• Title/Summary/Keyword: operating point

Search Result 1,758, Processing Time 0.039 seconds

A New Linearized Equation for Modelling a Servovalve in Hydraulic Control Systems (유압 제어계에서 서보밸브 모델링을 위한 새로운 선형화 방정식의 제안)

  • Kim, Tae-Hyung;Lee, Ill-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.5
    • /
    • pp.789-797
    • /
    • 2003
  • In the procedure of the hydraulic control system design, a linearized approximate equation described by the first order terms of Taylor series has been widely used. Such a linearized equation is effective just near the operating point, However, pressure and flowrate in actual hydraulic systems are usually not confined near an operating point. This study suggests a new linearized flow equation for a servovalve as a modified form of the conventional linearized flow equation. Subsequently, a procedure to determine effective operating point for the new linearized equation is proposed. From the evaluations of time responses and frequency responses obtained from simulations for a hydraulic control system, the effectiveness of the new linearized equation and the procedure to determine effective operating point is confirmed.

Analysis of Small Signal Stability Using Resonance Conditions (공진조건을 이용한 미소신호 안정도 해석)

  • Cho, Sung-Jin;Jang, Gil-Soo;Yoon, Tae-Woong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.11
    • /
    • pp.535-543
    • /
    • 2002
  • Modern power grids are becoming more and more stressed with the load demands increasing continually. Therefore large stressed power systems exhibit complicated dynamic behavior when subjected to small disturbance. Especially, it is needed to analyze special conditions which make small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability structure varied according to operating conditions. This paper shows that the relation between small signal stability and operating conditions can be identified well using node-focus point and 1:1 resonance point. Also, the weak point which limits operating range is found by the analysis of resonance condition, and it is shown that reactive power compensation may solve the problem in the weak points. The proposed method is applied to test systems, and the results illustrate its capabilities.

An Intelligent System to Prevent Voltage Collapse for A Power system (전력계통의 전압 붕괴 방지를 위한 인텔리젼트 시스템)

  • Kim, Jae-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.10
    • /
    • pp.472-479
    • /
    • 2001
  • In order to prevent voltage collapse. this paper introduces the idea of the intelligent system and operating polices for a power system, then presents the results of voltage stability studies for that power system. The intelligent system includes a dedicated computer doing calculation and evaluation jobs and several intelligent relays serving as last guards to carry out the pre-set remedies. In the intelligent system, P-V curves are used to determine the operating margin from the current operating point to the maximum operating point, or the nose point. This paper suggests an operating guide for voltage stability of a power system. The effectiveness of location ad amount of load shedding for the different power load models are studied.

  • PDF

Power Gain during Partial Shade Condition with Partial Shade Loss Compensation in Photovoltaic System

  • Yoon, Byung-Keun;Yun, Chul;Cho, Nae-Soo;Choi, Sang-Back;Jin, Yong-Su;Kwon, Woo-Hyen
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.769-780
    • /
    • 2018
  • This paper presents an analysis of the power gain under partial shading conditions (PSC) when the partial shade loss is being compensated in photovoltaic(PV) system. To analyze the power gain, our study divides the mismatch loss into partial shade loss and operating point loss. Partial shade loss is defined as the power difference between a normal string and a partially shaded string at the maximum power point (MPP). Operating point loss is defined as the power loss due to the operating point shift while following the MPP of the PV array. Partial shading in a PV system affects the maximum power point tracking (MPPT) control by creating multiple MPPs, which causes mismatch losses. Several MPPT algorithms have been suggested to solve the multiple MPP problems. Among these, mismatch compensation algorithms require additional power to compensate for the mismatch loss; however, these algorithms do not consider the gain or loss between the input power required for compensation and the increased output power obtained after compensation. This paper analyzes the power gain resulting from the partial shade loss compensation under PSC, using the V-P curve of the PV system, and verifies that power gain existence by simulation and experiment.

MAXIMUM POWER POINT TRACKING CONTROL OF PHOTOVOLTAIC ARRAY USING FUZZY NEURAL NETWORK

  • Tomonobu Senjyu;Yasuyuki Arashiro;Katsumi Uezato;Hee, Han-Kyung
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.987-992
    • /
    • 1998
  • Solar cell has an optimum operating point to extract maximum power. To control operating point of the solar cell, a fuzzy controller has already been proposed by our research group. However, several parameters are determined by trial and error. To overcome this problem, this paper adopts Fuzzy Neural Network (FNN) for maximum power point tracking control for photovoltaic array. The FNN can be trained to perfect fuzzy rules and to find an optimum membership functions on-line.

