pp.57-62
    • /
    • 2010
  • This paper proposes two methods for the construction of job offer and job hunting information in order to supply an environment that can easily connects to job hunting information. First, the database expansion, category rules and ERD(Entity Relation Diagram) are designed for the construction of job hunting site with real example. Second, the prime number labeling rules are designed for the strong intimacy of label rules. Therefore, according to using the systematic and regular rules when we design and construct a database, the consistency and efficiency are improved in the database being constructed and being operated. And the convenience of application program development and operation are easily provided. In addition, the proposed code-expansion rule can be defined and be standardized in the domestic and foreign job offer and job hunting information provision agency.

  • PDF

A study on the Characteristics of each Period of Diagrams appearing in Modern Architecture (현대건축에서 나타나는 다이어그램의 시대별특징에 관한 연구)

  • Moon, Ko Ri;Park, Ji Hun;Lee, Seung Yong
    • Smart Media Journal
    • /
    • v.11 no.8
    • /
    • pp.37-46
    • /
    • 2022
  • In the design process of modern architecture, diagrams are most commonly used as tools of explanation and creation. Many architects use diagrams in the process of explaining or creating their own works, and the concept of programs and diagrams expressing them are accepted by audiences as part of creative work in the process of actual architectural design beyond the role of a medium. Therefore, the purpose of this study is to analyze the various uses of architects through diagrams in the construction process and the operation process of diagrams applied in the design process by defining diagrams by era as a tool to show the process of building space over the past 30 years.

Zero-suppressed ternary decision diagram algorithm for solving noncoherent fault trees in probabilistic safety assessment of nuclear power plants

  • Woo Sik Jung
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2092-2098
    • /
    • 2024
  • Probabilistic safety assessment (PSA) plays a critical role in ensuring the safe operation of nuclear power plants. In PSA, event trees are developed to identify accident sequences that could lead to core damage. These event trees are then transformed into a core-damage fault tree, wherein the accident sequences are represented by usual and complemented logic gates representing failed and successful operations of safety systems, respectively. The core damage frequency (CDF) is estimated by calculating the minimal cut sets (MCSs) of the core-damage fault tree. Delete-term approximation (DTA) is commonly employed to approximately solve MCSs representing accident sequence logics from noncoherent core-damage fault trees. However, DTA can lead to an overestimation of CDF, particularly when fault trees contain many nonrare events. To address this issue, the present study introduces a new zero-suppressed ternary decision diagram (ZTDD) algorithm that averts the CDF overestimation caused by DTA. This ZTDD algorithm can optionally calculate MCSs with DTA or prime implicants (PIs) without any approximation from the core-damage fault tree. By calculating PIs, accurate CDF can be calculated. The present study provides a comprehensive explanation of the ZTDD structure, formula of the ZTDD algorithm, ZTDD minimization, probability calculation from ZTDD, strength of the ZTDD algorithm, and ZTDD application results. Results reveal that the ZTDD algorithm is a powerful tool that can quickly and accurately calculate CDF and drastically improve the safety of nuclear power plants.

A Study on the Automatic Start-up of a Drum-type Boiler Using Fuzzy Logic (퍼지 논리를 이용한 드럼형 보일러의 자동기동에 관한 연구)

  • ;;;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.2
    • /
    • pp.87-96
    • /
    • 1993
  • Because of the complexity, nonlinearity and long-time delay of power plant, the star-up operation of a fossil power plant is very difficult to automate. So the start-up operation is always carried out by the skilled human operators, who utilize their knowledges and experiences for the predesigned start-up schedules and procedures. In this paper, a fuzzy logic controller is designed for the start-up operation of the power plant. And the operators experiences are modeled in terms of fuzzy sets and variables. To validate the controller, a drum-type boiler of the Seoul Power Plant is constructed via the signal flow diagram. Using the model, the suggested automatic start-up operation is verified, and the results are also presented.

  • PDF

FPSO Cargo Pumping 시스템 가상운전 시스템 개발

  • Nam, Ki-Il;Han, Ki-Hun;Chang, Kwang-Pil;Oh, Tae-Young;Chang, Dae-Jun;Song, Seok-Ryong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.251-252
    • /
    • 2006
  • This study developed the virtual operation system for the hydraulic pump system for marine usage. The scope of this study is to develop a process dynamic simulation model for the hydraulic pump system for marine usage, to investigate the process dynamic characteristics using the models, to accomplish the logic diagram for the PLC control and to achieve a human-machine interface (HMI) for the convenience of operators to monitor and control the process. The virtual operation system provides a virtual operation environment for the pumping system, enabling the operators to simulate the change of process variables. The system will assist in developing advanced control logics and then optimal design of the system.

  • PDF