• Title/Summary/Keyword: operating margin

Search Result 299, Processing Time 0.03 seconds

Rotordynamic Analysis and Experimental Investigation of the Turbine-Generator System Connected with Magnetic Coupling (마그네틱 커플링으로 연결된 터빈-발전기 시스템의 로터다이나믹 해석 및 실험적 고찰)

  • Kim, Byung Ok;Park, Moo Ryong;Choi, Bum Seok
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.3
    • /
    • pp.32-38
    • /
    • 2013
  • This paper deals with the study on the rotordynamic and experimental analysis of turbine-generator system connected with a magnetic coupling. Although magnetic coupling has been used to torque transmission of chemical processing pump rotating at under 3,600rpm, magnetic coupling in this study is applied to high-speed turbine-generator system using a working fluid that is refrigerant such as ammonia or R-124a. Results of rotordynamic design analysis are as follows. The first, shaft diameter nearest to outer hub of magnetic coupling has a big effect on the $1^{st}$ critical speed of generator rotor. The second, if the $1^{st}$ critical speeds of turbine rotor and generator rotor have enough to separation margin in comparison to rated speed, the $1^{st}$ critical speed of turbine-magnetic coupling-generator rotor train has enough to separation margin regardless of connection stiffness of magnetic coupling. The analytical FE model is guaranteed by impact test on the prototype and condition monitoring such as measurements of vibration and bearing temperature is also performed.

A Study on the Display Discharge Characteristics of PDP for the HDTV (HDIV를 위한 PDP의 표시방전특성에 관한 연구)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.39-46
    • /
    • 2005
  • This research concerns the ADS drive method of 3 electrodes AC PDP and is determined the minimum pulse width of the address and the sustain, which the steady sustain discharge without decreasing luminance can be obtained. From the experimental result, if the address pulse width became $1.5[{\mu}s]$ or more a effective address discharge with the operating margin of 35[V] was possible. And if the sustain pulses width became $2[{\mu}s]$ or more, a steady sustain discharge with the operation margin of 25[V] was possible. When this condition is applied to Full-HDTV class PDP with the in lines of horizontal scanning lines, 8 sub-fields and total 1420 sustain pulses can be used.

A Security-oriented Operation Scheme of FACTS Devices to Cope with A Single Line-faulted Contingency (단일 선로고장시 정적 안전도 향상을 위한 유연송전기기 운전 방안)

  • Lim, Jung-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.149-155
    • /
    • 2004
  • This paper presents how to find proper operating points of FACTS devices to enhance the steady-state security level considering line contigency analysis. Three generic types of FACTS devices such as series controllers, shunt controllers, and series-shunt controllers are introduced and applied to moximize a security margin and to minimize security indices. Security indices related to line flows and bus voltages are utilized and minimized iteratively in this paper. Contingency analysis is performed to detect the most severe single line fault. In various load conditions, FACTS devices are tested to establish appropriate preventive or corrective action without generation re-dispatching or load shedding. The FACTS operation scheme is verified on the IEEE 57-bus system in a line-faulted contingency.

A Study on the Accounting Transparency Financial Characteristics between ERP Systems Implementation and Non Implementation Companies (ERP시스템 도입기업과 미도입기업의 회계투명성 관련 재무적 특성)

  • Choi, Hyun-Dol;Lee, Jang-Hyung
    • The Journal of Information Systems
    • /
    • v.14 no.1
    • /
    • pp.107-124
    • /
    • 2005
  • ERP systems are comprehensive sorfware packages that seek to integrate the complete range of lbusiness processes and functions in order to present a heuristic perspectives of a firm from a single information and information technlogy architecture. The ERP systems have delicate internal controls with built-in devices. It is known that the delicate internal controls help to enhance the accounting transparency. We empirically investigate the relationship between the ERP systems inplementations and an accounting transparency. In order to measure the accounting transparency differences, we compare the ERP systems implementation firms with firms which did not implement the ERP systems by 6 financial ratios (accruals, net profit margin, operation cash folo to sales, total debt to equity, accounts receivable changes, assets quality). Data are collecte from 135 firms implemented the ERP systems and 135 firms non-implemented the systems (the firms listed in the Korea Stock Exchange). We analyze financial statements from 270 firms for the period 2001-2003 to ezamine the 6 financial ratios differences. The results of 810 firms analyses over the 3-year period indicate that the ERP systems implementation firms show the statistically significant differences in the accrual ratio, the net profit margin ratio, operating cash flow to sales ratio, and total debt to equity ratio from the ERP systems non-implementation firms. But there is statistically no differences between the two groups for accounts receivable changes to sales ratio and assets quality.

  • PDF

Managerial Effectiveness of Integrated Delivery System in Japan (의료서비스 복합화의 경영효과 분석 : 일본의 사례)

  • Jeong, Seung-Won;Inoue, Yusuke;Seo, Young-Joon;Kim, Yun-Hee
    • Korea Journal of Hospital Management
    • /
    • v.14 no.2
    • /
    • pp.60-74
    • /
    • 2009
  • This study purports to verify managerial effectiveness of the integrated delivery system(IDS) of Japanese health care institutions through comparing the managerial performance between hospital groups providing with both acute and nursing care and those with acute care only. Data on the managerial performance of 697 hospitals providing with nursing care together and 819 hospitals providing with acute care only were collected from Japanese Central Social Insurance Medical Councils 2001, 2003, 2005, and were analyzed using mean comparison test(t-test) between the two groups. The results revealed that there were significant differences between the two groups in such indicators as ratio of material cost, labor cost, depreciation rate, total margin, operating margin, average number of outpatient per day, average revenue of an inpatient per day, total amount of labor cost, gross revenue per employee, and labor productivity. However, we could not find out any consistent evidence which support the effect of integrated delivery system on the hospital managerial performance. Further discussion was made on the limitation of the study and future research agenda relevant to the topic.