  • PDF

A Study on Optimal Current Control Method for Small BLDC Motor Drive (소형 BLDCM 드라이브의 최적 전류제어에 관한 연구)

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.108-115
    • /
    • 2015
  • This paper proposed a optimal current control method to improve efficiency of BLDC motors. The aim of the proposed method is to use the maximum torque operating method by increasing the effective voltage at the maximum torque point unlike existing SPM operating method. The proposed method is based on existing IPM maximum torque operating method grafting onto a square wave operating of SPM motors. As the method of increasing the effective output voltage from inverter using the maximum torque point, the proposed method is to improve efficiency of BLDC motors using the same amount of the existing current effectively. For this method, the maximum torque point is carried out by FEA and analysis of magnetic flux vector. In this paper, the prototype of general-purpose BLDC drive is manufactured and the performance characteristic and validity are verified.

MPPT Control of Photovoltaic using Variable IC Method (가변 IC 방법을 이용한 태양광 발전의 MPPT 제어)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.27-34
    • /
    • 2012
  • This paper proposes variable incremental conductance(IC) algorithm for maximum power point tracking(MPPT) control of photovoltaic. The conventional perturbation & observation(PO) and IC MPPT control algorithm generally uses fixed step size. A small step size reduces a tracking error in the steady state but slows a tracking speed in the transient state. Also, a large step size is fast a tracking speed but increases a tracking error. Therefore, this paper proposes variable IC MPPT algorithm that adjust automatically step size according to operating conditions. To improve a tracking speed and accuracy, when operating point is far from the maximum power point(MPP), the step size uses maximum value and when a operating point is near from the MPP, the step size uses variable step size that adjust according to slope of P-V curve. The validity of MPPT algorithm proposed in this paper prove through compare with conventional PO and IC MPPT algorithm.

Diagnosis Method of PV Module Mismatch using Voltage and Current Waveforms (태양광 모듈의 전압 및 전류 파형을 이용한 부정합 진단 기법)

  • Ahn, Hee-Wook;Park, Gi-Yob
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.17-22
    • /
    • 2011
  • Techniques for mismatch loss minimization to increase the PV system efficiency are under development recently. In this paper, a method to make diagnosis of PV module mismatch is presented, which uses a concept of operating point factor. The method is based on the fact that the ratio of the incremental conductance of a PV module to instantaneous conductance is 1 when the module is operating at its maximum power point. The variations of module voltage and current are taking place by the maximum power point tracker in the power conditioning units of PV system. The effectiveness of the method is verified through an application to a real PV system.

Design of a ControLler for Level Control System Using Adaptive Control (적응제어기법을 이용한 레벨제어시스템의 제어기 설계)

  • 소명옥;정재학;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.5
    • /
    • pp.54-62
    • /
    • 1993
  • Generally, the main difficulty in the composition of tank-level control system may be in the point that plant parameters are severely varied according to the change of operating point. In order to cope with this difficulty, in this paper, an adaptive control is employed using model-following technique based on the optimal control law. Through the simulations and experiments the following results were observed. 1) The steady-state error was not found under the parameter variations caused by the change of operating point. 2) In spite of the change of operating point, the corresponding gains which were stored in the computer were found to be automatically updated so that the controller could have the adaptive ability. And also, the control specifications in view of transient response were found to be satisfied.

  • PDF

A Study on the Evaluation Method of the Operation Stability of a Torque Converter Mounted on Industrial Vehicle (산업차량용 토크컨버터의 작동 안정성 평가 방법에 대한 연구)

  • Kim, Beom-Soo;Lim, Won-Sik;Cha, Suk-Won
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.91-98
    • /
    • 2007
  • This paper presents the induced mathematical modeling equations for evaluating the operation stability with automatic transmission of heavy duty vehicle. This theoretical approach indicates that linearized governing equations of system can be converted into eigen-value problems. if the eigen-value has positive number, we can predict the engine operating point locates an unstable operating region. To be a stable state, the unstable operating point diverges toward a stable point which is able to maintain uniform velocity. Based on the previous theoretical analysis, we carry out dynamic simulation to show the behavior of engine operating point and torque converter in transient state. As a result of the dynamic simulation, the suggested theoretical method is found to be reasonable for evaluating the operation stability of a torque converter. In addition, the numerical results explain the engine stops and fluctuating phenomenon in reality.