Current Control Method of WRSM in High-speed Operation Range

  • Lee, Jae-Jun;Lee, Ki-Doek;Jang, Ik-Sang;Lee, Sung-Gu;Chae, Woong-Chan;Lee, Hyung-Woo;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2052-2056
    • /
    • 2015
  • This Paper analyzes the characteristics of the WRSM in high-speed operation range. To verify the control characteritics of various WRSM models, the relative position of the central point of current limit circle and voltage limit ellipse is defined as M value and 3 models according to Mmax value are designed through inductance change. Through the designed models, the current control method of 3-variables control for maximum power especially in high-speed operation range is presented.

The Stablized Control Method for The Voltage Source Inverter Fed Induction Motor Driver (전압형 인버터로 구동되는 유도기의 안정화 제어)

  • Ro, S.C.;Lee, H.W.;Lee, O.G.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.567-570
    • /
    • 1989
  • A constant V/F control system of voltage contrlled PWM inverter has a unstable operation of the low- speed and the light-load. In this paper, the authors propose stability control with idealized operation of induction motor by the neglect of primary leakage inductance and resistance. Also ldealized operation system is adopted voltage error, feed back impedance circuit, and increasing resistance from dead time of switching is compensated by the soft ware with u-processors. The proposed simulation of the idealized control method is proved at the low-speed operation for three phase induction motor.

  • PDF

Time-temperature relationships of mushroom and cheese omelet in airline catering operations (항공기내식의 품질관리를 위한 연구 - 오믈렛 생산과정의 소요시간 및 온도관계를 중심으로 -)

  • 이영희
    • Journal of the Korean Home Economics Association
    • /
    • v.23 no.4
    • /
    • pp.61-68
    • /
    • 1985
  • This study was conducted in a Korean airline catering operation where about 8, 000~10, 000 in flight meals per day were served. Time ad temperature observations were made in an actual airline catering operation to determine critical control points in mushroom and cheese omelet production, and to provide guidelines for the effective quality control programs of the airline catering operation. All data collection was replicated three times. Time and temperature data were collected by using standard instruments throughout the process sequence. Most phases of the food prodct flow were identified as critical control points. Holding phases of after cooking, and before and after reheating need a special attention, since foods were held at room temperature. Several guidelines were suggested for the effective quality control programs for the airline catering operation.

  • PDF

FPSO Cargo Pumping 시스템 가상운전 시스템 개발

  • Nam, Ki-Il;Han, Ki-Hun;Chang, Kwang-Pil;Oh, Tae-Young;Chang, Dae-Jun;Song, Seok-Ryong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.251-252
    • /
    • 2006
  • This study developed the virtual operation system for the hydraulic pump system for marine usage. The scope of this study is to develop a process dynamic simulation model for the hydraulic pump system for marine usage, to investigate the process dynamic characteristics using the models, to accomplish the logic diagram for the PLC control and to achieve a human-machine interface (HMI) for the convenience of operators to monitor and control the process. The virtual operation system provides a virtual operation environment for the pumping system, enabling the operators to simulate the change of process variables. The system will assist in developing advanced control logics and then optimal design of the system.

  • PDF

Voltage Control Strategy for Maximum Torque Operation of Stator-Flux-Oriented Induction Machine Drive in the Field-Weakening Region (약계자 영역에서 유도 전동기의 고정자 자속 기준 최대 토크 운전을 위한 전압 제어 기법)

  • Kim, H.J.;Yu, J.S.;Won, C.Y.;Kim, E.J.;Jo, H.K.;Kim, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.30-32
    • /
    • 2005
  • In this paper, voltage control strategy for maximum torque operation of stator flux-oriented induction machine drive in the field-weakening region is proposed. In a conventional stator flux-oriented (SFO) induction machine drive system of the maximum torque capability cannot be obtained. The field-weakening method is used to vary the stator-flux reference in proportion to the inverse of the rotor speed. The proposed algorithm, based on the voltage control strategy, ensures the maximum torque operation over the field-weakening region. The proposed algorithm, voltage control strategy for maximum torque operation of capability, which is insensitive to the variation of machine parameters In the field-weakening region. The proposed algorithm is verified by simulation.

