• 제목/요약/키워드: open technique

검색결과 1,384건 처리시간 0.028초

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

에지 컴퓨팅 기반 객체탐지 서비스를 위한 이미지/동영상 데이터 처리 기법에 관한 연구 (A Study on the Image/Video Data Processing Methods for Edge Computing-Based Object Detection Service)

  • 장신원;홍용근
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제12권11호
    • /
    • pp.319-328
    • /
    • 2023
  • 에지 컴퓨팅 기술은 클라우드 컴퓨팅과 달리 기기와 사용자와 가까운 곳에서 데이터를 분석하고 판단하여 실시간 서비스, 민감한 데이터 보호, 네트워크 트래픽 감소와 같은 장점을 제공한다. 에지 컴퓨팅 플랫폼의 대표적인 오픈소스인 EdgeX Foundry는 현실 세계의 다양한 장치와 IT 시스템 사이에서 서비스를 제공하는 오픈소스 기반 엣지 미들웨어 플랫폼이다. EdgeX Foundry는 기존의 센싱된 데이터를 다루기 위한 서비스와 함께 카메라 장치를 다루기 위한 서비스를 제공하는데, 이 서비스는 단순 스트리밍 및 카메라 장치 관리만 지원할 뿐 EdgeX 내부에 장치에서 얻은 이미지 데이터를 저장하거나 처리하지 않는다. 본 논문에서는 EdgeX Foundry에서 제공하는 서비스 일부를 응용하여 EdgeX 내부에 이미지 데이터를 저장하고 처리할 수 있는 기법을 제시한다. 제시한 기법을 기반으로 실험 및 성능 평가를 위해 자율주행 분야에서 핵심적으로 사용되는 객체탐지 서비스를 위한 서비스 파이프라인을 만든 후 기존 방법과 비교 분석하였다. 이 실험을 통해 에지 컴퓨팅 플랫폼에서 이미지/동영상 데이터를 저장하고 처리하는 과정 등이 추가되었음에도 기존 방법에 비해 지연시간이 거의 없는 것을 확인할 수 있었다.

폐구인상채득법을 이용한 임플란트 인상채득 증례 (Implant impression using closed mouth impression technique: a case report)

  • 김소연;김주현;정경화;전혜미;강은숙;윤미정
    • 구강회복응용과학지
    • /
    • 제33권3호
    • /
    • pp.223-229
    • /
    • 2017
  • 단일 치아의 인상채득을 위해서는 바이트 트레이를 이용한 폐구인상법이 선호된다. 그러나 임플란트 인상채득을 위해서는 단일치와 다수치 구분 없이 편악 트레이를 이용한 개구인상법이 주로 사용되고 있다. 바이트 트레이를 이용하는 폐구인상법은 시간이 절약되고 재료가 적게 들며, 모형의 교합기 부착 시 상하악 악간 위치 관계 오차 발생 확률이 적다. 본 증례에서는 2 가지 종류의 폐구인상용 코핑을 이용해 바이트 트레이로 인상채득 후 단일 임플란트 고정성 보철물을 제작함에 있어 만족할 만한 결과를 얻어 보고하고자 한다.

Modified Abbé flap for reconstruction of Cupid's bow and vermilion tubercle in secondary cleft lip deformity

