• Title/Summary/Keyword: operating temperature measurement

Search Result 195, Processing Time 0.026 seconds

A Study on the Emission Characteristics in 4 Stroke Large Propulsion Diesel Engine (4행정 대형 디젤엔진의 배기 배출특성에 관한 연구)

  • 김현규;전충환;장영준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.5
    • /
    • pp.38-45
    • /
    • 2001
  • Environmental protection on the ocean has been interested and nowadays the International maritime organization(IMO) has advanced on the prevention of air pollution from ships. This study presents the emission characteristics of 4 stroke propulsion diesel engine in E2 cycle (constant speed) and E3 cycle (propeller curved speed). Also the effects of important operating parameters in terms of intake air pressure and temperature, and maximum combustion pressure are described on the specific emissions. Emissions measurement and calculation are processed according to IMO technical code. The results show that NOx emission level in E3 cycle is higher than E2 cycle due to lower engine speed and lower maximum combustion pressure by retarding fuel injection timing. Intake air temperature has strong influence on NOx emission production. And CO, HC emissions are not affected by maximum combustion pressure and intake air pressure and temperature.

  • PDF

Measurement and Prediction of Autoignition Temperature of n-Propanol+n-Decane Mixture (노말프로판올과 노말데칸 혼합물의 최소자연발화온도 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.55-61
    • /
    • 2014
  • The autoignition temperature (AIT) of a material is the lowest temperature at which the substance will spontaneously ignite in the absence of an external ignition source such as a spark or flame. The AIT may be used as combustion property to specify operating, storage, and materials handling procedures for processs safety. This study measured the AITs of n-Propanol+n-Decane system from ignition delay time(time lag) by using ASTM E659 apparatus. The AITs of n-Propanol and n-Decane which constituted binary system were $435^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-Propanol+n-Decane system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D(average absolute deviation).

Evaluation of Component Performance of a Commercial Micro Gas Turbine (상용 마이크로 가스터빈의 구성부 성능분석)

  • Lee, J.J.;Yun, J.E.;Kim, T.S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.331-337
    • /
    • 2005
  • This study aims at evaluation of component performance of a commercial micro gas turbine by detailed measurements of various system parameters. A test facility to measure performance of a micro gas turbine was set up. Performance parameters such as turbine exit temperature, exhaust gas temperature, engine inlet temperature, compressor discharge pressure and fuel flow rate were measured. Variations in measured data and estimated performance parameters were analyzed. In addition to overall engine performance, component characteristic parameters including the turbine inlet temperature, the compressor efficiency, the turbine efficiency, the recuperator effectiveness were estimated. Behaviors of the estimated characteristic parameters with operating condition change were examined.

  • PDF

Improving the Measurement Uncertainty of Altitude Test Facility for Gas Turbine Engines (가스터빈엔진 고공성능시험설비의 측정불확도 개선)

  • Lee, Dae-Sung;Yang, In-Young;Jun, Yong-Min;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1496-1502
    • /
    • 2002
  • An Altitude Engine Test Facility(AETF) was built at the Korea Aerospace Research Institute in October 1999 and has been being operated for altitude testing of gas turbine engines of 3,000 Ibf class or less. The AETF has been calibrated using several engines such as J69 of Teledyne Co. as a facility checkout engine. Uncertainty analyses on the air flow rate and thrust were performed using the test results, according to ASME PTC 19.1-1998. Several modifications on the facility and test method were made in order to improve the measurement uncertainty to a satisfactory level over the whole operating envelop. Spatial distributions of pressure and temperature were measured, sensors were substituted by more accurate ones, inlet duct was modified to refine the flow quality, and pressure control logic was revised to remove the cell pressure fluctuation. As a result, the uncertainty of the air flow measurement was improved by 0.1% over all the test conditions, and the net thrust measurement by up to 3%. The improved measurement uncertainties of air flow and thrust are 0.68~O.73% and 0.4~1.3%, respectively.

Phase-Resolved CARS Temperature Measurement in a Lean Premixed Gas Turbine Combustor (I) -Effect of Equivalence Ratio on Phase-Resolved Gas Temperature- (CARS를 이용한 희박 예혼합 가스터빈 연소기내 온도 측정 (I) -연료/공기 혼합정도가 위상별 온도에 미치는 영향-)

  • Lee Jong Ho;Jeon Chung Hwan;Park Chul Woong;Hahn Jae Won;Chang Young June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1184-1192
    • /
    • 2004
  • Experimental investigations were carried out in an atmospheric pressure, optically accessible and laboratory-scale dump combustor operating on methane gas. The objective of this study was to obtain the phase-resolved gas temperatures at different phases of the oscillating pressure cycle during unstable combustion. CARS temperature measurements were made at several spatial locations under lean premixed conditions to get the information on temperature field within the combustor. Also the effect of incomplete fuel-air mixing on phase-resolved temperature fluctuation was investigated. Results including phase-resolved averaged temperature, normalized standard deviation and temperature probability distribution functions (PDFs) were provided in this paper. Temperature PDFs gave an insight on the flame behavior. And strong correlation between phase-resolved temperature profile and pressure cycle was observed. Results of the phase-resolved high temperature gave an additional information on the perturbation of equivalence ratio at flame as well as the effect of mixing quality on NOx emission characteristics.

Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method (초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.18-26
    • /
    • 2000
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operating conditions such as high temperature and high pressure for an extended period time. Conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also these techniques have low practicality and applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens(Cr-Mo alloy steels) were carried out for the purpose of evaluation for creep damage. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradation tests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens. we conformed that both the sound velocity decreased and attenuation coefficient linearly increased in proportion to the Increase of creep life fraction($\Phi$c).

  • PDF

Quench Current Measurement of High Temperature Superconducting Coils Cooled by Conduction (전도냉각방식을 이용한 고온초전도 코일의 퀜치전류 측정)

  • Sohn, M.H.;Kim, S.H.;Baik, S.K.;Lee, E.Y.;Lee, J.D.;Kwon, Y.K.;Kwon, W.S.;Park, H.J.;Moon, T.S.;Kim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1252-1254
    • /
    • 2005
  • High Tc superconducting(HTS) model coil was prepared. Current-voltage(I-V) characteristic curves of model coil, sub-coils and joints were investigated at 77K and other some temperatures. Cooling system for characteristics measurement was made by using G-M cryocooler. At 77K, quench current(Iq) of model coil was 43.9A and the lowest Iq of sub-coils was 38.8A. At 55K, sub coil SP #06 was 106A. So, 100A was chosen as the operating current at 55K with margin. Joule heat of model coil was 0.65W at 100A, operating current and 58K. Joint resistances between sub-coils were about $70n{\Omega}$ at 77K and about $30n{\Omega}$ at 55K.

  • PDF

The Design and Implementation of remote measurement using Internet Embedded Module (인터넷 엠베디드 모듈을 이용한 원격 계측의 설계와 구현)

  • Lee, Hee-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.9 no.5
    • /
    • pp.183-190
    • /
    • 2008
  • Recently, according to development of information-oriented society, internet application technology on electricity electron controled technology fields are diversified and the necessity of remote measurement by internet is gradually increased. In this paper, to meet in these necessity we design and implementation of remote measurement system using internet embedded module, which was developed for on-line measurement of various kinds of analogue data. This system is consisted of two parts greatly, hardware module for measurement and software module to control it. The advantage of this system is that users can acquisition the remote data of temperature and illumination etc. without extra serve pc easily. In order to test the validity of the proposed system, we examine the response and operating characteristic about several states. As a result of the test, we proved the effectiveness of it.

  • PDF

Oxygen sensor for the low temperature-measurement using yttria stabilized zirconia(YSZ) electrolyte and Ag electrode (YSZ 전해질과 은 전극을 이용한 저온 산소센서에 대한 연구)

  • Yang, Young-Chang;Park, Chong-Ook
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.97-101
    • /
    • 2006
  • Silver electrode having a high Electrocatalytic activity is oxygen-permeable electrode, in which oxygen ad-atoms are adsorbed and moved toward YSZ electrolyte by bulk diffusion. It is the different point in comparison to usual porous electrodes, especially platinum, which react with oxygen only in TPBs(Three Phase Boundaries). Also ad-atoms at TPBs of Pt are diffused to YSZ electrolyte by interfacial diffusion mechanism. These properties were used for turning down the operating temperature of YSZ from over $600^{\circ}C$ to below $450^{\circ}C$. The different heat-treatment temperature between a working electrode and a reference electrode suppresses the formation of silver oxides and reduces a volatility of Ag as well. Above all, these own characteristics and special processes of Ag improved a long-term stability of a oxygen sensor.

Characterization of A Catalystic Gas Sensor for Measuring Heat Content of Natural Gas (천연가스의 열용량을 측정하기 위한 촉매가스센서의 특징)

  • Lee K. Y.;Maclay G. J.;Stetter J. R.
    • 한국가스학회:학술대회논문집
    • /
    • 1997.09a
    • /
    • pp.229-235
    • /
    • 1997
  • A low power (300 mW) catalytic bead combustible gas sensor is developed and utilized with a computer controlled sampling system for measuring heat content of natural gas. The heat content of gas is proportional to the change in the energy required to exposure to the sample of combustible gas. The heat content of natural gas samples ranging 36.30 - 39.88 MJ/$m^3$ is measured in the range of approximately $1\%$ error, which is comparable to its nominal heat content. Each gas has a slightly different curve of sensitivity vs. sensor temperature. Thus there Is no temperature at which all sensitivities are equal. In calibration process the choice of a optimum operating temperature is an important factor that influences the overall performance of the measurement system.

  • PDF