  • PDF

Test running and Development of Automatic/Driverless Operation Equipment for EMU (도시철도차량용 자동/무인운전제어장치(ATO) 개발 및 본선시운전에 관한 연구)

  • Han, Seong-Ho;Ahn, Tae-Ki;Lee, Su-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1451-1453
    • /
    • 2000
  • The automatic/driverless operation which are great important techniques in metro railway are required to increase higher safety, greater reliability, and transport capacity. To satisfy such demands, we must have the system design and testing technique for the railway system operation. These techniques are related to the onboard train control and communication systems which include TCMS(Train Control and Monitoring System), ATO(Automatic train Operation), ATC(Automatic train Control), and TWC(Train to wayside communication). These sub-systems must be interfacing with not only each others but also the signal system on the ground. We tested the train control system on the 7 line that has been developed on the basis of the standardized type EMU for korea railway systems.

  • PDF

Communication Consecutive Test of Train Oriented Control System for Wayside Equipment Control (선로변 시설물 차상제어를 위한 차상중심 열차제어시스템의 통신 연속성 시험)

  • Baek, Jong-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.703-712
    • /
    • 2014
  • To improve the efficiency and safety of railway systems, the train control system has been considerably evolved from the ground-equipment-based control system (e.g. track circuit, interlocking system, etc.) into the on-board-equipment-based control system. In addition, this train control system enables the rolling stock to intelligently control the trackside facilities by introducing the information and communication technologies (ICT). Accordingly, since the ICT-based train control system makes the railway system be simplified (i.e. the heavy ground-equipment can be removed), the efficient and cost-effective railway system can be realized. In this paper, we perform the feasibility test of the ICT-based train control system via a simulation. To this end, we have developed the prototypes of the on-board controller and wayside object control units which control the point and crossing gate and performed the integrated operation simulation in a testbed. In this paper, before the field test of the on-board-controller-based train control system, we perform the Consecutive operation test for prototypes of the on-board controller, wayside object control units and local control computer.

Power Control Method for Reducing Circulating Current in Parallel Operation of DC Distribution System

  • Shin, Soo-Cheol;Lee, Hee-Jun;Kim, Young-Ho;Lee, Jung-Hyo;Lee, Taeck Kie;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1212-1220
    • /
    • 2013
  • In general, for a large power system like DC distribution system for buildings, several power converters are modularized for parallel operation. However, in parallel operation, inconsistency of parameters in each module causes circulating current in the whole system. Circulating current is directly related to loss, and, therefore, it is most important for the safety of the power system to supply the suitable current to each module. This paper proposes a control method to reduce circulating current caused during parallel operation. Accordingly, the validity of parallel operation system including response characteristics and normal state was verified by simulation and experiment result.

Development of Simulation Model Based Optimal Start and Stop Control Daily Strategy (시뮬레이션 모델기반 냉난방 설비 일별 최적 기동/정지 제어기법 개발)

  • Lee, Chanwoo;Koo, Junemo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.1
    • /
    • pp.16-21
    • /
    • 2018
  • This work aims to develop a platform to investigate the effect of operation schedules on the building energy consumption and to derive a simulation model based optimal start and stop daily strategy. An open-source building energy simulation tool DOE2 is used for the engine, and the developed simulation model is validated using ASHRAE guideline 14. The effect of late-start/early-stop operation of HVAC system on the daily building energy consumption was analyzed using the developed simulation model. It was found that about 10% of energy consumption cut was possible using the control strategy for an hour of advance of the stop operation, and about 3% per an hour of delay of the start operation.

Dynamics Modeling and Operation Simulation for the Simulation of Abrupt Faults in the Boiler Drum Level Control System of a Fossile Power Plant (돌발성 이벤트 형태의 고장 시뮬레이션을 위한 화력발전소 보일러 드럼 수위 제어 계통의 다이나믹스 모델링 및 운전 시뮬레이션)

  • Kim, Jeong-Geun;Kim, Jae-Hwa;Jang, Tae-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.2
    • /
    • pp.59-68
    • /
    • 2002
  • This Paper presents the dynmics modeling and the operation simulation of the 500 MW drum-type boiler and its control system hosted in the Boryung Power Plant unit #1 and #2. The fidelity of the modeling and the operation simulation is well verified by their agreement with the actual data obtained form the plant operation. As a plant signal generator for the various operation patterns and fault situations, the simulation environment will be utilized to develope the fault detecting signal processing algorithms.