• 제목/요약/키워드: operating temperature

검색결과 3,662건 처리시간 0.029초

PEMFC 1차원 시뮬레이션 검증을 위한 실험적 연구 (An Experimental Study of Verification for PEMFC's 1-Dimensional Simulation)

  • 문철언;안성율;양장식;최경민;김덕줄
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.191-195
    • /
    • 2007
  • In this study, we estimated the performance of PEMFC's unit cell as changing operating temperature in different inlet humidity condition at cathode side but anode dry, and tried to match experimental results with 1-dimensional simulation. We used $Nafion^{\circledR}112$ membrane and a self-manufactured PEMFC with active area of $25cm^{2}$ was used in this study. The range of operating temperature was $40{\sim}70^{\circ}C$ and oxygen through bubbled humidity chamber was supplied $0{\sim}80$% humidity condition as changing water temperature in humidity chamber. For figuring out governing equations, represent water contents in electrolyte membrane, the linear forward difference method was applied about time progress and quadratic central difference method was used about space progress. It was assumed that pressure terms were linearly changed due to thin electrolyte membrane. In low operating temperature condition, $40{\sim}60^{\circ}C$, increasing temperature rarely effected cell performance but we can see performance drop at $70^{\circ}C$. By modifying Henrry's constant and/or diffusion coefficient, the modified one-dimensional model was accomplished for calculation.

  • PDF

화학선 증착법에 의한 $MgF_2$ 박막제조 (Chemical Beam Deposition of $MgF_2$ Thin Films)

  • 박보현;백성기
    • 한국세라믹학회지
    • /
    • 제33권3호
    • /
    • pp.299-306
    • /
    • 1996
  • We invesgated the fesibility of thin films deposition by pyrolysis of metalorganic precursors using chemical beam deposition (CBD) process. We attempted to understand the effects of deposition variables such as substrate temperature operating pressure effusion cell temperature and H2 partial pressure on the properties of MgF2 grown by CBD. Mg(tfac)2 was used as a precursor. MgF2 thin films were always grown in an amorphous state and crystallized bypost-annealing. he higher the substrate temperature and the lower the operating pressure the less the impurities I the deposited MgF2 thin films. H2 gas has to be supplied for the pyrolitic reaction of Mg(tfac)2 decomposition. MgF2 films annealed in H2 have lower C impurity than those annealed in O2. But their crysatllinity was independent of annealing atmosphere. The optimum conditions for the prepara-tion of MgF2 films by CBD process were as following : The substrate temperature 55$0^{\circ}C$ the operating pressure 10-4 torr; effusion cell temperature 21$0^{\circ}C$ the percentage of H2 100% Post-annealing in H2 gas was required to remove residual carbon and to form MgF2 crystalline phase.

  • PDF

유속에 따른 열선의 과열비 조정을 통한 열선유속계의 감도향상에 관한 연구 (Sensitivity Enhancement of a Hot-Wire Anemometer by Changing Overheat Ratio with Velocity)

  • 이신표;고상근
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2678-2689
    • /
    • 1995
  • In this study, a new hot-wire anemometer which has greater sensitivity than that of a constant temperature anemometer (CTA) was proposed. In contrast to CTA, the wire working resistance of the new anemometer increases with flow velocity, that is, the operating mode of the wire becomes variable temperature. The variable temperature anemometer(VTA) was made by substituting a voltage controlled variable resistor such as photoconductive cell or transistor for one of the resistors in the bridge. By positively feeding back the bridge top signal to the input side of these electronic components, the wire overheat ratio could be increased with velocity automatically. Static response analyses of the VTA, constant voltage anemometer (CVA) and CTA were made in detail and calibration experiments were performed to validate the proposed operating principle. The wire operating resistance of the CVA decreases with velocity and this leads to lower sensitivity than that of a CTA. But the sensitivity of the newly proposed VTA is superior to that of a CTA, since the wire overheat ratio increases with velocity. Consequently, it is found that the major factor that is responsible for large sensitivity of a VTA is not the working resistance itself but the change of the wire working resistance with velocity.

나트륨 히트파이프의 작동 특성 및 성능에 관한 실험적 연구 (An Experimental Study on the Operational Characteristics and Performance of the Sodium Heat Pipe)

  • 강환국;이동찬;박상운;송지혁;유정현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.311-316
    • /
    • 2005
  • The experimental study for an operational characteristics and performance of the sodium heat pipe were carried out. For an experiment. the heat pipe which is 1000mm length and 25.4mm diameter of stainless steel container with 50 mesh of screen wick using sodium as a working fluid is manufactured and tested as functions of heat flow rate, inclined angle and operating temperature. The test results are as follows. During the start-up. frontal start up was observed because of the vapor density increasing as increased the hot zone. Also, the heat pipe showed uniform temperature over than $420^{\circ}C$ of the operating temperature. The average heat transfer coefficient increased as the heat flux and the vapor temperature increase, and the range of the total thermal resistance was 0.075-0.04 $^{\circ}C/W$ at the 12-53.55 $kW/m^2$ of heat flux and $500-750^{\circ}C$of operating temperature. The maximum heat flow rate was 750W at the 10 degree of top heating mode.

