• 제목/요약/키워드: operating performance

검색결과 6,517건 처리시간 0.033초

Improvement in Efficiency and Operating Range of Centrifugal Blower Stage for Sewage Aeration Blower

  • Hiradate, Kiyotaka;Kanno, Toshio;Nishida, Hideo;Shinkawa, Yasushi;Joukou, Satoshi
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.379-385
    • /
    • 2010
  • We developed a high-efficiency, wide-operating-range centrifugal blower stage to meet the demand for reduced total energy-consumption in sewage treatment plants. We improved the efficiency of the two-dimensional impeller using a shape optimization tool and one-dimensional performance prediction tool. A limit of the throat deceleration ratio was set to maintain the stall-margin of the impeller. The low solidity vaned diffuser and return channel were designed using a sensitivity analysis with orthogonal arrays and three-dimensional steady flow simulations. The low solidity diffuser was designed in order to improve the performance in the low-flow-rate region. The return channel was designed so that the total pressure loss in the return channel was minimized. Model tests of both the conventional and optimized blower stages were carried out, and the efficiency and operating range of both stages were compared. The optimized blower stage improved in stage efficiency by 3% and in operating range by 5% compared with the conventional blower stage.

홴싱크의 입구 봉쇄에 따른 유동 및 냉각 특성에 관한 연구 (A Study on the Flow and Cooling Characteristics with the Inlet Blockage of a Fan-Sink)

  • 이경용;최영석;윤재호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.83-88
    • /
    • 2004
  • In this study, the flow and thermal performance of the heat sink and fan-sink were experimentally studied to predict the operating condition of the fan-sink. The experiments of the flow and thermal resistance of the heat sink with various inlet blockage, which were occurred by the shapes of the axial fans, were conducted for the proof of the effects of the inlet blockages. The greater the inlet blockage of the heat sink, the higher the pressure drop and lower the thermal resistance of the heat sink will be. The operating point of the fan-sink was predicted by the pressure drop curve with the inlet blockage, which was corresponded to the selected fan and the fan performance curve, and verified by the performance test of the fan-sink. The predicted operating point of the fan-sink had good agreement with the result of the performance test of the fan-sink within $0.7\%$ of the volume flow rates. Measured thermal resistance of the fan-sink was equivalent to that of the heat sink with the same inlet blockage of the fan-sink. It was shown that the heat transfer characteristics of the heat sink were influenced by the flow interaction between the selected fan and the heat sink. To improve the thermal resistance of the heat sink, it is necessary to consider appropriate flow patterns of the fan outlet entering into the heat sink.

  • PDF

황화수소 피독이 고분자전해질 막 연료전지의 성능에 미치는 영향 (The performance of PEMFC after hydrogen sulfide poisoning under various operating conditions)

  • 이수;진석환;김상명
    • 한국응용과학기술학회지
    • /
    • 제28권1호
    • /
    • pp.57-63
    • /
    • 2011
  • Polymer electrolyte membrane fuel cell (PEMFC) performance degrades when hydrogen sulfide ($H_2S$) is present in the fuel hydrogen gas; this is referred to as $H_2S$ poisoning. This paper reveals $H_2S$ poisoning on PEMFC by measuring electrical performance of single cell FC under various operating conditions. The severity of $H_2S$ poisoning depended on $H_2S$ concentration under best operating conditions($65^{\circ}C$ of cell temperature and 100% of anode humidification). $H_2S$ adsorption occured on the surface of catalyst layer on MEA, but not on the gas diffusion layer(GDL) by analyzing SEM/EDX data. In addition, MEA poisoning by $H_2S$ was cumulative but reversible. After poisoning for less than 150 min, performance of PEMFC was recovered up to 80% by just inert nitrogen gas purging.

