온도 감지 센서가 구비된 도어 자동 개폐기 구동용 액추에이터 시스템의 동작 특성 해석 (Operating Characteristics of Actuator System for Automatic Door Operated by Temperature Detecting Sensor)

  • 김양호;손웅태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.815-817
    • /
    • 2004
  • This paper deals with the characteristics analysis and experiments of operating actuator for automatic door operated by fire detecting sensor. The dynamic characteristics of operating actuator system are analyzed on the structure of the operating actuator model. Simulation and experimental result have been performed for the verification of the proposed system and dynamic characteristics applied to a actuator by electromechanical energy conversion theory. The experimental result have been compared with proposed theoretical predictions. In this experimental result represented the temperature T1 and T2 which remarks T1 is a circumstance of operating actuator system, and T2 is a fire detecting sensor part.

  • PDF

노후화된 누전차단기의 과전류 동작 특성에 관한 연구 (A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent)

  • 박예진;강신동;김재호
    • 한국안전학회지
    • /
    • 제38권5호
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.

열중량 반응기를 이용한 제지슬러지의 연소 특성 (Combustion Characteristic of Paper Sludge Using TGA Reactor)

  • 육찬남;김정수;한광수
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.48-58
    • /
    • 2003
  • To obtain the preliminary design data for combustion of paper sludges, decomposition characteristics and combustion kinetics of paper sludges reactor have been determined in a TGA reactor. Also, the combustion characteristics of paper sludges have been determined in a fluidized bed reactor. The data obtained from the TGA reactor indicate that dewatering of paper sludge is terminated at temperature below 130${\circ}$C. With heating rate of 20${\circ}$C/min, combustion is terminated at temperature below 340${\circ}$C .The combustion rate is found to be first order with respect to temperature and oxygen concentration. Activation energies for paper wastes are found to be 570, 700, 2600, 4600 Kcal/mole, respectively. The calcination conversions were investigated with the operating temperature and residence time. In this investigation, it was found that calcination conversion was affected by the operating temperature and residence time. The optimum conditions of operating temperature and mean residence time were 850${\circ}$C and 6 minutes of respectively.

On-off 제어계통을 갖는 냉동기의 최적제어에 관한 연구 (A study on the optimum control of refrigerator with on-off control system)

  • 하주식;김원녕;김경근;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.317-327
    • /
    • 1985
  • In the case of temperature control of air conditioning and refrigerating system, it is possible to operate the system continuously by controlling the cooling capacity of refrigerating machines. But on-off control system has been adopted for refrigerating system which has more large capacity than that required to remove the generated heat. In this on-off control system, it can be considered that there exists some optimum condition for the refrigerating capacity, operating cycle, running hour, and the temperature difference between thermostat setting value and real one. In this paper, an equation was derived to express the temperature variation of the refrigerated object (Nybrine) and later two evaluating functions were derived. One is for the temperature difference and another is for operating cycle and running hour. The weighted sum of these two functions is defined as the criterion function for the evaluation of the control performance of the system, and then the optimum running condition is investigated in the sense of minimizing the criterion function. Experiments showed that the heat balance equation derived for the temperature variation and the estimation of the time constant of the refrigerated system are appropriate. By conclusion, if a proper weighting factor D is selected, the optimum conditions exist for the refrigerating capacity, running hour, and operating cycle in the on-off temperature control of the refrigerating system.

  • PDF

생체 건조용 대형 저온진공건조기의 열적 특성에 관한 연구 (A Study on the Thermal Characteristics of the Large Low Temperature Vacuum Dryer for Biological Drying)

  • 김경근;성부용;정한식;최순열;문수범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권4호
    • /
    • pp.427-434
    • /
    • 2000
  • In tradition, there have been two kinds of drying methods, which are sun drying and artificial drying. The sun drying method which has been adopted traditionally has been replaced by the hot-air drying method which is one of the most general methods of artificial drying, with its simple drying system, low initial cost of drying plant, and easy operating method. But the hot-air drying method has some defects; (1) much energy loss happens due to the discharge of hot air during the drying process, (2) control of drying rate is not easy on account of changing relative humidity of inlet air for uniform hot air temperature, (3) high temperature of foods in drying process brings about the production of low-grade drying products. Vacuum drying takes advantage of energy saving and mass production because it reduces the drying time by increasing the drying rate under low temperature condition. The aim of this paper is to develop the low temperature vacum dryer, with low initial investments and operating costs, easy operating method and trouble-free operation.

  • PDF

온도측정 기반의 최적전압을 이용한 PV 시스템의 TMOV MPPT 제어 (TMOV MPPT Control of PV System with Temperature Measurement based Optimal Voltage)

  • 고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제26권11호
    • /
    • pp.30-39
    • /
    • 2012
  • The characteristics of I-V and P-V of solar cell nonlinearly changes according to irradiation, temperature and load. Therefore, to use efficiently PV system, operating point must be always operating at maximum power point. Also, PV system is semiconductor, so it generates loss by temperature. But because of conventional MPPT methods are not considering temperature, it has problem which decrease efficiency. This paper proposes temperature measurement based optimal voltage(TMOV) MPPT algorithm using temperature measurement based optimal voltage. It analyzes characteristics of solar cell according to irradiation and temperature and conventional MPPT methods. The TMOV control algorithm proposed in this paper is compared and analyzed conventional MPPT methods. The validity of this paper proves using this result.

