• 제목/요약/키워드: operating frequency

검색결과 2,845건 처리시간 0.029초

V/F 일정 운전시의 편측식 선형유도전동기 특성의 실험적 고찰 (An experimental examination of SLIM characteristics under the condition of V/F constant)

  • 조윤현;신판석;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.131-134
    • /
    • 1991
  • In order to determine an operating pattern of SLIM in an experimental MAGLEV vehicle, operating characteristics of SLIM are obtained using a disk type test facility. The test results are compared with the pre-estimated values. It is found that a closed loop control is required for operating at a constant slip-frequency condition which makes the normal force minimum.

  • PDF

X/Ku-대역 광대역 주름형 혼 안테나 설계 (Design of A Broadband Corrugated Horn Operating in X/Ku Band)

  • 곽병석;최종성;방재훈;안병철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(1)
    • /
    • pp.215-218
    • /
    • 2002
  • Design methods are presented for a broadband corrugated horn antenna operating X/Ku band (7.25-14.5 CHz). The corrugated horn consists of a circular waveguide taper, a mode converter, a waveguide-to-horn transition, and a hem section. Methods of design are presented for each section. The designed antenna shows excellent characteristics over the entire operating frequency range.

  • PDF

전력시장에서의 적정 운영예비력 기준에 관한 연구 (A Study on Operation Standards for Optimal Operating Reserve in Electricity Market)

  • 류성호;이강완;김광원;황갑주
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.287-293
    • /
    • 2003
  • The deregulation and structural reform of power markets have started from the early 90s, which has brought about new studies on the new environment. Regardless the market structure, however, power systems need to be operated and planned in a stable and reliable manner. Therefore, decisions on proper amount of operating reserves and their reliable operations are very important. Up to now, the decision processes of operating reserves depend mainly on experiences of operators in Korea. When Korean power market comes under private management, operating reserves would influence power rate as well as power Quality, Therefore, it is time to prepare reasonable operating reserve standards in a systematic way for the new environment. This study suggests the proper operating reserve standards considering rules of the power market in Korea. To verify the adequacy of the proposed standards, stability and frequency characteristics of the Korean power system are analyzed as well.

Electronic Ballast Using a Symmetrical Half-bridge Inverter Operating at Unity-Power-factor and High Efficiency

  • Suryawanshi Hiralal M.;Borghate Vijay B.;Ramteke Manojkumar R.;Thakre Krishna L.
    • Journal of Power Electronics
    • /
    • 제6권4호
    • /
    • pp.330-339
    • /
    • 2006
  • This paper deals with novel electronic ballast based on single-stage power processing topology using a symmetrical half-bridge inverter and current injection circuit. The half-bridge inverter drives the output parallel resonant circuit and injects current through the power factor correction (PFC) circuit. Because of high frequency current injection and high frequency modulated voltage, the proposed circuit maintains the unity power factor (UPF) with low THD even under wide variation in ac input voltage. This circuit needs minimum and lower sized components to achieve the UPF and high efficiency. This leads to an increase in reliability of ballast at low cost. Furthermore, to reduce cost, the electronic ballast is designed for two series-connected fluorescent lamps (FL). The analysis and experimental results are presented for ($2{\times}36$ Watt) fluorescent lamps operating at 50 kHz switching frequency and input line voltage (230 V, 50 Hz).

A Capacitively Coupled Multi-Stage LC Oscillator

  • Park, Cheonwi;Park, Junyoung;Lee, Byung-Geun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권3호
    • /
    • pp.149-151
    • /
    • 2015
  • Coupling with a ring of capacitors introduces in-phase coupling current in multi-stage LC oscillators, increasing coupling strength and phase spacing accuracy. Capacitive coupling is effective at high-frequency applications because it increases coupling strength with the operating frequency. However, capacitive loading from the ring lowers operating frequency and reduces the tuning range. Mathematical expressions of phase noise and phase spacing accuracy with capacitive coupling are examined here, and transistor-level simulations confirm the effectiveness of the capacitive coupling.