IMT-2000 기지국 제어기를 위한 실시간 운영체제의 성능비교 (Performance Comparison Among Realtime Operating Systems for IMT-2000 Base Station Controller)

  • 이경오;이숙진;염헌영
    • 한국통신학회논문지
    • /
    • 제24권9A호
    • /
    • pp.1314-1321
    • /
    • 1999
  • 본 논문에서는 현재 널리 사용되고 있는 상용 운영체제들 중에서는 빠른 응답 시간을 보장하고 있는 실시간 운영체제 3가지를 선정하여 이 실시간 운영체제들이 IMT-2000 기지국 제어기에 호 처리를 위해 사용될 경우 어느 정도의 성능을 보일 것인지를 실험하였다. 이를 위해서 무선 호 처리가 어떠한 방식으로 이루어지는지 분석하여 시스템 성능에 영향을 크게 미치는 기본기능요소들을 도출하였으며 분석된 내용을 중심으로 가상의 호 처리 실험 공간을 구축하고 일정 시간 운영해봄으로써 시스템의 성능에 병목현상이 되는 부분이 있는지 또 어느 운영체제의 성능이 다른 운영체제에 비해 우수한 성능을 보일 것인지를 비교 분석하였다.

  • PDF

보안 운영체제의 오버헤드 분석 (Analysis of Security Overhead in Secure Operating System)

  • 고영웅
    • 한국컴퓨터정보학회논문지
    • /
    • 제10권2호
    • /
    • pp.11-19
    • /
    • 2005
  • 본 논문에서는 보안 운영체제의 성능 평가 모델 및 시나리오에 대해서 기술하고 있으며, 보안 운영체제 성능 평가 방법을 이용하여 상용 보안 운영체제의 성능을 분석하였다. 다양한 성능 분석 툴을 이용하여 보안 운영체제의 오버헤드 결과를 자세히 분석하고 있다. 본 연구를 통해서 보안 운영체제와 일반 운영체제의 성능 비교가 가능할 것이며, 보안 운영체제에 다양한 보안 정책이 추가되었을 때와 그렇지 않은 경우 직접적인 성능의 차이를 볼 수 있게 된다. 본 연구결과는 보안 운영체제 구매자, 평가자 및 개발자들에게 가이드라인이 될 수 있으며, 보안 운영체제의 성능 평가에 대한 기초 자료로 활용 될 수 있다

  • PDF

스윙형 역지밸브 성능 평가 방법 (Performance Evaluation Method of a Swing Check Valve)

  • 김양석;이도환;김대웅;박성근;홍승열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.881-886
    • /
    • 2003
  • In spite of its simple design, structure and operating mechanism, swing check valves are one of the critical components which adversely affect the safety of the nuclear power plants if they fail to function properly. Therefore, it is important to evaluate the performance condition of the swing check valves in safety-related systems. The performance characteristics of swing check valves include opening characteristics, the minimum required flow velocity, the pressure drop at design flow, the disc stability, and the effect of the upstream disturbances. Among factors to identify the performance of a swing check valve, a method to evaluate the opening characteristics and the minimum required flow velocity, which guarantees to fully open the disc and hold the disc without motion, are presented to determine the operating region of the swing check valve, such as stable, tapping, or oscillation. Based on the determined operating region and opening characteristics, the simple methods of wear and fatigue analyses of the specific parts of the valve are also described.

  • PDF

Dr. Wastewater program의 적용을 통한 하수처리장 운전에 미치는 유입수 변동 영향평가 (Evaluation of influent changing effect on the STP performance using Dr. Wastewater)

  • 김연권;김홍석;서인석;김병균;한인선;김진상
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.647-655
    • /
    • 2008
  • Sewer Rehabilitation Project (SRP) is planed, designed and constructed to perform its intended performance as sewerage delivery systems. Recently, a subject of performance evaluation methodology development for SRP has become a great deal of concern among researchers in Korea. From the view point of Sewage Treatment Plant (STP), however, the estimation of improvement efficiency for SRP is in lack of reliability due to the fact that affections for the treatment efficiency and operating condition are not reflected on SRP design and construction. In this study, statistical methodology was used in the analysis of data, which are taken during 1,186 days ($1^{st}$ Jan. 2005 - $31^{th}$ Mar. 2008) from the influent, effluent and operating conditions of full-scale STP($25,000m^3/d$). Then the effect of SRP on the influent characteristics and operating conditions changing was compared and evaluated. Results from the statistical evaluation show that SRP causes characteristic changes in influent and exerts a significant effect especially on the performance of STP.