온도상승에 따른 배선용 차단기의 동작특성에 관한 연구 (A Study on the Operating Characteristics of Molded Case Circuit Breakers according to Temperature Rise)

  • 정다운;김재호
    • 한국안전학회지
    • /
    • 제30권5호
    • /
    • pp.8-13
    • /
    • 2015
  • Molded Case Circuit Breakers (MCCBs) are typically used to provide over current protection for electrical safety caused by short circuit faults and overloads in indoor low voltage power systems. The MCCB automatically connects and disconnects loads from the electrical source when the current reaches a value and duration that will cause an excessive. However, the MCCB sometimes is not interrupted due to a malfunction, nuisance tripping, or in a fire. Ensuring electrical safety is very important in a indoor low voltage power system. This paper presents the operating characteristics of MCCBs according to a temperature rise from room temperature to 160 degrees Celsius delivered by a radiant panel heater. The ABS 54c(rated current: 30A) of the hydraulic magnetic trip type was used in the experiments. The signals of temperature, voltage, and current were measured using the high accuracy Signal Conditioning Extensions for Instrumentation (SCXI) measurement system with the LabVIEW program manufactured by National Instruments. The operating characteristics were measured as functions of current amplitude and ramp-up rate. The MCCB tripping time decreased as a result of increasing current amplitude and ramp-up rate under a temperature rise condition, because the temperature and level of the current are directly proportional to the tripping time. Additionally, an instantaneous operation was observed after 8 times of the rated current, and the MCCB began to melt a surface temperature of around 300 degrees Celsius of. The experimental results coincided well with the operating curve.

CREEP-FATIGUE CRACK GROWTH AND CREEP RUPTURE BEHAVIOR IN TYPE 316 STAINLESS STEELS- EFFECT OF HOLD TIME AND AGING TREATMENT

  • Mi, J.W.;Won, S.J.;Kim, M.J.;Lim, B.S.
    • International Journal of Automotive Technology
    • /
    • 제1권2호
    • /
    • pp.71-77
    • /
    • 2000
  • High temperature materials in service are subjected to mechanical damage due to operating load and metallurgical damage due to operating temperature. Therefore, when designing or assessing life of high temperature components, both factors must be considered. In this paper, the effect of tensile hold time on high temperature fatigue crack growth and long term prior thermal aging heat treatment on creep rupture behavior were investigated using STS 316L and STS 316 austenitic stainless steels, which are widely used for high temperature components like in automotive exhaust and piping systems. In high temperature fatigue crack growth tests using STS 316L, as tensile hold time increased, crack growth rate decreased in relatively short tensile hold time region. In long term aged specimens, cavity type microcracks have been observed at the interface of grain boundary and coarsened carbide.

  • PDF

실물 실험을 통한 태양광 모듈의 표면온도와 태양광 발전량과의 관계에 대한 연구 (A Study on the Relationship Between Photovoltaic Module Surface Temperature and Photovoltaic Power Using Real Experiment)

  • 조성우
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권3호
    • /
    • pp.8-14
    • /
    • 2018
  • PV module power is calculated on PV module surface temperature adjustment by irradiation on the summer and autumn in NOCT(Nominal Operating Cell Temperature) conditions. The summer and autumn periods were selected because of large variation in outdoor air temperature and irradiation. This study was performed to understand relationship between PV module surface temperature and photovoltaic power using field measurement. As a results, it was determined that the amount of irradiation was proportional to the amount of photovoltaic power in the field measurement. However, it was also identified that the PV power generation decreased by increased PV module surface temperatures due to irradiation.

대체 프레온계 냉매를 이용하는 이원 냉동시스템의 성능예측 (Prediction on Performance of Cascade Refrigeration System using Alternative Freon Refrigerants)

  • 노건상
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.73-79
    • /
    • 2011
  • In this paper, cycle performance analysis of cascade refrigeration system using alternative FREON refrigerants are presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include subcooled and superheated degree, and evaporating and condensing temperature, temperature difference of cascade heat exchanger in cascade refrigeration system. The COP of cascade refrigeration system increases with the increasing subcooled degree, but there is no significant changes with the increasing superheated degree. The COP of cascade refrigeration system depends on evaporating and condensing temperatures of cascade heat exchanger. Therefore, subcooled degree, evaporating and condensing temperature of cascade heat exchanger using alternative FREON refrigerants have an effect on the COP of this system. In this paper, COP of cascade refrigeration system using R23 for low temperature system and R507A for high temperature system is higher 8 ~ 29 % than using R13 for low temperature system and R22 for high temperature system.