  • Lee, Jun Won;Lee, Seong Joo;Suh, In Suck;Lee, Chong Kun
    • 대한두개안면성형외과학회지
    • /
    • 제19권1호
    • /
    • pp.13-19
    • /
    • 2018
  • Background: $Abb{\acute{e}}$ flap technique is one of the most challenging operations to correct horizontal deficiencies in secondary cleft lip deformity. Since its first introduction, the operative method was dynamically modified from simple variation to complete conceptual change, but conventional $Abb{\acute{e}}$ flap has many drawbacks in esthetic and functional aspect. Our purpose was reconstructing the symmetry of Cupid's bow and central vermilion tubercle with minimal sequalae. Methods: From 2008 to 2016, this technique was applied to 16 secondary cleft lip patients who had total or more than 60% of unilateral deficiency of Cupid's bow and central lip or tubercle pouting deficiency. A quadrangular-shaped flap was transferred from vermilion including skin and white line of central or contralateral lower lip. Pedicle division and insetting were made at 9 (unilateral) or 10 (bilateral) days after transfer. Secondary lip revision was done with open rhinoplasty after wound maturation. Results: Overall satisfaction was high with modified technique. Scar was minimally noticeable on both upper and lower lip especially. Balanced Cupid's bow and symmetric vermilion tubercle were made with relatively small size of flap compared to conventional $Abb{\acute{e}}$ flap. An accompanying benefit was reduced ectropion of lower lip, which made balanced upper and lower lip protrusion with more favorable profile. Conclusion: A new modified $Abb{\acute{e}}$ flap technique showed great satisfaction. It is worth considering in secondary cleft lip patient who has central lip shortage and asymmetry of upper lip vermilion border line. Our technique is one of the substitutes for correction of horizontal and central lip deficiency with asymmetric Cupid's bow.

단일 반송파 변조를 위한 공간 주파수 블록 코드의 난수 부호 반전 기법 (Random Sign Reversal Technique in Space Frequency Block Code for Single Carrier Modulation)

  • 정혁구
    • 한국산업정보학회논문지
    • /
    • 제27권5호
    • /
    • pp.25-36
    • /
    • 2022
  • 본 논문은 단일 반송파 변조를 위한 공간 주파수 블록 코드에서의 랜덤 부호 반전 기술을 제안한다. 종래의 시공간 그리고 공간 주파수 블록 코드는 전파 환경이 공개되어 있으므로 심각한 전파 탈취 문제를 극복해야 한다. 이러한 전파 공개 문제를 피하기 위해, 시공간 블록 코드를 위한 랜덤 코드 데이터 보호 방법이 제안되어 있지만, 이 알고리즘은 직교 주파수 분할 다중화 블록별로 채널 결합을 바꿀 수 있는데, 이와 같은 종류의 느린 스위칭은 근처의 수신기들이 전송된 데이터를 검출할 확률을 증가시킨다. 이 논문은 데이터 심볼 기반의 빠른 스위칭 알고리즘 즉, 단일 반송파 변조를 위한 공간 주파수 블록 코드에서의 랜덤 부호 반전 기술을 제안한다. 모의실험 결과는 제안하는 알고리즘이 랜덤 부호 반전 타이밍 시퀀스를 모르는 수신기의 성능과 비교하여 우수한 성능을 보유하고 있다는 것을 나타내었다.

회전개근 순수 관절경적 봉합술과 국소절개 구제봉합술 비교분석 : 2~6년 추시결과 분석 (Arthroscopic Versus Mini-Open Salvage Repair of the Rotator Cuff Tear : Outcome Analysis at Two to Six Years Follow-up)

  • 김승호;하권익;박종혁;강진석;오성균;오일빈;유재철
    • Clinics in Shoulder and Elbow
    • /
    • 제5권2호
    • /
    • pp.88-97
    • /
    • 2002
  • The purpose of this study was to compare the outcomes between arthroscopir repair and mini-open repair of medium and large rotator cuff tears in which arthroscopic repair was technically unsuccessful. We evaluated 76 patients of full-thickness rotator cuff tears, among them 42 patients had all-arthroscopic and 34 patients had mini-open salvage repairs. Patients who had acromioclavicular arthritis, subscapularis tear, or instability were excluded. There were 39 males and 37 females with mean age of 56 years (range,42 to 75 years). At a mean follow-up of 39 months (range, 24 to 64 months), the results of both groups were compared with regard to the UCLA and ASES shoulder rating scale s. Shoulder scores improved in all ratings in both groups (p > 0.05). Overall, sixty-six patients showed excellent or gr)of and ten patients showed fair or poor scores by the UCLA scale. Seventy-two patients satisfactorily returned to prior activity. Four showed unsatisfactory return. The range of motion, strength, and patient's satisfaction were improved postoperatively. There were no difference in shoulder scores, pain, and activity return between the arthroscopic and mini-open salvage groups (p > 0.05). However, Patients with larger size tear showed lower shoulder scores and less predictive recovery of the strength and function (p < 0.05). Postoperative pain was not different with respect to the size of the tear (p : 0.251). Arthroscopic repair of medium and large full-thickness rotator cuff tears had iln equal outcome to technically unsuccessful arthroscopic repairs, which were salvaged by conversion to a mini- open repair technique. Surgical outcome depended on the size of the tear, rather than the method of repair.