  • PDF

High Performance AC-PDP Sustain Driver with Low switching Loss (낮은 스위칭 손실을 가지는 고성능 AC-PDP 구동 회로에 관한 연구)

  • Kang, Feel-Soon;Park, Sung-Jun;Park, Han-Woong;Kim, Cheul-U
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.50-56
    • /
    • 2002
  • When the plasma panel is used as a display, frequent discharging are made to occur by alternatively charging each side of the panel to a critical voltage, which causes repeated gas discharges to occur. In this paper, an efficient sustain driver is proposed to achieve a faster rise-time in order to be suitable to widely used ADS driving method. The proposed circuit increases an operational margin up to 20 % compared with conventional approaches improving the recovery efficiency regardless of the variation of panel capacitance. Thanks to the increased operational margin, the brightness decrease problem can be solved without a limitation to sustain pulse width. The principle of operation, and features are illustrated, and verified on a 7.5 inch diagonal panel at 200 kHz operating frequency - based on experimental prototype.

  • PDF

An Experimental Assessment of Combustion Stability of Coaxial Swirl Injectors and an Impinging Injector through Simulating Combustion Test (상압기상연소시험을 통한 동축형 스월 분사기와 충돌형 분사기의 연소 안정성 평가)

  • Park, Junhyeong;Kim, Hongjip
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2017
  • High-frequency combustion instabilities may occur during the development of feasible engine combustors. These instabilities can result in irreparable damages to the wall of combustors or the degradation of engine performance. So, it is essential to identify injectors that have high stability characteristics during the early stages of development. The objective of present study was to assess the stability of coaxial injectors and an impinging injector with different recess lengths in order to develop stable injectors optimally. Stability margin was evaluated based on the distance from operating condition to the unstable regions. A simulating combustion test method was used to analyze the stability of injectors. A small-scale combustion chamber was designed to simulate the first tangential acoustic mode of the actual combustor. Gaseous oxygen and a mixture of methane and propane were used as simulant propellants to satisfy their flow similarity to the actual propellants of a combustor in a liquid rocket combustor. The results indicated that injectors having small recess lengths showed relatively large combustion stability margins. For the injectors of large recess lengths, instability regions with large and super-large amplitude oscillations were observed. Thus, injector with shorter recess lengths had a higher stability than that of longer one due to the different mixing processes.

Safety margin and fuel cycle period enhancements of VVER-1000 nuclear reactor using water/silver nanofluid

  • Saadati, Hassan;Hadad, Kamal;Rabiee, Ataollah
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.639-647
    • /
    • 2018
  • In this study, the effects of selecting water/silver nanofluid as both a coolant and a reactivity controller during the first operating cycle of a light water nuclear reactor are investigated. To achieve this, coupled neutronic-thermo-hydraulic analysis is employed to simulate the reactor core. A detailed VVER1000/446 reactor core is modeled in monte carlo code (MCNP), and the model is verified using the porous media approach. Results show that the maximum required level of silver nanoparticles is 1.3 Vol.% at the beginning of the cycle; this value drops to zero at the end of cycle. Due to substitution of water/boric acid with water/Ag nanofluid, reactor operation time at maximum power extends to 357.3 days, and the energy generation increases by about 27.3%. The higher negative coolant temperature coefficient of reactivity in the presence of nanofluid in comparison with the water/boric acid indicates that the reactor is inherently safer. Considering the safety margins in the presence of the nanofluid, minimum departure from nucleate boiling ratio is calculated to be 2.16 (recommendation is 1.75).

Use of a helical composite free flap for alar defect reconstruction with a supermicrosurgical technique

  • Jeong, Hyung Hwa;Choi, Dong Hoon;Hong, Joon Pio;Suh, Hyun Suk
    • Archives of Plastic Surgery
    • /
    • v.45 no.5
    • /
    • pp.466-469
    • /
    • 2018
  • The highly contoured nature of the nose and the abundant free margin makes it especially difficult to reconstruct. In this report, we describe the use of a new helical rim free flap technique for the reconstruction of full-thickness nasal alar defects via supermicrosurgery. Briefly, after a wide excision with a margin of 0.7 cm, an alar defect with a size of $1{\times}1{\times}0.5cm$ was obtained, which included the full thickness of the skin, mucosa, and lower lateral cartilage. Vessel dissection was performed in a straightforward manner, starting from the incision margin for flap harvest, without any further dissection for reach the greater trunk of the superficial temporal artery. The flap was inset in order to match the contour of the contralateral ala. We closed the donor site via rotation and advancement. No donor site morbidity was observed, despite the presence of a small scar that could easily be covered with hair. The alar contour was satisfactory, and the patient was satisfied with the results. The supermicrosurgical technique did not require further dissection to identify the vessels for anastomosis, leading to better cosmetic outcomes and a reduced operating time.

Buzz Margin Control for Supersonic Intake Operating over Wide Range of Mach Number (넓은 마하수 영역에서의 초음속 흡입구 버즈마진 제어기법)

  • Park, Iksoo;Park, Jungwoo;Lee, Changhyuck;Hwang, Kiyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.2
    • /
    • pp.27-34
    • /
    • 2014
  • Buzz margin scheduling and control technique which are suitable to regulate stable and high pressure air in wide range of Mach number are suggested for fixed geometry of a supersonic intake. From the analysis of preceding study, most effective control variable is induced and scheduling law is newly suggested in a real application point of view. The appropriateness of the control law in wide range of Mach number is addressed by numerical simulation of controlled propulsion system. Also, the simulation for stabilization and tracking performances of the controller are studied to investigate the phenomena under flight maneuver and disturbances.