• Title/Summary/Keyword: operating module

Search Result 760, Processing Time 0.03 seconds

PIV Measurement of Flow Inside an Automotive HVAC Module with Varying Temperature Baffle (온도조절 격판 변화에 따른 차량용 HVAC 내부 유동의 PIV속도장 측정 연구)

  • Ji, Ho-Seong;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2008
  • Air flow inside an automotive HVAC module has been investigated using a high-resolution PIV technique with varying the temperature operation mode. The PIV system consists of a 2-head Nd:YAG laser (125 mJ), a high-resolution CCD camera (2K$\times$2K), optics and a synchronizer. A real automotive HVAC module was used directly under real operating condition. Some casing parts of the HVAC module were replaced with transparent windows for capturing clear flow images with laser light sheet beam illumination. Time-averaged velocity fields were obtained for two different temperature control modes. Flow characteristics of the air-conditioned air flow inside the automotive HVAC system for the two temperature baffle conditions were evaluated.

Operation Technology of PV-ESS Integrated Module for DC Micro Grid with Constant Power Tracking Algorithm (일정 전력 추종 알고리즘이 적용된 DC 마이크로 그리드용 PV-ESS 통합형 모듈의 운영 기술)

  • Ryu, Kyung;Kim, Jun-Mo;Lee, Jeong;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.6
    • /
    • pp.433-441
    • /
    • 2020
  • This study proposes a constant power tracking algorithm to compensate for the intermittent characteristics of Photovoltaic connected to a DC micro grid. A PV-ESS integrated module in which distributed ESS is additionally connected is utilized for the proposed algorithm. PV performs P&O MPPT control at all times. To supplement the intermittent characteristics of PV, the proposed constant power tracking algorithm maintains constant power by operating the distributed ESS of the PV-ESS integrated module in accordance with the output state of the PV. By performing PSIM simulation and an experiment, this study verifies the performance of the integrated module of PV-ESS for DC micro grids applying the constant power tracking algorithm.

Development of Switching Power Module with Integrated Heat Sink and with Mezzanine Structure that Minimizes Current Imbalance of Parallel SiC Power Semiconductors (SiC 전력반도체의 병렬 구동 시 전류 불균형을 최소화하는 Mezzanine 구조의 방열일체형 스위칭 모듈 개발)

  • Jeong-Ho Lee;Sung-Soo Min;Gi-Young Lee;Rae-Young Kim
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.39-47
    • /
    • 2023
  • This paper applies a structural technique with uniform parallel switch characteristics in gates and power loops to minimize the ringing and current imbalance that occurs when a general discrete package (TO-247)-based power semiconductor device is operated in parallel. Also, this propose a heat sink integrated switching module with heat sink design flexibility and high power density. The developed heat dissipation-integrated switching module verifies the symmetry of the parasitic inductance of the parallel switch through Q3D by ansys and the validity of the structural technique of the parallel switch using the LLC resonant converter experiment operating at a rated capacity of 7.5 kW.

Analysis of the Separation Using Disc Plate and Frame Type Reverse Osmosis Module (원판틀형 역삼투 모듈을 이용한 분리 특성 해석)

  • Chung, Kun-Yong;Chung, Wook;Won, Jang-Mook;Bae, Seong-Youl;Ha, Baik-Hyon
    • Membrane Journal
    • /
    • v.5 no.2
    • /
    • pp.81-88
    • /
    • 1995
  • Separation performance was measured for the disc plate and frame type reverse osmosis module using NaCl and sucrose solutions. An analysis of membrane performance was done following the equations proposed by Kimura-Sourirajan[8]. The membrane permeability was $2.17 \times 10^{-6}$(gmol/$cm^2$-sec-bar) and independent of operating pressure. The effect of concentration polarization for sucrose solution was higher than that of NaCl. Permeation flux for sucrose solution above 40 bar was decreased as operating pressure was increased. Solute rejection for NaCl solution was decreased, but that of sucrose was increased as operating pressure was increased.

  • PDF

Design and Implementation of Data Logger for Elevator Remote Monitoring (승강기 원격 관제를 위한 데이터 수집기 설계 및 구현)

  • Gu, Bongen
    • Journal of Platform Technology
    • /
    • v.8 no.4
    • /
    • pp.3-10
    • /
    • 2020
  • An elevator maintenance company maintains many types of elevators from many manufactures. So, they want to use manufacture- or type-independent elevator remote monitoring system. To do this, data logger, that receives elevator operating state data from sensor module installed in elevator and transfers the data to database, is required. In this paper, we design and implement data logger of elevator remote monitoring system for providing elevator operation state information to elevator maintenance company. Data logger receives elevator operation state data from sensor module installed in elevator, decodes data, and converts to API data for transferring elevator operation state data to server. In this paper, we describe the implementation of data logger using python, and show that our implementation of data logger is successfully operating in a real elevator operating environment via log message displayed at screen.