주관절 구축의 관혈적 치료 (The Open Surgical Treatment for Stiff Elbow)

  • 이지호;라인후;전인호
    • Clinics in Shoulder and Elbow
    • /
    • 제13권2호
    • /
    • pp.293-298
    • /
    • 2010
  • 목적: 주관절은 굴곡 구축 40도 이상 굴곡 제한 105도 이하일 경우 일상 생활에 상당한 장애를 일으킬 수 있는 관절로 그 치료의 정도 및 시기를 결정하기가 상당히 어려운 것으로 알려져 있다. 이에 이 종설에서는 현재까지 인정된 주관절 구축의 수술적 접근법에 대하여 고찰하여 보도록 하겠다. 대상 및 방법: 환자의 병력을 포함하여 충분한 임상적 조사를 하는 것이 중요하다. 그리고 방사선학적 방법을 이용하여 환자의 주관절 구축에 대한 원인 및 상태를 정확히 파악하고 그에 적합한 수술법을 선택한다. 수술법으로는 관절경적 유리술 (arthroscopic release) 및 관혈적 유리술 (Open release), 견인 관절 성형술 (Distraction Arthroplasty), 인공관절 치환술 (Total elbow replacement)이 있으며 관혈적 유리술은 4가지 기본 도달법 -전방 도달법 (anterior approach), 내측 도달법 (medial "over the top" approach), 제한된 외측 도달법 (limited lateral approach: column procedure) 광범위 후방 도달법 (posterior extensile approach)-으로 분류될 수 있다. 결과 및 결론: 현재 주관절 구축의 수술은 관절경의 발달로 인한 최소 침습적인 방법이 대두되고 있으나 그 경과의 판정은 아직 미미하며 그에 대한 문헌 보고가 많지 않은 상태로 고식적인 개방성 접근법을 이용하는 것을 원칙으로 하고 있으며 접근법에 따른 분류를 사용하고 있다.

열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가 (Evaluation of the Breast plan using the TLD and Mosfet for the skin dose)