A Novel Quasi-Resonant ZCS-PFM DC-DC Switching Regulator with Loosely-Coupled Flyback Inductors

  • Chu E.H.;Chandhaket S.;Moisseev S.;Hiraki E.;Nakaoka M.;Kifune H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.266-270
    • /
    • 2001
  • This paper presents a novel topological prototype of voltage source series quasi-resonant zero current soft-switching pulse frequency modulated dc-dc power converter circuit using IGBTs which incorporates a high-frequency flyback transformer link. Its steady-state operating principle is described on the basis of simulation analysis, along with the open loop controlled power regulation characteristics of the multi-functional coupled inductors linked dc-dc power converter operating under a principle of zero current soft switching commutation.

  • PDF

압전작동기를 이용한 고주파수 젯팅 디스펜서의 성능 특성 (Performance Characteristics of High Frequency Jetting Dispenser Featuring Piezoactuator)

  • 윤보영;구오흥;홍승민;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.595-600
    • /
    • 2007
  • This paper presents a new jetting dispenser driven by a piezoelectric actuator at high operating frequency to provide very small dispensing dot size of adhesive in modern semiconductor packaging processes. After describing the mechanism and operational principle of the dispenser, a mathematical model of the structured system is derived by considering behavior of each component such as piezostack and dispensing needle. In the fluid modeling, a lumped parameter method is applied to model the adhesive whose rheological property is expressed by Bingham model. The governing equations are then derived by integrating the structural model with the fluid model. Based on the proposed model, dispensing performances such as dispensing amount are investigated with respect to various input trajectories.

  • PDF

Design of the High Frequency Resonant Inverter for Corona Surface Processes

  • Choi, Chul-Yong;Lee, Dae-Sik
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.119-122
    • /
    • 2005
  • A algorithm for control and performance of a pulse-density-modulated (PDM) series-resonant voltage source inverter developed for corona-dischange precesses is presented. The PDM inverter produces either a square-wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant dc voltage and operating frequency. Moreover it can achieve zero-current-switching (ZCS) and zero-voltage-switching (ZVS) in all the operating condition for a reduction of switching lost. Even though the corona discharge load with a strong nonlinear characteristics, new high frequency resonant inverter is shown the wide range power control from 5% to 100%.

  • PDF

임펠러 출구에서의 비정상 유동 측정 기법 (Measurement Techniques on Unsteady Flow at Impeller Exit)

  • 신유환;김광호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.123-128
    • /
    • 1998
  • This study presents the measurement techniques on the periodic fluctuating flow such as the discharge flow of a centrifugal impeller in unstable operating region. During rotating stall, the flow at the exit of a centrifugal compressor impeller fluctuates periodically with lower frequency than that of the blade passing. To observe the blade-to-blade flow characteristics during rotating stall, the phases of all the sampled data sets should be adjusted to those of the reference signals with two processes, in these processes, DPLEAT (Double Phase-Locked Ensemble Averaging Technique) can be used. From these measurement and data processing techniques, the characteristics not only on the blade-to-blade flow with high frequency, but also on the periodic rotating stall flow with low frequency at the centrifugal impeller exit can be clearly observed.

  • PDF

1.2 MHz 스파이럴 ECR을 이용한 무선전력전송 기술 (1.2 MHz Wireless Power Transfer Technology using a Spiral-type ECR device)

  • 박재현;양해열;김창선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.54-55
    • /
    • 2011
  • To transfer the power wirelessly, the inverter converted DC power to a high frequency MHz-grade AC power. And the ECR devices for wirelessly transmitting the power are required. In this paper, the spiral-type ECR device and the high frequency inverter were designed. The operating frequency is approximately 1.2MHz. In addition, using a vector network analyzer, the 1.2MHz operating characteristics of the ECR device for wireless power transfer module are analyzed. It is performed and reviewed on validity of wireless power transfer technologies through experiments.

  • PDF