소형 고속정의 운항한계에 대한 연구 (A Study on Operating Limit Analysis for Small High-speed Boat)

  • 배준영
    • 해양환경안전학회지
    • /
    • 제21권6호
    • /
    • pp.784-789
    • /
    • 2015
  • 본 연구는 소형 고속정의 운항한계를 검토하기 위하여 수행되었다. 일반적으로 내항성능의 검토는 선형의 결정 단계 전에 이루어지지만 본 연구는 선박의 건조가 완료된 후에 이루어졌다. 검토 결과, 종동요, 수직 및 수평가속도, 슬래밍의 운동성능은 특정한 조우각을 제외하고는 만족하였으나 갑판침수의 경우에는 해석을 수행한 모든 조건에서 만족하지 않았다. 이것은 대상선박의 크기가 소형이기 때문에 선박의 속도나 파도와의 조우각보다는 해상상태가 설정한 내항성능 기준의 만족 여부에 더 큰 영향을 미쳤기 때문으로 보인다.

하천수 열원 이용 2단압축 열펌프의 최적성능 및 효용 운전범위에 관한 시뮬레이션 연구 (Simulation on the Optimal Performance and Effective Operating Range of a 2-Stage Compression Heat Pump Using River Water)

  • 정태훈;박차식;김용찬
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.295-303
    • /
    • 2008
  • The objectives of this study are to predict actual system performance and effective operating range of the 2-stage compression heat pump system using river water. An electronic expansion valve was applied to the simulation to analyze the effects of operating conditions on the system performance. The developed program was verified by comparing the predictions with the measured data. The results from the present model showed a good agreement with the measured data. In addition, the heat pump simulation was conducted by increasing condenser reservoir inlet temperature to investigate the benefits of the 2-stage compression over the 1-stage compression in the heating mode. The performance of the 2-stage compression cycle was better than that of the 1-stage compression when the inlet temperature of the condenser reservoir was higher than $40^{\circ}C$.

The DISNY facility for sub-cooled flow boiling performance analysis of CRUD deposited zirconium alloy cladding under pressurized water reactor condition: Design, construction, and operation

  • Ji Yong Kim;Yunju Lee;Ji Hyun Kim;In Cheol Bang
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3164-3182
    • /
    • 2023
  • The CRUD on the fuel cladding under the pressurized water reactor (PWR) operating condition causes several issues. The CRUD can act as thermal resistance and increases the local cladding temperature which accelerate the corrosion process. The hideout of boron inside the CRUD results in axial offset anomaly and reduces the plant's shutdown margin. Recently, there are efforts to revise the acceptance criteria of emergency core cooling systems (ECCS), and additionally require the modeling of the thermal resistance effect of the CRUD during the performance analysis. There is an urgent need for the evaluation of the effect of the CRUD deposition on the cladding heat transfer under PWR operating conditions, but the experimental database is very limited. The experimental facility called DISNY was designed and constructed to analyze the CRUD-related multi-physical phenomena, and the performance analysis of the constructed DISNY facility was conducted. The thermal-hydraulic and water chemistry conditions to simulate the CRUD growth under PWR operating conditions were established. The design characteristics and feasibility of the DISNY facility were validated by the MARS-KS code analysis and separate performance tests. In the current study, detailed design features, design validation results, and future utilization plans of the proposed DISNY facility are presented.