  • 김선명;김영범;이상록;백상윤;정세영
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.107-113
    • /
    • 2015
  • 목 적 : 유방암 치료에 있어 피부선량의 측정은 매우 중요하다. 치료계획시에는 처방선량에 비해 초과선량이나 부족선량이 생길 수 있으므로 이에 대한 유방암의 여러 가지 치료계획간 피부선량 평가가 필요하다. 이에 대해 본원에서는 다양한 선량계를 이용하여 선량을 분석하여 유방암치료에 적용하고자 한다. 대상 및 방법 : 유방암은 기본적으로 접선방향 치료계획 시 일어나는 skin dose(Drain site, Scar)의 선량차이를 알아보기 위하여 인체모형팬텀을 이용하였다. 인체모형팬텀을 전산화단층촬영하고 전산화치료계획에서 open과 쐐기필터(Wedge filter)를 이용한 치료계획, Field-in-Field를 이용한 치료계획, 그리고 Dose fluence를 이용한 Irregular compensation 치료계획을 세우고 컴퓨터치료계획 프로그램(Eclipse)으로 선량관심점과 측정점의 선량을 비교하였다. 치료실에서 인체모형팬텀을 위치시키고 선량비교를 위하여 각 치료계획 측정점에 열형광선량계(themoluminesence dosimeter, TLD)와 MOSFET(Metal oxide-silicon field effect transistor)을 이용하여 선량을 측정하여 비교평가 하였다. 결 과 : 피부선량은 치료계획 중심점을 기준으로 위와 아래는 Dose fluence를 이용한 Irregular compensation 치료계획 사용 시 MOSFET을 이용한 선량측정에서 가장 많은 선량이 들어가는 것으로 나타났다. 내측과 외측의 측정선량은 open과 쐐기필터 치료계획에서 TLD와 MOSFET을 이용하여 측정시 5.7%에서 10.3%까지 낮게 나타났다. 반대쪽 유방의 선량은 open 치료계획이 가장 적었고, Dose fluence를 이용한 Irregular compensation 치료계획을 사용 시 가장 많은 선량이 측정되었다. 치료종별 치료계획상에서는 내측과 외측의 선량편차가 가장 컸으며, TLD와 MOSFET 측정시에도 같은 경향을 보였다. 외측은 TLD, 내측은 MOSFET이 가장 편차가 컸다. 결 론 : 치료계획에 따른 피부선량은 전반적으로 Dose fluence를 이용한 Irregular compensation의 치료계획을 사용 시 가장 많이 들어가는 것으로 나타났으며, 이는 많은 MLC의 움직임에 의한 산란선 영향으로 생각된다. 모든 치료계획에서 피부의 위치에 따라 약간의 차이는 있으나 부족선량이 생기는 부분에서는 내측의 내유임파절(Intramammary lymph nodes)선량이나 Scar, Drain site등에서 세심한 주의가 필요하다. 부족선량을 높이기위해서는 Dose fluence를 이용한 Irregular compensation의 치료계획을 사용하는 것이 좋겠으나, 전체적인 선량을 높이기보다는 선택적인 범위내에서 선량을 높이게 되므로 환자의 연령이나 움짐임 등을 고려하여 치료기술을 선택하는 것이 바람직할 것으로 사료된다.

  • PDF

선박설계용 VR의 3차원 입체 형상 구현 (Stereoscopic)의 적용성에 대한 연구 (A Study on the stereoscopic method for 3 dimensional expression in VR application for ship design)

  • 이재환;박병재
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.101-105
    • /
    • 2004
  • In this paper, theoretical basis of stereoscopic display is investigated and programmed to shaw the application which could be used in the Virtual Reality (VR), especially for ship design. Stereoscopic is based on the seperated view point of left and right eyes on the screen and making 3 dimensional image. There different stereoscopic methods such are red-blue, interlacing, side-by-side and above-below are imvestigated and implemente to shaw the simple ship model and inside of ship. To shaw the 3 dimensional view, OpenGL is used to make program by implementing the logic of stereoscopic. Simple models and ship design are implemented to survey the applicability of stereoscopic for ship design. The best way is to use two projectors to emit interlaced shape. It is expected to imply this technique in the VR application for ship design.

  • PDF

Open and Short Circuit Switches Fault Detection of Voltage Source Inverter Using Spectrogram

  • Ahmad, N.S.;Abdullah, A.R.;Bahari, N.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.190-199
    • /
    • 2014
  • In the last years, fault problem in power electronics has been more and more investigated both from theoretical and practical point of view. The fault problem can cause equipment failure, data and economical losses. And the analyze system require to ensure fault problem and also rectify failures. The current errors on these faults are applied for identified type of faults. This paper presents technique to detection and identification faults in three-phase voltage source inverter (VSI) by using time-frequency distribution (TFD). TFD capable represent time frequency representation (TFR) in temporal and spectral information. Based on TFR, signal parameters are calculated such as instantaneous average current, instantaneous root mean square current, instantaneous fundamental root mean square current and, instantaneous total current waveform distortion. From on results, the detection of VSI faults could be determined based on characteristic of parameter estimation. And also concluded that the fault detection is capable of identifying the type of inverter fault and can reduce cost maintenance.