  • PDF

Evaluation of the Flux According to Membrane Distillation Module Structure and Operating Conditions Using PVDF Hollow Fiber Membrane (PVDF 중공사 분리막을 이용한 MD 모듈 구조 및 운전 조건에 따른 플럭스 영향 평가)

  • Min, Ji Hee;Lee, Seul ki;Gil, Nam Seok;Park, Min Soo;Kim, Jin Ho
    • Membrane Journal
    • /
    • v.28 no.2
    • /
    • pp.83-89
    • /
    • 2018
  • Hydrophobic porous PVDF hollow fiber membranes for Membrane Distillation (MD) were fabricated by a combination of thermally induced phase separation (TIPS) and stretching. The purpose of this study is to investigate the shape and operating conditions of the module and the effect of piping size on parallel connection. In the optimization experiment of the vacuum membrane distillation module, the flux decreased as the packing density and length of the membrane in the module increased. When the module was connected vertically, it was confirmed that the nearest to the inlet of the vacuum port was the highest flux. In selecting the size of the header pipe of the module, it was confirmed that the maximum flux is shown when the inner diameter area of the hollow fiber membrane and the inner diameter area of the header pipe are the same. Also, it is necessary to find the optimal linear velocity because the higher the linear velocity in the module, the higher the flux, but the pressure acting on the module also increases proportionally.

Parts Stresss Analysis for Reliability Prediction of Control Module in Plant (부품부하분석을 이용한 발전소 제어모듈의 신뢰도 예측)

  • 김대웅;강희정
    • Journal of Energy Engineering
    • /
    • v.4 no.3
    • /
    • pp.338-343
    • /
    • 1995
  • The objective of this study is to predict the reliability of the electronic control module at ROD control system in nuclear power plant. Maintaining of the reliability is important issue in the complext system like nuclear plower plant, military equipment, satelite system, etc., because the failure of reliability brings etravagant economic loss and deteriorates public acceptance. In addition to the prediction of reliability, the fators affect the reliability including operating condition, environment, temperature and quality factors were analyzed and simulated. The result shows that the quality factors are more critical for the higher reliability than other two factors.

  • PDF

The Novel Control Circuit Design and Implementation for an Power Amplifier Module (AIS용 전력 증폭기 모듈의 새로운 출력 제아 회로 설계 및 제작)

  • Han, Jae-Ryong
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.669-679
    • /
    • 2003
  • Through AIS(Automatic Identification System), ITU-R suggested the navigational data communication between ships and between ships and shore stations for the better safety of navigation, and it requires two different the transmitting output power level depending on its operating mode. According to ITU's recommendation, these levels should reach within 20% of its final value in 1ms. In this paper, an adequate feedback control circuit for power amplifier module is designed and implemented.

  • PDF

Optimal Reactive Power Planning Using Decomposition Method (분할법을 이용한 최적 무효전력 설비계획)

  • 김정부;정동원;김건중;박영문
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.585-592
    • /
    • 1989
  • This paper presents an efficient algorithm for the reactive planning of transmission network under normal operating conditions. The optimal operation of a power system is a prerequisite to obtain the optimal investment planning. The operation problem is decomposed into a P-optimization module and a Q-optimization module, but both modules use the same objective function of generation cost. In the investment problem, a new variable decomposition technique is adopted which can operate the operation and the investment variables. The optimization problem is solved by using the gradient projection method (GPM).

  • PDF

A Study of Authentication Scheme and Operating Method of Multi Master Keys for Cryptosystem using Tamper Resistant Module (Tamper Resistant Module을 이용한 암호시스템에서의 인증방식과 다중마스터 키의 운용에 관한 연구)

  • 조주연;이필중
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 1992.11a
    • /
    • pp.81-98
    • /
    • 1992
  • 본 논문에서는 TRM을 이용한 사용자의 ID를 기초로 하는 암호시스템을 구현하고 안전성 유지를 위해 반드시 필요한 TRM과 사용자사이의 쌍방인증방식을 설명하였다. 그리고 이의 개선된 방식으로서 키 생성키인 마스터키를 다중화 하여 TRM내에 국소 분배함으로써 TRM내의마스터 키를 시스템 상에서 보호하는 방안과 TRM Identity(TID)를 이용한 디지탈 서명방식을 제안하였다. 제안된 방식은 암/복호화의 속도가 빠른 관용 암호알고리듬을 사용하면서도 디지탈 서명을 비롯한 공개키 암호알고리듬이 가지고 있는 장점들을 모두 구현하고 있다.

  • PDF