  • PDF

THERMAL HYDRAULIC ISSUES OF CONTAINMENT FILTERED VENTING SYSTEM FOR A LONG OPERATING TIME

  • Na, Young Su;Ha, Kwang Soon;Park, Rae-Joon;Park, Jong-Hwa;Cho, Song-Won
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.797-802
    • /
    • 2014
  • This study investigated the thermal hydraulic issues in the Containment Filtered Venting System (CFVS) for a long operating time using the MELCOR computer code. The modeling of the CFVS, including the models for pool scrubbing and the filter, was added to the input file for the OPR-1000, and a Station Blackout (SBO) was chosen as an accident scenario. Although depressurization in the containment building as a primary objective of the CFVS was successful, the decontamination feature by scrubbing and filtering in the CFVS for a long operating time could fail by the continuous evaporation of the scrubbing solution. After the operation of the CFVS, the atmosphere temperature in the CFVS became slightly above the water saturation temperature owing to the release of an amount of steam with high temperature from the containment building to the scrubbing solution. Reduced pipe diameters at the inlet and outlet of the CFVS vessel mitigated the evaporation of scrubbing water by controlling the amount of high-temperature steam and the water saturation temperature.

스크린 메쉬형 가변전열 히트파이프에서 NCG양에 따른 작동특성 변화 (Influence of NCG Charging Mass on the Thermal Characteristics of Variable Conductance Heat Pipe with Screen Mesh Wick)

  • 서정세;박영식;강창호;정경택;박기호;이기우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1400-1405
    • /
    • 2004
  • Experimental study is performed to investigate the effect of heat load and operating temperature on the thermal performance of a heat pipe with screen mesh wick. The heat pipe was designed in 200 screen meshes, 500mm length and 12.7mm O.D tube of copper, water as working fluid(4.8g) and nitrogen as non-condensible gas(NCG). The heat pipe used in this study has evaporator, condenser and adiabatic section, respectively. Experimental data of axial wall temperature distribution is presented for heat transport capacity, the temperature of cooling water of condenser, inclination angle, and operating temperature. For the results from this study, it is found that, for the same charging mass of working fluid, the initial operating temperature and the overall wall temperatures of heat pipe are higher for NCG charging mass of $5.0{\times}10^{-6}kg$ and $3.4{\times}10^{-6}kg$, than that of $1.0{\times}10^{-6}kg$.

  • PDF

세라믹 열교환기의 성능평가를 위한 실험적 연구 (An Experimental Study for Performance Evaluation of a Ceramic Heat Exchanger)

  • 최현수;신동훈
    • 한국연소학회지
    • /
    • 제16권1호
    • /
    • pp.46-51
    • /
    • 2011
  • Exhaust gas of an industrial furnace used at such as metallurgy or ceramic manufacturing usually contains thermal energy with high temperature which can be recycled by heat exchanger. However, when the temperature of the exhaust gas is high such as more than $1,000^{\circ}C$, ordinary metallic heat exchanger cannot fully recover the heat due to the limitation of operating temperature depending on the material property. In the present study, a compact ceramic heat exchanger of cross flow type is introduced and evaluated by heat exchange rate and operating temperature. The ceramic heat exchanger can endure the gas temperature more than $1,300^{\circ}C$, and its volumetric heat exchanging rate exceeds 1 MW/$m^3$. The experimental data is also compared with the previous numerical result which shows reasonable agreement. Meanwhile, the gas leakage rate is measured to be about 3~4%, and heat loss to environmental air is about 23~26% of the fuel energy.

교류 임피던스 측정법을 이용한 고분자 전해질 연료전지의 성능특성 분석 (Performance Analysis of Polymer Electrolyte Membrane Fuel Cell by AC Impedance Measurement)

  • 서상헌;이창식
    • 한국수소및신에너지학회논문집
    • /
    • 제20권4호
    • /
    • pp.283-290
    • /
    • 2009
  • This study focuses on the performance characteristics of polymer electrolyte membrane fuel cell (PEMFC) using the AC impedance technique. The experiment was carried out to investigate the optimal operating conditions of PEMFC such as cell temperature, flow rate, humidified temperature and back-pressure. The fuel cell performance was analyzed by DC electronic-loader with constant voltage mode and expressed by voltage-current density. Additionally, AC impedance was measured to analysis of ohmic and activation loss and expressed by Nyquist plot. The results showed that the cell performance increased with increase of cell temperature, air flow rate, humidified temperature and backpressure. Also, the activation loss decreased as the increase of cell temperature, air flow rate, humidified temperature and backpressure.

다공질 물질의 냉각현상 연구를 통한 코크스냉각공정의 모델링 (Modeling for a Coke Dry Quenching Process Using a Theory of a Porous Material)

  • 김주한;이용주;김기석
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.697-701
    • /
    • 2012
  • Numerical modeling for a coke dry quenching process was developed and evaluated. The cokes had similar characteristics to a porous material, therefore, its quenching analysis was simplified as a cooling process of porous blocks. A uniform inlet temperature and constant properties of materials in the oven were also assumed. With given operating conditions, temperature profiles in the cokes were calculated and compared to the actual values. The calculated temperature gradient was high at the upper part of the coke flow and the cooling rate decreased as cokes came down to the exit port. The exit port temperature of cokes was similar to the measured value, however, temperature-dependent material properties and operating conditions must be considered to predict the temperature precisely. The calculated results could be applied to design a coke oven to produce high quality cokes.

봄철 태양열 하이브리드 시스템의 부하조건 변화에 따른 운전특성 연구 (Study on the Operating Characteristics with Load Condition in Hybrid Solar Heating System during Spring Season)

  • 표종현;김원석;조홍현;류남진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1418-1423
    • /
    • 2009
  • This study describes experimental study on the performance characteristics with load condition in hybrid solar heating system during spring season. The room temperatures, the hot water conditions and the lower part temperatures of heat storage tank were changed to analyze the system performances. As a results, the hot water was significantly affected by the ambient temperature. The indoor setting temperature affected the solar fraction. When the low part temperature of the storage tank increased, the temperature of the hot water rose and the temperature of the hot water in morning was affected by the ambient temperature.

  • PDF